Manuscript Offprint
arXiv:2610.18682Physics-Informed Deep Learning in Oncology
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
ARTICLE INFO
Keywords:
Physics-informed deep learning
Oncologic imaging
Computational oncology
Biomedical imaging
Scientific deep learning
ABSTRACT
Deep learning has enabled substantial advances in oncology, including cancer detection and diagnosis, medical image analysis, tumor characterization, treatment planning, response assessment, and outcome prediction. However, conventional data-driven models often require large annotated datasets, exhibit limited generalization across heterogeneous clinical settings, and lack explicit mechanisms for incorporating the physical, physiological, and biological principles underlying cancer development and treatment. Physics-informed deep learning (PIDL) integrates governing physical laws, mechanistic models, physiological constraints, and domain knowledge into deep learning frameworks, providing a principled approach for learning from sparse, noisy, and heterogeneous oncological data. This review presents a task-oriented synthesis of PIDL methods across oncology, encompassing neural networks, Kolmogorov–Arnold networks, convolutional and vision architectures, neural operators, generative models, and hybrid physics–data-driven frameworks. Their applications are examined across cancer detection and diagnosis, image reconstruction and analysis, tumor characterization, quantitative imaging, tumor progression, treatment response, radiation therapy, treatment planning, and multimodal clinical modeling. Based on the synthesized methodological and application-level evidence, we develop task-optimized PIDL workflows that align the clinical task with appropriate data representations, physical constraints, model architectures, and validation strategies. We further analyze key challenges, including physical-model fidelity, computational scalability, uncertainty quantification, domain generalization, standardized benchmarking, and clinical validation. Emerging directions involving multimodal foundation models, patient-specific digital twins, uncertainty-aware learning, and agentic PIDL are also discussed. This review provides a unified framework for understanding and designing task-specific PIDL approaches for oncology and identifies methodological requirements for their reliable clinical translation.
Corresponding author
scindhiya@iitism.ac.in (S. Laxmi); vyadav06@mail.ubc.ca (V.S. Yadav); ajagtap@wpi.edu (A.D. Jagtap)
Page 1 of 51
Oncology Inputs

Figure 1: PIDL pipeline for oncology: multimodal inputs and tumour growth models are processed by PIDL-family frameworks under shared physics priors to enable parameter fitting, growth-law discovery, imaging harmonization, patient-specific forecasting, and uncertainty quantification, supporting response forecasting, radiotherapy planning, and digital twins.
Despite these advances, purely data-driven deep learning models face fundamental limitations that restrict reliable clinical deployment. Their performance is heavily dependent on large and high-quality annotated datasets, which are scarce in oncology due to annotation costs, privacy constraints, institutional fragmentation, and disease heterogeneity [11]. Models trained on limited or institution-specific datasets often exhibit poor generalisation across scanners, protocols, and patient populations. Moreover, most deep learning models operate as black-box function approximators, offering limited interpretability and weak uncertainty quantification [12]. At the fundamental level, deep learning lacks explicit mechanisms to enforce the physical principles that govern image formation, signal generation, and tissue dynamics. Consequently, visually convincing predictions frequently violate established physical and physiological constraints, resulting in hallucinated anatomical structures, unstable image reconstructions, and unreliable quantitative biomarkers [13]. These limitations have motivated the emergence of physics-informed deep learning (PIDL) [14], a paradigm that integrates governing physical knowledge directly into the learning process; see Figure 1. Rather than relying solely on empirical data, PIDL embeds scientific priors, including governing partial differential equations (PDEs), imaging forward operators, conservation laws, constitutive relationships, biomechanical models, pharmacokinetic constraints, and acquisition physics, within neural network architectures or optimisation objectives [15]. By constraining the solution space with established physical principles, PIDL leads to predictions that are both data-driven and physically consistent, thus improving generalisation under limited supervision, improving interpretability, and reducing dependence on large datasets [16].
Page 2 of 51
Oncological modeling and data analysis are especially well suited to PIDL, as tumor initiation, progression, and therapeutic response are governed by well-established biological, physiological, and physical mechanisms [17]. Many computational oncology problems, including image reconstruction, quantitative parameter estimation, kinetic modeling, radiation dosimetry, and tumor progression analysis, are formulated as forward or inverse problems constrained by known physical laws but are often challenged by sparse, noisy, or indirect measurements [18]. Incorporating these mechanistic models into deep learning enables physically admissible inference while preserving the expressive power of neural networks. Building on the foundational concept of physics-informed neural networks (PINNs) [14, 19–27], the field has rapidly evolved to include eXtended PINNs (XPINNs) [28], conservative PINNs (cPINNs) [29], scientific foundational models [30], neural operators [31–33], physics-informed convolutional neural networks (PICNNs) [34], physics-informed Kolmogorov-Arnold Networks [35], hybrid mechanistic learning frameworks [36], transformer-based physics-guided architectures [37] and Bayesian formulations for uncertainty quantification [38]. Collectively, these developments have substantially expanded the applicability of PIDL across diverse oncologic imaging tasks [15, 18].
Despite the growing body of review literature on PIDL and its applications in biomedical research [15, 18, 39–42], a dedicated synthesis of PIDL for computational oncology remains lacking. Existing reviews lack a unified perspective on the end-to-end computational cancer research workflow and do not systematically examine how imaging physics and modality-specific acquisition mechanisms shape the design and application of PIDL across different modalities. Furthermore, the methodological foundations, complementary capabilities, and limitations of PINNs, PICNNs, PIKANs, neural operator-based methods, and uncertainty-aware mechanistic models have not been systematically compared within the context of oncologic data analysis. Current review literature also provides limited discussion of the challenges associated with clinical translation, including uncertainty quantification, domain generalisation, standardised benchmarking, and prospective clinical validation. To address these gaps, this review presents a comprehensive and unified perspective on PIDL in oncology. It systematically synthesizes methodological advances, task-oriented and modality-specific applications, benchmark datasets, evaluation protocols, translational challenges and future research opportunities. The principal contributions are as follows:
-
Systematic evolution of PIDL: We trace the methodological progression from conventional PINNs to contemporary architectures, including PICNNs, PIKANs, physics-informed neural operators (PINO), physics-informed generative models, transformer-based PIDL, Bayesian multi-fidelity frameworks and hybrid mechanistic-deep learning approaches.
-
Task-oriented taxonomy of physics-informed learning in oncology: We organize PIDL applications according to clinically relevant oncology tasks, namely reconstruction, denoising, registration, biomechanical motion correction, super-resolution, tumor segmentation, detection, metabolic quantification, treatment planning and therapy monitoring.
-
Modality-oriented taxonomy of physics-informed learning in oncology: We systematically examine PIDL across CT, MRI, PET, ultrasound, and thermal imaging, extending the analysis to hybrid imaging and multi-physics models. We highlight how modality-specific acquisition mechanisms, and coupled physical processes influence model design, computational challenges, and reliability in oncological applications.
-
Comparison with purely data-driven deep learning: We contrast conventional CNN- and transformer-based oncological task pipelines with physics-informed paradigms, highlighting their respective limitations in data dependence, interpretability, robustness and physical consistency.
-
Translational challenges: We critically examine the key methodological, computational, and clinical barriers to translating PIDL into cancer research and clinical practice.
-
Design principles and future research directions: We identify suitable PIDL strategies for diverse oncological tasks and discuss emerging research directions, including multimodal foundation models, digital twins, Bayesian multi-fidelity learning, and agentic and trustworthy PIDL, to advance precision oncology.
Together, these contributions establish a unified framework that connects methodological advances with clinical translation, providing a foundation for the next generation of reliable, interpretable and clinically deployable physics-informed AI in oncologic imaging.
Page 3 of 51
2. How to make neural network models physics-informed
Conventional deep-learning models learn a mapping from inputs to outputs by minimizing a data-driven loss. PINNs instead embed governing laws directly into the learning problem, so that the network is trained to satisfy the governing equations, initial conditions and boundary conditions as well as the observations .
Consider a physical system governed by a time-dependent differential equation on a spatial domain over a time interval ,
where is the unknown field and is the governing differential operator. The problem is closed by an initial condition, , and a boundary condition, on . A neural network with trainable parameters approximates the solution. Substituting this approximation into equation (1) defines the physics residual
whose derivatives are evaluated exactly by automatic differentiation [45]. Enforcing the residual at collocation points, the initial condition at points and the boundary condition at points gives
When measurements or high-fidelity simulations are available at points, a data-consistency term is added. The physics-informed objective is the weighted sum
in which the coefficients set the relative influence of each constraint (Fig. 2). The balance is not trivial. Competing loss terms can produce imbalanced gradients and stiff optimization, and the choice of weights, sampling and architecture strongly affects whether training converges [46, 47].
The central distinction from conventional deep learning is that a physics-informed model does not rely on observational examples alone. Known physical laws regularize the learning problem, so that limited, noisy or expensive data can be complemented by prior knowledge and the network is steered towards physically consistent solutions. The same principle has since been realized in several architectural families, each of which replaces or augments the multilayer perceptron (MLP) ansatz in a different way: Kolmogorov-Arnold networks, CNNs, neural operators and generative models; see Fig. 2.
2.1. Physics-informed Kolmogorov-Arnold networks
Kolmogorov-Arnold networks (KANs) [35, 48] offer an alternative to the MLP for representing nonlinear functions. Motivated by the Kolmogorov-Arnold representation theorem, a KAN decomposes a multivariate function into compositions of learnable univariate functions. Whereas an MLP places fixed activation functions on nodes, a KAN places trainable univariate functions on edges, commonly parameterized with B-spline bases so that the nonlinearity is learned directly from data [49, 50]. The l-th layer maps inputs to outputs as
Page 4 of 51
PIDL Architectures
a PINN Feed-Forward Neural Network (FFNN)

Dense layers with fixed nonlinear activation on every node
b PIKAN Kolmogorov–Arnold network (KAN)

Learnable univariate splines on every edge; nodes only sum

c PICV Convolutional Network (computer vision)

Encoder-decoder CNN with skip connections on an (x, t) grid; derivatives by finite differences
d PINO e.g., Fourier neural operator (FNO)

Maps an input function a to the solution field ; resolution-independent; spectral derivatives
No: Update
?
Backpropagation · Optimizer step
Yes
Converged
Figure 2: The PIDL family: Four architectures share one training loop. a, Physics-informed neural network (PINN): a feed-forward network maps to . b, Physics-informed Kolmogorov-Arnold network (PIKAN): learnable splines on edges. c, Physics-informed computer-vision network (PICV): a convolutional encoder-decoder with skip connections. d, Physics-informed neural operator (PINO): Fourier layers map an input function to the solution field. In each case, derivatives of give the physics loss , which is added to a data loss; the parameters are updated by backpropagation until .
with edge functions , where are spline basis functions and are trainable coefficients [50].
In a physics-informed KAN (PIKAN), this representation replaces the MLP ansatz of a PINN, , with now denoting the spline coefficients. The residual is formed exactly as in equation (2), and training minimizes
PIKANs therefore retain the physics-constrained formulation of PINNs while exchanging the solution representation. Recent work addresses their computational and optimization challenges through efficient-KAN implementations, wavelet-based bases, adaptive grid refinement and augmented-Lagrangian optimization [49–51]. Systematic comparisons of KAN and MLP representations for differential equations suggest that the benefits are problem dependent, which calls for careful benchmarking [52, 53].
Page 5 of 51
2.2. Physics-informed computer vision
CNNs are the natural architecture for grid-based scientific and imaging data. Physics-informed CNNs (PICNNs) [34] exploit this by approximating differential operators directly on discrete image or feature maps with convolution kernels or finite-difference stencils [54], rather than by automatic differentiation of a coordinate-based network [45]. This makes physical constraints compatible with standard convolutional pipelines. An early hybrid framework of this kind, introduced by Fang [55], replaced automatic differentiation with approximations of differential operators for PDE-constrained learning.
Physics-informed computer vision (PICV) generalizes the idea to vision-based learning, requiring predictions to be consistent with the imaging physics or governing equations. Let be an observed image and the predicted physical field. The objective combines the image-analysis task with a physics penalty,
where . On a regular grid with spacings , and , central differences give
with analogous expressions in y. These are equivalent to fixed convolution kernels, for example
and their transposes and in the second direction. For dynamic data, temporal derivatives follow from consecutive frames, using either a forward difference, , or a higher-order central difference, , which correspond to the one-dimensional kernels and . For the diffusion equation , the discrete convolutional residual is therefore
where denotes convolution operation. This residual enters and is optimized jointly with the task objective, so that differential operators are evaluated inside the CNN pipeline without altering its computational structure.
Zhao et al. [34] used this approach for label-free thermal surrogate modeling, showing that physics-guided learning can be effective without explicit supervision. Ren et al. [54] extended it to convolutional-recurrent encoder-decoder architectures for spatiotemporal dynamical systems. These developments are particularly relevant to oncologic imaging, where acquisition fidelity and biological consistency are essential for tumour characterization. Representative applications include physics-informed CT harmonization for stabilizing quantitative biomarkers across scanners [56], physics-guided diffusion MRI denoising for prostate tumour imaging [57], and CNN-based reconstruction with MRI k-space consistency for accelerated acquisition [18]. More broadly, embedding acquisition physics in convolutional architectures supports robust reconstruction and analysis when training data are limited.
2.3. Physics-informed neural operators
Operator-learning methods [58, 59] learn mappings between function spaces rather than individual solutions, and can therefore generalize across physical parameters, acquisition settings or patient-specific conditions. DeepONet [31] introduced this paradigm through a branch network that encodes the input function and a trunk network that represents the evaluation coordinates. Neural operators extend the concept by learning global solution operators through parameterized integral or spectral transformations, as in Fourier neural operators (FNOs) [60, 61]. Physics-informed DeepONets show that governing equations can supplement or even replace paired training data in this setting [62].
The physics-informed neural operator (PINO) combines operator learning with PDE constraints. For a dynamical system
Page 6 of 51 where is the initial condition and a spatial differential operator, the goal is to learn for with a neural operator , typically an FNO. In contrast to a PINN, which fits one PDE instance, PINO represents a whole family of solutions. The PDE, boundary and initial-condition constraints form
Given paired data , PINO adds the supervised loss to the expected PDE loss :
and either term may be used alone when data or observations are unavailable. A distinctive feature is multi-resolution enforcement of physics: the operator can be trained on coarse solution data while the residual is evaluated on a much finer grid.
PINO also supports instance-wise fine-tuning. A pretrained operator provides the initial ansatz for a specific initial condition, which is then refined using the PDE residual. An anchor loss prevents excessive drift from the learned operator, giving
and progressive grid refinement further improves accuracy at high resolution. The resulting two-stage strategy, which pairs coarse data and a high-resolution PDE constraint for operator learning with a PDE loss and anchor loss for fine-tuning, is well suited to personalized modeling.
In oncology, this separation maps naturally onto patient-specific dynamics such as tumour growth, diffusion, invasion and treatment response. The initial tumour state and biological parameters are the operator input, the predicted longitudinal tumour state is the output, and a reaction–diffusion or other mechanistic growth model supplies the PDE residual. Operator learning thus captures a family of tumour dynamics, while fine-tuning adapts it to an individual patient. Physics-informed operator methods further offer opportunities for generalized inverse problems, including rapid reconstruction, parameter estimation and adaptation across imaging protocols [63, 64].
2.4. Physics-informed generative models
Generative models learn a distribution over solution fields rather than a single deterministic prediction, which makes them natural tools for ill-posed problems, sparse or noisy observations and uncertainty quantification. Physics-informed generative models (PIGMs) impose the governing equations on the generated samples, so that every draw from the learned distribution is both statistically plausible and physically consistent [65–68]. Let denote the conditioning information (for example sparse measurements, an initial condition or an image) and the generated field. The residual of equation (2) is evaluated on each sample, and its expectation defines the physics loss
which is added to the generative objective of the chosen model class. The families differ in where the distribution is represented and how it is sampled.
Bayesian PINNs (B-PINNs) [69] are the most direct probabilistic extension of the PINN and can be regarded as generative in the classical statistical sense. Network parameters and physical variables are treated as random variables with a prior , and the likelihood combines the observations, the physics residual and the initial and boundary conditions,
Samples , obtained by Hamiltonian Monte Carlo, variational inference or deep ensembles, induce a distribution over solution fields and propagate data and model uncertainty through the governing physics [70, 71]. This gives robustness to noise, sparsity and model mismatch. B-PINNs perform instance-specific inference in weight
Page 7 of 51 space, which is principled but costly to sample and difficult to scale to high-dimensional parameter spaces. Deep generative models take the complementary approach of learning an explicit, amortized sampler over fields.
In physics-informed generative adversarial networks (PIGANs), a generator maps a latent variable and the condition to a field and is trained against a discriminator that distinguishes generated fields from reference data. The generator is additionally penalized for violating the physics,
where . The residual is computed by automatic differentiation of the generator output, and sampling different latent variables yields an ensemble of physically consistent solutions from which predictive uncertainty can be estimated [65, 69]. Adversarial training is, however, prone to instability and mode collapse, and is sensitive to the balance between the adversarial and physics terms.
Diffusion and score-based models currently offer the most flexible route. A forward noising process , with and diffusion time , is inverted by a network , equivalently a score , trained by denoising score matching,
Samples are generated by integrating the reverse-time stochastic or probability-flow differential equation from noise to data. Physics enters in two complementary ways. During training, the one-step denoised estimate is passed through the residual,
so that the learned distribution concentrates on solutions of the PDE [67]. During sampling, the physics acts as guidance. For observations , with an observation operator, the conditional score is approximated by
where and set the guidance strengths. A single pretrained prior can then serve both forward and inverse problems, such as reconstruction from sparse sensors or recovery of unknown coefficients, without retraining [66, 72]. Flow-matching formulations follow the same pattern with a learned velocity field in place of the score and allow faster sampling.
These formulations are complementary to the architectures discussed above: the network, generator or denoiser can itself be an MLP, a KAN, a CNN or a neural operator, with the probabilistic layer supplying a description of uncertainty. Compared with B-PINNs, deep generative models scale more readily to high-dimensional, image-like outputs and sample quickly once trained, at the price of requiring training data and, for diffusion models, iterative sampling. Open challenges include the cost of sampling, the need to differentiate the residual through the sampler or denoiser, the sensitivity of physical consistency to the guidance weights, and the fact that soft constraints guarantee consistency only approximately. Hard-constraint projection and consistency-based sampling are active responses to these issues. Recent advances in scalability and reliability are making these approaches increasingly attractive for high-stakes settings such as medical imaging, disease modeling and treatment planning .
In oncology, PIGMs offer a route to uncertainty-aware, patient-specific inference. Conditioned on sparse longitudinal imaging, a Bayesian or generative physics-informed model can sample an ensemble of tumour states and reaction-diffusion parameters that are consistent with both the scans and the mechanistic growth law, thereby quantifying uncertainty in predicted progression or treatment response. The same mechanism supports physically constrained image reconstruction, synthesis and super-resolution when acquisition is limited, and complements operator learning by providing calibrated distributions rather than point forecasts. By reporting predictive confidence alongside physical consistency, physics-informed generative learning is an important step towards trustworthy scientific machine learning and clinically deployable PIDL systems.
Evolution and landscape of PIDL: Tables 1 and 2 trace the field from early neural PDE solvers and the original PINN to scalable operator learning and to hybrid, transformer-based, graph-based and uncertainty-aware frameworks.
Page 8 of 51
Table 1 Evolution of physics-informed deep learning and related scientific machine learning approaches: foundational developments.
| Models | Key Technology | Main Contributions |
|---|---|---|
| Neural PDE Solvers [76] | Neural-network trial solutions | Introduced neural-network-based trial solutions for differential equations, with constraints incorporated into the solution representation. |
| SINDy [77] | Sparse regression | Identified governing equations from data by sparse regression over a library of candidate nonlinear terms. |
| Deep Ritz Method [78] | Variational neural solver | Reformulated PDE solution as variational energy minimization and optimized the corresponding functional using neural networks. |
| Deep Galerkin method [79] | Residual-based neural solver | Minimized the PDE residual and boundary/initial losses on randomly sampled points for mesh-free, high-dimensional PDE solving. |
| PINNs [14] | PDE-residual-constrained learning | Established the neural framework by embedding governing differential equations into network training through physics-based residual losses. |
| HNNs [80] | Hamiltonian-structured learning | Learned dynamical systems through Hamiltonian representations while preserving the underlying physical structure and conservation properties. |
| fPINNs [81] | Fractional differential constraints | Extended physics-informed learning to fractional differential equations by incorporating fractional operators into the residual formulation. |
| Adaptive activation PINNs [19, 20, 25] | Physics-informed neural network | Introduced trainable scaling parameters in activation functions to accelerate convergence and improve PINN training. |
| LNNs [82] | Lagrangian-structured learning | Learned Lagrangian formulations directly from observational data, providing physically structured modeling of dynamical systems without explicitly specifying canonical momenta. |
| cPINNs [29] | Conservative domain decomposition | Introduced domain decomposition with interface conditions to improve the treatment of conservation laws and discontinuous solutions. |
| XPINNs [28] | Space-time domain decomposition | Generalized domain decomposition for PINNs by independently training neural networks over multiple space-time subdomains. |
| hp-VPINNs [83] | Variational formulation and hp-refinement | Combined variational PINNs with domain decomposition and hp-refinement to improve numerical approximation of PDE solutions. |
| B-PINNs [69] | Bayesian physics-informed learning | Introduced Bayesian inference into PINNs to quantify uncertainty in PDE solutions and inferred physical parameters. |
| gPINNs [84] | Gradient-enhanced residual learning | Augmented the conventional PINN objective with gradients of the PDE residual, providing additional differential constraints during training. |
| Norm-PCGrad [85] | Gradient-conflict mitigation | Extended PCGrad with gradient normalization to obtain conflict-free update directions for PINN and PIKAN training, including domain-decomposed settings such as XPINN. |
Fig. 3 groups the major architectural families: domain-decomposition and adaptive PINNs, spectral and operator-learning approaches, transformer-based and multi-physics architectures, and physics-informed CNNs and graph neural networks. Taken together, they show a progression from solving one equation at a time towards learning reusable, uncertainty-aware models that integrate data and physics at scale.
Page 9 of 51
Table 2 Recent developments in physics-informed learning, neural operators and emerging physics-informed architectures.
| Models | Key Technology | Main Contributions |
|---|---|---|
| DeepONet [86] | Branch-trunk operator learning | Learned nonlinear mappings between input and output functions using branch and trunk networks, establishing a general neural-operator framework. |
| FNO [87] | Fourier-space operator learning | Learned mappings between function spaces through Fourier-domain transformations, enabling efficient operator approximation across discretizations. |
| Physics-informed DeepONet [62] | Operator learning | Incorporated PDE residual constraints into DeepONet training to learn solution operators with little or no paired data. |
| PINO [88] | Physics-informed neural operators | Combined neural-operator learning with PDE constraints, enabling solution operators to learn from available data while enforcing governing equations at potentially higher resolutions. |
| Geo-FNO [89] | Geometry-aware Fourier operators | Extended Fourier neural operators to geometrically complex and non-Cartesian domains through geometry-aware transformations. |
| FourCastNet [90] | Large-scale Fourier operator learning | Demonstrated scalable Fourier neural operators for high-resolution global weather forecasting, illustrating the use of neural operators for large-scale scientific modeling. |
| Neural Operator [58] | Function-space operator learning | Established a general framework for learning mappings between infinite-dimensional function spaces and emphasized discretization-invariant operator learning. |
| PINNsFormer [37] | Transformer-based physics-informed learning | Introduced transformer-based physics-informed learning using tokenized space-time representations and self-attention for PDE solution modeling. |
| PINNacle [53] | Benchmarking and evaluation | Provided a systematic benchmark for evaluating PINNs across PDEs, architectures, optimization strategies and numerical settings. |
| PIKANs [91] | KAN-based physics-informed learning | Integrated governing-equation constraints with Kolmogorov-Arnold networks using learnable univariate functions within the network representation. |
| Multi-physics PINNs [92] | Coupled physical constraints | Extended physics-informed learning to coupled physical systems by jointly enforcing multiple interacting governing equations and interface constraints. |
| Physics-informed diffusion models [67] | Physics-constrained generative learning | Integrated physical constraints with diffusion-based generative models for inverse problems, reconstruction and scientific simulation. |
| Uncertainty-aware and multi-fidelity PINNs [93] | Multi-fidelity and probabilistic learning | Combined heterogeneous-resolution observations, physical constraints and uncertainty-aware formulations for learning under limited or noisy measurements. |
3. Motivation for PIDL in Oncology
Pure data-driven deep learning has become central to computational oncology, enabling the transformation of raw, noisy measurements into clinically actionable representations. By learning hierarchical features directly from data, deep neural networks have advanced tasks such as tumor segmentation, cancer detection and classification, image-guided interventions, and automated annotation. The following subsections review the evolution of major deep learning architectures and highlight the fundamental challenges that motivate the adoption of physics-informed deep learning.
