Manuscript Offprint
arXiv:2610.12702Product Monte Carlo: Expectation Under a Product of Densities
Abstract
Aggregating independently computed sub-sample inferences is a well-known challenge in large-scale Bayesian computation, federated learning, and opinion pooling. The core problem is to approximate a distribution whose density is proportional to a product of individual densities. We propose Product Monte Carlo (PMC), an algorithm for computing arbitrary expectations under a product of densities using only Monte Carlo draws from individual densities. We turn the intractable product expectation into a regression problem by expressing it through a family of computable conditional expectations. Besides the point estimate, our fully Bayesian regression formulation provides coherent uncertainty quantification and principled diagnostics. We establish theoretical guarantees on consistency and characterize convergence rates for the PMC estimator. Across simulated and real-data experiments varying the number, dimensionality, and heterogeneity of the component distributions, PMC achieves higher estimation accuracy, better-calibrated uncertainty coverage, and improved scalability at a lower computational cost than existing methods. In addition, PMC requires no density evaluation, making it applicable to simulation-based inference, as we demonstrate in an application with protein images.
Keywords: distributed learning, Monte Carlo method, product distribution, simulation-based inference, uncertainty quantification
1. Introduction
Many statistical problems involve computing expectations under the product of densities. For illustration, we begin with an example from Bayesian subsampling: the data are conditionally i.i.d. given a parameter and can be partitioned into disjoint subsets . If we denote the prior distribution and the likelihood function , the full posterior distribution of given the data is
The subposterior is the inference based on subset data:
where the prior is scaled to reflect the partition. We can then obtain samples from each subposterior, which often is easier than the full sampling:
University of Texas at Austin, Department of Statistics and Data Sciences
Duke University, Department of Statistical Science
We thank Jinlin Lai for help with our SBI experiment. Code and reproducibility materials are available at https://github.com/PietroCarlotti/product-monte-carlo.
However, even if the subsamples are readily available, computing quantities under the full-data posterior remains nontrivial. The full posterior density is proportional to the product of subposteriors:
To solve this aggregation task, this paper develops Product Monte Carlo (PMC), a framework for estimating expectations under a product density, formally:
Definition 1 (Product Distribution). Let be densities of distributions on , where . The product density is defined as follows:
with an unknown normalizing constant
Throughout this paper, “product” refers to the pointwise product of component densities on , and should not be confused with a product measure on .
As in other Monte Carlo methods, our goal is to compute the expectation of any integrable function , with , under the product density:
In the subsampling example, the components are the subposterior densities, and their product, after normalization, is the full-data posterior. Taking or yields the first or second moment under the full posterior.
Heuristic of PMC. First draw S samples from each component density, independently across components:
PMC aggregates individual samples via a regression to estimate any expectation under the product distribution. See Figure 1 for the workflow.
To build intuition for how PMC works, consider two independent random variables in : , and . Define their scaled sum and difference by
The conditional distribution of C given is exactly the target product distribution:
Intuitively, the product distribution is the slice of the joint distribution along the diagonal of the product space. Figure 2 illustrates a Gaussian example.

Figure 1: PMC aggregates samples from individual components to estimate any expectation under the product distribution. No density evaluation of is needed.
The above identity belongs to a broader family of conditional representations, which we develop in the rest of the paper, where C captures consensus among the component variables and D measures their discrepancy. This lets us express expectations under the product distribution as conditional expectations:
Although the event has zero probability, we can estimate the conditional expectation through regression. PMC develops a general recipe for these representations and their fully Bayesian estimation.
As we will show through theoretical analysis and empirical evaluation in the subsequent sections, the salient features of PMC include the following:
• Distribution-free: Without parametric restrictions, PMC allows arbitrary component densities .
• Evaluation-free: PMC requires only samples from the component distributions, not evaluations of their densities or product. This makes it suitable for simulation-based and likelihood-free inference.
• Scalable: PMC allows parallel sampling across components without coordination and reduces intractable product sampling to regression, which scales better with dimension and sample size.
• Calibrated: Our fully Bayesian formulation in PMC provides coherent uncertainty quantification and credible intervals, accounting for both the Monte Carlo and epistemic errors.
• Diagnosable: PMC turns a computing task into a modeling problem, which incorporates the established Bayesian workflow and supports model diagnostics, checks, and iterative model improvement.
Applications. Beyond its interest as a general problem, computing expectations under products of densities is useful in several practical settings.
As in our motivating example of large-scale inference, partitioning a large dataset and sampling from subposteriors substantially reduces the cost: each subposterior requires a fraction of the likelihood and gradient evaluation cost; subposteriors can be sampled in parallel (Neiswanger et al., 2014; Scott et al., 2016); and amortized methods such as neural posterior estimation (e.g., Papamakarios and Murray, 2016) can make repeated inference inexpensive after training. The remaining task is then to aggregate them into the product. This product form arises naturally under conditional independence, as multiplication combines information sources (Bernardo and Smith, 1994).
In federated learning (e.g., Al-Shedivat et al., 2021; Liu et al., 2024; Jonker et al., 2024) or privacy-sensitive applications, data cannot be centralized for storage and processing. Inference

Figure 2: For and , the product distribution matches the conditional distribution on the diagonal slice.
must use data held locally across different sites, and then multiply individual densities.
Products also arise in ensemble prediction, where product-of-experts and logarithmic pooling combine predictive densities multiplicatively (Genest and Zidek, 1986; Hinton, 2002). An open challenge is then to evaluate the combined predictive distribution.
In many of these applications, individual component densities cannot be evaluated: local densities in privacy settings can leak data information; posterior predictive densities in expert pooling require additional integration; and generative-model-based samplers and simulation-based inference (SBI) methods provide samples without tractable density evaluations.
