arXiv:2610.18746cs.HCOct 2026

Manuscript Offprint

arXiv:2610.18746

Bio-Inspired Electrotactile Feedback: A Framework and Impacts of Multimodal Cues

Melika Emami, Amirhossein Bayat, Rahim Tafazolli, Atta Quddus

Melika Emami§ ib, Amirhossein Bayat§ ib, Rahim Tafazolli ib, Senior Member, IEEE, and Atta Quddus ib

Abstract—Electrotactile stimulation, as a haptic feedback method, often struggles to evoke high-quality natural sensations. Consequently, despite its practical advantages, it is generally less preferred in human-machine systems than mechanical approaches. In this paper, we propose a bio-inspired stimulation framework that generates signals modelled on afferent neural activity derived from a touch model. By producing more biologically plausible spiking patterns, the proposed approach aims to enhance the realism of perceived tactile sensations. To evaluate these stimulation patterns in a realistic task context and to quantify the influence of visual and movement cues, we conducted a series of subjective experiments under three conditions. The results indicate that bio-inspired modulation was effective: in particular, bio-inspired co-modulation of amplitude and frequency achieved a favourable pressure-irritation tradeoff, increasing the probability of perceiving pressure while maintaining low irritation (pressure: 0.78; irritation: 0.24) relative to the other patterns. Visual cues and hand movement further improved feedback quality by significantly increasing the probability of reporting pressure (p<0.001) without a corresponding increase in irritation, and by increasing mean naturalness ratings. Overall, these findings demonstrate the potential of bio-inspired electrotactile patterns to improve haptic feedback quality, and highlight the importance of evaluating such methods under realistic, multimodal interaction scenarios.

Index Terms—Haptic Feedback, electrotactile, quality of sensation, bio-inspired stimulation, human-machine systems.

I. INTRODUCTION

HAPTIC feedback enables the perception of touch in human-machine systems such as virtual reality (VR), teleoperation, remote surgery, social interaction, and prosthetics [1], [2]. By conveying tactile sensations, haptics can enhance realism, immersion, and precision in these experiences.

Haptic technologies are commonly categorised as mechanical or electrical [3]. Mechanical approaches (e.g., piezoelectric and vibrotactile actuators) physically interact with the skin or joints to generate sensations such as touch, pressure, or grasping [4]. While often capable of natural sensations, they can be bulky, complex, power-hungry, and limited in spatial resolution. Electrotactile feedback instead stimulates peripheral nerves using low-current pulses delivered through skin electrodes [5], [6]. It is lightweight, compact, flexible, energy efficient and can support high-resolution stimulation [7]; however, it frequently evokes artificial or “electrical” percepts that reduce perceived realism [8].

Therefore, improving the quality of the electrotactile sensation is critical. Prior work has optimised parameters such as frequency in tonic stimulation to shape percepts and reduce undesirable sensations (e.g., tingling) [9]–[11]. Beyond single-parameter tuning, spatio-temporal patterns for signal modulation or electrode activation have been proposed to better reflect the dynamics of real touch [12]. For example, linear amplitude modulation has been used to convey softness by mapping stimulus intensity to virtual interaction forces [13], and modulating the effective contact area via spatio-temporal stimulation has also been shown to influence softness perception [14]. Although such approaches exploit the physics of interaction, they may still fail to reproduce the underlying neural responses that accompany natural touch.

A complementary direction is to approximate biological neural coding of touch using bio-inspired modulation strategies [15]. In prosthetics, biomimetic sensory feedback has produced more intuitive and lifelike sensations than conventional approaches [15]–[18]. However, existing frameworks raise two key issues for non-prosthetic contexts. First, most evidence comes from prosthetic applications, where stimulation site, modality, and objectives differ from VR and teleoperation; consequently, the appropriate bio-inspired design may not directly transfer. Second, evaluation methods should match application goals: prosthetics prioritise sensory restoration and functional integration, whereas VR and teleoperation often emphasise immersion, naturalness, and perceptual precision.

A further limitation is ecological validity. To stabilise skin impedance and electrode contact, many electrotactile studies require a stationary hand [19]. Although this improves reliability, it does not reflect dynamic scenarios in which movement is integral, such as VR interactions. Task-based studies that include hand gestures often focus on task performance rather than perceived sensation quality [20].

In this study, we pursue three objectives: (1) propose a framework for generating bio-inspired electrotactile stimulation patterns to improve perceived sensation quality; (2) evaluate these patterns under more realistic, application-relevant conditions (VR-like interaction); and (3) quantify how visual and movement cues shape the haptic experience.

Our framework uses TouchSim, a computational touch model that simulates afferent activity in response to skin deformation [21]. By aggregating model outputs (e.g., firing rates), we map biologically derived signals to electrotactile parameters, including amplitude and frequency. We then conducted a three-session subjective study: (i) no additional cues, (ii) synchronised video of a virtual hand pressing a button (visual cues), and (iii) participants mimicking the button press in mid-air while viewing the same video (visual + movement cues). Sensation quality was assessed via reported sensation

$Equal contribution.

All authors are with the Institute for Communication Systems (ICS), Home of 5G & 6G Innovation Centres, University of Surrey, UK.

This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

types (pressure and irritation) and perceived naturalness.

Overall, the results show that bio-inspired patterns can enhance electrotactile sensation quality by increasing pressure while keeping irritation comparatively low, with the most favourable balance achieved by hybrid co-modulation of amplitude and frequency derived from the proposed framework. Moreover, synchronised video and movement cues further improved perceived quality for most patterns, with particularly strong gains for bio-inspired signals, suggesting that combining bio-inspired stimulation with multimodal cues yields the most favourable outcomes.

The remainder of this paper is organised as follows. Section II describes the proposed framework. Section III details the stimulation signals, device, experimental procedure, and participants. Section IV reports the analysis and results, and Section V discusses key findings, limitations, and future directions. Finally, Section VI concludes the paper.

References (36)