3.1. Data-driven deep learning in oncology: An overview
CNN-based architectures [94–96] established the foundation for tumor characterisation and quantitative radiomic analysis by learning clinically relevant patterns from oncologic images. Their ability to capture tumor morphology, intensity, texture, and spatial heterogeneity has supported key clinical tasks, including tumor detection, segmentation, classification, grading, and quantitative assessment of treatment response. In particular, encoder-decoder architectures
Page 10 of 51

Figure 3: Overview of major physics-informed deep learning architectures and their key characteristics.
such as U-Net and its variants have facilitated precise delineation of tumor boundaries and subregions, supporting clinical applications in diagnosis, disease assessment, prognosis, and treatment planning. Subsequent advances in transformer-based and state-space architectures [97, 98] have further enhanced global contextual modeling and feature representation for complex oncologic imaging tasks.
U-Net and its variants in oncology: U-Net [5] and its variants form the foundation of medical image segmentation, implementing encoder-decoder structures with skip connections to preserve spatial details. The baseline U-Net achieves strong performance across modalities such as MRI, CT, X-rays, and microscopy [8, 99]. Subsequent variants improve efficiency and representation, lightweight models such as Half-U-Net [100] reduce computational cost while maintaining accuracy, whereas architectures like DoubleU-Net [101] enhance feature learning through stacked networks with pretrained encoders and multi-scale context modules. Multi-scale designs, such as EMED-UNet [102], further improve feature extraction through parallel encoder-decoder pathways. Attention-based extensions, including DSCA-Net [103], incorporate spatial and contextual attention mechanisms to refine segmentation while reducing the number of parameters. Enhanced skip connections, as in U-Net v2 [104], improve semantic feature fusion, while recurrent and residual variants such as R2U-Net [105] capture complex dependencies for improved performance in lesion segmentation tasks. These developments demonstrate the adaptability of U-Net architectures in achieving accurate, efficient, and robust tumor segmentation.
Transformer-enhanced and hybrid CNN architectures in oncology: While CNNs are effective for local feature extraction, their limited ability to capture long-range dependencies has driven the development of hybrid and transformer-based architectures [106–108]. Hybrid models such as CoTrFuse [109] combine CNN encoders [110] with Swin Transformers [111] to integrate local and global features, improving segmentation performance. Similarly, MedFuseNet [112] employs parallel convolutional and transformer branches with attention mechanisms, including atrous spatial pyramid pooling and cross-attention fusion, to enhance feature representation. Transformer-based models, such as SegFormer3D [113], extend hierarchical self-attention to volumetric data, achieving efficient and accurate 3D segmentation with reduced computational cost. These architectures integrated global contextual representation learning with long-range dependency modeling, representing a shift from local feature extraction to context-aware tumor analysis in oncologic imaging [114, 115].
Page 11 of 51
3.2. Data-driven deep learning in oncology: Limitations
Despite significant progress, deep learning-based methods face fundamental challenges due to their heavy reliance on large, annotated datasets and their inability to intrinsically incorporate governing physical principles. The main challenges are described as follows:
Data availability and domain generalisation: Data scarcity remains a fundamental challenge in computational oncology, limiting model performance, generalisation, and clinical reliability. High-quality annotations require expert clinicians to delineate complex anatomical and pathological structures, often in volumetric data [116, 117]. This process is time-consuming, expensive, and subject to inter-observer variability, resulting in limited and inconsistent labelled datasets [118, 119]. In parallel, strict privacy regulations such as health insurance portability and accountability act and general data protection regulation restrict data sharing across institutions, leading to fragmented datasets and reduced diversity. Additionally, variations in scanner hardware, imaging protocols, acquisition settings, and patient demographics introduce significant domain shifts, often leading to poor generalisation of models beyond the training distribution [120]. Furthermore, the high cost and long acquisition times associated with imaging modalities such as MRI and PET further constrain the collection of large, representative datasets.
Model interpretability: Model interpretability remains a fundamental challenge for conventional data-driven deep learning in cancer research, as the learned decision-making process is largely opaque, limiting clinical trust, transparency, and adoption [121, 122]. To improve model explainability, numerous post hoc explainability techniques for artificial intelligence have been proposed. Among these, saliency-based methods improve explainability by translating a model's prediction into a spatial map of feature importance. For example, gradient-weighted class activation mapping uses the gradients of a target class to weight intermediate feature maps, thereby highlighting image regions that most strongly influence the predicted class. Overlaying these maps on the original scan allows clinicians to assess whether the model relies on clinically plausible structures, such as a tumor or its surrounding tissue, or on irrelevant background features and imaging artifacts [123, 124]. This provides an intuitive, case-specific explanation of the model's behaviour, although the highlighted regions indicate model sensitivity rather than causal importance.
Absence of physical consistency: Biomedical imaging modalities, such as MRI, CT, X-ray, ultrasound, and optical imaging, are intrinsically governed by well-established physical principles, commonly expressed as forward models or PDEs. Pure data-driven deep learning approaches, despite their success in image reconstruction, segmentation, and classification, often fail to explicitly enforce governing laws, resulting in outputs that may be visually plausible yet physically inaccurate or inconsistent. Thus, while deep learning has greatly enhanced oncologic imaging pipelines (segmentation, detection, prognosis), its limitations motivate the incorporation of physics priors to improve generalisation and consistency. As illustrated in Fig. 4, purely data-driven learning produces predictions that lack explicit physical consistency in oncological processes.
4. Task-oriented review of PIDL for oncologic applications
This section reviews the development of PIDL across a broad range of oncologic tasks, spanning image reconstruction, disease characterization, tumor progression modeling, treatment planning, and therapy monitoring. We first outline the oncologic data analysis (ODA) pipeline, which provides the conceptual framework for organizing the task-oriented PIDL applications discussed throughout this section.
ODA pipeline: The end-to-end ODA workflow comprises five interconnected stages: data acquisition, data preprocessing, model design, model training, and task-specific inference. During data acquisition, physics-informed approaches incorporate imaging acquisition models and measurement physics, including MRI signal encoding, CT attenuation, PET emission, ultrasound propagation, and thermal diffusion, to improve data fidelity and mitigate acquisition-related artifacts. During pre-processing, physics-driven methods support image denoising, registration, super-resolution, and artifact correction while preserving anatomically and physiologically meaningful information. At the model-design stage, physical and biological priors are incorporated into network architectures to promote robust feature representation and capture tumor-specific characteristics. During model training, governing equations, imaging forward operators, conservation laws, and physiological constraints are integrated into the optimization objective through physics-informed loss functions, improving data efficiency and physical consistency. Finally, task-specific inference encompasses downstream oncologic tasks, including image reconstruction, segmentation, tumor detection.
Page 12 of 51

Figure 4: Illustration of the lack of physical consistency in purely data-driven deep learning for oncologic imaging. Although the predicted outputs may appear visually plausible, they can violate image-formation physics, conservation principles, and physiologically feasible ranges, potentially introducing artifacts and reducing clinical reliability. Representative input images are adapted from [125].
and classification, quantitative biomarker estimation, treatment planning, therapy-response assessment, and disease-progression modeling. Fig. 5 illustrates this five-stage ODA pipeline.
A solid tumor is not merely a biological mass of proliferating cells but a complex dynamical system governed by interacting physical and biological processes. Its microenvironment and physiological behavior can be described using principles from classical mechanics, fluid dynamics, and thermodynamics [126]. For example, the spatial distribution of vital nutrients, such as oxygen and glucose, is governed by reaction-diffusion processes, while limited diffusion in tissue can produce concentration gradients and hypoxic regions. At the macroscopic scale, tumor expansion is commonly described using phenomenological growth laws, such as logistic and Gompertzian kinetics, as well as spatial and continuum-mechanical models [127]. Tumor angiogenesis further alters vascular transport and tissue perfusion, while the tumor microenvironment behaves as a porous medium in which interstitial fluid flow can be described using Darcy's law. Such transport mechanisms contribute to elevated interstitial fluid pressure and influence the distribution of therapeutic agents within tumors [128]. These coupled physical and biological processes provide the mechanistic basis for incorporating physics into oncologic computational modeling.
Tumor-growth modeling has consequently evolved from classical phenomenological descriptions toward spatially resolved, mechanistic, and patient-specific formulations. Classical exponential, logistic, and Gompertz models describe population-level growth, whereas subsequent models incorporate vascular regulation, spatial invasion, chemotaxis, interstitial transport, tumor-tissue interfaces, and vascular-network dynamics. More recent approaches further integrate longitudinal patient-specific observations and AI-based parameter estimation. Representative developments across these modeling levels are summarized in Table 3.
Traditional data-driven deep learning models learn these relationships primarily from observed data, often requiring substantial training datasets to capture complex biological and physical dependencies. PIDL instead incorporates known physical laws and mechanistic constraints directly into the learning process. Governing equations, imaging forward operators, conservation laws, and physiological relationships can be embedded into the training objective, penalizing predictions that violate established physical or biological constraints. By coupling data-driven
Page 13 of 51

Figure 5: Overview of the physics-informed deep learning workflow for oncologic imaging.
representation learning with mechanistic knowledge, PIDL provides a framework for data-efficient and physically consistent modeling of oncologic processes.
For each task, we discuss the relevant physical or biological constraints, representative PIDL strategies, and their clinical relevance. Evaluation across tasks combines conventional quantitative metrics with clinically meaningful endpoints, including image fidelity, lesion detectability, biomarker preservation, diagnostic performance, and therapeutic accuracy. Task-specific datasets, evaluation criteria, and clinical considerations are discussed within the corresponding subsections.
4.1. Image reconstruction
Image reconstruction is a foundational computational step in the oncologic imaging workflow, providing the anatomical and functional images required for downstream tasks. Because clinical modalities measure indirect physical signals arising from interactions between imaging systems and tissue, recovering diagnostically meaningful images requires solving an inverse problem that is typically ill-posed owing to undersampling, measurement noise, detector imperfections, and dose or time-limited acquisition. Image reconstruction was among the earliest medical-imaging tasks to benefit from physics-informed deep learning, with imaging physics incorporated into network optimisation to improve reconstruction fidelity and quantitative accuracy. The acquisition is modeled through the imaging forward operator [13]:
where is the unknown image, the measurements, the modality-specific forward operator, and the noise; the goal is to recover consistently with both the data and the imaging physics.
In MRI, the forward model comprises Fourier encoding, sampling trajectories, and coil sensitivity profiles, with measurements corresponding to undersampled k-space; physics-informed reconstruction imposes Fourier-domain data-consistency constraints to suppress aliasing while preserving fine structure [39, 142]. In CT, image formation follows the Beer-Lambert law and the Radon transform. Specifically, the measured X-ray intensity I along a path l is related to the incident intensity and the linear attenuation coefficient through the line-integral model
Page 14 of 51
Table 3
Evolution of mathematical models for tumor-growth modeling, from classical phenomenological formulations to recent patient-specific mechanistic-AI frameworks.
| Modeling level | Tumor-growth model | Mathematical formulation | Coefficients and variables | Biological mechanism | Reference |
|---|---|---|---|---|---|
| Population-level | Exponential growth | : tumor population/volume; : intrinsic proliferation rate | Unconstrained proliferation under effectively unlimited resources | [129] | |
| Population-level | Logistic growth | : tumor population/volume; : proliferation rate; : carrying capacity | Resource limitation and finite carrying capacity | [130] | |
| Population-level | Gompertz growth | : tumor population; : reference population; : growth coefficient; : growth-deceleration coefficient | Progressive growth-rate deceleration | [131] | |
| Population-vascular | Dynamic carrying-capacity model | : tumor volume; : vascular carrying capacity; : tumor growth parameter; : vascular stimulation rate; : endogenous vascular inhibition parameter; : spontaneous vascular loss rate; : antiangiogenic drug concentration; : treatment coefficient | Angiogenic regulation of tumor carrying capacity | [132] | |
| Spatial | Fisher-Kolmogorov reaction-diffusion | : tumor-cell density; : diffusion tensor; : proliferation rate; : carrying capacity | Tumor proliferation and spatial invasion | [133–135] | |
| Spatial-invasive | Keller-Segel chemotaxis/haptotaxis | : tumor-cell density; : diffusivity; : chemical concentration; : ECM concentration; : chemotactic sensitivity; : haptotactic coefficient | Directed migration along chemical and ECM gradients | [136] | |
| Biomechanical | Interstitial fluid transport / Darcy model | : interstitial fluid velocity; : hydraulic conductivity; : interstitial fluid pressure; : fluid exchange term | Interstitial fluid pressure and fluid-solid transport | [137] | |
| Vascular-multiscale | 3D-1D vascular tumor-growth model | : tissue/tumor state; : tissue diffusivity; : nutrient concentration; : vascular flow; : vascular pressure | Coupled tumor growth, vascular-network evolution, nutrient transport, and interstitial flow | [138] | |
| Multiphase | Phase-field tumor-growth model | : tumor phase/order parameter; : mobility; : chemical potential; : free-energy density; : interface-width parameter | Tumor-tissue interface evolution, adhesion, and multi-species tumor dynamics | [139] | |
| Mechanistic-patient-specific | Imaging-informed biomechanistic model | : tumor-cell density; : tumor-cell diffusivity; : net proliferation rate; : tissue carrying capacity; : longitudinal imaging observations | Patient-specific calibration and forecasting of tumor growth | [140] | |
| Mechanistic-AI | Patient-specific mechanistic-AI framework | : tumor state; : patient-specific model parameters; : patient-specific data; : neural parameter estimator | AI-assisted parameterization of mechanistic tumor models using patient-specific data | [141] |
where the logarithmic projection represents the accumulated attenuation along the X-ray path [143]. In discrete form, this forward model can be expressed as , where denotes the attenuation coefficient distribution, represents the projection data, and is the system matrix determined by the scanning geometry [143]. PIDL therefore integrates projection operators and attenuation physics to recover high-quality images from sparse-view or low-dose data [143, 144]. PET reconstruction depends on radioactive decay, detector response, attenuation correction, and Poisson statistics, thereby requiring the preservation of quantitative biomarkers such as standardised uptake values, whereas ultrasound and photoacoustic imaging exploit acoustic wave propagation, beamforming, and optical point-spread functions as physical constraints.
Page 15 of 51
In MRI, Fourier encoding and data-consistency layers enable highly accelerated reconstruction while preserving anatomical detail [39], and self-supervised frameworks reduce dependence on fully sampled references, with clinical studies reporting shorter acquisition without loss of lesion detectability [145, 146]. In CT, embedding Radon-transform physics improves sparse-view and low-dose reconstruction and, in dual-energy CT, yields more accurate material decomposition [143]. In PET, modeling photon emission, attenuation, and detector response improves low-count reconstruction while preserving metabolic quantification [147]; and in ultrasound tomography the acoustic wave equation has been embedded in deep-unfolded full-waveform inversion to recover quantitative sound-speed maps [148, 149].
Datasets and evaluation: PIDL reconstruction is benchmarked on fastMRI [150], the American association of physicists in medicine Low-Dose CT Challenge [151], and TCIA collections [152], with numerical phantoms (BrainWeb, Shepp-Logan) [153, 154] for controlled evaluation; image-quality metrics [155] are increasingly complemented by lesion conspicuity, tumor-volume agreement, and biomarker preservation. Overall, PIDL improves fidelity under accelerated, sparse-view, or low-dose acquisitions, though performance depends on forward-model accuracy and adds computational cost.
4.2. Image denoising
Image denoising suppresses acquisition noise while preserving tumor morphology, tissue heterogeneity, and quantitative biomarkers needed for lesion detection, delineation, radiomics, and longitudinal assessment. It is especially important in oncology, where dose- and time-reduced protocols (low-dose CT, low-count PET, accelerated and diffusion-weighted MRI) elevate noise and degrade quantitative reliability. Given an observed image
with the noise-free image, the forward operator, and modality-dependent noise, PIDL addresses this by jointly suppressing noise and enforcing consistency with the acquisition physics.
The origin of noise is modality-specific. In low-dose CT, reduced exposure lowers detected photon counts: mean transmitted intensity follows the Beer-Lambert law [156, 157], while photon-count fluctuations are Poisson-distributed [158], impairing detection of small or low-contrast lesions. In PET, lower activity or shorter scans yield low-count, Poisson-dominated images that bias standardized uptake values; MRI is affected by Rician noise from complex Gaussian k-space noise, with further artifacts from parallel imaging, field inhomogeneity, and acceleration that influence quantitative MRI (DWI, DCE-MRI, DSC-MRI, relaxation mapping).
PICNNs [54] encode Poisson or Rician statistics through likelihood-based losses, and model-based unrolled frameworks [13] alternate physics-constrained data consistency with learned denoising. PINNs cast denoising as a PDE-constrained problem via nonlinear diffusion (heat, Perona-Malik) [159]. A representative nonlinear diffusion model is given by
where denotes the evolving image intensity, represents the image gradient, and is an edge-stopping diffusion coefficient that reduces diffusion across strong intensity gradients. In the physics-informed formulation, the neural network approximates while automatic differentiation is used to enforce the PDE residual and the associated initial and boundary conditions. This formulation enables noise suppression while retaining important image edges and structures [159]. Diffusion-probabilistic and transformer models embed acquisition physics into score estimation and attention for robustness at very low dose. Representative measurement-formation approaches include count-domain processing for low-dose CT [160], Poisson-likelihood model unrolling for PET [161], and joint signal/acquisition constraints for quantitative MRI [162].
Datasets and evaluation: Common resources include the American association of physicists in medicine-Mayo Low-Dose CT Challenge [163], TCIA PET/CT collections [152, 164], and BrainWeb phantoms [153]. Beyond PSNR/SSIM/RMSE, evaluation increasingly emphasizes modality-specific endpoints (lesion detectability and contrast-to-noise in CT, SUV recovery in PET, ADC and parameter-map fidelity in MRI) and radiomic reproducibility [165], together with downstream effects on segmentation, planning, and response prediction. A recurring limitation is the use of simplified, stationary noise models that poorly represent scanner- and acquisition-dependent, spatially varying clinical noise.
Page 16 of 51
4.3. Image registration
Registration establishes spatial correspondence between images acquired at different times, modalities, or physiological states, supporting PET-CT and PET-MRI fusion, longitudinal monitoring, image-guided intervention, adaptive radiotherapy, and contour propagation [166, 167]. It is challenging because respiration, repositioning, growth, edema, surgery, and treatment remodeling produce complex non-rigid deformations that generic smoothness regularization may render mechanically implausible [166, 168].
PIDL embeds biomechanical principles into deformation estimation. With fixed and moving images and , respectively, and transformation , the objective function is
where measures similarity between and , penalises biomechanical violations such as lack of elastic equilibrium, inconsistent stress-strain relations, nonphysical volume changes, or excessive strain energy, and controls deformation irregularity and topology violations [169–172]. Several strategies exist. PINN-based methods represent with a network and evaluate governing-equation residuals by automatic differentiation; Min et al. [170] used a three-dimensional linear-elastic model for prostate MR-to-ultrasound registration. The biomechanical constraint is governed by the linear-elasticity system comprising the strain-displacement relation, static equilibrium, and constitutive stress-strain relation:
where is the displacement field, is the infinitesimal strain tensor, is the Cauchy stress tensor, and and are the Lamé parameters determined by the tissue Young's modulus and Poisson's ratio. In the PINN formulation, automatic differentiation evaluates the spatial derivatives in these equations, and the resulting equilibrium and constitutive residuals are incorporated into the training loss to constrain the predicted deformation to be biomechanically plausible [170]. Physics act as regularization: WarpPINN [171] enforced myocardial near-incompressibility in cine-MR registration, a principle transferable to respiratory and organ deformation in oncology. Hybrid approaches couple networks with finite-element or continuum-mechanics solvers that refine a learned deformation [169], while Neural-ODE formulations model registration as continuous coordinate evolution [173]; Amiri-Hezaveh et al. [172] proposed a predictor-corrector neural-ODE enforcing large-deformation elasticity and growth mechanics. Such biomechanical constraints are most valuable when intensity correspondence is weak (PET-CT, PET-MRI, MR-ultrasound) and for modeling mass effect, edema, and postoperative change, although tissue appearing or disappearing through resection or necrosis violates the smooth one-to-one assumption.
Registration is assessed with target-registration error, Dice, Hausdorff distance, inverse-consistency error, and the Jacobian determinant (non-positive values indicate folding), using landmark datasets such as DIR-Lab 4D-CT [174, 175]; physics-informed methods additionally report volume-change plausibility, strain consistency, and organ-at-risk propagation [166, 167].
4.4. Biomechanical motion correction
Respiratory, cardiac, and involuntary motion introduces blurring, misregistration, and artifacts in oncologic CT, MRI, and PET, degrading tumor delineation, quantitative imaging, and radiotherapy planning. Unlike similarity-driven registration networks, PIDL regularizes deformation fields with tissue mechanics, mass preservation, and organ-motion dynamics. Typical physical constraints include respiratory-motion periodicity, tissue incompressibility, biomechanical equilibrium, temporal smoothness, and conservation of organ volume. Building on unsupervised dense-deformation estimation [176], Jian et al. in [177] introduced a weakly supervised, biomechanically constrained CT-MRI framework that preserves anatomical integrity, and Boysen et al. [178] proposed a biophysics-enhanced neural representation for patient-specific respiratory motion that generates temporally coherent, realistic trajectories.
A suitable governing formulation [178] for respiratory motion represents the deformation as the flow generated by a time-dependent velocity field. Specifically, the particle trajectory satisfies the transport system
Page 17 of 51 where denotes the position at time of a tissue point initially located at at time , is a neural-network parameterized time-dependent velocity field, and denotes the respiratory surrogate signal. The deformation between two respiratory states can consequently be obtained by integrating the velocity field,
In a physics-informed or physics-regularized neural framework, the network is trained to satisfy the transport equation while simultaneously matching the observed image pairs and physiological constraints. This formulation provides a continuous and diffeomorphic representation of respiratory motion and allows motion to be estimated between arbitrary respiratory phases [178]. Complementary physics-constrained registration and motion-aware radiotherapy studies further demonstrate the value of coupling biomechanics with deep learning for motion compensation and adaptive planning [167, 179].
4.5. Super-resolution
Super-resolution (SR) reconstructs a high-resolution image from low-resolution acquisitions, recovering detail lost to hardware, protocol, or image-formation limits. In oncology, resolution affects small-lesion detection, boundary delineation, visualisation of infiltrative disease, characterisation of heterogeneity, and radiomic reproducibility, with the potential to improve micrometastasis detection and response assessment. Unlike interpolation, medical SR is an ill-posed inverse problem in which recovered high-frequency content must remain physically consistent with acquisition. The degradation is commonly written
where H is the system operator (e.g., point-spread function), D downsampling, and noise; PIDL embeds these operators via data-consistency constraints, point-spread function (PSF) or sampling models, and governing equations, discouraging hallucinated structure.
Paradigms include model-based networks embedding forward and adjoint operators, physics-informed CNNs encoding blur or PSF models, PINNs posing SR as a PDE-constrained problem, and diffusion, GAN, and transformer models augmented with physics-guided losses; multi-input frameworks use CT or MRI priors to guide SR of functional PET or perfusion imaging. Physics-informed super-resolution can be used to recover high-resolution spatial and temporal information while constraining the reconstruction using modality- or tissue-specific physical models. The PhySR [180] architecture provides a representative framework by combining ConvLSTM-based temporal refinement, residual spatial reconstruction, and PDE-based physics constraints, as shown in Fig. 6.

Figure 6: Physics-informed super-resolution architecture integrating ConvLSTM-based latent refinement with data and governing-PDE constraints for high-resolution tensor reconstruction [180].