Parametric approximation. It is natural to approximate each component with a parametric family that keeps the product distribution analytical. Exploiting the fact that the product of Gaussians is itself Gaussian, Huang and Gelman (2005) used Gaussian approximations for large-scale Bayesian computation, Consensus Monte Carlo (Scott et al., 2016) aggregated subposterior draws through precision-weighting, and Carvalho et al. (2023) applied similar approximations to logarithmic pooling. Moving beyond a single Gaussian approximation, Neiswanger et al. (2014) combined kernel-based estimates of the component densities, and Cai et al. (2025) derived an analytic representation for products of Student-t densities using the Feynman parameterization. However, parametric approximations rely on strong assumptions and thus introduce additional bias that persists even with
| Method | Distribution-free | Evaluation-free | UQ |
|---|---|---|---|
| Parametric approx. | ✓ | ||
| Weighting | ✓ | ||
| Fusion | ✓ | ||
| PMC | ✓ | ✓ | ✓ |
Table 1: Comparison of available methods and PMC.
large Monte Carlo samples. In comparison, PMC imposes no parametric assumptions, yet our theory shows that PMC recovers parametric efficiency in the Gaussian case.
Importance weighting. Subposterior draws can be reweighted to approximate the product distribution (Mesquita et al., 2020). Although simple to implement and free of parametric assumptions, importance weighting requires density evaluations and can yield unstable estimates with high or even infinite variance when importance ratios have heavy tails (Vehtari et al., 2024). This issue may be especially pronounced here because the product distribution is typically more concentrated than its component distributions.
Fusion methods. An alternative approach is to construct a sampler targeting the product distribution rather than estimating its expectations directly. To this end, fusion methods, including Monte Carlo Fusion (MCF; Dai et al., 2019), Bayesian Fusion (BF; Dai et al., 2023), and Generalized Bayesian Fusion (GBF; Chan et al., 2023), initialize stochastic processes at subposterior draws, constructed to coalesce at a common endpoint distributed according to the product target. Like PMC, fusion methods do not restrict component densities to specific parametric families. However, simulating the resulting -dimensional stochastic processes times is itself a nontrivial sampling problem, which incurs heavy computational overhead for large , , or . Moreover, fusion methods require evaluating component densities and their derivatives, thus limiting their applicability if they are unavailable or computationally expensive.
Uncertainty quantification. While many existing approaches can return a Monte Carlo error, they typically cannot assess epistemic uncertainty. For example, when component distributions are well-separated, estimating their product expectation is intrinsically hard. PMC is designed to reflect this difficulty through larger posterior uncertainty, whereas other methods yield vanishingly small uncertainty as the Monte Carlo size increases, even for inaccurate estimates.
The remainder of this paper is organized as follows. Section 2 introduces PMC for estimating expectations under products of densities. Section 3 studies its asymptotic consistency and convergence rate. Section 4 evaluates our method empirically on simulated and real scientific data. Section 5 concludes with a discussion of our findings and directions for future work.
2. Proposed method
Setting and notation. Let be arbitrary distributions on . We assume we can draw mutually independent random samples
from individual distributions, but we do not assume we can evaluate the density function. Collectively, we write . Our goal is to compute , the expectation of an arbitrary function under the product distribution.
2.1. Consensus and discrepancy
We generalize our heuristic: the product distribution can be represented as the distribution of a consensus mapping conditional on a discrepancy mapping being zero. We first define these mappings.
Definition 2 (Consensus). A measurable and continuous mapping is a consensus if 1. For identical inputs, returns their common value:
- c is translation-equivariant:
where .
Examples of consensus mappings c include the arithmetic average, the weighted average, and the median. Translation equivariance implies that shifting all components shifts the consensus by the same amount. We impose this natural condition to simplify the analysis.
Definition 3 (Discrepancy). Consider the full discrepancy mapping defined by
Let be continuous and satisfy
-
.
-
Then, is a discrepancy if
Examples of the discrepancy include (i) full discrepancy mapping , and (ii) its norm . By design, implies .
Given , we henceforth write
for the induced consensus and discrepancy variables.
The following theorem formally connects the conditional distribution of the consensus given zero discrepancy to our target product distribution.
Theorem 1. Let be a consensus and be a discrepancy. Suppose all component densities are -integrable. Let be mutually independent for . Let denote the law of conditional on in the neighborhood of zero:
Then, converges to in total variation:
Convergence in total variation further implies
Moreover, for any bounded measurable , we have
2.2. Conditional mean via regression
By Theorem 1, we can now recast product-expectation estimation as a regression problem. Given S samples from each of the K component distributions
we obtain the training pairs
We then regress on to estimate and evaluate the fitted function at zero:
PMC provides a general regression framework, see Algorithm 1. For a point estimate, a natural choice is to parameterize as a flexible neural network and minimize the empirical squared error , which ensures that the population optimum is the conditional mean: . More generally, our PMC framework turns a computing task into a modeling problem. Beyond the simple point estimate, we next develop a fully Bayesian formulation, and thus integrate the Bayesian workflow (Gelman et al., 2020) and uncertainty quantification.
Algorithm 1 Product Monte Carlo
1: for to do 2: for to do 3: Draw independently. 4: end for 5: . 6: . 7: end for 8: on via . 9: return ; when the regression is fully Bayesian, also return posterior uncertainty and draws , .
2.3. Fully Bayesian formulation, uncertainty quantification, and diagnostics
For simplicity, we present the scalar case . The vector-valued extension is immediate. We place a Gaussian process (GP) prior with an RBF kernel on the conditional mean and use a Gaussian likelihood
and a prior on the hyperparameters: global mean , lengthscale , amplitude , and noise scale .
Since , we can integrate out hyperparameters to propagate uncertainty and draw Monte Carlo samples from its posterior given all samples:
It is then straightforward to compute the posterior mean, variance and credible intervals for .
