Manuscript Offprint

arXiv:2610.17576

Dissociating Answerability from Extraction in LLM Question Answering over Radiology Reports

Priyanshu Sinha, Kelsey McDonald

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Answering questions from radiology reports involves two decisions: whether the report contains an answer and which span gives it. A false answer presents an unsupported claim as fact; an over-abstention hides what the report says. Yet RadQA results are reported as a single F1 that merges both. We propose an evaluation method that separates them, reporting false-answer and over-abstention rates beside F1 and splitting F1 changes into extraction and answerability terms. We apply it to 13 LLMs on the RadQA test set, zero-shot and with three cumulative demonstration sets, the last adding an unanswerable example. Models with similar F1 differed more than twofold in false-answer rate. The unanswerable example changed when models answered, not how well they extracted: 12 of 13 models abstained more often, and three-quarters of the answers they withdrew had F1 ≥\geq 0.5. Within models, false answers showed no clear association with extraction quality, but acting on the decision itself helped: keeping an answer only when enough other models also answered lowered the zero-shot false-answer rate by 4 points without a detectable F1 change. Because the two decisions can change independently, we suggest radiology QA evaluations report them separately, not through F1 alone.

1 Introduction

Large language models (LLMs) perform strongly on medical licensing-exam questions (Singhal et al., 2023; Nori et al., 2023) and medical evidence summarization (Tang et al., 2023), and are increasingly applied to patient records, from answering clinicians' questions about them (Fleming et al., 2024) to extracting information from radiology reports (Le Guellec et al., 2024). Radiology reports are a natural target for LLM question answering: they are produced in large volumes, use dense domain terminology, and are read by ordering physicians who need accurate answers from them. Exam benchmarks test medical knowledge, not the reading of a specific report, where the answer must be found in a section such as Findings or Impression and is sometimes not there at all.

Extractive question answering (QA) over reports is a controlled version of this setting: the answer is a verbatim span of the report, or the model declines because it decides the question is unanswerable. In RadQA (Soni et al., 2022), physicians wrote questions from the clinical referral of MIMIC-III radiology reports (Johnson et al., 2016a,b) without seeing the report text, so a quarter of its test questions have no answer in the report. Such a system makes two decisions per question: whether the report answers it, and if so, which span does. The two fail in clinically distinct ways. A false answer to an unanswerable question puts a statement the report does not support in front of a clinician; an over-abstention withholds information the report contains and sends the clinician back to the full text.

The standard metric, SQuAD 2.0 F1 (Rajpurkar et al., 2018), folds both decisions into one number: a correct abstention scores 1, a wrong answer/abstain decision scores 0, and otherwise the score is token overlap between words in a predicted answer and the ground-truth answer. Models with the same F1 can therefore give very different numbers of false answers, and a change in F1 between prompts can come from better spans or from a moved abstention boundary. SQuAD 2.0's evaluation does also report F1 separately on answerable and unanswerable questions (HasAns/NoAns), and NoAns F1 is exactly one minus the false-answer rate. But RadQA results are reported only as overall F1 and EM (Soni et al., 2022; Al Nahian and Kavuluru, 2025). Even HasAns F1 mixes the two decisions: it equals the share of answerable questions answered times the mean F1 of those answers, so it changes when either one does.

The distinction matters most for in-context demonstrations, the obvious intervention that needs no training. On RadQA, LLMs still trail task-specific fine-tuning: RadQA-DPO (Al Nahian and Kavuluru, 2025) reaches 77.48 test F1 and 55.15 exact match (EM), and the two annotators reach 78.72 and 90.31 F1 (Soni et al., 2022). In-context demonstrations (Brown et al., 2020) could narrow this gap if they improve extraction, but not if they mainly move the answer/abstain boundary. Studies of demonstration choice, order and format report effects on aggregate accuracy (Zhao et al., 2021; Lu et al., 2022; Min et al., 2022), which cannot tell which decision moved.

We propose an evaluation method that separates the two decisions, reporting the false-answer rate (FAR) and over-abstention rate (OAR) beside span F1, and apply it to 13 LLMs from six families on the RadQA test set, zero-shot and with three cumulative demonstration sets (an answerable Findings question, an answerable Impression question, and an unanswerable question). Our contributions:

  1. A decomposition of ΔF1\Delta F1 that isolates extraction, with a selectivity test ( §3.4\S3.4). Any change in F1 splits into an extraction term, computed on answerable questions answered in both conditions, and an answerability shift. A companion test asks whether new abstentions remove weak answers or good ones. Unlike a change in HasAns F1, the extraction term contains no abstentions, and both tools work with any span metric. FAR and OAR follow from the standard HasAns/NoAns breakdown, so we offer them as a reporting recommendation rather than as new metrics.

  2. The tested unanswerable demonstration moves the answer decision, not extraction ( §4.2§4.2). It raises OAR in 12 of 13 models. Of the resulting -0.0126 change in F1, -0.0127 is answerability shift, and extraction is flat under both token and RadGraph F1 (Jain et al., 2021). For answerable demonstrations, the split depends on the span metric.

  3. The added abstentions are not detectably selective ( §4.3§4.3). Three-quarters of the 272 withdrawn answers had F1≥0.5F1 \geq 0.5. In exchange, models gave a net 55 fewer false answers, most of them from one model.

  4. Similar F1, different false-answer rates ( §4.1§4.1, §4.4§4.4; Figure 1). Eleven of 13 models lie within 0.669–0.738 zero-shot F1, while FAR ranges

Figure

Figure 1: Zero-shot span F1 against false-answer rate (FAR) for the 13 LLMs, with report-clustered 95% CIs. The shaded band holds 11 models within 0.07 F1 that differ more than twofold in FAR. Squares mark the example pair discussed in §4.1: Claude Sonnet 4.5, the lowest-FAR model, and LLaMA 4 Maverick, the highest-F1 model whose FAR is significantly higher than Sonnet 4.5's. They differ by 0.007 in F1 but 0.110 in FAR. Values for unlabelled models are in Table 1.

from 0.117 to 0.260. The cross-model F1–FAR correlation is largely built into the metric, and within a model we find no association between extraction quality and false answers.

  1. Evaluating a mitigation that targets the answer decision ( §4.5§4.5). A consensus gate, cross-fitted over reports, lowers zero-shot FAR by 4 points with no detectable F1 change.

We also find that no model matches the exact match of the fine-tuned RadQA-DPO, and none reaches inter-annotator agreement ( §4.1§4.1). Our code is available at https://github.com/pri2si17-1997/rad-qa-llm-eval.

References (22)