Page 18 of 51
Physics-informed modeling of blood flow: A representative hemodynamic application of physics-informed super-resolution was presented by Fathi et al. [181] for four-dimensional flow MRI. In this setting, a neural network represents the velocity field and pressure while enforcing the incompressible Navier-Stokes equations,
where and denote blood density and dynamic viscosity, respectively. Data-fidelity constraints couple the predicted fields to the measured complex-valued MRI data, whereas the momentum and continuity residuals regularize the reconstruction. The trained network can therefore generate denoised, high-spatial- and high-temporal-resolution velocity and pressure fields without requiring precisely segmented vascular geometry or explicitly prescribed boundary conditions. Although the method was developed and validated for vascular 4D-flow MRI rather than oncologic imaging, the same formulation could be adapted to tumor-associated vessels, where sparse measurements and limited spatial resolution make the recovery of local perfusion and hemodynamic quantities challenging.
A more directly oncologic example was reported by Sainz-DeMena et al. [182], who used a PINN to analyze DCE-MRI while incorporating contrast-agent diffusion and mass conservation into a pharmacokinetic model. Their approach improved the recovery of vascularization parameters from noisy or incomplete data, which is particularly relevant to spatially heterogeneous tumors. Together, these studies illustrate two complementary roles of physics-informed learning, reconstructing blood-velocity fields from flow MRI and estimating tumor microvascular properties from contrast-agent transport.
SR remains comparatively underexplored in oncology: most methods originate in cardiovascular or general imaging and require adaptation to heterogeneous tumor morphology, multimodal protocols, and scarce high-resolution references, and balancing enhancement against physical consistency is difficult at high upsampling factors, where clinically misleading structures may appear. Beyond PSNR/SSIM/NRMSE, evaluation should weigh lesion detectability, boundary accuracy, radiomic preservation, and downstream diagnostic and therapeutic impact.
4.6. Tumor segmentation and boundary delineation
Accurate segmentation underpins diagnosis, radiotherapy planning, surgical navigation, radiomics, and response assessment, delineating primary tumors, metastases, subregions, and organs-at-risk (OARs). It remains difficult because tumors show heterogeneous morphology, infiltrative growth, noise, weak boundaries, and inter-patient variability, especially in glioma, liver, pancreatic, and head-and-neck disease [183]. Unlike generic semantic segmentation, tumor delineation is tied to biological growth and tissue mechanics-proliferation, migration, angiogenesis, edema, and displacement-commonly modeled by reaction-diffusion, biomechanical, conservation, and transport equations [184–186]. Embedding this knowledge encourages biologically plausible boundaries through reaction-diffusion regularization, biomechanical and mass-conservation constraints, physics-guided losses, hybrid CNN-variational or CNN-level-set formulations, PDE-based refinement, and mechanistic simulators for data augmentation [187–189]. A representative governing system [189] is the Fisher-Kolmogorov reaction-diffusion model for tumor cell-density evolution:
where denotes the normalized tumor cell density, is the spatially varying diffusion coefficient describing tumor-cell invasion, is the proliferation rate, is the tissue domain, and is the outward normal to the tissue boundary. The diffusion term models spatial invasion, whereas the logistic reaction term represents tumor proliferation subject to a carrying-capacity constraint. In a physics-informed formulation, the neural network approximates and automatic differentiation evaluates the PDE residual, allowing the predicted tumor distribution and its boundary to remain consistent with the assumed growth dynamics [189]. Fisher-Kolmogorov reaction-diffusion terms let inferred boundaries reflect disease dynamics rather than intensity alone [188, 189], which is especially useful for infiltrative tumors.
El Afari et al. [187] combined U-Net initialization, variational segmentation, and reaction-diffusion modeling in a physics-informed, digital-twin framework that jointly delineates and predicts tumor evolution. Recent work
Page 19 of 51 has extended DynUNet with physics-based regularization for brain-metastasis segmentation by incorporating Fisher-Kolmogorov tumor-growth dynamics and edema-transport constraints into the training objective, as illustrated in Fig. 7 [188]. Beyond overlap metrics (Dice, Jaccard, Hausdorff and surface distance), physics-informed models may report
Physics-Informed DynUNet (PI-DynUNet) Architecture

Conv Blocks: Initial/Output Encoder Decoder Physics
Feature Dimensions: [Batch, Channels, Depth, Height, Width]
Architecture Details
Connections: Forward Skip Physics
Downsampling Factor: 2x per encoder stage
Figure 7: Overview of the PI-DynUNet architecture for brain metastasis segmentation [188].
governing-equation residuals, estimated growth or transport parameters, and prediction of future evolution [187, 189], evaluated on BraTS, LIDC-IDRI, LiTS, KiTS, and TCIA collections. Open challenges include oversimplified reaction-diffusion models that omit necrosis, angiogenesis, hypoxia, immune interaction, mass effect, and treatment change [184]; computationally demanding and potentially non-identifiable patient-specific parameters [185, 189]; rarely quantified uncertainty; and a focus on binary or single-lesion segmentation rather than multiclass, multifocal delineation [183, 189].
4.7. Tumor detection and classification
Detection localizes suspicious lesions and classification assigns clinically relevant labels (benign versus malignant, grade, histology, molecular subtype), supporting diagnosis, staging, treatment selection, and prognosis. Despite strong data-driven computer-aided detection (CADe) and diagnosis (CADx) systems, physics-informed detection and classification are the least developed areas in this review, because these are high-level semantic tasks rather than inverse problems, and governing equations cannot be embedded in the prediction objective as naturally as in reconstruction, quantification, or biomechanical modeling [43].
Physics can nonetheless inform these tasks by supplying quantitative parameter maps as input channels, deriving model-based features, adding auxiliary physiological-estimation objectives, or penalizing inconsistency between predictions and estimated biology, so that decisions depend on proliferation, invasion, transport, vascularity, or
Page 20 of 51 deformation rather than intensity alone. Mechanistic models are a promising route: reaction-diffusion and biomechanical models estimate proliferating and infiltrating cell distributions and disease extension beyond visible abnormalities [185, 186], and patient-specific inverse modeling recovers growth, transport, mechanical, or vascular parameters from longitudinal data [184, 189]. Personalized reaction-diffusion models coupled with networks and multimodal imaging have estimated infiltration and growth [189], and physics-informed segmentation and evolution models yield mechanistic information potentially useful for detection, grading, or distinguishing recurrence from treatment change [187, 188]; however, these studies target segmentation, growth prediction, or parameter estimation rather than lesion-level detection and classification directly.
Evaluation uses sensitivity, specificity, accuracy, F1 score, AUC, and free-response ROC analysis, and should further test consistency with estimated physiological variables, biomarker preservation, and cross-cohort generalization [184, 189]. Because most systems remain data-driven and adding physical variables does not automatically improve accuracy or generalization, rigorous comparison with data-driven baselines, external validation, and uncertainty quantification are needed, along with task-specific physics-informed objectives that directly target lesion detection and diagnostic discrimination.
4.8. Physiological and metabolic quantification
PIDL has become a powerful framework for quantitatively estimating physiological and metabolic biomarkers from oncologic imaging. Early PINNs estimated hemodynamic and perfusion parameters by embedding tracer kinetics and conservation laws, enabling robust recovery of physiologically meaningful biomarkers from dynamic data [190, 191]. Building on this, Sainz et al. [182] incorporated pharmacokinetic transport equations into PINNs for DCE-MRI, improving estimation of vascular permeability, extracellular volume fraction, and perfusion associated with angiogenesis. [192] developed a physics-informed framework for DSC-MRI recovering vascular response functions and perfusion biomarkers, and Fayolle et al. [193] introduced a physics-informed autoencoder for DSC-MRI that leverages analytical perfusion models to derive biomarkers for glioma grading.
Beyond physiological quantification, PIDL supports metabolic characterization through thermal imaging: tumor metabolism and angiogenesis increase local heat generation and alter perfusion, producing thermal signatures captured by infrared thermography [194]. Physics-informed frameworks leverage the Pennes' bioheat equation [195] to relate surface temperature to underlying metabolic and vascular activity. A representative governing equation for tissue temperature is
where is the tissue temperature, and c are the tissue density and specific heat capacity, respectively, k is the thermal conductivity, , , and denote blood density, blood specific heat, and blood perfusion rate, respectively, is the arterial blood temperature, and and represent metabolic and tumor-associated heat-generation terms, respectively. The first term on the right-hand side describes thermal diffusion, the second represents heat exchange between blood and tissue through perfusion, and the final terms account for local metabolic and tumor heat sources. In a physics-informed formulation, the neural network approximates and automatic differentiation evaluates the bioheat-equation residual, while measured surface temperatures can be incorporated to infer unknown thermal or physiological parameters [194, 196]. Early studies modeled heat transport and temperature distributions in breast tissue [197, 198]; Perez-Raya et al. [194] demonstrated PINNs for breast-cancer thermal modeling, and an inverse PINN framework incorporating the Pennes' bioheat equation [195] and infrared thermography inferred tumor-associated heat sources, enabling tumor-size and localization estimation validated against biopsy-confirmed cases [196]. Recently, Das and Scindhiya [199] introduced an adaptive residual-guided domain refinement in PINN approach for precise breast-tumor thermal profiling through bio-thermal modeling. Collectively, these quantify thermophysiological biomarkers of metabolism, vascularity, and perfusion, providing a non-invasive avenue for metabolic assessment and early detection.
4.9. Treatment planning, radiotherapy, and therapy monitoring
Treatment planning and therapy monitoring translate quantitative imaging into personalized therapeutic decisions, including three-dimensional dose estimation, beam optimization, adaptive planning, and longitudinal response assessment. Radiotherapy dose deposition depends on beam energy, attenuation, scattering, tissue composition, patient anatomy, and machine geometry. Conventional planning relies on Monte Carlo or deterministic transport methods, which provide high accuracy but are computationally expensive. In contrast, purely data-driven dose prediction is
Page 21 of 51 computationally efficient but may violate dose-deposition physics and generalize poorly across beam configurations, treatment protocols, and patient anatomies. Physics-informed deep learning (PIDL) addresses this gap by incorporating beam geometry, attenuation, transport approximations, dose-deposition characteristics, and dosimetric constraints into the learning process.
The underlying radiation-transport physics can be described by the steady-state linear Boltzmann transport equation (LBTE) [200], which governs the spatial and angular distribution of photon fluence:
where denotes the angular photon fluence, is the total interaction coefficient, is the differential scattering coefficient, is the spatial position, is photon energy, is the propagation direction, and represents the radiation source. The resulting photon fluence determines energy deposition and absorbed dose, which can be expressed as
where is the scalar photon fluence, is the mass energy-absorption coefficient, and is the local tissue density. In PIDL, these radiation-transport and energy-deposition relationships can be incorporated as physics residuals or soft constraints, thereby encouraging predicted dose distributions to remain consistent with the underlying radiation physics [200].
A representative application is the physics-informed framework of Sun et al. [201], which predicts individual beam-dose distributions for intensity-modulated radiotherapy by incorporating the attenuation characteristics of 6-MV photon beams together with beam-dose, dose-gradient, and anatomical-masking losses. Beam-by-beam prediction and crosshair-sampling analysis further improve the accuracy and interpretability of the predicted dose distributions. Such approaches demonstrate how radiation-transport knowledge can be incorporated into deep neural networks without requiring the network to explicitly replace a full Monte Carlo or deterministic dose calculation.
Beyond dose prediction, PIDL can support treatment-response modeling through physics-informed digital twins that combine imaging-derived biomarkers with mechanistic descriptions of tumor evolution and therapy response. Mechanistic finite-element models of tumor growth and drug interaction provide physically interpretable predictions of disease progression and treatment response, providing a foundation for patient-specific treatment planning and digital-twin development [202–204]. Camacho-Gomez et al. [205] developed a patient-specific prostate-cancer digital twin using multiparametric MRI and longitudinal prostate-specific antigen (PSA) measurements. T2-weighted MRI defines anatomy and tumor location, diffusion-weighted imaging provides information related to cellularity, and DCE-MRI-derived characterizes vascularization. The mechanistic component models tumor-cell concentration together with PSA production, transport, and decay, while a neural network estimates the spatiotemporally varying proliferating-cell fraction, thereby complementing rather than replacing the mechanistic model.
PIDL can further support adaptive radiotherapy by integrating repeated imaging, deformable registration, biomechanical models, accumulated-dose mapping, and radiation-transport calculations as anatomy and tumor biology evolve during treatment. Such integration enables the estimated dose distribution and treatment plan to be updated according to changes in tumor geometry, organ position, tissue properties, and treatment response. Consequently, physics-informed digital twins provide a potential framework for linking longitudinal imaging, biological evolution, dose accumulation, and personalized treatment adaptation.
Evaluation should therefore extend beyond image-level prediction accuracy to clinically meaningful dosimetric and biological endpoints. For dose prediction, relevant measures include dose MAE, dose-volume-histogram agreement, gamma passing rate, target coverage, conformity and homogeneity indices, and organ-at-risk doses. For digital twins and therapy monitoring, tumor-volume prediction error, longitudinal spatial agreement, biomarker trajectories such as PSA kinetics, and treatment-response accuracy are also important. Key challenges include limited generalization beyond photon therapy, reduced transport accuracy near tissue interfaces, biological and parameter uncertainty, and the scarcity of longitudinal patient data. These limitations motivate uncertainty-aware dose calculation, deliverable treatment optimization, accumulated-dose estimation, and external multicenter validation.
Table 4 summarizes the role of physics-informed learning across major oncologic imaging tasks, highlighting the incorporated physiological information, principal anatomical regions, computational architectures, and representative
Page 22 of 51
Table 4 Representative PIDL Approaches for Major Oncologic Tasks.
| Task | Physics incorporated | ROI / cancer context | Architecture / model | Representative application |
|---|---|---|---|---|
| Detection | Attenuation, diffusion, perfusion, tracer kinetics, tissue acoustics, bioheat transfer, and mechanistic tumor-growth information | Breast, brain, prostate, lung, and other lesion-bearing organs | Physics-informed CNN, hybrid PINN-CNN, inverse PINN, and physics-guided feature-learning models | Lesion localization using physiologically meaningful parameter maps, including thermal, perfusion, diffusion, metabolic, and acoustic biomarkers. In thermal imaging, inverse bioheat models have been used to estimate tumor-associated heat sources and locations [194, 196, 205]. |
| Segmentation | Reaction-diffusion equations, tumor-growth dynamics, biomechanical constraints, conservation laws, anatomical priors, and geometric regularization | Glioma, brain metastases, edema, infiltrative tumor margins, and organs-at-risk | U-Net combined with PINNs, DynUNet, variational networks, level-set models, and hybrid mechanistic-learning frameworks | Biologically informed delineation of tumor core, edema, and infiltrative regions. Physics-informed segmentation frameworks combine image-derived boundaries with mechanistic tumor-growth models to improve biological plausibility and support longitudinal prediction [188]. |
| Classification | Diffusion, perfusion, relaxation, tracer kinetics, vascular response, metabolic activity, and other quantitative imaging biomarkers | Glioma grading, benign-malignant discrimination, and cancer subtype classification | Physics-informed autoencoder, multimodal CNN, hybrid classifier, and physiology-guided feature-learning network | Tumor grading and diagnostic classification using quantitative physiological biomarkers rather than image intensity alone, including DSC-MRI-derived vascular and perfusion characteristics [192, 193]. |
| Quantification | Signal-formation equations, tracer-kinetic and pharmacokinetic models, perfusion and diffusion equations, conservation laws, bioheat transfer, and transport equations | Brain tumors, prostate cancer, breast cancer, and tumor vasculature | PINN, inverse PINN, physics-informed autoencoder, neural operator, and hybrid mechanistic model | Estimation of qMRI, DCE-MRI, DSC-MRI, PET-kinetic, hemodynamic, thermal, and metabolic biomarkers. Governing equations constrain the recovered parameters to remain physiologically meaningful [182, 193]. |
| Reconstruction | MRI forward operators, Fourier and k-space consistency, CT projection and attenuation models, PET system response, point-spread functions, noise statistics, and acoustic wave propagation | Brain MRI, oncologic CT, PET, ultrasound, and multimodal imaging | Unrolled reconstruction network, physics-informed CNN, PINN, PhysicsGAN, transformer, and model-based deep network | Accelerated, sparse-view, low-dose, or undersampled image reconstruction in which predicted images are constrained to remain consistent with the acquired measurements and scanner physics [206]. |
| Motion correction and registration | Elasticity, tissue biomechanics, incompressibility, mass and volume preservation, respiratory dynamics, temporal smoothness, and deformation regularity | Thoracic, abdominal, brain, prostate, and radiotherapy imaging | Registration PINN, biomechanically constrained CNN, implicit neural representation, transformer, and hybrid deformation model | Respiratory, cardiac, and treatment-related motion correction using anatomically plausible deformation fields. Physics-informed constraints reduce folding, unrealistic tissue compression, and non-physical image warping [170, 207]. |
| Treatment planning and dosimetry | Beam geometry, photon attenuation, radiation transport, scattering, dose deposition, bioheat transfer, tumor-growth dynamics, drug interaction, and dosimetric constraints | Prostate, brain, head-and-neck, breast, and other radiotherapy targets | Physics-informed dose-prediction network, differentiable dose model, PINN, finite-element digital twin, and hybrid mechanistic-neural model | Beam-dose prediction, inverse planning, adaptive radiotherapy, hyperthermia optimization, and patient-specific treatment-response modeling. Mechanistic digital twins combine imaging biomarkers with tumor-growth and treatment-response models [202, 203, 205]. |
clinical applications. Further, Table 5 summarizes the major oncologic imaging tasks and corresponding advantages of PIDL, highlighting how physics-based constraints address task-specific challenges and improve the physical consistency and reliability of model predictions.
5. Modality-oriented review of PIDL for oncologic applications
This section provides a modality-specific synthesis that links the governing physical models to their implementation in representative PIDL studies. By distinguishing physics-derived inputs, model-based architectures, and governing-equation constraints, it clarifies how physical Knowledge enters learning across imaging modalities. This synthesis
Page 23 of 51
Table 5 Task-oriented summary of the principal benefits of PIDL in oncological task.
| Oncological application | Why PIDL is effective? |
|---|---|
| Image reconstruction | PIDL integrates image-acquisition and signal-formation physics into the learning process, thereby reducing reconstruction artifacts, improving measurement consistency, and enabling reliable reconstruction from sparse, noisy, or undersampled measurements [162, 208–210]. |
| Image enhancement / denoising | Physics-informed methods incorporate modality-specific noise statistics, image-formation operators, and degradation models, enabling effective noise suppression while preserving anatomical structures, tissue boundaries, and clinically relevant image details [181, 211]. |
| Tumor segmentation | PIDL embeds anatomical, physiological, and tumor-growth constraints into the segmentation process, producing more coherent and physically plausible tumor boundaries, particularly in low-contrast images and limited-annotation settings [188, 212, 213]. |
| Image registration | Physics-informed registration incorporates biomechanical tissue models, elasticity constraints, and deformation regularity, thereby producing anatomically plausible displacement fields while reducing folding and unrealistic image warping [170–172, 177]. |
| Tumor detection / diagnosis | PIDL combines imaging features with disease-specific physiological and biophysical knowledge, which can reduce false-positive detections, improve robustness to imaging variability, and enhance the interpretability of diagnostic predictions [197, 198]. |
| Disease classification | Physics-guided feature learning incorporates quantitative imaging biomarkers, perfusion dynamics, diffusion behaviour, or other physiologically meaningful information, thereby improving feature robustness and potentially enhancing generalization across institutions, scanners, and patient populations [192, 193]. |
| Quantitative parameter estimation | PIDL formulates quantitative imaging as an inverse problem constrained by governing equations, enabling physically consistent estimation of perfusion, diffusion, thermal properties, electrical conductivity, elasticity, and metabolic or hemodynamic parameters [190, 214]. |
| Tumor localization | Physics-informed localization incorporates reaction-diffusion tumor-growth models, multimodal image assimilation, and tissue-biomechanical constraints to infer physiologically meaningful tumor locations, including infiltrative regions that may not be clearly visible in conventional imaging [185, 189, 215]. |
| Treatment planning (hyperthermia/radiotherapy) | PIDL integrates bioheat transfer, radiation-dose deposition, tumor-growth dynamics, and patient-specific tissue properties to improve thermal-field prediction, dose estimation, treatment optimization, and individualized treatment planning [201, 216]. |
| Treatment response prediction | Physics-informed models represent disease progression and treatment-induced physiological changes through mechanistic tumor-growth, drug-transport, and treatment-response equations, leading to more interpretable longitudinal predictions and supporting patient-specific treatment assessment [6, 201, 217]. |
complements the task-oriented review and supports comparison of the assumptions and roles of physics in oncologic applications. Tables 6 and 9 summarize representative connections.
5.1. CT imaging
CT image formation is governed by energy-dependent X-ray attenuation. Under the monochromatic, scatter-free approximation, the Beer-Lambert law relates the transmitted intensity along a ray path to the attenuation
Page 24 of 51 distribution :
here, s denotes distance along the ray, is the incident intensity, and R is the ray-integral projection operator. Polychromatic models additionally account for the source spectrum and detector response [218]. In DECT, energy-dependent attenuation supports the material decomposition. Poirot et al. [219] combined a physics-based material-decomposition mapping with a CNN correction to estimate non-contrast images. Physics, therefore, enters through the network input rather than an explicit physical residual. Moreover, authors in Hellwege et al. [218] explicitly embedded a polychromatic forward model in unsupervised DECT material decomposition:
where is the normalized spectrum including detector response, is the attenuation coefficient of basis material , is the projection matrix, and is its predicted spatial coefficient map. Training minimizes the projection-domain discrepancy, expressed for one acquisition as
where M is the number of rays per spectrum and denotes the measured log-transformed projection. The differentiable forward model supplies the training constraint, enabling material decomposition without ground-truth material images. CT harmonization incorporates a complementary form of scanner physics through the modulation transfer function (MTF). Under linear, shift-invariant and isotropic imaging assumptions, images reconstructed using different kernels can be related approximately by
here, F denotes the Fourier transform and the ratio requires care where the denominator is small. Zarei et al. [56] incorporated measured MTF information into a GAN generator to learn CT harmonization. This approach incorporates scanner physics through network conditioning, complementing the projection-domain constraints used for DECT.
5.2. MRI
MRI-based PIDL incorporates acquisition and physiological physics through three complementary mechanisms: data-consistency constraints or unrolled reconstruction, differentiable signal and tracer-kinetic models, and physiological PDE residuals, as in Eq. (6), in the learning objective.
Acquisition physics as data consistency : For a multi-coil acquisition, the measured k-space data are related to the image by
where is the coil-sensitivity map, is the Fourier transform, and is the sampling operator [220]. Stacking the coil-specific operators gives \mathbf{A}\mathbf{x} = (\mathbf{P}\mathcal{F}\mathbf{S}_c\mathbf{x})_{c=1}^N_c. PIDL incorporates this forward model through a data-consistency loss or explicit reconstruction layers:
where is the network output and is a learned denoiser. Specific studies differ mainly in how they extend A and where they impose the constraint:
• Motion correction: PI-MoCoNet [221] applies to a U-Net/Swin-Transformer [111] output, so that motion artifacts are removed without departing from the acquired data.
Page 25 of 51
• Unrolled and diffusion-prior reconstruction: Fujita et al. [210] unroll the iteration in Eq. (39) for accelerated clinical 3D-FLAIR. Ahmed et al. [222] replace with a score-based diffusion prior and enforce at each sampling step.
- Main-field inhomogeneity: Schote et al. [209] augment A with an off-resonance phase , parameterize in a spherical-harmonic basis, and estimate it jointly with for low-field MRI.
• Learned sampling: PILOT [223] and Peng et al. [208] learn P itself. The trajectory is optimized jointly with the reconstruction, subject to gradient-amplitude and slew-rate limits and . PILOT imposes these limits as penalties, whereas Peng et al. [208] parameterize by a neural ODE.
Signal and tracer-kinetic models as differentiable decoders : In quantitative MRI, a network predicts tissue parameters from measured signals . A known signal model then maps these parameters back to the signals expected under the acquisition settings , which permits self-supervised training without ground-truth parameter maps:
The choice of g defines the application.