Uncertainty quantification is especially important when near-consensus observations are sparse. As we show in Section 3, without additional structural assumptions, the samples may provide little information about the product expectation. In typical Monte Carlo settings, the standard error scales as , whereas PMC's posterior variance reflects both Monte Carlo and epistemic uncertainty. For example, in our GP setting, as , we have so the variance rate is asymptotically. In the opposite limit , GP regression degenerates and the posterior variance remains , regardless of . Our fully Bayesian formulation integrates over , effectively allowing data to determine how strongly observations away from inform the product expectation. We evaluate PMC calibration in Section 4.
Our Bayesian formulation provides coherent uncertainty quantification and integrates PMC into a Bayesian workflow. Although we begin with a simple default model with homoscedastic Gaussian likelihood and a simple kernel, our PMC framework is not tied to a single fixed regression specification. When the model is adequate, inference is calibrated (Rubin, 1984). Otherwise, the workflow supports data-driven model building, diagnostics, and comparison (Gelman et al., 2020). For example, we may consider heteroscedastic noise, non-Gaussian likelihood, or flexible kernels, and we can select or average models. In practice, rather than assuming the correct regression specification, we recommend using posterior uncertainty and posterior predictive checks (PPC) to assess the adequacy of the fitted regression model. For example, Figure 3 illustrates an example: when is nonlinear, a misspecified linear regression is detected by small PPC p-values. See Figure 6 for another example.
3. Asymptotic theory
Theorem 1 guarantees that the target product expectation matches the conditional mean at zero:
Therefore, any consistent estimator of is consistent for . This identification requires independence across components, not i.i.d. draws within samplers. PMC supports Markov chain Monte Carlo (MCMC) sampling, retaining consistency under standard ergodicity or mixing conditions.
To further study convergence rates, we specialize our estimator to a local linear regression. We assume i.i.d. component sampler to simplify the theory.
Theorem 2 (Convergence Rate). Under the assumptions of Theorem 1, let be bounded and continuous, and let . Let and be versions of the conditional mean and covariance matrix satisfying
Let be a local linear estimator of with fixed kernel K and bandwidth . If Assumptions A.1–A.5 hold, the PMC estimator converges in probability


Figure 3: Using posterior predictive check in PMC. Left: true, well-specified, and misspecified regressions of on D. Right: posterior predictive distributions of T, a statistic of simulated data, under the two fitted models. Orange lines mark the observed statistics.
Moreover, its optimized leading-order asymptotic mean squared error (AMSE) is
where tr denotes the trace, denotes the Laplacian, and is a constant depending on the kernel.
Theorem 2 characterizes the convergence rate of PMC through four quantities: the discrepancy density at zero , the curvature of the conditional mean , the total conditional variance , and the discrepancy dimension .
The discrepancy density at zero determines the local effective sample size. With bandwidth , the expected number of samples near zero is
Intuitively, when is small, few samples lie near consensus, leaving PMC to rely more heavily on extrapolation. Proposition 1 shows that this discrepancy density at zero, and thereby the effective sample size, is smaller as (a) components move further away or (b) individual distributions are more diffuse.
Proposition 1 (When PMC is harder). Under Assumptions A.6–A.7 and Assumption A.8, the density of the discrepancy at zero is
where depends on , is the generalized Cauchy–Schwarz divergence, and H is the entropy.
The remaining AMSE components in Theorem 2 generally depend on the model and representation. For a concrete theoretical illustration, consider Gaussian components, whose product is also Gaussian:
PMC can attain the same parametric efficiency without density evaluations or this closed-form update.
Proposition 2 (Sharpness in Gaussian example). Consider either of the following PMC representations:
- Weighted average consensus, full discrepancy:
- Precision-weighted consensus, scalar discrepancy:
For , the leading-order AMSE of PMC for estimating with local linear regression is
where is a constant depending on the chosen representation and the component parameters.
The first AMSE term matches the Cramér–Rao lower bound for estimating the product mean with S draws from each Gaussian component. Thus, despite using only samples, PMC is asymptotically sharp, attaining the efficiency of the closed-form Gaussian estimator.
Proposition 2 links the choice of and to the convergence rate of PMC, although consistency holds for any admissible representation. With , any linear consensus attains the same rate. Scalar simplifies regression but attains the Cramér–Rao bound only with precision weighting. Our experiments use arithmetic-average consensus and full discrepancy.
4. Experiments
We demonstrate PMC on simulated data and three real applications: a privacy-restricted clinical trial, large-scale particle physics inference, and likelihood-free protein imaging. When can be evaluated, we benchmark PMC against GBF, the current state-of-the-art fusion method, and long-run MCMC targeting the product density. This deliberately favors the baselines, as PMC requires no density evaluations.
As we mentioned, PMC accommodates arbitrary regression models. We consider three implementations:
• PMC-OLS: ordinary least squares regression.
• PMC-MLP: multilayer perceptron neural network.
• PMC-GP: Gaussian process regression.
Benchmark with simulated data. We construct benchmarks varying the component family , distances between components, sample size , dimension , and number of components . We choose parametric families with closed-form products, withholding this information from PMC and GBF during training. We also include a parametric Oracle that knows the product family, estimates component parameters, and applies the closed-form product update.
We assess performance on (a) accuracy, measured by mean squared error (MSE) for estimating , and (b) computational cost, measured by wall-clock training time. PMC is the only method considered that is both density-evaluation-free and distribution-free.
