arXiv:2610.18556cs.CVOct 2026

Manuscript Offprint

arXiv:2610.18556

Denoise X: Self-Supervised U-Net for Quantum Mottle Suppression in Chest Radiography

Parth Giramkar, Aryan Patle, Vanita Kshirsagar

Parth Giramkar

Department of Artificial Intelligence and Data Science

Dr. D. Y. Patil Institute of Technology

Pune, Maharashtra 411018, India

imparthgiramkar@gmail.com

Aryan Patle

Department of Artificial Intelligence and Data Science

Dr. D. Y. Patil Institute of Technology

Pune, Maharashtra 411018, India

aryanpatle031@gmail.com

Vanita Kshirsagar

Department of Artificial Intelligence and Data Science

Dr. D. Y. Patil Institute of Technology

Pune, Maharashtra 411018, India

vanita.kshirsagar@gmail.com

Abstract—Deep learning approaches have demonstrated significant potential for medical image restoration; however, their clinical application is often constrained by the requirement for large-scale paired training data under supervised learning. In particular, acquiring perfectly registered clean-noisy radiograph pairs in vivo is impractical due to patient motion, physiological variations, and radiation-dose constraints governed by the ALARA (As Low As Reasonably Achievable) principle. To address this limitation, a self-supervised Noise2Noise learning paradigm is employed, enabling training using independently corrupted observations without requiring paired clean images while preserving clinically important anatomical structures. Based on this approach, Denoise X is proposed as a lightweight self-supervised U-Net-based model with 7.79 million parameters for suppressing quantum mottle and electronic readout noise in low-dose chest radiographs. The model is trained entirely on the NIH ChestX-ray14 dataset containing 112,120 images using a stochastic Poisson–Gaussian noise simulator to generate realistic radiographic degradations. Zero-shot evaluation on the unseen Montgomery County dataset achieved a PSNR of 36.09 dB and an SSIM of 0.8806, substantially outperforming the Bilateral filter in structural similarity while preserving high-frequency anatomical details. Using patch-wise inference, the proposed model processes native-resolution multi-megapixel chest radiographs in approximately 2.2 s per image on a Tesla P100 GPU. Cross-domain evaluation on an unseen Shenzhen dataset image further achieved a PSNR of 36.44 dB and an SSIM of 0.9099, demonstrating promising generalization across imaging distributions. For resource-constrained deployment, the trained model was converted into a lightweight 31.16 MB ONNX model for CPU inference, with adaptive preprocessing enabling efficient processing of high-resolution non-DICOM images.

Index Terms—Chest Radiography, Quantum Mottle, Noise2Noise, Self-Supervised Learning, U-Net, Poisson–Gaussian Noise, ONNX Edge Deployment

I. INTRODUCTION

The use of chest X-rays is one of the most common forms of medical imaging worldwide and serves as a first-line diagnostic tool for numerous cardiopulmonary disorders [8]. To ensure patient safety during examinations, radiation exposure should be minimized according to the As Low As Reasonably Achievable (ALARA) principle, which implies minimal exposure of patients to ionizing radiation [9]. However, any decrease in photon flux necessarily reduces the signal-to-noise ratio of the detector, leading to increased quantum mottle (photon shot noise) and electronic noise that can mask high-frequency anatomical structures [9]. Therefore, the development of advanced deep learning-based denoising techniques is crucial.

Traditional spatial filters such as Bilateral [1] and Median filters are commonly used to address this problem. Despite being computationally inexpensive, these methods rely on local neighborhood statistics and may suppress image noise together with diagnostically important structural edges. In contrast, supervised deep learning frameworks [2], [3] have demonstrated promising results in medical image restoration. However, these frameworks face a significant data bottleneck, as obtaining precisely aligned pairs of noisy and clean radiographs is difficult in in-vivo environments due to patient motion and radiation exposure constraints.

Recent developments in deep learning have led to highly effective frameworks such as vision transformers [6] and advanced convolutional networks [7], which demonstrate excellent performance in image restoration. However, their increased computational complexity may limit their use in resource-constrained healthcare environments. Processing native-resolution, multi-megapixel clinical chest X-rays through such architectures can require substantial computational resources and hardware acceleration.

The paired-data limitation can be addressed using the Noise2Noise technique [4]. Given the independence and zero-mean assumption of the radiographic noise, minimizing the Noise2Noise loss can recover the underlying clean signal without requiring clean ground-truth images. Building upon this principle, Denoise Xis proposed as a lightweight U-Net architecture trained on the NIH ChestX-ray14 dataset [8] using a stochastic Poisson–Gaussian noise model [10]. Additionally, patch-wise inference is employed for native-resolution chest radiography while maintaining compatibility with standard CPU-based deployment.

The main contributions of this work are as follows:

• Self-Supervised Architecture: A lightweight, self-supervised Noise2Noise U-Net architecture with 7.79 million parameters is introduced, trained using a stochastic Poisson–Gaussian simulator without requiring paired clean ground-truth data.

• Edge-Optimized Inference Framework: A patch-wise inference framework optimized for ONNX CPU run-times is presented, enabling native-resolution inference of multi-megapixel chest X-rays in resource-constrained environments.

• Zero-Shot Evaluation: Zero-shot evaluation on the unseen Montgomery County dataset demonstrates that the proposed method achieves 36.09 dB PSNR and 0.8806 SSIM, where the proposed method achieves 36.09 dB PSNR and 0.8806 SSIM, substantially outperforming conventional spatial filtering techniques.

• Cross-Domain Generalization: Generalization to a different imaging domain is demonstrated through quantitative and qualitative evaluation on an unseen chest X-ray from the Shenzhen dataset.