Relaxometry: For relaxometry, g is a closed-form steady-state solution of the Bloch equations. For spin echo,
where PD is the proton density and and are the repetition and echo times. Jacobs et al. [224] use such models to synthesize arbitrary contrasts from predicted maps. PINQI [162] couples an inversion-recovery model with Eq. (38), so that is estimated directly from undersampled k-space.
DCE-MRI: For DCE-MRI, g is the extended Tofts model [225],
where and are the tissue and plasma contrast-agent concentrations, is the volume transfer constant, and and are the plasma and extravascular extracellular volume fractions. Sainz et al. [182] showed that this constraint improves the robustness of estimation under noise.
DSC-MRI: For DSC-MRI, g is the indicator-dilution convolution [226],
where is the arterial input function, is the residue function, and CBF is the cerebral blood flow. Rotkopf et al. [192] and SPINNED [227] represent and with networks constrained by Eq. (43), which regularizes this ill-posed deconvolution. Van Herten et al. [191] apply the same principle to myocardial perfusion, using the residual of a two-compartment exchange model.
Physiological PDEs as residual constraints : When the quantity of interest is a spatiotemporal field that MRI observes only sparsely or indirectly, the governing PDE enters the loss as in Eq. (6). The residuals used in the MRI literature are
Page 26 of 51
Each residual serves a different inverse problem.
Flow: Eq. (44a) super-resolves and denoises 4D-flow velocities u and recovers the unmeasured pressure p. This approach was used with fully connected PINNs [181], on graph edges for irregular vascular domains [211], and for refining high-velocity regions [228]. Sarabian et al. [190] use a reduced-order one-dimensional counterpart of this model together with sparse Doppler and MRI data.
Electrical-property tomography: Eq. (44b) is the Helmholtz form of Maxwell's equations for the measured transmit field . Treating the conductivity and permittivity as trainable fields avoids the noise-amplifying second derivatives of conventional EPT [214, 229, 230].
Molecular transport: Eq. (44c) identifies the effective diffusivity D of an MRI tracer from sparse time points [231].
Tumor growth: Eq. (44d) is the Fisher-Kolmogorov model [135], and it is the most directly oncologic of the four residuals. MRI supplies the domain, the tissue-dependent diffusivity , and threshold observations of the tumor-cell density u. The PINN then infers the patient-specific parameters and the infiltration beyond the visible margin. El et al. [187] couple this model with U-Net segmentation and uncertainty quantification. Zhang et al. [189] pre-train on the PDE and fine-tune to individual glioblastoma patients. Table 6 lists each study together with its embedding strategy and governing equation.
5.3. PET
PET-based PIDL incorporates photon-counting statistics, attenuation and resolution effects into reconstruction, and tracer kinetics into parametric imaging. Radioactive decay, with , requires consistent temporal referencing of measured activity and input functions. The principal integration mechanisms are likelihood-based reconstruction, tissue-informed correction, and kinetic-model constraints.
Measurement physics and learned reconstruction: For an activity image , uncorrected coincidence counts are modeled as conditionally independent Poisson variables, [232], with
Here, G projects activity onto lines of response, H approximates resolution effects, and n contains multiplicative detector-sensitivity factors. The attenuation coefficient is evaluated at 511 keV; r and s represent expected random and scattered coincidences. The corresponding negative log-likelihood, up to constants, is
This objective connects learned image representations directly to the measured counts. Gong et al. [233] embedded a pretrained CNN representation in constrained likelihood-based reconstruction, using ADMM to alternate between image and network-input updates. FBSEM-Net [234] instead unrolled forward–backward splitting EM, combining a learned regularization step with an EM data-fidelity step and weighted fusion. Thus, acquisition physics enters the reconstruction architecture rather than being applied only after image formation.
Tissue-informed positron-range correction: Positron transport before annihilation introduces radionuclide- and tissue-dependent blurring [235]. A general image-space approximation is
where describes the tissue distribution and is a spatially varying positron-range kernel. Encina-Baranda et al. [236] incorporated attenuation-map information into 3D residual encoder–decoder networks and a tissue-dependent
Page 27 of 51
Table 6
Representative PIDL methods for MRI. Strategy: DC = acquisition-physics data consistency; MD = differentiable signal/kinetic model decoder; PR = PDE-residual constraint.
| Reference | Strategy | Embedded physics (Eq.) | Objective | Principal contribution |
|---|---|---|---|---|
| [223] | DC | Trajectory with gradient/slew limits | Acquisition design | Joint learning of hardware-feasible trajectory and reconstruction. |
| [208] | DC | Neural-ODE trajectory | k-space optimization | Continuous trajectories learned with reconstruction. |
| [209] | DC | Off-resonance forward model, Eq. (38) | Low-field reconstruction | Joint -field and image estimation. |
| [210] | DC | Unrolled forward model, Eq. (39) | 3D-FLAIR reconstruction | Accelerated reconstruction with clinical validation. |
| [222] | DC | k-space consistency with diffusion prior, Eq. (39) | Reconstruction (fastMRI) | Diffusion-model reconstruction with measurement consistency. |
| [221] | DC | k-space consistency loss, Eq. (39) | Motion correction | Artifact suppression consistent with acquired data. |
| [224] | MD | Bloch signal models, Eq. (41) | Contrast synthesis | Arbitrary contrasts from . |
| [162] | DC+MD | Forward model and IR model | Quantitative mapping | End-to-end quantitative reconstruction. |
| [182] | MD | Tofts model, Eq. (42) | DCE-MRI parameters | Noise-robust , , estimation. |
| [192] | MD | Indicator dilution, Eq. (43) | DSC perfusion | Physics-informed CBF/CBV/MTT estimation. |
| [227] | MD | Indicator dilution, Eq. (43) | DSC deconvolution | Training-free, constrained deconvolution. |
| [191] | PR | Two-compartment exchange | Myocardial perfusion | Physiologically constrained perfusion parameters. |
| [181] | PR | Navier-Stokes, Eq. (44a) | 4D-flow super-resolution | High-resolution velocity and pressure. |
| [211] | PR | Navier-Stokes on graph, Eq. (44a) | 4D-flow super-resolution | Graph learning on irregular vascular domains. |
| [228] | PR | Navier-Stokes, Eq. (44a) | Flow refinement | Improved high-velocity regions. |
| [190] | PR | Reduced-order hemodynamics | Cerebral flow | High-resolution flow from sparse TCD/MRI. |
| [214] | PR | Helmholtz, Eq. (44b) | EPT | Noise-robust conductivity reconstruction. |
| [230] | PR | Helmholtz, Eq. (44b) | EPT | Stable electrical-property reconstruction. |
| [231] | PR | Diffusion, Eq. (44c) | Molecular transport | Inverse estimation of diffusivity. |
| [187] | PR | Fisher-Kolmogorov, Eq. (44d) | Tumor delineation and growth | Segmentation, growth prediction, and UQ. |
| [189] | PR | Fisher-Kolmogorov, Eq. (44d) | Glioblastoma infiltration | Patient-specific pre-trained/fine-tuned PINN. |
loss for preclinical Ga PET correction. Here, physics informs the training data, anatomical inputs, and loss weighting, rather than entering as an explicit transport-equation residual.
Tracer-kinetic constraints: Dynamic PET links tissue time–activity curves to the plasma input function . The two-tissue compartment model underlying FDG kinetic analysis describes transport and phosphorylation through [237]
where and denote unphosphorylated and phosphorylated tracer concentrations, is the influx coefficient, and , , and are rate constants. For consistently decay-corrected concentrations, the measured tissue signal is modeled as
where is the blood-volume fraction and is whole-blood activity concentration.
Page 28 of 51
Table 7 Physics incorporation in representative PET learning and related inverse methods.
| Reference | Physical model | Integration mechanism | Application |
|---|---|---|---|
| [233] | PET forward model and Poisson likelihood, Eqs. (45) and (46) | Pretrained CNN representation within constrained likelihood optimization | PET reconstruction |
| [234] | PET forward model and Poisson likelihood | Unrolled EM data-fidelity steps with learned regularization | PET and MR-guided PET reconstruction |
| [236] | Tissue-dependent positron-range blurring, Eq. (47) | Simulation-based training, attenuation-map inputs, and tissue-dependent loss | Preclinical Ga resolution correction |
| [215] | Reaction-diffusion growth, Eq. (50) | Joint imaging and physics constraints | MRI/FET-PET glioma inference |
| [216] | Discretized growth model, Eq. (51) | Direct field optimization with soft physics and data penalties | Individualized glioma infiltration maps for radiotherapy planning |
These kinetics can enter PIDL as differential-equation residuals or as a differentiable decoder mapping predicted parameters to time–activity curves. Predicted signals should be averaged over acquisition frames before comparison with reconstructed dynamic images, for example using weighted least squares. For direct estimation from count data, the kinetic predictions must instead pass through the PET forward model before evaluating Eq. (46). This links parameter estimation to tracer physiology [238].
Tumor-growth constraints and multimodal assimilation: Beyond acquisition and tracer kinetics, PET can constrain mechanistic tumor models. A Fisher–Kolmogorov model [135] describes normalized tumor-cell density u as
where D represents tissue-dependent infiltration and is the proliferation rate. MRI-derived tumor regions and FET-PET uptake provides complementary observation constraints. Their relationship to cell density is a modeling assumption, rather than a direct measurement of tumor-cell concentration. Moreover, Balcerak et al. [215] combined multimodal observations with reaction–diffusion constraints to infer patient-specific glioma distributions. Glioma Optimizing the Discrete Loss (GliODIL) [216] optimizes discretized fields and parameters using a composite objective, written schematically as
where is the discretized growth-model residual. The soft physics penalty allows a trade-off between model agreement and imaging observations. GliODIL is a related physics-informed inverse method rather than a neural-network representation of the solution; it is included to distinguish direct field optimization from PIDL. Table 7 summarizes these mechanisms.
5.4. Ultrasound
Ultrasound-based PIDL incorporates acoustic propagation into sound-speed reconstruction and fluid mechanics into vascular flow estimation. Physics enters through simulated training data and reconstructed inputs, differentiable inversion steps, or governing-equation residuals.
Acoustic physics and sound-speed estimation: Under the linear, constant-density, lossless approximation, acoustic pressure satisfies
where is sound speed and s is the source. More complete models account for density variations and frequency-dependent attenuation, often represented by [239]. Numerical solvers such as k-Wave provide acoustic simulations for training and forward modeling [240]. Spatial variations in sound speed produce an anomaly when beamforming assumes a homogeneous medium, motivating patient-specific sound-speed estimation.
Page 29 of 51
Jeong et al. [148] trained a CNN to combine a low-resolution sound-speed map from traveltime tomography with a reflectivity map from reflection tomography. The former provides quantitative propagation information, while the latter supplies tissue-boundary information. Training used numerical breast phantoms, with additional evaluation on clinical breast data. Physics therefore enters through simulation and the complementary reconstructed inputs, rather than an explicit PDE residual in the loss.
Physics-guided full-waveform inversion: Full-waveform inversion (FWI) estimates sound speed by matching simulated and measured receiver signals [241, 242]:
Here, is the wavefield for source , is the signal measured at receiver , and is a regularizer. Wave-equation gradients, commonly evaluated using adjoint methods [243], connect signal mismatch to updates of . Repeated wave solves and sensitivity to initialization motivate learned inversion. Zhang et al. [149] unfolded FWI into a sequence of learned updates driven by the data-fidelity gradient. Schematically,
where predicts an update from the physics-derived gradient. The method reported real-time sound-speed reconstruction in simulations and phantom experiments for edema assessment. It illustrates a transferable inversion strategy, while oncologic performance requires separate validation. The forward model guides each update, but does not guarantee exact data consistency.
Microvascular flow and pressure inference: Ultrasound localization microscopy estimates microvascular velocities by tracking individual microbubbles [244]. Sparse velocity observations can be supplemented by incompressible-flow constraints. Under a Newtonian approximation with negligible body forces,
where , , v, and denote blood density, dynamic viscosity, velocity, and pressure. Liang et al. [245] combined super-resolution ultrasound observations with hemodynamic simulations through data assimilation, then fitted a PINN constrained by two-dimensional Navier–Stokes equations. Its principal loss components can be summarized as
where fits the assimilated velocity data, is the momentum residual, and the brackets denote averaging over collocation points. The study included liver-tumor peritumoral vessels, providing an oncologic application of flow-constrained learning. Pressure is inferred indirectly through momentum balance and requires a reference to fix its spatially uniform component. Interpretation depends on the assumed rheology, boundary conditions, and adequacy of the two-dimensional flow approximation. Table 8 summarizes these distinct routes for incorporating physics.
5.5. Thermal imaging
Infrared thermography estimates skin-surface temperature from measured radiance. Thermal PIDL links these observations to subsurface heat transport, allowing tissue temperature and selected thermal or tumor parameters to be inferred under a bioheat model.
Bioheat transport and surface observations: The Pennes equation describes heat conduction, perfusion, and metabolic heat generation [195]:
Here, , c, and k are tissue density, specific heat capacity, and thermal conductivity; and are the corresponding blood properties; is volumetric perfusion per unit tissue volume; and is arterial temperature. The terms and
Page 30 of 51
Table 8
Physics incorporation in representative ultrasound learning methods.
| Reference | Physical information | Integration mechanism | Application |
|---|---|---|---|
| [148] | Acoustic propagation and reflection | Simulation-based training with travel-time and reflection tomography inputs | Breast sound-speed reconstruction |
| [149] | Waveform data fidelity, Eq. (53) | Learned updates driven by wave-model gradients, Eq. (54) | Sound-speed reconstruction for edema assessment; simulation and phantom validation |
| [245] | Incompressible Navier-Stokes equations, Eq. (55) | Data assimilation and PINN residual penalties, Eq. (56) | Microvascular velocity and pressure inference, including liver-tumor peritumoral vessels |
denote basal and additional tumor-associated volumetric heat generation. Tumor effects can be represented through spatial variations in heat generation and perfusion, rather than assuming that every lesion produces the same thermal response. For equilibrated static acquisitions, the model is commonly approximated as steady state.
A prescribed chest-wall temperature, , can be combined with convective and radiative heat exchange at the skin:
where is the outward normal, is the convective coefficient, is air temperature, and is effective radiative-surroundings temperature. The radiative term uses absolute temperatures, skin emissivity , and the Stefan–Boltzmann constant . Camera-derived surface temperatures require calibration accounting for emissivity and reflected environmental radiation.
Forward and inverse physics-informed learning: A PINN represents temperature by and penalizes the residual of Eq. (57) together with the boundary conditions. With prescribed tissue and tumor parameters, this gives a forward temperature solver, as investigated by Mukhmetov et al. [197] and Zhao et al. [198]. Perez-Raya et al. [194] applied this framework to patient-specific breast geometries and thermal-conductivity estimation. For steady-state inverse modeling, selected unknown parameters are optimized jointly with the network using surface observations:
Here, is the steady-state bioheat residual, the brackets denote averaging over interior collocation points, and enforces the thermal boundary conditions. Depending on the available data and prior assumptions, may include conductivity, perfusion, heat-source strength, or tumor geometry. Perez-Raya et al. [196] investigated inverse estimation of tumor characteristics from surface temperature data using this physics-informed approach. Transient formulations additionally require initial conditions and time-resolved observations. Residual-based adaptive refinement concentrates training points where the governing-equation residual is large [246, 247]. Das et al. [199] used distribution-based adaptive refinement for breast thermal simulations and inverse thermal-coefficient identification. This improves numerical resolution of the bioheat model; it does not remove the non-uniqueness of the inverse problem. Heat diffusion smooths subsurface signatures, and different combinations of tumor depth, size, perfusion, and heat generation can produce similar surface temperatures. Consequently, inferred parameters remain conditional on the assumed geometry, boundary conditions, and prior constraints.
5.6. Hybrid imaging and multiphysics models
Hybrid PIDL couples complementary imaging information through acquisition models, anatomical constraints, or mechanistic models of disease. The coupling mechanism determines whether physics guides reconstruction, parameter estimation, or longitudinal inference.
Anatomy-guided reconstruction: In PET/MRI, MR images support attenuation-map estimation and provide anatomical information for PET reconstruction. MRI does not directly measure attenuation at 511 keV; the attenuation map
Page 31 of 51 must be inferred using an additional mapping or tissue model. A schematic learned reconstruction objective is
where is the estimated attenuation map, is the anatomical image, and represents an MR-conditioned learned regularizer. The PET forward model and likelihood remain those of Eqs. (45) and (46). Rajagopal et al. [147] reviewed these physics-driven reconstruction strategies, while FBSEM-Net [234] provides an example of incorporating MR information into learned regularization within unrolled PET reconstruction. Anatomical guidance must accommodate PET uptake patterns without corresponding MR boundaries. Furthermore, multimodal MRI can constrain the reaction–diffusion model of Eq. (50) without introducing another growth equation. Structural images define the brain geometry and tissue distribution, while T1-weighted contrast-enhanced and FLAIR segmentations constrain cell-density patterns through assumed observation thresholds. Zhang et al. [189] combined these constraints with a PINN, using characteristic dimensionless parameters for pre-training and subsequent patient-specific fine-tuning. Their formulation supports inference from a single-time MRI snapshot under the adopted scaling and observation assumptions. Here, imaging constrains the visible tumor, while the PDE regularizes the inferred infiltration beyond its segmented boundary.
Imaging-informed biomarker dynamics: Camacho-Gomez et al. [205] coupled multiparametric MRI, tumor growth, and prostate-specific antigen (PSA) dynamics in a prostate digital twin. T2-weighted MRI provides geometry, diffusion-derived ADC maps inform cellularity, and DCE-derived informs vascular exchange under model-specific assumptions. The learned component regulates tumor-cell growth:
where is tumor-cell concentration, is a growth-rate parameter, and is the network-estimated proliferating fraction. Mechanistic equations describe tissue PSA production, tissue–blood exchange, and serum clearance, linking spatial tumor dynamics to measured serum PSA. The network is trained to reproduce PSA dynamics, while patient-specific model calibration also uses follow-up MRI. Subsequent PSA observations guide tumor-growth reconstruction within the calibrated model. Thus, learning supplies a component of the mechanistic simulation rather than replacing its governing equations. The inferred spatial growth remains conditional on the imaging-to-parameter mappings and biomarker model.
5.7. Additional modalities and emerging PIDL applications
Additional imaging modalities provide opportunities to incorporate acquisition physics into learning. The examples below distinguish demonstrated integration mechanisms from potential extensions to oncologic applications.
Mammography and digital breast tomosynthesis: Mammography and digital breast tomosynthesis (DBT) share the X-ray attenuation physics discussed in Section 5.1. In DBT, limited angular coverage makes reconstruction underdetermined. Moriakov et al. [248] incorporated the acquisition operator into a learned primal–dual reconstruction scheme, combining projection and backprojection with trainable updates. Teuwen et al. [249] extended this approach with breast-thickness information for volumetric density and patient-specific imaging-dose estimation. Physics therefore enters through the reconstruction operator and acquisition-specific priors, rather than requiring another attenuation equation.
SPECT: SPECT reconstruction combines Poisson counting statistics with emission-point-dependent attenuation and collimator–detector response:
Here, is voxel activity, represents geometric sensitivity and detector response, and is expected scatter. The attenuation factor is written in a ray-path approximation and depends on the emitting voxel. Yu et al. [250] combined physics-based attenuation estimation from scatter-window data with CNN segmentation, then used the resulting attenuation map in iterative activity reconstruction. Chen et al. [251] compared direct learned attenuation correction with indirect approaches that estimate attenuation maps for reconstruction. These cardiac SPECT studies illustrate
Page 32 of 51 transferable correction strategies; they do not establish oncologic performance. The distinction is whether the physical model is explicitly used in reconstruction or its correction is learned from paired examples.
Cone-beam CT (CBCT) and radiotherapy imaging: CBCT shares CT transmission physics but requires particular attention to scatter, acquisition geometry, and changing patient anatomy. These effects motivate physics-guided scatter correction, reconstruction, and anatomical registration. Their relevance to adaptive radiotherapy lies in preserving image geometry and calibrated tissue densities for dose calculation. Clinical CBCT-guided adaptive workflows [252] establish the application context, but AI-assisted adaptation alone does not demonstrate physics-informed learning.
Photoacoustic imaging: Photoacoustic imaging couples optical absorption to acoustic propagation. Under thermal and stress confinement, a short optical pulse produces initial pressure [253]
where is the Grüneisen parameter, is the optical absorption coefficient, and is fluence, which depends on tissue absorption and scattering. The pressure propagates according to Eq. (52), with and . Paul et al. [254] combined model-derived data-fidelity gradients with learned regularization for sparse linear-array reconstruction. This constrains the acoustic inverse problem. Quantitative absorption and oxygenation estimation additionally require accounting for spatially and spectrally varying fluence [255]; accurate pressure reconstruction alone does not resolve that optical inverse problem.
Optical diffraction tomography: Under a scalar-wave approximation, optical scattering is governed by
where u is the optical field, is the free-space wavenumber, and n is refractive index. Saba et al. [256] trained a PINN using the Helmholtz residual as a physical loss to approximate the scattering forward model for tomography. This connects learned field prediction to wave physics and supports refractive-index reconstruction, while oncologic diagnostic applications require separate evaluation.
Histopathology: For bright-field stained sections, an approximate Beer–Lambert model relates optical density to stain contributions:
where denotes the stain absorption spectrum and an effective stain amount along the optical path. This approximation underlies stain separation and normalization [257]. It can provide a physical prior for learned color processing, but conventional stain normalization alone is not PIDL.
Table 9 summarizes selected task–modality links supported by the studies discussed.
6. Datasets and data sources
The reviewed PIDL literature employs heterogeneous data sources spanning public oncologic imaging datasets, clinical cohorts, synthetic simulations, physical phantoms, and experimental measurements. Representative datasets included in the reviewed studies are summarized in Table 10.
7. Challenges and clinical translation of PIDL in oncologic imaging
Despite the growing success of PIDL in oncologic imaging, several fundamental challenges continue to constrain its widespread adoption and clinical deployment. In image reconstruction, a principal open problem is the extension of current methods to fully three-dimensional and spatiotemporal imaging, such as 4D MRI, while faithfully representing complex acquisition physics, non-Cartesian sampling and nonlinear effects. Equally pressing is the need for robust performance under distribution shifts arising from differences in scanner hardware, acquisition protocols and patient populations, together with the reliable integration of uncertainty estimation. Recent work has accordingly turned towards self-supervised learning, which reduces reliance on ground-truth images, and towards approaches that remain
Page 33 of 51
Table 9
Selected task-modality links and mechanisms of physics incorporation. Entries are illustrative, not an exhaustive coverage map; inclusion does not imply clinical validation in oncology.
| Task | Modality | Physics incorporation | Examples |
|---|---|---|---|
| Reconstruction | CT and DBT | Polychromatic forward-model losses or acquisition operators within learned iterations | [218, 248] |
| Emission reconstruction | PET, PET/MRI, and SPECT | Poisson likelihood, system response, and physics-based attenuation correction | [233, 234, 250] |
| Sound-speed and acoustic-source reconstruction | Ultrasound and photoacoustics | Wave-model gradients combined with learned updates or regularization | [149, 254] |
| Resolution correction | PET | Tissue-dependent positron-range modeling, simulation, and loss weighting | [236] |
| Physiological parameter inference | Ultrasound and thermal imaging | Navier-Stokes or bioheat residuals combined with observations | [194, 245] |
| Tumor infiltration inference | MRI and MRI/FET-PET | Reaction-diffusion constraints with imaging observation models; PINNs or direct field optimization | [189, 216] |
| Tumor and biomarker dynamics | Multiparametric MRI with serum PSA | Learned proliferation within a mechanistic growth and biomarker model | [205] |
| Breast-density and imaging-dose estimation | DBT | Unrolled reconstruction with acquisition geometry and breast-thickness information | [249] |
effective when the assumed physical model is incomplete, uncertain or misspecified. The principal obstacles are discussed below.
Data availability and physics-model fidelity: Although the incorporation of prior physical knowledge lessens dependence on large annotated datasets, model development nonetheless requires sufficiently diverse imaging data for training, calibration and independent validation [15, 16]. In oncology, access to such data is frequently limited by acquisition and annotation costs, patient-privacy requirements, institutional data silos, inter-observer variability and the low prevalence of certain cancer types [116, 118, 119]. These limitations are especially consequential when performance must be assessed across institutions, scanner vendors, acquisition protocols and patient populations.