We first consider Gaussian components and a scalar target function , varying dimension and sample size . Figure 4 shows PMC-OLS closely matching the Oracle in MSE and improving steadily with , as expected because the linear regression model is well-specified. Its sharp parametric rate agrees with Proposition 2, and it has the lowest training cost among PMC variants. PMC-MLP improves at large , but its MSE increases in higher dimensions. At a similar runtime, PMC-GP is significantly more accurate, especially in higher dimensions. All PMC methods outperform GBF at moderately large sample sizes and are substantially faster, often by orders of magnitude. We show GBF results only where computationally feasible, as its training time grows steeply with and .
Further simulations in Appendix B.1 show qualitatively similar results: PMC outperforms benchmarks in accuracy and cost. Results are averaged over 20 replications, with error bars showing standard errors.
In our fully Bayesian formulation, PMC-GP quantifies uncertainty in the target expectation, accounting for both Monte Carlo and epistemic uncertainty. We demonstrate how to incorporate this uncertainty into a Bayesian workflow for model checking and diagnostics. Figure 5 assesses the calibration of the PMC-GP posterior uncertainty. Although PMC-GP is a Bayesian model and is not designed to guarantee frequentist calibration, its uncertainty estimates provide reasonable frequentist coverage. In contrast, GBF captures only Monte Carlo uncertainty, which is computed from the newly generated particles and therefore depends on particle count. As the number of particles increases, its intervals become increasingly undercovered. To examine how posterior uncertainty provides built-in PMC diagnostics, Figure 6 considers a simple Gaussian example with two components, and . As increases and the components become more separated, the PMC-GP posterior uncertainty increases, providing a warning that the component distributions have limited overlap, the available data provide little information about the target expectation, and the product-estimation problem becomes more difficult.
Next, we demonstrate PMC on real-data applications. When feasible, we compute the true expectation via a full-data MCMC, and evaluate the root mean squared error and runtime of subsample approximations.
Privacy-restricted clinical trial The respiratory data (Halekoh et al., 2006) is a public clinical-trial dataset with patients from two clinics randomized to placebo or treatment and binary respiratory outcomes. Researchers fit a logistic regression predicting the outcome from treatment and other covariates. We assume that privacy constraints prevent the clinics from sharing data, but researchers still need to compute the full-data posterior mean. We implement PMC and GBF to aggregate subposteriors. For an oracle truth, we also run MCMC on the pooled data, which would violate the assumed privacy constraints. For runtime, we separate (a) Subsample, the cost of obtaining local posterior samples by MCMC, from (b) Merge, the additional cost of aggregating them. Total is their sum. Full MCMC reports the MCMC runtime on the pooled data. Table 2 reports that all methods approximate the full-posterior mean well, while all PMC variants have lower aggregation

Method
Oracle
GBF
PMC-OLS
PMC-MLP
PMC-GP
Figure 4: MSE and runtime versus for the dimension-scaling experiment for the standardized sum of coordinates.
costs than GBF.
| Method | Estimation error | Merge (min) | Total (min) |
|---|---|---|---|
| Full MCMC | 0.0000 | - | 0.8152 |
| Subsample | - | - | 0.9796 |
| GBF | 0.0184 | 0.2047 | 1.1843 |
| PMC-OLS | 0.0110 | 0.0002 | 0.9799 |
| PMC-MLP | 0.0144 | 0.1069 | 1.0866 |
| PMC-GP | 0.0258 | 0.1009 | 1.0806 |
Table 2: Application in a privacy-restricted clinical trial.
Large-scale inference The HIGGS data (Baldi et al., 2014) contains 11 million simulated collision events labeled as Higgs-producing signal or background. We fit a logistic regression with 28 predictors, splitting the data into batches to reduce computational costs. Table 3 shows that PMC achieves small estimation errors with negligible computational cost relative to subsampling. Total runtime is roughly of full-data MCMC. GBF is computationally infeasible at this scale and omitted. Appendix B.2 reports additional large-scale inference examples, where GBF takes significantly longer even when feasible.
Simulation-based inference Recent advances in cryo-electron microscopy (cryoEM) enable inference on protein structures from 2D images using approaches such as SBI (Dingeldein et al., 2025; Lai et al., 2024). To mimic a realistic setting, we simulate noisy cryoEM images of the HSP90 protein using cryoJAX (O'Brien et al., 2026). We express the binding angle as a transformation of a latent parameter and perform posterior inference on the latent scale. Although the simulator is differentiable, the likelihood of the model is intractable because of additional nuisance parameters (e.g., rotations, translations, and measurement noise). For each image, we use neural

Figure 5: Calibration for two Gaussian components. PMC-GP is slightly conservative, while GBF's coverage worsens with particle count.

Figure 6: PMC-GP posterior variance of the target expectation versus mean separation between two Gaussian components.
| Method | Estimation error | Merge (min) | Total (min) |
|---|---|---|---|
| Full MCMC | 0.0000 | - | 308.1124 |
| Subsample | - | - | 35.2890 |
| PMC-OLS | 0.0020 | 0.0122 | 35.3012 |
| PMC-MLP | 0.0001 | 0.1092 | 35.3982 |
| PMC-GP | 0.0001 | 6.7192 | 42.0082 |
Table 3: Application in large-scale inference. PMC's minimal overhead keeps total cost a fraction of full-data MCMC.
posterior estimation to obtain individual posteriors, and then aggregate them with PMC into the full-data posterior. Figure 7 visualizes the subposteriors, the true combined posterior, and the PMC estimates. As shown in the table on the right of Figure 7, PMC-MLP nearly exactly recovers the full-data posterior mean, while PMC-GP is very close. Sampling the image-level subposteriors with SBI alone takes 1.7 minutes each, whereas the additional cost of PMC is negligible. As a demonstration of an SBI-PMC workflow, amortized SBI enables fast, parallel inferences across subsamples, while PMC provides a reliable and scalable way to aggregate them.
