arXiv:2608.26901physics.med-phAug 2026

Manuscript Offprint

arXiv:2608.26901

Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning

Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty, Indranil Mallick

Abstract

Automating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage ( D95D_{95}), though statistical analysis revealed a marginal reduction in target homogeneity ( p<0.001p < 0.001) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing ( p<0.001p < 0.001). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in 11 out of 14 Moderate Hypofraction Arm plans and 9 out of 12 Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.

1 Introduction

The standard of care for high-risk localized prostate cancer is Intensity-Modulated Radiation Therapy (IMRT) [1, 2]. When irradiation of the pelvic nodes is performed, a simultaneous integrated boost (SIB) approach is used. SIB regimens require the simultaneous delivery of an escalated prescription dose to the primary planning target volume (PTV) and a lower dose to the elective pelvic lymph nodes. These plans require complex spatial dose gradients [1]. This multi-target dosimetric objective must be achieved while strictly adhering to mandatory maximum and dose-volume constraints for nearby organs at risk (OARs), specifically the anorectum and bladder, to prevent severe gastrointestinal and genitourinary toxicities [3]. Consequently, manual inverse treatment planning remains a highly iterative, resource-intensive workflow that is heavily dependent on the individual planner's experience. This invariably leads to significant inter-planner variability and sub-optimal operational efficiency in high-volume clinical settings [4].

Recent advancements in deep learning, particularly 3D U-Net architectures, have demonstrated significant potential in automating volumetric dose prediction [5, 6]. To mitigate the resource-intensive nature of manual optimization, recent clinical workflows have successfully leveraged knowledge-based planning (KBP) frameworks to fully automate treatment plan generation across diverse anatomical sites [7]. However, conventional frameworks predominantly approach dose prediction as a standard image-to-image translation task, relying on Mean Squared Error (MSE) or Mean Absolute Error (MAE) as the primary optimization metric [8]. This creates a fundamental disconnect between mathematical optimization and clinical reality. MSE intrinsically minimizes the global average voxel-wise error, meaning it treats a 1 Gy deviation in the geometric center of the target volume with the exact same mathematical weight as a 1 Gy deviation spilling across the boundary into the rectal wall. Clinical plan acceptability, however, is not determined by global volumetric averages; it is strictly governed by localized boundary constraints, absolute maximum dose ceilings, and specific dose-volume histogram (DVH) thresholds. Consequently, MSE-driven models frequently generate

Bhattacharjee et al. (2026)

dose distributions that achieve a low global error but fail clinical evaluation due to point-dose violations in serial OARs or unacceptable cold spots at the target periphery [9]. To bridge the gap between theoretical volumetric approximation and clinical deployability, neural network architectures must move beyond generic pixel-wise loss. They require physics-guided optimization engines capable of spatial awareness, prioritizing critical tissue boundaries, and mimicking the non-linear dosimetric compromises executed by expert human planners.

To overcome the limitations of generic voxel-wise objectives, a treatment planning framework must transition from statistical image translation to mathematically enforced, physics-guided optimization [10]. Achieving true clinical usability dictates that an artificial intelligence must “see” anatomical boundaries rather than merely mapping isolated voxel intensities. This requires explicit spatial awareness of the local anatomy, allowing the network to calculate the exact proximity of high-dose clouds to abutting serial structures [11]. It must understand the fundamental radiation dose absorption principles like the inverse square law which drives these gradients such that absurd dose gradients are not generated. Furthermore, the optimization engine must deploy a multi-objective penalty system that inherently understands the hierarchy of clinical constraints. It must mathematically differentiate between a soft penalty for optional dose spillage into generic healthy tissue and a severe, overriding penalty for a mandatory constraint violation within the rectal wall or bladder [12]. By encoding these strict dosimetric rules directly into the gradient descent space, the network is forced to learn the non-linear spatial compromises required for safe, physician-approvable clinical planning.

In this work, we propose Dose-PlanNet, a physics-guided deep learning framework specifically engineered to generate clinically acceptable IMRT plans for prostate Simultaneous Integrated Boost (SIB) protocols. The novelty of Dose-PlanNet is anchored in three primary methodological contributions. First, we utilize discrete PTV mapping, governed by a Painter's Algorithm, to explicitly inject varying prescription doses directly into the input tensor, definitively resolving SIB dose hierarchies. Second, we equip the network with absolute spatial awareness by integrating Signed Distance Maps (SDMs) for abutting serial organs alongside a Beam's Eye View (BEV) frustum mask; this combination allows the architecture to mathematically distinguish in-beam dose corridors from physically impossible out-of-beam scatter. Finally, we replace standard voxel-wise metrics with a custom, multi-objective physics-guided loss engine. This engine features differentiable Dose-Volume Histogram (DVH) estimations via steep sigmoid approximations, deploying tuned penalties to strictly enforce global dose ceilings, exact V-type OAR constraints, and absolute PTV coverage thresholds. Evaluated on a clinical prostate SIB cohort, Dose-PlanNet successfully generated steep dose gradients to yield physician-approvable dose distributions. The framework achieved good OAR sparing while simultaneously satisfying mandatory PTV coverage constraints for the vast majority of patients, demonstrating robust clinical utility over standard translation-based AI approaches.

References (23)