The reliability of PIDL is further contingent on the fidelity of the embedded physical model. Existing frameworks commonly adopt simplified assumptions regarding tissue properties, physiological processes, boundary and initial conditions, imaging-system response or tumor-growth dynamics [16, 18]. Such assumptions may not adequately capture tumor heterogeneity, patient-specific anatomy, evolving treatment response or uncertainty in physiological parameters. Discrepancies between the imposed physics and clinical reality can therefore introduce systematic bias, constrain the learned solution towards an incorrect physical regime and diminish predictive reliability under domain shift [15, 120]. Future PIDL frameworks should incorporate uncertainty-aware model calibration, adaptive weighting of physical and data-driven losses, and mechanisms for detecting or correcting physical-model misspecification.
Generalization and robustness: Achieving robust performance across heterogeneous imaging protocols, scanner vendors, institutions and patient populations remains a central challenge. Physics-based constraints can improve generalization by restricting the learned solution to physically plausible regimes, yet they do not eliminate domain shift or model misspecification [15, 18]. Differences in acquisition parameters, reconstruction pipelines, hardware characteristics, patient anatomy and disease phenotype can substantially alter image distributions and degrade performance when models are applied outside the conditions represented during development [120]. This vulnerability is most pronounced when the embedded physical assumptions, parameter values or boundary conditions are inaccurate for a new clinical setting. Robust clinical deployment will therefore require external validation across independent institutions, scanner platforms, acquisition protocols and diverse patient cohorts, complemented by sensitivity analyses and strategies for adapting the model when either the data distribution or the assumed physics changes.
Uncertainty quantification and interpretability: Reliable uncertainty quantification is essential for clinical deployment, as PIDL predictions are affected by measurement noise, uncertain parameters, incomplete physics and model mismatch [70]. Bayesian physics-informed neural networks (PINNs) and ensemble-based methods offer promising
Page 34 of 51
Table 10
Representative datasets and data sources used in physics-informed oncologic imaging studies.
| Dataset / source | Data | Data type | Primary use in reviewed studies | References |
|---|---|---|---|---|
| BraTS | Multimodal brain MRI (T1, T1c, T2, FLAIR) with expert annotations | Glioma segmentation, tumor delineation, and tumor-growth modeling | [258] | |
| BraTS-METS 2023 | Brain MRI with metastatic lesion annotations | Physics-informed brain metastasis segmentation and tumor-boundary delineation | [259] | |
| Stanford BrainMetShare | Independent brain metastasis MRI cohort | External validation of physics-informed segmentation models | [260] | |
| TCIA collections | MRI, CT, and PET/CT cancer imaging | Tumor segmentation, reconstruction, quantitative analysis, and model development; includes TCGA-GBM, TCGA-LGG, NSCLC Radiogenomics, AAPM-Mayo Low-Dose CT, and Mayo PET/CT Kidney | [152] | |
| LIDC-IDRI | Annotated lung CT | Pulmonary nodule detection, reconstruction, and quantitative analysis | [261] | |
| KiTS | Abdominal CT with kidney and kidney-tumor annotations | Renal tumor segmentation | [262] | |
| PROMISE12 | Prostate MRI with gland annotations | Prostate segmentation | [263] | |
| QIN-BREAST-02 | Multiparametric breast MRI, including CE-MRI, DWI, and ADC maps | Patient-specific tumor characterization and mechanistic tumor modeling | [264] | |
| ACRIN 6698 / I-SPY2 | Longitudinal multiparametric breast MRI with treatment-response information | Neoadjuvant chemotherapy response modeling | [265, 266] | |
| fastMRI | MRI acquisition data | Physics-consistent accelerated image reconstruction | [150] | |
| Clinical and private cohorts | Institution-specific MRI, CT, PET, and radiotherapy data | Tumor modeling, reconstruction, segmentation, dose prediction, and clinical validation | [267–269] | |
| Synthetic, simulated, phantom, and in-vitro data | Data generated from governing equations, imaging forward models, physical phantoms, or experimental systems | PINN training, inverse modeling, reconstruction, and validation | [270–272] |
solutions, but their use in oncologic imaging remains limited [73]. Interpretability presents a related concern: although physical constraints enhance transparency, PIDL models can still exhibit black-box behavior, limiting clinician trust [273].
Computational scalability: The incorporation of physical constraints inevitably increases computational cost, because PINNs require repeated evaluation of PDE residuals and higher-order derivatives during training [16, 43]. This burden becomes particularly significant for high-resolution three-dimensional imaging, multiphysics models and large clinical datasets. Recent advances, including neural operators, adaptive sampling and hybrid physics-data-driven architectures, have improved training efficiency and scalability; nevertheless, computational cost remains a major impediment to routine clinical deployment [86].
Benchmarking and clinical translation: The absence of standardized benchmarks and evaluation protocols remains a major barrier to the objective assessment of PIDL methods. Most studies rely on small, single-center or institution-specific datasets, which limits reproducibility and precludes direct comparison across approaches. Progress will
Page 35 of 51
Key challenges of PIDL in oncologic image analysis

Figure 8: Key challenges limiting the development and clinical translation of PIDL in oncologic image analysis.
require publicly available benchmark datasets, consistent reporting of accuracy, physical consistency, uncertainty and computational cost, and multi-center, prospective clinical validation. Regulatory translation will further demand clear evidence of safety, robustness, interpretability and clinical benefit. Successful integration into routine oncology workflows will thus depend on sustained collaboration among clinicians, medical physicists, imaging scientists, regulatory experts and AI researchers.
In summary, the potential of PIDL in oncologic imaging is tempered by interrelated challenges spanning data availability, generalizability, uncertainty quantification, interpretability, computational cost, validation and clinical integration, as summarized in Fig. 8.
8. Discussion
Physics-informed deep learning (PIDL) reconciles the representational capacity of deep neural networks with the rigor of physical and physiological modeling. By embedding governing equations, imaging-system physics, biomechanical constraints and domain knowledge directly within the learning process, PIDL confers physical consistency, partial interpretability, robustness and data efficiency that purely data-driven approaches cannot guarantee. This review has examined the theoretical foundations of the field, encompassing physics-informed neural networks (PINNs), physics-informed convolutional neural networks (PICNNs), physics-informed Kolmogorov-Arnold Networks (PIKANs), physics-informed operator-learning (PINO) frameworks, physics-informed generative models (PIGMs) together with their application across the principal oncologic imaging tasks and modalities, namely CT, MRI, PET, ultrasound, thermal imaging, hybrid imaging and emerging modalities. Here, we synthesize this evidence into task-specific design principles, delineate the research directions most likely to define the next generation of PIDL, and identify the conditions required for its clinical translation.
Towards a task-dependent design principle: A systematic synthesis of existing studies demonstrates that no single physics-informed architecture is optimal across all oncologic imaging tasks. The appropriate strategy is determined by the nature of the inverse problem, the available measurements, the governing physical model, the dimensionality of the data and the clinical objective. A unifying principle emerges from the reviewed literature: physics should be introduced
Page 36 of 51 at the stage most directly related to the underlying imaging or biological process. Acquisition physics is most naturally enforced during reconstruction and quantitative imaging; anatomical and biomechanical constraints are better suited to segmentation and motion correction; biological and transport models are better suited to tumor progression and treatment-response modeling; and radiation-transport models should be explicitly coupled to dosimetry and treatment planning. We therefore contend that physics should not be treated as a universal penalty term. Instead, task-specific physics-data coupling is required, in which the physical model, network architecture, loss formulation and validation strategy are selected jointly according to the clinical objective. The workflows below operationalize this principle for the major computational oncology tasks.
Image reconstruction: The optimal workflow couples the measured acquisition data directly to a differentiable imaging forward model, rather than relying solely on image-domain supervision. The proposed pipeline comprises: (i) preprocessing and normalization of raw measurements; (ii) initialization with a conventional reconstruction or a learned prior; (iii) extraction of image-domain features with a convolutional neural network (CNN), U-Net or transformer; (iv) explicit enforcement of acquisition-domain consistency through the forward model; and (v) joint optimization of data-fidelity, image-regularization and physics-consistency losses. For MRI, k-space consistency and Fourier encoding should be incorporated explicitly, whereas CT reconstruction should account for the X-ray projection and attenuation model. For high-dimensional volumetric reconstruction, operator-learning architectures are preferable to conventional coordinate-based physics-informed architectures on grounds of computational scalability.
Tumor segmentation and boundary delineation: The reviewed literature indicates that governing physical systems complement image-derived anatomical features. We therefore propose a hybrid workflow in which a U-Net, UNet++, Swin-based encoder-decoder or related architecture first extracts multiscale tumor features, after which tumor-growth, diffusion, edema-transport, biomechanical or modality-specific physical constraints are imposed. The optimization objective should balance segmentation accuracy against physical consistency, for example, by combining cross-entropy losses with physics-based residual or boundary losses. For anatomically complex tumors, boundary-aware physical constraints should take precedence over global PDE constraints. External validation across institutions is indispensable to establish whether the physical prior enhances segmentation robustness, rather than merely improving performance within the training domain.
Tumor detection and classification: In detection and classification, physics should constrain the representation, feature extraction and decision function without supplanting the discriminative learning objective. The workflow begins with a physically consistent representation of the available patient-specific information, which may comprise multimodal images, quantitative imaging biomarkers, physiological measurements, molecular profiles, clinical variables or model-derived parameters. Depending on the modality and task, physical information can be introduced through acquisition-aware preprocessing, physics-based feature construction, mechanistic parameters or explicit regularization terms that penalize predictions inconsistent with known anatomical, physiological, metabolic or imaging relationships. The resulting representations can be processed by CNNs, transformers, multilayer architectures or multimodal fusion networks, with the classification objective optimized jointly with a physics-consistency loss that constrains the learned representation or prediction according to the relevant physical model. The choice of constraint should be modality- and disease-specific: PET-based models can incorporate tracer kinetics, attenuation and activity-distribution constraints, whereas MRI-based models can exploit acquisition physics, relaxation characteristics and tissue-dependent signal relationships. For multimodal data, complementary physical and biological information should be fused at the feature or latent-representation level while preserving modality-specific constraints.
Quantitative imaging and parameter estimation: Quantitative imaging is a particularly appropriate setting for physics-informed learning, because the desired outputs are frequently physical or physiological parameters rather than categorical labels. The problem should accordingly be formulated as a physics-constrained inverse problem: imaging measurements are related to the relevant forward model, a neural network estimates tissue-specific parameters, and the predicted parameters are propagated through the differentiable forward model to reconstruct the observed measurements. The discrepancy between measured and reconstructed observations is then minimized jointly with parameter regularization. Bloch-equation constraints are appropriate for quantitative MRI, pharmacokinetic models for dynamic contrast-enhanced imaging and PET, and tissue- or modality-specific physical models for other quantitative biomarkers. Bayesian (for noisy data) or ensemble (for clean data) formulations should be adopted wherever parameter uncertainty is clinically relevant.
Page 37 of 51
Motion correction: The optimal strategy combines image-domain motion estimation with acquisition-domain consistency. The recommended workflow comprises motion detection, deformation-field estimation, physics-aware image correction and consistency enforcement against the acquired measurements. For MRI, k-space consistency ensures that corrected images remain compatible with the measured signal, while spatial-smoothness or biomechanical constraints regularize the estimated deformation fields. Transformer- or CNN-based architectures are well suited to motion estimation, and physics-based losses should constrain the corrected output rather than dominate feature learning.
Radiation dosimetry and treatment planning: The proposed workflow begins with patient-specific image segmentation and tissue-property estimation, followed by the incorporation of radiation-transport or dose-deposition models into the learning framework. A neural surrogate can then predict three-dimensional dose distributions while remaining consistent with the underlying physical model. Physics-based constraints should encompass energy deposition, attenuation, scattering and, where appropriate, tissue-dependent dose response. Evaluation should address both dosimetric accuracy and clinically relevant treatment objectives, rather than relying exclusively on data-driven prediction metrics.
Tumor progression and treatment-response modeling: These tasks demand the explicit integration of longitudinal observations with the biological mechanisms governing tumor growth, invasion and therapeutic response. We propose a longitudinal physics-informed workflow in which serial imaging and complementary patient-specific measurements first characterize tumor morphology, volume, spatial heterogeneity and quantitative biomarkers. These observations are then coupled with mechanistic models of proliferation, diffusion, invasion or treatment response within a physics-informed temporal framework. Patient-specific parameters are subsequently estimated through inverse learning, enabling the calibrated model to describe tumor evolution and to predict progression or response under specified therapeutic conditions. Uncertainty quantification should account for measurement noise, incomplete longitudinal observations, parameter uncertainty and mismatch between the assumed biological model and the true tumor dynamics.
Multimodal oncologic imaging: The literature suggests that physics should be incorporated at the modality level before cross-modal fusion. In the proposed workflow, each modality is first processed with its own forward model or physical constraint. The resulting physically consistent representations are then fused by cross-attention, transformer-based fusion or latent-space integration, with shared biological constraints, such as tumor location, tissue properties, perfusion or metabolic activity, providing additional cross-modal regularization. This strategy avoids imposing a single physical model across fundamentally different imaging modalities and affords a more interpretable basis for multimodal integration.
Model selection: Architectural choice should likewise be guided by the task. Coordinate-based PINNs and PIKANs are most appropriate for solving or identifying low-dimensional governing equations and for estimating unknown physical parameters. PICNNs and physics-guided encoder-decoder architectures are preferable for spatially resolved imaging problems, because convolutional differential operators reduce the computational burden associated with automatic differentiation. Neural operators are particularly attractive when repeated inference is required across varying patient-specific parameters, acquisition conditions or physical states. Transformer-based architectures are suited to long-range spatial or temporal dependencies and to multimodal fusion, whereas hybrid mechanistic-deep learning models are preferable when established biological or physiological models can be coupled with image-derived information.
8.1. Future Perspectives
Scientific foundation models, transfer learning and federated learning: Looking beyond task-specific optimization, future research is expected to progress towards unified, patient-specific imaging frameworks capable of supporting the entire oncologic care pathway, from tumor detection and localization to treatment planning, response assessment and disease monitoring. The emergence of Scientific foundation models (SciFMs) [30] presents a transformative paradigm in this respect. Pretraining on large, multiscale and heterogeneous medical-imaging datasets can improve generalization and reduce dependence on task-specific annotations. Nevertheless, preserving physical consistency, interpretability and robustness when such models extrapolate beyond their training distribution, or encounter extreme regimes, remains a critical challenge. In parallel, transfer learning (TL) [274–277] offers an important means of improving the scalability of PIDL under limited annotated data, by transferring physical representations learned from simulations, synthetic datasets or related anatomical domains to patient-specific oncologic imaging tasks. Future investigations should explore physics-preserving transfer mechanisms and architecture-level adaptation to improve robustness across
Page 38 of 51 heterogeneous cancer types, imaging protocols and scanner configurations. Further, federated learning (FL) [278–282] provides a privacy-preserving framework for multi-institutional training of PIDL, enabling collaborative learning across heterogeneous imaging protocols and scanners. The integration of personalization, differential privacy and robust federated optimization is expected to improve the clinical deployment of PIDL in collaborative oncologic imaging.
Digital twins and agentic PIDL: Digital twins [283–285] represent a promising direction for patient-specific PIDL frameworks that continuously integrate multimodal imaging, physiological measurements and clinical data to support tumor characterization, treatment planning and longitudinal therapy monitoring. Recent advances in physics-informed organ modeling, self-updating PINN frameworks and real-time surrogate modeling [286–289] provide the methodological foundation for adaptive oncologic digital twins capable of continuously refining patient-specific predictions. Future research should focus on integrating anatomical constraints, uncertainty quantification and privacy-preserving learning to enable reliable and clinically deployable digital twins for precision oncology [290]. Further, agentic artificial intelligence (AI) [291] offers an emerging route to adaptive PIDL systems that autonomously optimize, validate and refine physics-informed models. Drawing on advances in multi-agent scientific reasoning and physics-audited model verification [292, 293], future frameworks may enable reliable image reconstruction, tumor characterization, treatment planning and therapy monitoring while maintaining physical consistency.
Uncertainty Quantification: Uncertainty-aware [187, 207, 294–297] and interpretable PIDL [298, 299] are emerging as pivotal research directions for improving the clinical reliability and trustworthiness of oncologic imaging. Robust quantification of epistemic, aleatoric and model uncertainty is essential for deploying PIDL in high-stakes oncologic workflows, where inaccurate predictions can directly affect tumor targeting, dose calculation and treatment planning [18]. Whereas conventional deep learning methods often produce overconfident errors under distribution shift or noisy acquisition protocols, PIDL frameworks offer a distinct structural advantage: governing physical laws and Bayesian formulations act as regularizers that constrain the solution space and flag physically implausible outputs [294]. The integration of predictive and epistemic uncertainty into physics-informed models enables confidence-aware predictions and the identification of unreliable outcomes across diverse oncologic imaging tasks, thereby supporting risk-informed diagnostic and therapeutic decision-making. Future research must develop scalable uncertainty-aware techniques tailored to biomedical image simulation, reconstruction and physiological tracking, as well as to the modeling of complex biological dynamics in cancer cell populations, thereby enabling real-time confidence estimation during tumor segmentation, kinetic parameter mapping and longitudinal response assessment.
Interpretability: The black-box nature of standard neural networks remains a primary barrier to clinical adoption in oncology, as clinicians require transparent justification for diagnostic and therapeutic decisions. Interpretable PIDL addresses this limitation by embedding anatomical, physiological and biomechanical principles directly into network architectures and loss functions, ensuring that model predictions align with known biomedical laws rather than purely statistical correlations [32, 35, 300, 301]. Future developments should prioritize glass-box physics-informed representations, feature-attribution methods mapped to physical quantities (such as mass conservation, diffusion coefficients or wave-propagation parameters) and interactive visualization tools that allow clinicians to interrogate the physical consistency of model outputs. Unified frameworks that combine uncertainty quantification, inherent interpretability and clinician-in-the-loop decision support will be required to enable safe, robust and clinically deployable precision oncology systems.
Clinical translation and deployment: Clinical translation and real-world deployment constitute the decisive test for PIDL in oncologic imaging. Routine clinical adoption will require rigorous multi-center validation, standardized evaluation protocols and acquisition-agnostic models capable of generalizing across heterogeneous imaging systems and patient cohorts [268, 302]. Future efforts should also emphasize self-supervised and physics-constrained learning for patient-specific personalization, together with deployment-ready frameworks that support real-time clinical workflows, interoperability and regulatory-compliant validation. The challenges identified in this review, namely data scarcity, model fidelity, domain generalization, computational scalability, benchmarking and regulatory requirements, make clear that successful deployment depends not only on methodological advances but also on standardized evaluation, explainable decision-making and sustained collaboration among clinicians, medical physicists, imaging scientists, regulatory experts and AI researchers.
Page 39 of 51
8.2. Concluding remarks
PIDL is evolving from a promising research paradigm into a scientifically grounded framework for precision oncology, and its trajectory points towards a fundamental reconfiguration of how cancer is imaged, modeled and managed. We anticipate that the convergence of scientific foundation models, transfer and federated learning, neural operators, multimodal scientific learning, digital twins, uncertainty-aware Bayesian inference, trustworthy and explainable AI, and agentic scientific intelligence will progressively dissolve the boundaries between image acquisition, reconstruction, interpretation and therapeutic decision-making. In this envisioned paradigm, imaging will cease to be a static diagnostic snapshot and will instead become a continuously updated, physics-governed representation of the individual patient. Foundation models pretrained across scales, modalities and institutions could furnish transferable physical priors, while federated and privacy-preserving optimization allows these priors to be refined across global clinical networks without compromising patient confidentiality. Coupled with mechanistic tumor modeling and multimodal clinical data, patient-specific digital twins may then be calibrated longitudinally to simulate tumor evolution, to test candidate therapeutic strategies in silico before their administration, and to forecast treatment response with quantified confidence. Agentic PIDL systems, operating under physics-audited verification, could further automate model construction, validation and recalibration, shifting the role of the clinician from supervising individual computations to governing adaptive decision-support ecosystems. Realizing this vision will nevertheless depend on resolving the foundational questions identified in this review, namely guaranteeing physical consistency under extrapolation, establishing calibrated and clinically actionable uncertainty, ensuring interpretability that withstands regulatory and ethical scrutiny, and demonstrating clinical benefit through prospective multi-center validation. If these conditions are met, PIDL has the potential to unify imaging physics, tumor biology, mathematical modeling and machine learning within a single computational framework, delivering reliable, interpretable and clinically deployable AI systems that extend beyond correlation-driven learning towards physically consistent and biologically meaningful decision support in cancer care. Such a framework would not merely improve existing oncologic workflows but could establish the computational foundation for truly predictive, preventive and personalized oncology.
Page 40 of 51
A. Abbreviations
| Abbreviation | Definition |
|---|---|
| AD | Automatic Differentiation |
| BraTS | Brain Tumor Segmentation Challenge |
| CNN | Convolutional Neural Network |
| CT | Computed Tomography |
| DCE-MRI | Dynamic Contrast-Enhanced Magnetic Resonance Imaging |
| DECT | Dual-Energy Computed Tomography |
| DSC-MRI | Dynamic Susceptibility Contrast Magnetic Resonance Imaging |
| FDM | Finite Difference Method |
| FLAIR | Fluid-Attenuated Inversion Recovery |
| GDPR | General Data Protection Regulation |
| HIPAA | Health Insurance Portability and Accountability Act |
| IMRT | Intensity-Modulated Radiation Therapy |
| MedIA | Medical Image Analysis |
| MRI | Magnetic Resonance Imaging |
| NRMSE | Normalized Root Mean Squared Error |
| ODE | Ordinary Differential Equation |
| PDE | Partial Differential Equation |
| PET | Positron Emission Tomography |
| PICNN | Physics-Informed Convolutional Neural Network |
| PIDL | Physics-Informed Deep Learning |
| PIML | Physics-Informed Machine Learning |
| PINN | Physics-Informed Neural Network |
| PINO | Physics-Informed Neural Operators |
| PIGM | Physics-Informed Generative Models |
| PSNR | Peak Signal-to-Noise Ratio |
| qMRI | Quantitative Magnetic Resonance Imaging |
| SSIM | Structural Similarity Index |
| TC | Tumor Core |
| TCIA | The Cancer Imaging Archive |
| U-Net | U-shaped Convolutional Network |
| WT | Whole Tumor |
Page 41 of 51
References
[1] F. Bray, M. Laversanne, H. Sung, J. Ferlay, R. L. Siegel, I. Soerjomataram, A. Jemal, Global cancer statistics 2022: Globocan estimates of incidence and mortality worldwide for 36 cancers in 185 countries, CA Cancer J. Clin. 74 (2024) 229–263.
[2] L. A. Min, F. Castagnoli, W. V. Vogel, J. P. Vellenga, J. J. van Griethuysen, M. J. Lahaye, M. Maas, R. G. Beets Tan, D. M. Lambregts, A decade of multi-modality PET and MR imaging in abdominal oncology, Br. J. Radiol. 94 (2021) 20201351.
[3] D. O. Baguer, J. Leuschner, M. Schmidt, Computed tomography reconstruction using deep image prior and learned reconstruction methods, Inverse Probl. 36 (2020) 094004.
[4] A. Izhar, N. Idris, N. Japar, Medical radiology report generation: A systematic review of current deep learning methods, trends, and future directions, Artif. Intell. Med. (2025) 103220.
[5] O. Ronneberger, P. Fischer, T. Brox, U-Net: Convolutional networks for biomedical image segmentation, in: International Conference on Medical image computing and computer-assisted intervention, Springer, 2015, pp. 234–241.
[6] K. A. Tran, O. Kondrashova, A. Bradley, E. D. Williams, J. V. Pearson, N. Waddell, Deep learning in cancer diagnosis, prognosis and treatment selection, Genome Med. 13 (2021) 152.
[7] F. Shamshad, S. Khan, S. W. Zamir, M. H. Khan, M. Hayat, F. S. Khan, H. Fu, Transformers in medical imaging: A survey, Med. Image Anal. 88 (2023) 102802.