5. Discussion
Limitations. We introduced PMC, a framework to compute expectations under products of densities using only samples from the individual distributions. As quantified by Theorem 2 and Proposition 1, limited component overlap reduces the local effective sample size, making aggregation more reliant on extrapolation. In PMC, however, large posterior uncertainty or failed posterior predictive checks warn that the samples may not support reliable estimation. In such cases, we recommend sampling from the full target when feasible or redesigning the components to improve overlap. This limitation highlights a tradeoff, especially in large-scale inference: smaller batches reduce local sampling cost but can yield more divergent subposteriors, whereas larger ones improve overlap at a greater sampling cost. An interesting direction is therefore to integrate PMC and its diagnostics into a principled workflow for subsampling and aggregation.
Future directions. PMC accommodates arbitrary regression models, and we recommend using the Bayesian workflow for model checking and tuning. Moreover, if additional knowledge about the

| Method | Estimation error | Merge (min) | Total (min) |
|---|---|---|---|
| Sub-SBI | - | - | 1.7089 |
| PMC-OLS | 0.0684 | 0.0000 | 1.7089 |
| PMC-MLP | 0.0003 | 0.0134 | 1.7223 |
| PMC-GP | 0.0089 | 0.0042 | 1.7130 |
Figure 7: Application to SBI. Left: Image-level subposteriors and the combined posterior of the latent parameter z. PMC-MLP and PMC-GP estimates recover the true posterior mean. Right Table: PMC closely approximates the full-data posterior expectation with negligible merging cost relative to image-level subsampling SBI.
target distribution is available, it could be incorporated into the regression model to further improve efficiency. Furthermore, our implementation uses a fixed choice of and , but the framework permits learning or adapting them from data, which we view as a promising future direction. Finally, notice that the conditional distribution matches the full product distribution , not only its mean. This suggests that our consensus and discrepancy representation could be extended to generative sampling by replacing the current conditional-mean regression with flexible conditional density estimation to sample directly from the estimated conditional distribution , which we leave for future work.
References
Al-Shedivat, M., Gillenwater, J., Xing, E. P., and Rostamizadeh, A. (2021). Federated learning via posterior averaging: A new perspective and practical algorithms. In International Conference on Learning Representations.
Baldi, P., Sadowski, P., and Whiteson, D. (2014). Searching for exotic particles in high-energy physics with deep learning. Nature Communications, 5(1):4308.
Bernardo, J. M. and Smith, A. F. M. (1994). Bayesian Theory. Wiley.
Bock, R. K., Chilingarian, A., Gaug, M., Hakl, F., Hengstebeck, T., Jirina, M., Klaschka, J., Kotrč, E., Savicky, P., Towers, S., et al. (2004). Methods for multidimensional event classification: a case study using images from a Cherenkov gamma-ray telescope. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 516(2-3):511–528.
Cai, D., Gower, R. M., Blei, D. M., and Saul, L. K. (2025). Fisher meets Feynman: Score-based variational inference with a product of experts. In Advances in Neural Information Processing Systems.
Carvalho, L. M., Villela, D. A. M., Coelho, F. C., and Bastos, L. S. (2023). Bayesian inference for the weights in logarithmic pooling. Bayesian Analysis, 18(1):223–251.
Chan, R. (2021). DCFusion: Divide-and-conquer Monte Carlo fusion. R package version 1.0.
Chan, R. S. Y., Pollock, M., Johansen, A. M., and Roberts, G. O. (2023). Divide-and-Conquer Fusion. Journal of Machine Learning Research, 24(193):1–82.
Dai, H., Pollock, M., and Roberts, G. (2019). Monte Carlo fusion. Journal of Applied Probability, 56(1):174–191.
Dai, H., Pollock, M., and Roberts, G. O. (2023). Bayesian fusion: scalable unification of distributed statistical analyses. Journal of the Royal Statistical Society Series B: Statistical Methodology, 85(1):84–107.
Dingeldein, L., Silva-Sánchez, D., Evans, L., D'Imprima, E., Grigorieff, N., Covino, R., and Cossio, P. (2025). Amortized template matching of molecular conformations from cryoelectron microscopy images using simulation-based inference. Proceedings of the National Academy of Sciences, 122(23):e2420158122.
Gelman, A., Vehtari, A., Simpson, D., Margossian, C. C., Carpenter, B., Yao, Y., Kennedy, L., Gabry, J., Bürkner, P.-C., and Modrák, M. (2020). Bayesian workflow. arXiv preprint arXiv:2011.01808.
Genest, C. and Zidek, J. V. (1986). Combining probability distributions: A critique and an annotated bibliography. Statistical Science, 1(1):114–135.
Halekoh, U., Højsgaard, S., and Yan, J. (2006). The R package geepack for generalized estimating equations. Journal of Statistical Software, 15(2):1–11.
Hinton, G. E. (2002). Training products of experts by minimizing contrastive divergence. Neural Computation, 14(8):1771–1800.
Huang, Z. and Gelman, A. (2005). Sampling for bayesian computation with large datasets. Technical report, Department of Statistics, Columbia University. Unpublished manuscript.
Jonker, M. A. et al. (2024). Bayesian federated inference for estimating statistical models based on non-shared multicenter data sets. Statistics in Medicine.
Lai, J., Linero, A., and Yao, Y. (2024). Predictive variational inference: Learn the predictively optimal posterior distribution. arXiv preprint arXiv:2410.14843.
Liu, L., Jiang, X., Zheng, F., Chen, H., Qi, G.-J., Huang, H., and Shao, L. (2024). A Bayesian federated learning framework with online Laplace approximation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 46(1):1–16.
Mesquita, D., Blomstedt, P., and Kaski, S. (2020). Embarrassingly parallel inference with normalizing flows. In Proceedings of the 36th Conference on Uncertainty in Artificial Intelligence (UAI), volume 124 of Proceedings of Machine Learning Research. PMLR.
