Manuscript Offprint

arXiv:2610.18105

Chain of Thought Monitoring Can Fail Even When CoT Is Necessary

Lennart Bürger, Piotr Komorowski, Moritz Weckbecker, Evgenii Kortukov, Aakriti Jain, Sebastian Lapuschkin, Wojciech Samek

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

ABSTRACT

Chain of Thought (CoT) monitoring is used by frontier labs to detect misbehaviour of AI systems. Yet, its reliability remains poorly understood. We attribute this to the lack of a successful organizing principle that leads to generalizable conclusions about monitoring reliability in different regimes. Recent work attributes monitoring failures to the CoT not being necessary for the answer, and argues that CoT becomes monitorable when it is necessary. We show that this binary necessary/not-necessary organizing principle is too coarse by demonstrating that monitoring failures persist even if the CoT is necessary for the answer. In response, we introduce a more fine-grained organizing principle based on a hierarchy of four CoT necessity levels. Building on this hierarchy, we develop a framework for measuring CoT monitorability at the three lowest levels via intervention experiments. We demonstrate monitoring failures at all three of these levels on realistic, hard prediction tasks. On a difficult medical-diagnosis task, patient sex and a clinical attribute influence the answer in at least 19% and 24% of correct responses with a necessary CoT, respectively, yet their influence is almost never articulated. These results show that even when CoT is necessary, it is not guaranteed to be monitorable.

1 INTRODUCTION

Modern Large Language Models (LLMs) generate a long Chain of Thought (CoT) (Nye et al., 2021; Wei et al., 2022) before producing their final answer, which improves performance on a wide range of challenging tasks (Singh et al., 2025; Comanici et al., 2025). Because LLMs express their CoT reasoning in natural language, analyzing the CoT holds promise for understanding how a model arrives at its answer, with potential applications in both AI Safety (Amodei et al., 2016; Baker et al., 2025) and Explainability (Samek et al., 2017; Barez et al., 2025). Frontier labs already use CoT monitoring to detect misbehaviour of AI systems (Baker et al., 2025).

However, despite this reliance on CoT monitoring, its reliability is still poorly understood (Korbak et al., 2025; Barez et al., 2025), and prior work studying its reliability has found mixed results. A prominent line of work has demonstrated monitoring failures in which a model's answer was strongly influenced by a bias or hint, yet this influence was rarely articulated in the CoT (e.g. Turpin et al., 2023; Karvonen & Marks, 2025). In contrast, Baker et al. (2025) demonstrated that CoT monitors catch reward hacks of frontier models on coding tasks with high reliability, while Li & Siegel (2025) found mixed results when applying CoT monitors to sandbagging detection. Overall, we cannot yet reliably predict, for a given (mis)behavior, whether CoT monitors will catch it.

We attribute this gap to the lack of a successful organizing principle that allows testing CoT monitorability in different regimes and drawing some generalizable conclusions within each regime. Emmons et al. (2025) made a first attempt at such an organizing principle by distinguishing between CoTs that are necessary for a task and those that are not, an intuitive distinction also made by Korbak et al. (2025). As argued by Emmons et al. (2025), prior demonstrations of monitorability failures occurred in a regime where the CoT was not necessary to arrive at the final answer. According to Emmons et al. (2025), these monitorability failures can be explained by "the CoT acting as a post-hoc rationalization for an answer the model has already computed internally". In contrast, if the CoT is necessary, they argue, the CoT becomes monitorable.

In this paper, we show monitorability failures that demonstrably cannot be explained by rationalization because the CoT was necessary for the answer. The binary organizing principle by Emmons et al. (2025) is therefore too coarse,

*Correspondence to: Lennart.Buerger@hhi.fraunhofer.de

Code available at https://github.com/LennartBuerger/Monitoring_Necessary_CoT

Chain-of-Thought monitoring failures persist even when CoT is necessary for the answer

Figure

Example of a Monitorability Failure

The patient's sex affects the answer, but its influence is almost never articulated.

Figure

Figure 1: Left: The average monitorability scores on our three challenging datasets for Qwen3-8B. Monitoring failures persist even on the subset of CoTs that were necessary to arrive at the answer. Right: Example of a monitorability failure. On a difficult medical diagnosis task where CoT is necessary, the patient’s sex strongly influences the model’s answer distribution but its influence is almost never articulated in the CoT.

since monitoring failures can appear in both categories. We propose a more fine-grained alternative and introduce a hierarchy of levels of CoT necessity. In summary, our contributions are as follows:

• We propose an organizing principle for testing CoT monitoring in different regimes. We introduce a hierarchy of CoT necessity levels ( §2.2\S2.2) and propose to study different monitorability types ( §2.1\S2.1) across these levels.

• We define a novel CoT monitorability measure to test whether the CoT is monitorable when it is necessary to arrive at the answer ( §3\S3). We later extend it to test whether the CoT is monitorable when it is necessary to process the monitored property ( §6\S6).

• We demonstrate CoT monitorability failures at three levels of CoT necessity via intervention experiments ( §5§5, §6§6) for four different LLMs from the Qwen-3 and Gemma-4 model families. Our experiments are the first to show monitorability failures on CoTs that were demonstrably necessary to arrive at the answer ( §5.2§5.2) and which cannot be explained by rationalization.

Our research is a first step towards a more rigorous understanding of the reliability of CoT monitoring at different levels of CoT necessity and across types of monitorability.

References (46)