[8] R. Azad, E. K. Aghdam, A. Rauland, Y. Jia, A. H. Avval, A. Bozorgpour, S. Karimijafarbigloo, J. P. Cohen, E. Adeli, D. Merhof, Medical image segmentation review: The success of U-Net, IEEE Trans. Pattern Anal. Mach. Intell. 46 (2024) 10076–10095.
[9] D. Fotopoulos, I. Ladakis, D. Filos, P. A. Moreno-Sánchez, M. van Gils, I. Chouvarda, Explainable AI in cancer imaging: Scoping review of methods, modalities, and clinical integration, J. Med. Internet Res. 28 (2026) e80645.
[10] O. G. Adegboro, J. Dietlmeier, N. E. O'Connor, C. Mazo, Artificial intelligence based techniques for brain tumor analysis: A systematic review, Artif. Intell. Med. (2026) 103460.
[11] I. Z. Yao, M. Dong, W. Y. Hwang, Deep learning applications in clinical cancer detection: a review of implementation challenges and solutions, Mayo Clin. Proc. Digit. Health (2025) 100253.
[12] M. Ennab, H. Mcheick, Enhancing interpretability and accuracy of AI models in healthcare: a comprehensive review on challenges and future directions, Front. Robot. AI 11 (2024) 1444763.
[13] S. Arridge, P. Maass, O. Öktem, C.-B. Schönlieb, Solving inverse problems using data-driven models, Acta Numer. 28 (2019) 1–174.
[14] M. Raissi, P. Perdikaris, G. E. Karniadakis, Physics-informed neural networks: A deep learning framework for solving forward and inverse problems involving nonlinear partial differential equations, Journal of Computational Physics 378 (2019) 686–707.
[15] C. Banerjee, K. Nguyen, O. Salvado, T. Tran, C. Fookes, Physics-informed machine learning for medical image analysis, ACM Comput. Surv. 58 (2025) 1–35.
[16] S. Cuomo, V. S. Di Cola, F. Giampaolo, G. Rozza, M. Raissi, F. Piccialli, Scientific machine learning through physics-informed neural networks: Where we are and what's next, J. Sci. Comput. 92 (2022) 88.
[17] P. Das, A. Amin, K. Hasan, R. Thompson, A. D. Okpalaeze, L. Hong, Physics-embedded feature learning for AI in medical imaging, in: SoutheastCon 2026, IEEE, 2026, pp. 1–7.
[18] N. Ahmadi, Q. Cao, J. D. Humphrey, G. E. Karniadakis, Physics-informed machine learning in biomedical science and engineering, Annu. Rev. Biomed. Eng. 28 (2026) 309–336.
[19] A. D. Jagtap, K. Kawaguchi, G. E. Karniadakis, Adaptive activation functions accelerate convergence in deep and physics-informed neural networks, J. Comput. Phys. 404 (2020) 109136.
[20] A. D. Jagtap, K. Kawaguchi, G. E. Karniadakis, Locally adaptive activation functions with slope recovery for deep and physics-informed neural networks, Proc. R. Soc. A 476 (2020) 20200334.
[21] J. Abbasi, A. D. Jagtap, B. Moseley, A. Hiorth, P. Ø. Andersen, Challenges and advancements in modeling shock fronts with physics-informed neural networks: A review and benchmarking study, Neurocomputing (2025) 131440.
[22] J. Abbasi, B. Moseley, T. Kurotori, A. D. Jagtap, A. R. Kovscek, A. Hiorth, P. Ø. Andersen, History-matching of imbibition flow in fractured porous media using physics-informed neural networks (PINNs), Comput. Methods Appl. Mech. Eng. 437 (2025) 117784.
[23] A. D. Jagtap, Z. Mao, N. Adams, G. E. Karniadakis, Physics-informed neural networks for inverse problems in supersonic flows, J. Comput. Phys. 466 (2022) 111402.
[24] A. D. Jagtap, D. Mitsotakis, G. E. Karniadakis, Deep learning of inverse water waves problems using multi-fidelity data: Application to Serre–Green–Naghdi equations, Ocean Eng. 248 (2022) 110775.
[25] A. D. Jagtap, Y. Shin, K. Kawaguchi, G. E. Karniadakis, Deep Kronecker neural networks: A general framework for neural networks with adaptive activation functions, Neurocomputing 468 (2022) 165–180.
[26] S. S. Menon, M. Lavari, A. Kokernak, J. Mathew, C. A. Jagtap, J. Jayachandran, A. Gnanaskandan, A. D. Jagtap, Intelligent fluid flows: A survey of deep learning methods for turbulent flows, multiphase flows, and combustion, Neurocomputing 697 (2026) 134117.
[27] H. N. Mhaskar, E. Tsoukanis, A. D. Jagtap, An approximation theory perspective on machine learning, Neural Networks 200 (2026) 108841.
[28] A. D. Jagtap, G. E. Karniadakis, Extended physics-informed neural networks (XPINNs): A generalized space-time domain decomposition based deep learning framework for nonlinear partial differential equations, Commun. Comput. Phys. 28 (2020).
[29] A. D. Jagtap, E. Kharazmi, G. E. Karniadakis, Conservative physics-informed neural networks on discrete domains for conservation laws: Applications to forward and inverse problems, Comput. Methods Appl. Mech. Eng. 365 (2020) 113028.
[30] S. S. Menon, T. Mondal, S. Brahmachary, A. Panda, S. M. Joshi, K. Kalyanaraman, A. D. Jagtap, On scientific foundation models: Rigorous definitions, key applications, and a comprehensive survey, Neural Netw. (2026) 108567.
[31] L. Lu, P. Jin, G. E. Karniadakis, Deeponet: Learning nonlinear operators for identifying differential equations based on the universal approximation theorem of operators, arXiv preprint arXiv:1910.03193 (2019).
[32] Y. Zhang, S. S. Menon, L. Cheng, A. Gnanaskandan, A. D. Jagtap, Bubbleokan: A physics-informed interpretable neural operator for high-frequency bubble dynamics, Computer Methods in Applied Mechanics and Engineering 450 (2026) 118667.
Page 42 of 51
[33] S. Goswami, A. D. Jagtap, H. Babaee, B. T. Susi, G. E. Karniadakis, Learning stiff chemical kinetics using extended deep neural operators, Computer Methods in Applied Mechanics and Engineering 419 (2024) 116674.
[34] X. Zhao, Z. Gong, Y. Zhang, W. Yao, X. Chen, Physics-informed convolutional neural networks for temperature field prediction of heat source layout without labeled data, Eng. Appl. Artif. Intell. 117 (2023) 105516.
[35] S. S. Menon, A. D. Jagtap, Fekan: Feature-enriched kolmogorov–arnold networks, Computer Methods in Applied Mechanics and Engineering 461 (2026) 119141.
[36] D. Poovesh, M. Ragul, M. Ragupathy, et al., A bio-physical attention framework for decoupled vascular and structural disease modeling, in: 2025 International Conference on Emerging Research in Computational Science (ICERCS), IEEE, 2025, pp. 1–8.
[37] Z. Zhao, X. Ding, B. A. Prakash, Pinnsformer: A transformer-based framework for physics-informed neural networks, arXiv preprint arXiv:2307.11833 (2023).
[38] R. Gou, Y. Zhang, X. Zhu, J. Gao, Bayesian physics-informed neural networks for the subsurface tomography based on the eikonal equation, IEEE Trans. Geosci. Remote Sens. 61 (2023) 1–12.
[39] K. Hammernik, T. Küstner, B. Yaman, Z. Huang, D. Rueckert, F. Knoll, M. Akçakaya, Physics-driven deep learning for computational magnetic resonance imaging: Combining physics and machine learning for improved medical imaging, IEEE Signal Process. Mag. 40 (2023) 98–114.
[40] S. Nemirovsky-Rotman, E. Bercovich, Explicit physics-informed deep learning for computer-aided diagnostic tasks in medical imaging, Machine Learning and Knowledge Extraction 6 (2024) 385–401.
[41] Y. Yogita, T. W. Bocklitz, Advances in physics-informed deep learning for imaging data: A review of methods and applications, Journal of Physics: Photonics 7 (2025) 042002.
[42] M. Ahmadi, D. Biswas, M. Lin, F. D. Vrionis, J. Hashemi, Y. Tang, Physics-informed machine learning for advancing computational medical imaging: Integrating data-driven approaches with fundamental physical principles, Artificial Intelligence Review 58 (2025) 297.
[43] G. E. Karniadakis, I. G. Kevrekidis, L. Lu, P. Perdikaris, S. Wang, L. Yang, Physics-informed machine learning, Nature Reviews Physics 3 (2021) 422–440.
[44] A. D. Jagtap, The limits of exactness: On the failure of automatic differentiation in physics-informed machine learning, arXiv preprint arXiv:2609.33078 (2026).
[45] A. G. Baydin, B. A. Pearlmutter, A. A. Radul, J. M. Siskind, Automatic differentiation in machine learning: a survey, J. Mach. Learn. Res. 18 (2018) 1–43.
[46] S. Wang, Y. Teng, P. Perdikaris, Understanding and mitigating gradient flow pathologies in physics-informed neural networks, SIAM Journal on Scientific Computing 43 (2021) A3055–A3081.
[47] A. Krishnapriyan, A. Gholami, S. Zhe, R. Kirby, M. Mahoney, Characterizing possible failure modes in physics-informed neural networks, Advances in neural information processing systems 34 (2021) 26548–26560.
[48] Z. Liu, Y. Wang, S. Vaidya, F. Ruehle, J. Halverson, M. Soljacic, T. Hou, M. Tegmark, Kan: Kolmogorov-arnold networks, in: International conference on learning representations, volume 2025, 2025, pp. 70367–70413.
[49] S. Patra, S. Panda, B. K. Parida, M. Arya, K. Jacobs, D. I. Bondar, A. Sen, Physics informed Kolmogorov–Arnold neural networks for dynamical analysis via efficient-KAN and WAV-KAN, Journal of Machine Learning Research 26 (2025) 1–39.
[50] S. Rigas, M. Papachristou, T. Papadopoulos, F. Anagnostopoulos, G. Alexandridis, Adaptive training of grid-dependent physics-informed Kolmogorov–Arnold networks, IEEE Access 12 (2024) 176982–176998.
[51] Z. Zhang, Q. Wang, Y. Zhang, T. Shen, W. Zhang, Physics-informed neural networks with hybrid Kolmogorov–Arnold network and augmented Lagrangian function for solving partial differential equations, Scientific Reports 15 (2025) 10523.
[52] K. Shukla, J. D. Toscano, Z. Wang, Z. Zou, G. E. Karniadakis, A comprehensive and fair comparison between mlp and kan representations for differential equations and operator networks, Computer Methods in Applied Mechanics and Engineering 431 (2024) 117290.
[53] Z. Hao, J. Yao, C. Su, H. Su, Z. Wang, F. Lu, Z. Xia, Y. Zhang, S. Liu, L. Lu, et al., Pinnacle: A comprehensive benchmark of physics-informed neural networks for solving PDEs, Adv. Neural Inf. Process. Syst. 37 (2024) 76721–76774.
[54] P. Ren, C. Rao, Y. Liu, J.-X. Wang, H. Sun, Phycnet: Physics-informed convolutional-recurrent network for solving spatiotemporal PDEs, Comput. Methods Appl. Mech. Eng. 389 (2022) 114399.
[55] Z. Fang, A high-efficient hybrid physics-informed neural networks based on convolutional neural network, IEEE Trans. Neural Netw. Learn. Syst. 33 (2021) 5514–5526.
[56] M. Zarei, S. Sotoudeh-Paima, C. McCabe, E. Abadi, E. Samei, A physics-informed deep neural network for harmonization of ct images, IEEE Trans. Biomed. Eng. 71 (2024) 3494–3504.
[57] R. Lin, J. Zhang, A novel approach to biomechanical modeling: Ct image weight initialization and physics informed neural networks, Biomed. Signal Process. Control 109 (2025) 107939.
[58] N. Kovachki, Z. Li, B. Liu, K. Azizzadenesheli, K. Bhattacharya, A. Stuart, A. Anandkumar, Neural operator: Learning maps between function spaces with applications to PDEs, J. Mach. Learn. Res. 24 (2023) 1–97.
[59] Z. Hao, Z. Wang, H. Su, C. Ying, Y. Dong, S. Liu, Z. Cheng, J. Song, J. Zhu, Gnot: A general neural operator transformer for operator learning, in: International conference on machine learning, PMLR, 2023, pp. 12556–12569.
[60] N. Kovachki, S. Lanthaler, S. Mishra, On universal approximation and error bounds for fourier neural operators, J. Mach. Learn. Res. 22 (2021) 1–76.
[61] Z. Li, D. Z. Huang, B. Liu, A. Anandkumar, Fourier neural operator with learned deformations for PDEs on general geometries, J. Mach. Learn. Res. 24 (2023) 1–26.
[62] S. Wang, H. Wang, P. Perdikaris, Learning the solution operator of parametric partial differential equations with physics-informed deeponets, Science advances 7 (2021) eabi8605.
[63] T. Tripura, A. Awasthi, S. Roy, S. Chakraborty, A wavelet neural operator based elastography for localization and quantification of tumors, Comput. Methods Programs Biomed. 232 (2023) 107436.
Page 43 of 51
[64] Z. Zeng, Y. Zheng, Y. Zheng, Y. Li, Z. Shi, H. Sun, Neural born series operator for biomedical ultrasound computed tomography, arXiv preprint arXiv:2312.15575 (2023).
[65] L. Yang, D. Zhang, G. E. Karniadakis, Physics-informed generative adversarial networks for stochastic differential equations, SIAM Journal on Scientific Computing 42 (2020) A292–A317.
[66] C. Jacobsen, Y. Zhuang, K. Duraisamy, Cocogen: Physically consistent and conditioned score-based generative models for forward and inverse problems, SIAM Journal on Scientific Computing 47 (2025) C399–C425.
[67] J.-H. Bastek, W. Sun, D. Kochmann, Physics-informed diffusion models, in: International Conference on Learning Representations, volume 2025, 2025, pp. 3360–3385.
[68] T. Mondal, P. Bharadwaj, N. Karanjgaokar, A. D. Jagtap, Genvoid: Uncertainty-aware learning of subsurface material defects with an experimentally validated physics-informed generative model, arXiv preprint arXiv:2609.23761 (2026).
[69] L. Yang, X. Meng, G. E. Karniadakis, B-PINNs: Bayesian physics-informed neural networks for forward and inverse PDE problems with noisy data, J. Comput. Phys. 425 (2021) 109913.
[70] K. Linka, A. Schäfer, X. Meng, Z. Zou, G. E. Karniadakis, E. Kuhl, Bayesian physics informed neural networks for real-world nonlinear dynamical systems, Comput. Methods Appl. Mech. Eng. 402 (2022) 115346.
[71] J. P. Molnar, S. J. Grauer, Flow field tomography with uncertainty quantification using a bayesian physics-informed neural network, Meas. Sci. Technol. 33 (2022) 065305.
[72] J. Huang, G. Yang, Z. Wang, J. J. Park, Diffusionpde: Generative pde-solving under partial observation, Advances in Neural Information Processing Systems 37 (2024) 130291–130323.
[73] N. Casali, A. Brusaferri, G. Baselli, S. Fumagalli, E. Micotti, G. Forloni, R. Hussein, G. Rizzo, A. Mastropietro, Physics-informed cnn ensemble for improved tissue perfusion and diffusion estimation with uncertainty quantification in ivim MRI, in: International Conference on Artificial Intelligence in Medicine, Springer, 2025, pp. 89–93.
[74] M. De Florio, Z. Zou, D. E. Schiavazzi, G. E. Karniadakis, Quantification of total uncertainty in the physics-informed reconstruction of cvsim-6 physiology, Philos. Trans. R. Soc. A Math. Phys. Eng. Sci. 383 (2025).
[75] F. Shih, Z. Jiang, F. Liang, Uncertainty quantification for physics-informed neural networks with extended fiducial inference, Adv. Neural Inf. Process. Syst. 38 (2026) 75361–75397.
[76] I. E. Lagaris, A. Likas, D. I. Fotiadis, Artificial neural networks for solving ordinary and partial differential equations, IEEE transactions on neural networks 9 (1998) 987–1000.
[77] S. L. Brunton, J. L. Proctor, J. N. Kutz, Discovering governing equations from data by sparse identification of nonlinear dynamical systems, Proceedings of the national academy of sciences 113 (2016) 3932–3937.
[78] B. Yu, et al., The deep ritz method: a deep learning-based numerical algorithm for solving variational problems, Communications in Mathematics and Statistics 6 (2018) 1–12.
[79] J. Sirignano, K. Spiliopoulos, Dgm: A deep learning algorithm for solving partial differential equations, Journal of computational physics 375 (2018) 1339–1364.
[80] S. Greydanus, M. Dzamba, J. Yosinski, Hamiltonian neural networks, Advances in neural information processing systems 32 (2019).
[81] G. Pang, L. Lu, G. E. Karniadakis, fpinns: Fractional physics-informed neural networks, SIAM Journal on Scientific Computing 41 (2019) A2603–A2626.
[82] M. Cranmer, S. Greydanus, S. Hoyer, P. Battaglia, D. Spergel, S. Ho, Lagrangian neural networks, arXiv preprint arXiv:2003.04630 (2020).
[83] E. Kharazmi, Z. Zhang, G. E. Karniadakis, hp-vpinns: Variational physics-informed neural networks with domain decomposition, Computer Methods in Applied Mechanics and Engineering 374 (2021) 113547.
[84] J. Yu, L. Lu, X. Meng, G. E. Karniadakis, Gradient-enhanced physics-informed neural networks for forward and inverse pde problems, Computer Methods in Applied Mechanics and Engineering 393 (2022) 114823.
[85] S. S. Menon, I. Tezaur, A. D. Jagtap, Tackling failure modes of pinns and pikans using conflict-free gradients, arXiv preprint arXiv:2609.14841 (2026).
[86] L. Lu, P. Jin, G. Pang, Z. Zhang, G. E. Karniadakis, Learning nonlinear operators via DeepONet based on the universal approximation theorem of operators, Nat. Mach. Intell. 3 (2021) 218–229.
[87] Z. Li, N. Kovachki, K. Azizzadenesheli, B. Liu, K. Bhattacharya, A. Stuart, A. Anandkumar, Fourier neural operator for parametric partial differential equations, arXiv preprint arXiv:2010.08895 (2020).
[88] Z. Li, H. Zheng, N. Kovachki, D. Jin, H. Chen, B. Liu, K. Azizzadenesheli, A. Anandkumar, Physics-informed neural operator for learning partial differential equations, ACM/IMS J. Data Sci. 1 (2024) 1–27.
[89] Z. Li, N. Kovachki, C. Choy, B. Li, J. Kossaifi, S. Otta, M. A. Nabian, M. Stadler, C. Hundt, K. Azizzadenesheli, et al., Geometry-informed neural operator for large-scale 3d pdes, Advances in Neural Information Processing Systems 36 (2023) 35836–35854.
[90] J. Pathak, S. Subramanian, P. Harrington, S. Raja, A. Chattopadhyay, M. Mardani, T. Kurth, D. Hall, Z. Li, K. Azizzadenesheli, et al., Fourcastnet: A global data-driven high-resolution weather model using adaptive fourier neural operators, arXiv preprint arXiv:2202.11214 (2022).
[91] Y. Wang, J. Sun, J. Bai, C. Anitescu, M. S. Eshaghi, X. Zhuang, T. Rabczuk, Y. Liu, Kolmogorov-arnold-informed neural network: A physics-informed deep learning framework for solving forward and inverse problems based on kolmogorov-arnold networks, Computer Methods in Applied Mechanics and Engineering 433 (2025) 117518.
[92] A. Harandi, A. Moeineddin, M. Kaliske, S. Reese, S. Rezaei, Mixed formulation of physics-informed neural networks for thermo-mechanically coupled systems and heterogeneous domains, International Journal for Numerical Methods in Engineering 125 (2024) e7388.
[93] O. Y. L. Imanov, Multi-fidelity physics-informed neural networks with bayesian uncertainty quantification and adaptive residual learning for efficient solution of parametric partial differential equations, arXiv preprint arXiv:2602.01176 (2026).
[94] H. Huang, L. Lin, R. Tong, H. Hu, Q. Zhang, Y. Iwamoto, X. Han, Y.-W. Chen, J. Wu, Unet 3+: A full-scale connected unet for medical image segmentation, in: ICASSP 2020-2020 IEEE international conference on acoustics, speech and signal processing (ICASSP), Ieee, 2020,
Page 44 of 51 pp. 1055–1059.
[95] J. Ruan, J. Li, S. Xiang, Vm-unet: Vision mamba unet for medical image segmentation, ACM Trans. Multimed. Comput. Commun. Appl. (2024).
[96] L. Huang, A. Miron, K. Hone, Y. Li, Segmenting medical images: from unet to res-unet and nnunet, in: 2024 IEEE 37th International Symposium on Computer-Based Medical Systems (CBMS), IEEE, 2024, pp. 483–489.
[97] H. Cao, Y. Wang, J. Chen, D. Jiang, X. Zhang, Q. Tian, M. Wang, Swin-unet: Unet-like pure transformer for medical image segmentation, in: European conference on computer vision, Springer, 2022, pp. 205–218.
[98] A. Hatamizadeh, Y. Tang, V. Nath, D. Yang, A. Myronenko, B. Landman, H. R. Roth, D. Xu, Unetr: Transformers for 3d medical image segmentation, in: Proceedings of the IEEE/CVF winter conference on applications of computer vision, 2022, pp. 574–584.
[99] N. Siddique, S. Paheding, C. P. Elkin, V. Devabhaktuni, U-Net and its variants for medical image segmentation: A review of theory and applications, IEEE Access 9 (2021) 82031–82057.
[100] H. Lu, Y. She, J. Tie, S. Xu, Half-unet: A simplified U-Net architecture for medical image segmentation, Front. Neuroinform. 16 (2022) 911679.
[101] D. Jha, M. A. Riegler, D. Johansen, P. Halvorsen, H. D. Johansen, DoubleU-Net: A deep convolutional neural network for medical image segmentation, in: 2020 IEEE 33rd International symposium on computer-based medical systems (CBMS), IEEE, 2020, pp. 558–564.
[102] K. D. Shah, D. K. Patel, M. P. Thaker, H. A. Patel, M. J. Saikia, B. J. Ranger, Emed-unet: an efficient multi-encoder-decoder based unet for medical image segmentation, IEEE Access 11 (2023) 95253–95266.
[103] T. Shan, J. Yan, X. Cui, L. Xie, Dsca-net: A depthwise separable convolutional neural network with attention mechanism for medical image segmentation, Math. Biosci. Eng. 20 (2023) 365–382.
[104] Y. Peng, D. Z. Chen, M. Sonka, U-Net v2: Rethinking the skip connections of U-Net for medical image segmentation, in: 2025 IEEE 22nd International Symposium on Biomedical Imaging (ISBI), IEEE, 2025, pp. 1–5.
[105] M. Z. Alom, M. Hasan, C. Yakopcic, T. M. Taha, V. K. Asari, Recurrent residual convolutional neural network based on U-Net (r2U-Net) for medical image segmentation, arXiv preprint arXiv:1802.06955 (2018).
[106] C. Xin, Z. Liu, K. Zhao, L. Miao, Y. Ma, X. Zhu, Q. Zhou, S. Wang, L. Li, F. Yang, et al., An improved transformer network for skin cancer classification, Comput. Biol. Med. 149 (2022) 105939.
[107] Z. Jiao, X. Peng, Y. Wang, J. Xiao, D. Nie, X. Wu, X. Wang, J. Zhou, D. Shen, Transdose: Transformer-based radiotherapy dose prediction from ct images guided by super-pixel-level gcn classification, Med. Image Anal. 89 (2023) 102902.
[108] H. Xiao, L. Li, Q. Liu, X. Zhu, Q. Zhang, Transformers in medical image segmentation: A review, Biomed. Signal Process. Control 84 (2023) 104791.
[109] Y. Chen, T. Wang, H. Tang, L. Zhao, X. Zhang, T. Tan, Q. Gao, M. Du, T. Tong, Cotrfuse: a novel framework by fusing cnn and transformer for medical image segmentation, Phys. Med. Biol. 68 (2023) 175027.
[110] M. Tan, Q. Le, Efficientnet: Rethinking model scaling for convolutional neural networks, in: International conference on machine learning, PMLR, 2019, pp. 6105–6114.