Neiswanger, W., Wang, C., and Xing, E. P. (2014). Asymptotically exact, embarrassingly parallel MCMC. In Proceedings of the Thirtieth Conference on Uncertainty in Artificial Intelligence, pages 623–632.
O'Brien, M. J., Silva-Sánchez, D., Woollard, G., Je, K., Hanson, S. M., Needleman, D. J., Cossio, P., Thiede, E. H., and Astore, M. A. (2026). CryoJAX: a cryo-electron microscopy image-simulation library in JAX. Acta Crystallographica Section D, 82(3).
Papamakarios, G. and Murray, I. (2016). Fast -free inference of simulation models with Bayesian conditional density estimation. Advances in neural information processing systems, 29.
Rubin, D. B. (1984). Bayesianly justifiable and relevant frequency calculations for the applied statistician. Annals of Statistics, pages 1151–1172.
Ruppert, D. and Wand, M. P. (1994). Multivariate Locally Weighted Least Squares Regression. The Annals of Statistics, 22(3):1346–1370.
Scott, S. L., Blocker, A. W., Bonassi, F. V., Chipman, H. A., George, E. I., and McCulloch, R. E. (2016). Bayes and big data: The consensus Monte Carlo algorithm. International Journal of Management Science and Engineering Management, 11(2):78–88.
Vehtari, A., Simpson, D., Gelman, A., Yao, Y., and Gabry, J. (2024). Pareto smoothed importance sampling. Journal of Machine Learning Research, 25(72):1–58.
Product Monte Carlo: Supplementary Materials
A. Proofs of Main Results
We use the following notation throughout the appendix. Let denote the dimension of the difference space. We write for -dimensional Lebesgue measure, for the class of functions on with continuous partial derivatives up to order , for the Jacobian of , and for the set of non-negative measurable functions on . We use and for the Kronecker and coordinatewise products, respectively. We write for terms of smaller asymptotic order in probability and when is a positive definite matrix.
A.1. Proof of Theorem 1
The following definition introduces the norm on density functions used throughout the proof.
Definition 4 ( norm). For a density g on X, the norm of g is
This definition describes the coordinates induced by the consensus function.
Definition 5 (Coordinate Map). The consensus and difference maps define the following coordinates:
The next two definitions introduce the sets used to analyze the conditioning event.
Definition 6 (Small Difference Set). The coordinate differences are small if they belong to
Definition 7 (Small Discrepancy Set). The discrepancy is small if the coordinate differences belong to
With these definitions in place, we can now prove Theorem 1.
Proof. Consider the following function that measures the consensus offset relative to the first component:
By the translation-equivariance assumption in Theorem 1, we write the consensus using the consensus offset:
Now, consider the following functions that measure the residual shifts:
Then, by Equation (1), we write each coordinate in terms of the consensus and residual shifts:
To establish surjectivity of the coordinate map, consider the following candidate preimage:
By the definitions of the residual shifts and the difference map, its difference coordinates are
By Equation (1), its consensus coordinate is
Therefore, the coordinate map is bijective with inverse
Now, consider the linear change of variables to the first component and the component differences:
It is easy to verify that the Jacobian of L is block lower triangular with identity blocks on the diagonal:
Then, by Equation (3), the linear change of variables is volume-preserving:
The inverse of the linear change of variables is
Then, by Equation (4), the inverse is also volume-preserving:
By the change-of-variables formula and translation invariance of Lebesgue measure, is volume-preserving:
(5)
By Equation (5), expectations of transformations of the coordinate map can be written as follows:
Then, by Equation (6), a pushforward density under the coordinate map is
By Definition 2, the consensus offset is origin-preserving:
Moreover, by the definitions of the residual shifts and Equation (8), the residual shifts are origin-preserving:
Therefore, by Equations (7) and (9), this density with null difference coordinates can be written as follows:
Using a telescoping sum argument, we obtain the following:
Now, let us denote slices of the density under the coordinate map as follows:
By Equation (11), the triangle and Hölder inequalities, and translation invariance of Lebesgue measure, we have
(12)
By the continuity assumption in Theorem 1 and by Equation (9), residual shifts are continuous at the origin:
By continuity of translations in and Equations (12) and (13), the density slices converge in :
Since is bounded away from the origin by assumption in Theorem 1, we obtain the following:
Since is continuous and origin-preserving by assumption in Theorem 1, the small-discrepancy sets satisfy
By Equations (15) and (16), small-discrepancy sets have positive, finite Lebesgue measure:
Now, consider the average density slice over the small-discrepancy set:
Then, its normalizing constant is defined as follows:
By Equation (17), the triangle inequality, and Tonelli's theorem, we obtain the following bound:
(18)
By Equations (14), (15), and (18), the average density slice converges in :
By Equation (10), Z can be written as the integral of the slice at the origin:
Then, by Equations (19) and (20) and the triangle inequality, converges to Z:
(21)
Since Z is positive by assumption, Equation (21) implies that becomes positive as the discrepancy shrinks:
Consequently, the probability of the conditioning event is positive:
By Equations (6), (17), and (22), the conditional law is well-defined and has density
By Definition 1 and Equations (7) and (9), the product density satisfies
By Equations (19), (21), (23), and (24), and the triangle inequality, we then have that
Hence, the conditional law of the consensus converges in total variation to the product law. ☐
A.2. Weighted-Average Consensus
This section defines the weighted-average consensus and states a result used in Section 3. It uses the full discrepancy mapping of Definition 3, which corresponds to choosing , and is the dimension of its range.
Definition 8 (Weighted-Average Consensus). Let satisfy . The weighted-average consensus with weights is
It is a consensus in the sense of Definition 2: it is continuous, , and for every .
Proposition 3. If and , then we have
A.3. Proof of Proposition 3
The result follows from a linear change of coordinates.
Proof. Consider the following function that measures the consensus offset relative to the first component:
By the definition of the linear consensus, we write the consensus using the consensus offset:
Now, consider the following functions that measure the residual shifts:
Given our choices of c and d, the Jacobian of the coordinate map can be written as follows:
Since adding columns 2, ..., K to column 1 preserves the determinant, the first row becomes
by the assumption on the matrices . Doing the same on the other rows, we obtain
where we used the fact that . By Equation (25), this matrix is block upper triangular, so
By Equation (2) and the change-of-variables formula, the density of the coordinate map is
By Equation (2), when the difference coordinate vanishes, the inverse coordinate map recovers the diagonal:
By Equation (7), the marginal density of D can be written as follows:
Consequently, by Equation (10) and Definition 1, the marginal density of D at the origin is
By Equation (26), we may evaluate the chosen conditional-density version at the origin:
Hence, we conclude that the conditional law of the consensus given null discrepancy is the product law:
A.4. Gaussian Components
Additional knowledge on the component distributions may yield stronger results. For example, with Gaussian components it is possible to pick a consensus that marginally recovers the product distribution and is independent of the discrepancy.
Proposition 4. Let the components be Gaussian:
where each and is positive definite. Let and , where
Then, we have that
A.5. Proof of Proposition 4
The result follows from standard properties of Gaussian distributions.
Proof. By Definition 1, in this case the product distribution is also Gaussian:
where
Since C is a linear combination of independent Gaussian random vectors, it is also Gaussian with mean
and covariance
Therefore, we conclude that the consensus is distributed according to the product distribution:
Since c and d are linear maps, C and D are jointly Gaussian. Their cross-covariances satisfy
Thus, since C and D are jointly Gaussian and uncorrelated, they are also independent:
A.6. Proof of Theorem 2
We first recall the general definition of the local linear regression estimator.
Definition 9 (Local linear regression). Let the data be generated as follows:
A local linear regression estimates the conditional mean function at a given point:
It does so by solving the following optimization problem:
where is a kernel and is a bandwidth. Then, the resulting estimate is
where and are the minimizers of Equation (27).
We now impose some regularity assumptions for Theorem 2. The first concerns the density of D.
Assumption A.1 (Regular discrepancy density). The density of D is continuously differentiable near the origin:
Moreover, it is positive at the origin:
The next two assumptions concern the smoothness of the conditional mean and covariance matrix.
Assumption A.2 (Smooth conditional mean). The function is twice continuously differentiable near the origin:
Moreover, its Laplacian is non-zero at the origin:
Assumption A.3 (Smooth conditional covariance). The function is continuous near the origin:
Moreover, its trace is positive at the origin:
The following assumption specifies the regularity conditions on the kernel K.
Assumption A.4 (Regular kernel). The kernel K is bounded, compactly supported, and radially symmetric:
Moreover, it is a probability density with finite second moment and finite roughness:
The final assumption specifies the asymptotic regime for the bandwidth.
Assumption A.5 (Bandwidth regime). The bandwidth satisfies
With these definitions and assumptions in place, we now prove Theorem 2.
Proof of Theorem 2. By Assumptions A.1–A.5 and standard results for multivariate local linear regression (Ruppert and Wand, 1994), we have an explicit expansion for the asymptotic MSE of .
Applying the local linear regression bias expansion componentwise (Ruppert and Wand, 1994) gives
(28) where is the second moment of :
Recall that the variance of a linear projection is the corresponding quadratic form of the covariance matrix:
Combining Equation (29) with the scalar variance expansion (Ruppert and Wand, 1994) gives
where is the roughness of :
By Assumption A.5 and Equation (28), the bias vanishes in probability:
Likewise, by Assumption A.5 and Equation (30), the total conditional variance vanishes in probability:
By Equation (32) and Chebyshev's inequality conditionally on , we have this convergence in probability:
\forall \varepsilon > 0.
(33)
Taking expectations in Equation (33) yields
Combining Equations (31) and (34), Slutsky's theorem gives
Since h is bounded, Theorem 1 implies convergence of the conditional expectation as the discrepancy shrinks:
By the definitions in Theorems 2 and 1 and Assumption A.2,
By the uniqueness of limits, Equations (36) and (37) imply
Combining Equations (35) and (38) yields consistency of the estimator for the target:
After dropping the and terms, Equations (28) and (30) yield the leading-order AMSE:
The first-order condition for minimizing the AMSE in Equation (39) over gives the following equation:
Multiplying Equation (40) by and solving for gives
so that the optimal bandwidth can be written as follows:
By Equations (40) and (41), at the optimal bandwidth we have
By Equations (39) and (42), the variance term at can be rewritten as
Substituting Equation (43) into Equation (39) gives
Substituting Equation (41) into Equation (44) and collecting exponents gives
where
A.7. Proof of Proposition 1
We first introduce two measures of divergence between probability densities.
Definition 10 (Cauchy–Schwarz divergence). The Cauchy–Schwarz (CS) divergence between two densities is
where and are -integrable densities on X.
Definition 11 (Generalized CS divergence). The generalized CS divergence extends to K densities:
where are -integrable densities on X.
Now, consider these regularity assumptions on the component densities and the discrepancy transformation.
Assumption A.6 ( -integrable components). Each component density is -integrable:
Assumption A.7 (Regular discrepancy transformation). The transformation preserves the dimension of :
It is continuously differentiable near the origin:
Moreover, its Jacobian is nonsingular at the origin:
Finally, is bounded away from the origin:
With these definitions and assumptions in place, we can now prove Proposition 1.