[111] Z. Liu, Y. Lin, Y. Cao, H. Hu, Y. Wei, Z. Zhang, S. Lin, B. Guo, Swin transformer: Hierarchical vision transformer using shifted windows, in: Proceedings of the IEEE/CVF international conference on computer vision, 2021, pp. 10012–10022.
[112] R. Chen, S. He, J. Xie, T. Wang, Y. Xu, J. Fang, X. Zhao, S. Zhang, G. Wang, H. Lu, et al., Medfusenet: fusing local and global deep feature representations with hybrid attention mechanisms for medical image segmentation, Sci. Rep. 15 (2025) 5093.
[113] S. Perera, P. Navard, A. Yilmaz, Segformer3d: an efficient transformer for 3d medical image segmentation, in: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 2024, pp. 4981–4988.
[114] Z. Peng, W. Huang, S. Gu, L. Xie, Y. Wang, J. Jiao, Q. Ye, Conformer: Local features coupling global representations for visual recognition, in: Proceedings of the IEEE/CVF international conference on computer vision, 2021, pp. 367–376.
[115] J. Chen, J. Mei, X. Li, Y. Lu, Q. Yu, Q. Wei, X. Luo, Y. Xie, E. Adeli, Y. Wang, et al., Transunet: Rethinking the U-Net architecture design for medical image segmentation through the lens of transformers, Med. Image Anal. 97 (2024) 103280.
[116] Y. Bhalgat, M. Shah, S. Awate, Annotation-cost minimization for medical image segmentation using suggestive mixed supervision fully convolutional networks, arXiv preprint arXiv:1812.11302 (2018).
[117] C. Qu, T. Zhang, H. Qiao, Y. Tang, A. L. Yuille, Z. Zhou, et al., Abdomenatlas-8k: Annotating 8,000 ct volumes for multi-organ segmentation in three weeks, Adv. Neural Inf. Process. Syst. 36 (2023) 36620–36636.
[118] S. Wang, C. Li, R. Wang, Z. Liu, M. Wang, H. Tan, Y. Wu, X. Liu, H. Sun, R. Yang, et al., Annotation-efficient deep learning for automatic medical image segmentation, Nat. Commun. 12 (2021) 5915.
[119] D. Veiga-Canuto, L. Cerdà-Alberich, C. Sangüesa Nebot, B. Martínez de las Heras, U. Pötschger, M. Gabelloni, J. M. Carot Sierra, S. Taschner-Mandl, V. Düster, A. Cañete, et al., Comparative multicentric evaluation of inter-observer variability in manual and automatic segmentation of neuroblastic tumors in magnetic resonance images, Cancers (Basel) 14 (2022) 3648.
[120] B. Guo, D. Lu, G. Szumel, R. Gui, P. Li, T. Wang, N. Konz, M. A. Mazurowski, The impact of scanner domain shift on deep learning performance in medical imaging: an experimental study, Int. J. Comput. Assist. Radiol. Surg. (2026) 1–11.
[121] T. Qamar, N. Z. Bawany, Understanding the black-box: towards interpretable and reliable deep learning models, PeerJ Comput. Sci. 9 (2023) e1629.
[122] N. A. Wani, R. Kumar, J. Bedi, Deepexplainer: An interpretable deep learning based approach for lung cancer detection using explainable artificial intelligence, Comput. Methods Programs Biomed. 243 (2024) 107879.
[123] F. M. Talaat, S. A. Gamel, R. M. El-Balka, M. Shehata, H. ZainEldin, Grad-cam enabled breast cancer classification with a 3d inception-resnet v2: Empowering radiologists with explainable insights, Cancers (Basel) 16 (2024) 3668.
[124] R. Mothkur, P. Soubhagyalakshmi, et al., Grad-cam based visualization for interpretable lung cancer categorization using deep cnn models, J. Electron. Electromed. Eng. Med. Inform. 7 (2025) 567–580.
[125] M. Nickparvar, Brain tumor MRI dataset, Kaggle dataset, Version 2, 2021. Image file: Te-no_114.jpg; licensed under CC BY 4.0.
Page 45 of 51
[126] R. K. Jain, Transport of molecules in the tumor interstitium: a review, Cancer Res. 47 (1987) 3039–3051.
[127] T. Roose, S. J. Chapman, P. K. Maini, Mathematical models of avascular tumor growth, SIAM Rev. 49 (2007) 179–208.
[128] L. T. Baxter, R. K. Jain, Transport of fluid and macromolecules in tumors. i. role of interstitial pressure and convection, Microvasc. Res. 37 (1989) 77–104.
[129] V. P. Collins, R. K. Loeffler, H. Tivey, Observations on growth rates of human tumors, Am J Roentgenol Radium Ther Nucl Med 76 (1956) 988–1000.
[130] N. Bacaer, Verhulst and the logistic equation (1838), in: A short history of mathematical population dynamics, Springer, 2011, pp. 35–39.
[131] B. Gompertz, On the nature of the function expressive of the law of human mortality, and on a new mode of determining the value of life contingencies., in: Abstracts of the Papers Printed in the Philosophical Transactions of the Royal Society of London, volume 2, JSTOR, 1825, pp. 252–253.
[132] P. Hahnfeldt, D. Panigrahy, J. Folkman, L. Hlatky, Tumor development under angiogenic signaling: a dynamical theory of tumor growth, treatment response, and postvascular dormancy, Cancer research 59 (1999) 4770–4775.
[133] R. A. Fisher, The wave of advance of advantageous genes, Annals of eugenics 7 (1937) 355–369.
[134] A. N. Kolmogorov, N. Piskunov, Studies of the diffusion with the increasing quantity of the substance; its application to a biological problem, in: Differential Equations, CRC Press, 2019, pp. 106–132.
[135] K. R. Swanson, E. C. Alvord, J. D. Murray, A quantitative model for differential motility of gliomas in grey and white matter, Cell Proliferation 33 (2000) 317–329.
[136] A. R. Anderson, M. A. Chaplain, Continuous and discrete mathematical models of tumor-induced angiogenesis, Bulletin of mathematical biology 60 (1998) 857–899.
[137] R. K. Jain, L. T. Baxter, Mechanisms of heterogeneous distribution of monoclonal antibodies and other macromolecules in tumors: significance of elevated interstitial pressure, Cancer research 48 (1988) 7022–7032.
[138] M. Fritz, P. K. Jha, T. Köppl, J. T. Oden, A. Wagner, B. Wohlmuth, Modeling and simulation of vascular tumors embedded in evolving capillary networks, Computer Methods in Applied Mechanics and Engineering 384 (2021) 113975.
[139] S. M. Wise, J. S. Lowengrub, H. B. Frieboes, V. Cristini, Three-dimensional multispecies nonlinear tumor growth—i: model and numerical method, Journal of theoretical biology 253 (2008) 524–543.
[140] G. Lorenzo, J. S. Heiselman, M. A. Liss, M. I. Miga, H. Gomez, T. E. Yankeelov, A. Reali, T. J. Hughes, A pilot study on patient-specific computational forecasting of prostate cancer growth during active surveillance using an imaging-informed biomechanistic model, Cancer research communications 4 (2024) 617–633.
[141] G. Lorenzo, S. R. Ahmed, D. A. Hormuth, B. Vaughn, J. Kalpathy-Cramer, L. Solorio, T. E. Yankeelov, H. Gomez, Patient-specific, mechanistic models of tumor growth incorporating artificial intelligence and big data, Annual Review of Biomedical Engineering 26 (2024) 529–560.
[142] H. K. Aggarwal, M. P. Mani, M. Jacob, MoDL: Model-based deep learning architecture for inverse problems, IEEE Trans. Med. Imaging 38 (2019) 394–405.
[143] W. Xia, H. Shan, G. Wang, Y. Zhang, Physics-/model-based and data-driven methods for low-dose computed tomography: A survey, IEEE Signal Process. Mag. 40 (2023) 89–100.
[144] S. Han, Y. Xu, D. Wang, B. Morovati, L. Zhou, J. S. Maltz, G. Wang, H. Yu, Physics-informed score-based diffusion model for limited-angle reconstruction of cardiac computed tomography, IEEE Trans. Med. Imaging 44 (2025) 3629–3640.
[145] Y. Xie, X. Li, Y. Hu, C. Liu, H. Liang, D. Nickel, C. Fu, S. Chen, H. Tao, Deep learning reconstruction for turbo spin echo to prospectively accelerate ankle MRI: A multi-reader study, Eur. J. Radiol. 175 (2024) 111451.
[146] H. Almansour, J. Herrmann, S. Gassenmaier, S. Afat, J. Jacoby, G. Koerzdoerfer, D. Nickel, M. Mostapha, M. Nadar, A. E. Othman, Deep learning reconstruction for accelerated spine MRI: Prospective analysis of interchangeability, Radiology 306 (2023) e212922. PMID: 36318032.
[147] A. Rajagopal, A. P. Leynes, N. Dwork, J. E. Scholey, T. A. Hope, P. E. Larson, Physics-driven deep learning for PET/MRI, arXiv preprint arXiv:2206.06788 (2022).
[148] G. Jeong, F. Li, T. M. Mitcham, U. Villa, N. Duric, M. A. Anastasio, Investigating the use of traveltime and reflection tomography for deep learning-based sound-speed estimation in ultrasound computed tomography, IEEE Trans. Ultrason. Ferroelectr. Freq. Control 71 (2024) 1358–1376.
[149] R. Zhang, Y. Kvich, R. Guo, O. Cohen, Y. C. Eldar, Physics informed deep unfolded full waveform inversion for edema detection, arXiv preprint arXiv:2603.04070 (2026).
[150] J. Zbontar, F. Knoll, A. Sriram, T. Murrell, Z. Huang, M. J. Muckley, A. Defazio, R. Stern, P. Johnson, M. Bruno, et al., fastMRI: An open dataset and benchmarks for accelerated MRI, arXiv preprint arXiv:1811.08839 (2018).
[151] C. McCollough, Tu-fg-207a-04: overview of the low dose ct grand challenge, Med. Phys. 43 (2016) 3759–3760.
[152] K. Clark, B. Vendt, K. Smith, J. Freymann, J. Kirby, P. Koppel, S. Moore, S. Phillips, D. Maffitt, M. Pringle, et al., The cancer imaging archive (tcia): maintaining and operating a public information repository, J. Digit. Imaging 26 (2013) 1045–1057.
[153] C. A. Cocosco, V. Kollokian, R. K.-S. Kwan, A. C. Evans, BrainWeb: Online interface to a 3d MRI simulated brain database, Neuroimage 5 (1997) S425.
[154] L. A. Shepp, B. F. Logan, The fourier reconstruction of a head section, IEEE Trans. Nucl. Sci. 21 (1974) 21–43.
[155] Z. Wang, A. C. Bovik, Mean squared error: Love it or leave it? a new look at signal fidelity measures, IEEE Signal Process. Mag. 26 (2009) 98–117.
[156] A. C. Kak, M. Slaney, Principles of Computerized Tomographic Imaging, Society for Industrial and Applied Mathematics, Philadelphia, PA, 2001. doi:10.1137/1.9780898719277.
[157] A. Beer, Bestimmung der absorption des rothen Lichts in farbigen flüssigkeiten (determination of the absorption of red light in coloured liquids), Ann. Phys. Chem. 162 (1852) 78–88.
Page 46 of 51
[158] D. A. Chesler, S. J. Riederer, N. J. Pelc, Noise due to photon counting statistics in computed X-ray tomography, J. Comput. Assist. Tomogr. 1 (1977) 64–74.
[159] C. O. Quero, M. L. Crespo, Physics-informed neural network for denoising images using nonlinear PDE, Electronics 15 (2026) 560.
[160] N. Yuan, J. Zhou, K. Gong, J. Qi, Low-dose CT count-domain denoising via convolutional neural network with filter loss, in: Medical Imaging 2019: Physics of Medical Imaging, volume 10948 of Proceedings of SPIE, 2019, p. 109480R. doi:10.1117/12.2513479.
[161] A. Mehranian, A. J. Reader, Model-based deep learning PET image reconstruction using forward-backward splitting expectation-maximization, IEEE Trans. Radiat. Plasma Med. Sci. 5 (2021) 54–64.
[162] F. F. Zimmermann, C. Kolbitsch, P. Schuenke, A. Kofler, Pinqi: an end-to-end physics-informed approach to learned quantitative MRI reconstruction, IEEE Trans. Comput. Imaging 10 (2024) 628–639.
[163] C. H. McCollough, A. C. Bartley, R. E. Carter, B. Chen, T. A. Drees, P. Edwards, D. R. Holmes, A. E. Huang, F. Khan, S. Leng, K. L. McMillan, G. J. Michalak, K. M. Nunez, L. Yu, J. G. Fletcher, Low-dose CT for the detection and classification of metastatic liver lesions: Results of the 2016 low dose CT grand challenge, Med. Phys. 44 (2017) e339–e352.
[164] K. Clark, B. Vendt, K. Smith, J. Freymann, J. Kirby, P. Koppel, S. Moore, S. Phillips, D. Maffitt, M. Pringle, L. Tarbox, F. Prior, The cancer imaging archive (TCIA): Maintaining and operating a public information repository, J. Digit. Imaging 26 (2013) 1045–1057.
[165] A. Zwanenburg, M. Vallières, M. A. Abdalah, H. J. W. L. Aerts, V. Andrearczyk, A. Apte, et al., The image biomarker standardization initiative: Standardized quantitative radiomics for high-throughput image-based phenotyping, Radiology 295 (2020) 328–338.
[166] Y. Fu, Y. Lei, T. Wang, W. J. Curran, T. Liu, X. Yang, Deep learning in medical image registration: A review, Phys. Med. Biol. 65 (2020) 20TR01.
[167] J. Zou, B. Gao, Y. Song, J. Qin, A review of deep learning-based deformable medical image registration, Front. Oncol. 12 (2022) 1047215.
[168] A. Sotiras, C. Davatzikos, N. Paragios, Deformable medical image registration: A survey, IEEE Trans. Med. Imaging 32 (2013) 1153–1190.
[169] A. Bharatha, M. Hirose, N. Hata, S. K. Warfield, M. Ferrant, K. H. Zou, E. Suarez-Santana, J. Ruiz-Alzola, A. D'Amico, R. A. Cormack, R. Kikinis, F. A. Jolesz, C. M. C. Tempany, Evaluation of three-dimensional finite element-based deformable registration of pre- and intraoperative prostate imaging, Med. Phys. 28 (2001) 2551–2560.
[170] Z. Min, Z. M. C. Baum, S. U. Saeed, M. Emberton, D. C. Barratt, Z. A. Taylor, Y. Hu, Non-rigid medical image registration using physics-informed neural networks, in: Information Processing in Medical Imaging, Springer, 2023, pp. 601–613. doi:10.1007/978-3-031-34048-2_46.
[171] P. A. López, et al., WarpPINN: Cine-MR image registration with physics-informed neural networks, Med. Image Anal. 89 (2023) 102925.
[172] A. Amiri-Hezaveh, S. Tan, Q. Deng, D. Umulis, L. Cunniff, J. Weickenmeier, A. Buganza Tepole, A physics-informed deep learning deformable medical image registration method based on neural ODEs, Int. J. Comput. Vis. 133 (2025) 6374–6399.
[173] Y. Wu, T. Jiahao, J. Wang, P. A. Yushkevich, M. A. Hsieh, J. C. Gee, NODEO: A neural ordinary differential equation based optimization framework for deformable image registration, in: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 2022, pp. 20804–20813.
[174] R. Castillo, E. Castillo, R. Guerra, V. E. Johnson, T. McPhail, A. K. Garg, T. Guerrero, A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets, Phys. Med. Biol. 54 (2009) 1849–1870.
[175] E. Castillo, R. Castillo, J. Martinez, M. Shenoy, T. Guerrero, Four-dimensional deformable image registration using trajectory modeling, Phys. Med. Biol. 55 (2010) 305–327.
[176] B. D. De Vos, F. F. Berendsen, M. A. Viergever, H. Sokooti, M. Staring, I. Isgum, A deep learning framework for unsupervised affine and deformable image registration, Med. Image Anal. 52 (2019) 128–143.
[177] B. Jian, M. F. Azampour, F. De Benetti, J. Oberreuter, C. Bukas, A. S. Gersing, S. C. Foreman, A.-S. Dietrich, J. Rischewski, J. S. Kirschke, et al., Weakly-supervised biomechanically-constrained ct/MRI registration of the spine, in: International Conference on Medical Image Computing and Computer-Assisted Intervention, Springer, 2022, pp. 227–236.
[178] J. Boysen, H. Uzunova, H. Handels, J. Ehrhardt, Biophysics-enhanced neural representations for patient-specific respiratory motion modeling, arXiv preprint arXiv:2603.22123 (2026).
[179] E. Salari, J. Wang, J. F. Wynne, C.-W. Chang, Y. Wu, X. Yang, Artificial intelligence-based motion tracking in cancer radiotherapy: A review, J. Appl. Clin. Med. Phys. 25 (2024) e14500.
[180] P. Ren, C. Rao, Y. Liu, Z. Ma, Q. Wang, J.-X. Wang, H. Sun, Physr: Physics-informed deep super-resolution for spatiotemporal data, J. Comput. Phys. 492 (2023) 112438.
[181] M. F. Fathi, I. Perez-Raya, A. Baghaie, P. Berg, G. Janiga, A. Arzani, R. M. D'Souza, Super-resolution and denoising of 4d-flow MRI using physics-informed deep neural nets, Comput. Methods Programs Biomed. 197 (2020) 105729.
[182] D. Sainz-DeMena, M. Pérez, J. M. García-Aznar, Exploring the potential of physics-informed neural networks to extract vascularization data from dce-MRI in the presence of diffusion, Med. Eng. Phys. 123 (2024) 104092.
[183] R. R. Savjani, M. Lauria, S. Bose, J. Deng, Y. Yuan, V. Andrearczyk, Automated tumor segmentation in radiotherapy, Semin. Radiat. Oncol. 32 (2022) 319–329.
[184] D. A. Hormuth, A. M. Jarrett, E. A. B. F. Lima, M. T. McKenna, D. T. Fuentes, T. E. Yankeelov, Mechanism-based modeling of tumor growth and treatment response constrained by multiparametric imaging data, JCO Clin. Cancer Inform. 3 (2019) 1–10.
[185] K. C. L. Wong, R. M. Summers, E. Kebebew, J. Yao, Tumor growth prediction with reaction-diffusion and hyperelastic biomechanical model by physiological data fusion, Med. Image Anal. 25 (2015) 72–85.
[186] D. A. Hormuth, J. A. Weis, S. L. Barnes, M. I. Miga, E. C. Rericha, V. Quaranta, T. E. Yankeelov, A mechanically coupled reaction-diffusion model that incorporates intra-tumoural heterogeneity and mass effect, J. R. Soc. Interface 14 (2017) 20161010.
[187] W. El Afari, M. Ziani, F. Assaoui, Tumor propagation modeling using physics-informed neural networks and variational methods for MRI image segmentation, J. Math. Imaging Vis. 68 (2026) 8.
[188] M. Güzel, Ö. K. Baykan, Physics-informed DynUNet for brain metastasis segmentation, Comput. Methods Programs Biomed. 283 (2026) 109457.
Page 47 of 51
[189] R. Z. Zhang, I. Ezhov, M. Balcerak, A. Zhu, B. Wiestler, B. Menze, J. S. Lowengrub, Personalized predictions of glioblastoma infiltration: Mathematical models, physics-informed neural networks and multimodal scans, Med. Image Anal. 101 (2025) 103423.
[190] M. Sarabian, H. Babaee, K. Laksari, Physics-informed neural networks for brain hemodynamic predictions using medical imaging, IEEE Trans. Med. Imaging 41 (2022) 2285–2303.
[191] R. L. van Herten, A. Chiribiri, M. Breeuwer, M. Veta, C. M. Scannell, Physics-informed neural networks for myocardial perfusion MRI quantification, Med. Image Anal. 78 (2022) 102399.
[192] L. T. Rotkopf, C. H. Ziener, N. von Knebel-Doeberitz, S. D. Wolf, A. Hohmann, W. Wick, M. Bendszus, H.-P. Schlemmer, D. Paech, F. T. Kurz, A physics-informed deep learning framework for dynamic susceptibility contrast perfusion MRI, Med. Phys. 51 (2024) 9031–9040.
[193] P. Fayolle, A. Bône, N. Debs, M. Naudin, P. Bourdon, R. Guillevin, D. Helbert, Physics-informed autoencoder for dsc-MRI perfusion post-processing: application to glioma grading, in: 2025 IEEE 22nd International Symposium on Biomedical Imaging (ISBI), IEEE, 2025, pp. 1–5.
[194] I. Perez-Raya, S. Kandlikar, Thermal modeling of patient-specific breast cancer with physics-based artificial intelligence, ASME J. Heat Mass Transf. 145 (2023) 031201.
[195] H. H. Pennes, Analysis of tissue and arterial blood temperatures in the resting human forearm, J. Appl. Physiol. 1 (1948) 93–122.
[196] I. Perez-Raya, C. Gutierrez, S. Kandlikar, A transformative approach for breast cancer detection using physics-informed neural network and surface temperature data, ASME J. Heat Mass Transf. 146 (2024) 101201.
[197] O. Mukhmetov, Y. Zhao, A. Mashekova, V. Zarikas, E. Y. K. Ng, N. Aidossov, Physics-informed neural network for fast prediction of temperature distributions in cancerous breasts as a potential efficient portable ai-based diagnostic tool, Comput. Methods Programs Biomed. 242 (2023) 107834.
[198] M. Y. Zhao, O. Mukhmetov, A. Mashekova, E. Y. K. Ng, N. Aidossov, V. Zarikas, A. Midlenko, Application of physics informed neural network for breast cancer detection, in: 2024 9th International Conference on Automation, Control and Robotics Engineering (CACRE), IEEE, 2024, pp. 204–208.
[199] S. Das, S. Laxmi, Adaptive residual refinement in physics-informed neural networks for breast cancer thermal modeling and data-driven partial differential equation discovery, Eng. Appl. Artif. Intell. 173 (2026) 114435.
[200] K. Zhang, Y. Li, J. Zhang, B. Wang, Z. Chen, Physics-informed neural network with adaptive loss balancing for real-time radiotherapy dose prediction and verification, Scientific Reports (2026).
[201] Z. Sun, Y. Yan, Y. Chen, G. Yao, J. Wang, W. Hu, Z. Lu, S. Yan, A physics-informed deep learning model for predicting beam dose distribution of intensity-modulated radiation therapy treatment plans, Phys. Imaging Radiat. Oncol. 34 (2025) 100779.
[202] V. S. Yadav, N. Ranwan, N. Chamakuri, Understanding avascular tumor growth and drug interactions through numerical analysis: A finite element method approach, Comput. Math. Appl. 181 (2025) 55–70.
[203] V. S. Yadav, G. Garai, N. Ranwan, N. Chamakuri, A posteriori error-driven space-time adaptive fem for accurate avascular tumor and drug interaction modeling, Numer. Methods Partial Differ. Equ. 42 (2026) e70085.
[204] B. Chhetri, B. R. Kumar, Cbinn: Cancer biology-informed neural network for unknown parameter estimation and missing physics identification: B. chhetri et al., Bulletin of Mathematical Biology 88 (2026) 130.
[205] D. Camacho-Gomez, C. Borau, J. M. Garcia-Aznar, M. J. Gomez-Benito, M. Girolami, M. A. Perez, Physics-informed machine learning digital twin for reconstructing prostate cancer tumor growth via psa tests, npj Digit. Med. 8 (2025) 485.
[206] B. Yaman, S. A. H. Hosseini, S. Moeller, J. Ellermann, K. Uğurbil, M. Akçakaya, Self-supervised learning of physics-guided reconstruction neural networks without fully sampled reference data, Magn. Reson. Med. 84 (2020) 3172–3191.
[207] Y. L. Chan, A. C. Chung, Uncertainty-guided physics-informed image registration for brain tumor MRI with missing correspondences, in: 2026 IEEE 23rd International Symposium on Biomedical Imaging (ISBI), IEEE, 2026, pp. 1–5.
[208] W. Peng, L. Feng, G. Zhao, F. Liu, Learning optimal k-space acquisition and reconstruction using physics-informed neural networks, in: Proceedings of the IEEE/CVF conference on computer vision and pattern recognition, 2022, pp. 20794–20803.
[209] D. Schote, L. Winter, C. Kolbitsch, G. Rose, O. Speck, A. Kofler, Joint and image reconstruction in low-field MRI by physics-informed deep learning, IEEE Trans. Biomed. Eng. 71 (2024) 2842–2853.
[210] S. Fujita, D. Nickel, W.-C. Lo, B. Clifford, S. Cauley, S. Buathong, A. Hajati, F. L. Chiang, J. Conklin, S. Y. Huang, Physics-informed deep learning reconstruction for ultrafast clinical 3d fluid-attenuated inversion recovery brain MRI, Radiol. Adv. 2 (2025) umaf016.
[211] A. Kazemi, I. J. Abecassis, A. A. Amini, Pi-gnn: Physics-informed graph neural network for super-resolution of 4d flow MRI, in: 2024 IEEE International Symposium on Biomedical Imaging (ISBI), IEEE, 2024, pp. 1–5.
[212] P. Borges, C. Sudre, T. Varsavsky, D. Thomas, I. Drobnjak, S. Ourselin, M. J. Cardoso, Physics-informed brain MRI segmentation, in: International Workshop on Simulation and Synthesis in Medical Imaging, Springer, 2019, pp. 100–109.
[213] B. Kang, Pmrnet: Physics-informed multi-scale refinement network for medical image segmentation, in: Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 2026, pp. 15659–15668.
[214] A. J. G. Inda, S. Y. Huang, N. İmamoglu, R. Qin, T. Yang, T. Chen, Z. Yuan, W. Yu, Physics informed neural networks (PINN) for low snr magnetic resonance electrical properties tomography (mrept), Diagnostics 12 (2022) 2627.
[215] M. Balcerak, T. Amiranashvili, A. Wagner, J. Weidner, P. Karnakov, J. C. Paetzold, I. Ezhov, P. Koumoutsakos, B. Wiestler, B. Menze, Physics-regularized multi-modal image assimilation for brain tumor localization, Adv. Neural Inf. Process. Syst. 37 (2024) 41909–41933.
[216] M. Balcerak, J. Weidner, P. Karnakov, I. Ezhov, S. Litvinov, P. Koumoutsakos, T. Amiranashvili, R. Z. Zhang, J. S. Lowengrub, I. Yakushev, et al., Individualizing glioma radiotherapy planning by optimization of a data and physics-informed discrete loss, Nat. Commun. 16 (2025) 5982.
[217] S. Achlatis, E. Gavves, J.-J. Sonke, Physics-guided radiotherapy treatment planning with deep learning, arXiv preprint arXiv:2506.19880 (2025).
[218] L. Hellwege, J. C. Engster, M. Schaar, T. M. Buzug, M. Stille, Unsupervised physics-informed deep learning for dual-energy ct material decomposition, arXiv preprint arXiv:2604.25356 (2026).
Page 48 of 51
[219] M. G. Poirot, R. H. Bergmans, B. R. Thomson, F. C. Jolink, S. J. Moum, R. G. Gonzalez, M. H. Lev, C. O. Tan, R. Gupta, Physics-informed deep learning for dual-energy computed tomography image processing, Sci. Rep. 9 (2019) 17709.
[220] K. P. Pruessmann, M. Weiger, M. B. Scheidegger, P. Boesiger, SENSE: Sensitivity encoding for fast MRI, Magnetic Resonance in Medicine 42 (1999) 952–962.
[221] M. Safari, S. Wang, Z. Eidex, R. L. Qiu, C.-W. Chang, D. S. Yu, X. Yang, A physics-informed deep learning model for MRI brain motion correction, Med. Phys. 52 (2025) e70197.
[222] S. Ahmed, J. Feng, A. Mehmood, M. U. Ali, M. Yaqub, M. A. Manan, A. Raheem, PINN-dadif: Physics-informed deep adaptive diffusion network for robust and efficient MRI reconstruction, Digit. Signal Process. 160 (2025) 105085.
[223] T. Weiss, O. Senouf, S. Vedula, O. Michailovich, M. Zibulevsky, A. Bronstein, Pilot: Physics-informed learned optimized trajectories for accelerated MRI, arXiv preprint arXiv:1909.05773 (2019).
[224] L. Jacobs, S. Mandija, H. Liu, C. A. van den Berg, A. Sbrizzi, M. Maspero, Generalizable synthetic MRI with physics-informed convolutional networks, Med. Phys. 51 (2024) 3348–3359.
[225] P. S. Tofts, G. Brix, D. L. Buckley, J. L. Evelhoch, E. Henderson, M. V. Knopp, H. B. W. Larsson, T.-Y. Lee, N. A. Mayr, G. J. M. Parker, R. E. Port, J. Taylor, R. M. Weisskoff, Estimating kinetic parameters from dynamic contrast-enhanced T1-weighted MRI of a diffusible tracer: Standardized quantities and symbols, Journal of Magnetic Resonance Imaging 10 (1999) 223–232.
[226] L. Østergaard, R. M. Weisskoff, D. A. Chesler, C. Gyldensted, B. R. Rosen, High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysis, Magnetic Resonance in Medicine 36 (1996) 715–725.
[227] M. Asaduddin, E. Y. Kim, S.-H. Park, Spinned: Simulation-based physics-informed neural network for deconvolution of dynamic susceptibility contrast MRI perfusion data, Magn. Reson. Med. 92 (2024) 1205–1218.
[228] J. Kang, E. C. Jung, H. J. Koo, D. H. Yang, H. Ha, Flow-rate-constrained physics-informed neural networks for flow field error correction in four-dimensional flow magnetic resonance imaging, IEEE Trans. Med. Imaging (2025).
[229] U. Katscher, T. Voigt, C. Findeklee, P. Vernickel, K. Nehrke, O. Dössel, Determination of electric conductivity and local SAR via B1 mapping, IEEE Transactions on Medical Imaging 28 (2009) 1365–1374.
[230] G. Ruan, Z. Wang, C. Liu, L. Xia, H. Wang, L. Qi, W. Chen, Magnetic resonance electrical properties tomography based on modified physics-informed neural network and multiconstraints, IEEE Trans. Med. Imaging 43 (2024) 3263–3278.
[231] B. Zapf, J. Haubner, M. Kuchta, G. Ringstad, P. K. Eide, K.-A. Mardal, Investigating molecular transport in the human brain from MRI with physics-informed neural networks, Sci. Rep. 12 (2022) 15475.
[232] L. A. Shepp, Y. Vardi, Maximum likelihood reconstruction for emission tomography, IEEE Transactions on Medical Imaging 1 (1982) 113–122.
[233] K. Gong, J. Guan, K. Kim, X. Zhang, J. Yang, Y. Seo, G. El Fakhri, J. Qi, Q. Li, Iterative PET image reconstruction using convolutional neural network representation, IEEE Transactions on Medical Imaging 38 (2019) 675–685.
[234] A. Mehranian, A. J. Reader, Model-based deep learning PET image reconstruction using forward–backward splitting expectation–maximization, IEEE Transactions on Radiation and Plasma Medical Sciences 5 (2021) 54–64.
[235] C. S. Levin, E. J. Hoffman, Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution, Physics in Medicine and Biology 44 (1999) 781–799.
[236] N. Encina-Baranda, R. J. Paneque-Yunta, J. Lopez-Rodriguez, E. C. Pratt, T. N. Nguyen, J. Grimm, A. Lopez-Montes, J. L. Herraiz, A tissue-informed deep learning-based method for positron range correction in preclinical Ga pet imaging, EJNMMI Physics 13 (2026) 66.
[237] L. Sokoloff, M. Reivich, C. Kennedy, M. H. Des Rosiers, C. S. Patlak, K. D. Pettigrew, O. Sakurada, M. Shinohara, The [14C]deoxyglucose method for the measurement of local cerebral glucose utilization: theory, procedure, and normal values in the conscious and anesthetized albino rat, Journal of Neurochemistry 28 (1977) 897–916.
[238] W. Y. T. Zar, M. R. Kim, A. Ghose, S. Adeleke, M. Gupta, P. S. Choudhary, A. Shankar, S. Mohapatra, S. Boussios, A. Maniam, The current landscape of artificial intelligence in positron emission tomography (PET) imaging across the cancer continuum, J. Clin. Med. 15 (2026) 2446.
[239] T. L. Szabo, Time domain wave equations for lossy media obeying a frequency power law, The Journal of the Acoustical Society of America 96 (1994) 491–500.
[240] B. E. Treeby, B. T. Cox, k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields, Journal of Biomedical Optics 15 (2010) 021314.
[241] A. Tarantola, Inversion of seismic reflection data in the acoustic approximation, Geophysics 49 (1984) 1259–1266.
[242] J. Virieux, S. Operto, An overview of full-waveform inversion in exploration geophysics, Geophysics 74 (2009) WCC1–WCC26.
[243] R.-E. Plessix, A review of the adjoint-state method for computing the gradient of a functional with geophysical applications, Geophysical Journal International 167 (2006) 495–503.
[244] C. Errico, J. Pierre, S. Pezet, Y. Desailly, Z. Lenkei, O. Couture, M. Tanter, Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging, Nature 527 (2015) 499–502.
[245] M. Liang, J. Liu, H. Wang, S. An, C. Chen, H. Chu, M. Zhu, X. Su, P. Liang, Y. Zong, et al., Ultrasound super-resolved hemodynamic estimation in microvessel using physics-informed neural networks and data assimilation, Comput. Methods Programs Biomed. (2025) 109136.
[246] L. Lu, X. Meng, Z. Mao, G. E. Karniadakis, DeepXDE: A deep learning library for solving differential equations, SIAM Review 63 (2021) 208–228.
[247] C. Wu, M. Zhu, Q. Tan, Y. Kartha, L. Lu, A comprehensive study of non-adaptive and residual-based adaptive sampling for physics-informed neural networks, Computer Methods in Applied Mechanics and Engineering 403 (2023) 115671.
[248] N. Moriakov, K. Michielsen, J. Adler, R. Mann, I. Sechopoulos, J. Teuwen, Deep learning framework for digital breast tomosynthesis reconstruction, in: Medical Imaging 2019: Physics of Medical Imaging, volume 10948, SPIE, 2019, p. 1094804. doi:10.1117/12.2512912.
Page 49 of 51
[249] J. Teuwen, N. Moriakov, C. Fedon, M. Caballo, I. Reiser, P. Bakic, E. García, O. Diaz, K. Michielsen, I. Sechopoulos, Deep learning reconstruction of digital breast tomosynthesis images for accurate breast density and patient-specific radiation dose estimation, Med. Image Anal. 71 (2021) 102061.
[250] Z. Yu, M. A. Rahman, T. Schindler, R. Laforest, A. K. Jha, A physics and learning-based transmission-less attenuation compensation method for spect, in: Medical Imaging 2021: Physics of Medical Imaging, volume 11595, SPIE, 2021, p. 1159512. doi:10.1117/12.2582350.
[251] X. Chen, B. Zhou, H. Xie, L. Shi, H. Liu, W. Holler, M. Lin, Y.-H. Liu, E. J. Miller, A. J. Sinusas, C. Liu, Direct and indirect strategies of deep-learning-based attenuation correction for general purpose and dedicated cardiac spect, Eur. J. Nucl. Med. Mol. Imaging 49 (2022) 3046–3060.
[252] P. Sibolt, L. M. Andersson, L. Calmels, D. Sjöström, U. Bjelkengren, P. Geertsen, C. F. Behrens, Clinical implementation of artificial intelligence-driven cone-beam computed tomography-guided online adaptive radiotherapy in the pelvic region, Phys. Imaging Radiat. Oncol. 17 (2021) 1–7.
[253] M. Xu, L. V. Wang, Photoacoustic imaging in biomedicine, Review of Scientific Instruments 77 (2006) 041101.
[254] S. Paul, S. A. Lee, S. Zhao, Y.-S. Chen, Model-informed deep-learning photoacoustic reconstruction for low-element linear array, Photoacoustics 44 (2025) 100732.
[255] B. Cox, J. G. Laufer, S. R. Arridge, P. C. Beard, Quantitative spectroscopic photoacoustic imaging: a review, Journal of Biomedical Optics 17 (2012) 061202.
[256] A. Saba, C. Gigli, A. B. Ayoub, D. Psaltis, Physics-informed neural networks for diffraction tomography, Adv. Photonics 4 (2022) 066001.
[257] M. Macenko, M. Niethammer, J. S. Marron, D. Borland, J. T. Woosley, X. Guan, C. Schmitt, N. E. Thomas, A method for normalizing histology slides for quantitative analysis, in: Proceedings of the IEEE International Symposium on Biomedical Imaging: From Nano to Macro, 2009, pp. 1107–1110.
[258] B. H. Menze, A. Jakab, S. Bauer, J. Kalpathy-Cramer, K. Farahani, J. Kirby, et al., The multimodal brain tumor image segmentation benchmark (BRATS), IEEE Trans. Med. Imaging 34 (2015) 1993–2024.
[259] A. W. Moawad, A. Janas, U. Baid, D. Ramakrishnan, R. Saluja, N. Ashraf, N. Maleki, L. Jekel, N. Yordanov, P. Fehringer, et al., The brain tumor segmentation-metastases (brats-mets) challenge 2023: Brain metastasis segmentation on pre-treatment mri, ArXiv (2024) arXiv-2306.
[260] E. Grøvik, D. Yi, M. Iv, E. Tong, D. Rubin, G. Zaharchuk, Deep learning enables automatic detection and segmentation of brain metastases on multisquence mri, Journal of Magnetic Resonance Imaging 51 (2020) 175–182.
[261] S. G. Armato III, G. McLennan, L. Bidaut, M. F. McNitt-Gray, C. R. Meyer, A. P. Reeves, B. Zhao, D. R. Aberle, C. I. Henschke, E. A. Hoffman, et al., The lung image database consortium (lidc) and image database resource initiative (idri): a completed reference database of lung nodules on ct scans, Medical physics 38 (2011) 915–931.
[262] N. Heller, F. Isensee, K. H. Maier-Hein, X. Hou, C. Xie, F. Li, Y. Nan, G. Mu, Z. Lin, M. Han, et al., The state of the art in kidney and kidney tumor segmentation in contrast-enhanced ct imaging: Results of the kits19 challenge, Medical image analysis 67 (2021) 101821.
[263] G. Litjens, R. Toth, W. Van De Ven, C. Hoeks, S. Kerkstra, B. Van Ginneken, G. Vincent, G. Guillard, N. Birbeck, J. Zhang, et al., Evaluation of prostate segmentation algorithms for mri: the promise12 challenge, Medical image analysis 18 (2014) 359–373.
[264] T. E. Yankeelov, G. S. Karczmar, R. G. Abramson, Data from qin-breast-02, 2019. doi:10.7937/TCIA.2019.4cfm06rr.
[265] S. C. Partridge, Z. Zhang, D. C. Newitt, J. E. Gibbs, T. L. Chenevert, M. A. Rosen, P. J. Bolan, H. S. Marques, J. Romanoff, L. Cimino, et al., Diffusion-weighted mri findings predict pathologic response in neoadjuvant treatment of breast cancer: the acrin 6698 multicenter trial, Radiology 289 (2018) 618–627.
[266] W. Li, D. C. Newitt, J. Gibbs, L. J. Wilmes, E. F. Jones, V. A. Arasu, F. Strand, N. Onishi, A. A.-T. Nguyen, J. Kornak, et al., Predicting breast cancer response to neoadjuvant treatment using multi-feature mri: results from the i-spy 2 trial, NPJ breast cancer 6 (2020) 63.
[267] A. Babier, B. Zhang, R. Mahmood, K. L. Moore, T. G. Purdie, A. L. McNiven, T. C. Chan, Openkbp: the open-access knowledge-based planning grand challenge and dataset, Medical Physics 48 (2021) 5549–5561.
[268] L. Sun, K. Bjegovic, L. Rodriguez-Gonzalez, Y. Xu, Y. Yan, G. Gonzalez, L. Whitmore, L. Connell, Y. Lang, P. Pandey, et al., A physics-informed neural network for in vivo dosimetry using quantitative radiacoustic imaging, Research Square (2026) rs-3.
[269] H. Eichhorn, V. Spieker, K. Hammernik, E. Saks, L. Felsner, K. Weiss, C. Preibisch, J. A. Schnabel, Motion-robust t 2t_2^ quantification from low-resolution gradient echo brain mri with physics-informed deep learning, Magnetic Resonance in Medicine 95 (2026) 346–362.
[270] C. Qian, H. Zhang, Y. Gao, M. Han, Z. Wang, D. Ruan, Y. Shen, Y. Wu, Y. Zhou, C. Wang, et al., Physics-informed deep diffusion mri reconstruction with synthetic data: Break training data bottleneck in artificial intelligence, arXiv preprint arXiv:2210.11388 (2022).
[271] Z. Wang, X. Yu, C. Wang, W. Chen, J. Wang, Y.-H. Chu, H. Sun, R. Li, P. Li, F. Yang, et al., One for multiple: Physics-informed synthetic data boosts generalizable deep learning for fast mri reconstruction, Medical Image Analysis 103 (2025) 103616.
[272] Y. Fan, Y. Liu, A. Aji, T. Feng, D. Ta, Pit-net: Physics-informed transformer with differentiable diffusion constraints for quantitative photoacoustic tomography of deep tissues, Photoacoustics (2026) 100846.
[273] D. Khurana, R. Kaur, R. K. Roul, S. Batra, Explainable artificial intelligence in cancer care: A domain-wise review of adoption, challenges and opportunities, Expert Syst. 43 (2026) e70238.
[274] S. Chakraborty, Transfer learning based multi-fidelity physics informed deep neural network, J. Comput. Phys. 426 (2021) 109942.
[275] K. Prantikos, S. Chatzidakis, L. H. Tsoukalas, A. Heifetz, Physics-informed neural network with transfer learning (tl-PINN) based on domain similarity measure for prediction of nuclear reactor transients, Sci. Rep. 13 (2023) 16840.
[276] T. Kapoor, H. Wang, A. Núñez, R. Dollevoet, Transfer learning for improved generalizability in causal physics-informed neural networks for beam simulations, Eng. Appl. Artif. Intell. 133 (2024) 108085.
[277] L. Liu, J. Luo, Y. Heng, Fast solution of 3d transport processes using a physics-informed neural network with embedded transfer learning, Sep. Purif. Technol. 363 (2025) 132012.
[278] Z. Yang, W. Xia, Z. Lu, Y. Chen, X. Li, Y. Zhang, Hypernetwork-based physics-driven personalized federated learning for ct imaging, IEEE Trans. Neural Netw. Learn. Syst. 36 (2023) 3136–3150.
Page 50 of 51
[279] Y. Li, S. He, Y. Li, Y. Shi, Z. Zeng, Federated multiagent deep reinforcement learning approach via physics-informed reward for multimicrogrid energy management, IEEE Trans. Neural Netw. Learn. Syst. 35 (2023) 5902–5914.
[280] H. Zhang, L. Liu, K. Weng, L. Lu, Federated scientific machine learning for approximating functions and solving differential equations with data heterogeneity, IEEE Trans. Neural Netw. Learn. Syst. (2025).
[281] L. Fan, B. Chen, X. Hu, W. Niu, Pifl: Physics-informed federated learning for progressive degradation estimation in energy storage devices, Adv. Eng. Inform. 69 (2026) 103908.
[282] J. Chen, J. Wang, Y. Jiang, Z. Wang, F. Zhang, Y. Yang, A novel physics-informed federated learning framework for robust bearing fault diagnosis, ACM Trans. Auton. Adapt. Syst. (2026).
[283] S. Yang, H. Kim, Y. Hong, K. Yee, R. Maulik, N. Kang, Data-driven physics-informed neural networks: A digital twin perspective, Comput. Methods Appl. Mech. Eng. 428 (2024) 117075.
[284] R. Tang, L. Wu, Z. Wang, L. Zhu, A. Sun, Q. Ru, B. Ju, Physics-informed neural networks for real-time updating and synchronisation in digital twins: A focused review, Digit. Twin Appl. 3 (2026) e70042.
[285] S. Shen, W. Qi, X. Liu, J. Zeng, S. Li, G. Peng, P. Li, J. Wang, X. Lu, S. Cao, Mapping the landscape of ai-driven digital twins in medical diagnosis: A scoping review on core technologies, applications, and implementation barriers, Artif. Intell. Med. (2026) 103474.
[286] K. Kuang, F. Dean, J. B. Jedlicki, D. Ouyang, A. Philippakis, D. Sontag, A. Alaa, Med-real2sim: Non-invasive medical digital twins using physics-informed self-supervised learning, Adv. Neural Inf. Process. Syst. 37 (2024) 5757–5788.
[287] U. M. Nabila, P. Seurin, L. Lin, M. I. Radaideh, Physics-informed digital twin development of thermal energy distribution systems with active learning, Appl. Energy 416 (2026) 127903.
[288] A. Karkadakattil, A physics-stabilized self-updating digital twin framework using physics-informed neural networks for thermal field prediction, Appl. Comput. Syst. 31 (2026) 30–40.
[289] D. Osman, K. Sel, E. Spatz, R. Jafari, Cardiovascular digital twins using a windkessel physics informed neural network, npj Digit. Med. (2026).
[290] Y. Kang, J. Yang, Y. Zhou, Y. Yuan, S. Qin, Y. Li, Y. Yang, A hard-constrained physics-informed neural network for localized digital twin modeling, Energy 347 (2026) 140379.
[291] R. Sapkota, K. I. Roumeliotis, M. Karkee, Ai agents vs. agentic ai: A conceptual taxonomy, applications and challenges, Inf. Fusion (2025) 103599.
[292] Q. Jiang, G. Karniadakis, Agenticsciml: Collaborative multi-agent systems for emergent discovery in scientific machine learning, npj Artif. Intell. (2026).
[293] J. D. Toscano, D. T. Chen, G. E. Karniadakis, Athena: Agentic team for hierarchical evolutionary numerical algorithms, arXiv preprint arXiv:2512.03476 (2025).
[294] L. Kong, H. Ma, Uncertainty-aware prediction of lung tumor growth from sparse longitudinal ct data via bayesian physics-informed neural networks, arXiv preprint arXiv:2605.13560 (2026).
[295] A. Venkataramanan, S. K. Vemuri, A. A. C. Valapil, J. Denzler, Uncertainty-aware physics-informed neural networks for robust cars-to-raman signal reconstruction, arXiv preprint arXiv:2511.13185 (2025).
[296] S. Thakur, M. Roper, Y. Zhou, D. Y. Isaev, R. A. Bafghi, B. K. Nallamothu, C. A. Figueroa, S. Paruchuri, S. Burger, C. Collet, et al., Punch: Physics-informed uncertainty-aware network for coronary hemodynamics, arXiv preprint arXiv:2601.17192 (2026).
[297] J. Lee, M. Choi, H. Jang, Y. H. Jeon, H. Eum, J. Jang, C.-H. Sohn, K. S. Choi, Evidential perfusion physics-informed neural networks with residual uncertainty quantification, arXiv preprint arXiv:2603.09359 (2026).
[298] C. He, H. Shi, X. Liu, J. Li, Interpretable physics-informed domain adaptation paradigm for cross-machine transfer diagnosis, Knowl. Based Syst. 288 (2024) 111499.
[299] B. Liu, C. Yan, C. He, M. Lv, J. Wei, L. Wu, An interpretable physics-informed subdomain moment-enhanced adaptation network for unsupervised transfer fault diagnosis of rolling bearing, Adv. Eng. Inform. 67 (2025) 103491.
[300] A. Qadir, S. Arif, P. Valsalan, O. Khan, Physics-guided deep learning for interpretable biomedical image reconstruction and pattern recognition in diagnostic frameworks, Bioengineering 13 (2026) 457.
[301] S. S. Menon, A. D. Jagtap, Anant-net: Breaking the curse of dimensionality with scalable and interpretable neural surrogate for high-dimensional pdes, Computer Methods in Applied Mechanics and Engineering 447 (2025) 118403.
[302] A. Stanzione, R. Cuocolo, L. Ugga, F. Verde, V. Romeo, A. Brunetti, S. Maurea, Oncologic imaging and radiomics: a walkthrough review of methodological challenges, Cancers (Basel) 14 (2022) 4871.
Page 51 of 51