Proof of Proposition 1. By Equation (26), the density of the difference coordinates at the origin is
By Definition 3, the transformation is origin-preserving:
By Assumption A.7 and the inverse function theorem, admits a continuously differentiable local inverse:
Moreover, the Jacobian of the local inverse satisfies
By the bounded-away condition in Assumption A.7, we have
By Equations (45), (46), and (47), the change-of-variables formula gives
By Definition 11, we can express the exponentiated negative divergence as follows:
By Assumption A.6, each norm is finite, so raising both sides of Equation (49) to the power gives
Combining Equations (48) and (50) gives
where
A.8. Proof of the Entropy Lower Bound in Proposition 1
We first introduce another measure of dispersion for probability densities.
Definition 12 (Differential entropy). Let g be a probability density on X. Then, its differential entropy is
Now consider the following regularity assumption on the component densities.
Assumption A.8 (Finite component entropies). Each component density has finite differential entropy:
With these definitions and assumptions in place, we can now prove the entropy lower bound in Proposition 1.
Proof of the entropy lower bound in Proposition 1. Since the logarithm is a concave function, by Jensen's inequality, we have that
(51)
By Equation (51), we can lower bound the norm of each component in terms of its differential entropy:
Multiplying Equation (52) over the components gives the following lower bound on the product of norms:
Combining Equation (53) with Proposition 1 gives
A.9. Proof of Proposition 2
We begin by introducing a regularity assumption on the kernel.
Assumption A.9 (Regular kernel). The kernel K is bounded and continuous at the origin:
With this assumption in place, we can now prove Proposition 2.
Proof. Since the components are Gaussian, we can derive the asymptotic MSE without relying on Theorem 2.
Full difference discrepancy. We first consider the case and .
Since C and D are linear transformations of the jointly Gaussian vector x, they are also jointly Gaussian:
where the means and covariances are defined as follows:
The Jacobian of the difference map is constant:
By Equation (55), the last columns of form the identity matrix . Thus, the Jacobian has full row rank:
Since each component covariance matrix is positive definite, so is the covariance of the difference coordinates:
By the properties of the multivariate Gaussian distribution, we have the following:
Recall that when the discrepancy is null, Proposition 3 gives
where and are as in Proposition 4. Then, by comparing Equations (57) and (58), we obtain the following:
By Equations (57) and (59), we can specify the following linear model:
Since , the conditional mean function is affine in the discrepancy:
Scalar discrepancy. We now consider the case and .
By Proposition 4, the consensus is independent of the difference discrepancy and has the product distribution:
By Equation (62), the same relationship holds after applying the squared Euclidean norm to the difference map:
By Equation (54), the difference discrepancy has a multivariate Gaussian distribution:
where
By Equation (64) and the standard moments of a Gaussian quadratic form, we have the following:
Therefore, by Equation (65), the mean and variance of the scalar discrepancy are
By Equation (63), we can specify the following linear model:
Since , the conditional mean function is constant in the discrepancy:
Common argument. Equations (60)–(61) and (67)–(68) show that, in both cases, the local linear model is correctly specified. Hence, whenever the weighted design matrix is invertible, the estimator is unbiased:
In other words, by Equation (69), the bias is null:
By Equation (69), the conditional MSE equals the trace of the conditional covariance:
By Equations (60) and (67) and the Gauss–Markov theorem, the asymptotic MSE is minimized when
Thus, we may choose an asymptotically optimal bandwidth sequence diverging to infinity:
In fact, by Assumption A.9 and Equation (71), the kernel weights converge in probability to a constant:
Equations (56) and (66) show that the discrepancy covariance is positive definite in both cases:
By Equations (54) and (64), the discrepancy has a finite fourth moment in both cases:
Moreover, K is bounded by Assumption A.9. Thus, Equation (72) and the weak law of large numbers give
By Equations (73) and (74), the weighted design matrix is asymptotically invertible. Thus, the weighted least squares covariance formula and the continuous mapping theorem yield:
The standard random-design OLS covariance formula gives
Then, by Equations (75) and (76), the conditional covariance of our estimator is
Therefore, Equations (70) and (77) give the optimized leading-order asymptotic MSE:
where
Finally, Equations (69) and (77) and Chebyshev's inequality give the claimed consistency:
B. Additional Experimental Results
This section presents supplementary empirical results and details of our computational setup. Section B.1 reports further experimental findings across simulation settings. Section B.2 reports additional real-data results. Section B.3 compares the fusion methods in terms of estimation accuracy and computational cost. Section B.4 details the hardware and software used.
B.1. Additional Simulation Results
This section presents the remaining simulation results across data-generating processes and experimental settings, complementing those in the main text. We begin with a complete overview of the configurations considered:
• Gaussian:
– Univariate:
o Location and scale.
o Number of components.
– Bivariate:
o Mean separation.
o Isotropic variance scale.
o Marginal variance imbalance.
o Correlation strength and sign.
– Multivariate:
o Dimension.
• Gaussian mixtures:
– Symmetry.
– Mixture weights.
– Mixture scales.
– Number of components.
– Heterogeneity.
• Beta:
– Concentration.
– Heterogeneity.
– Skewness.
– Boundary singularities.
B.1.1. Univariate Gaussian: Location and Scale
We consider the product of univariate Gaussian components with fixed first component and varying second component in terms of location and scale. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 8 and 9 for and , respectively.

Figure 8: MSE and runtime versus S for with K = 2 univariate Gaussian components. Columns and rows vary , respectively. The first component is fixed with and .

Figure 9: MSE and runtime versus S for with K = 2 univariate Gaussian components. Columns and rows vary , respectively. The first component is fixed with and .
Across the settings, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , for which the linear model is misspecified. PMC-MLP and PMC-GP initially lag behind GBF but overtake it as the sample size increases for ; for , only PMC-GP overtakes GBF within the range of sample sizes shown, while PMC-MLP reaches parity at about . In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest.
B.1.2. Univariate Gaussian: Number of Components
We consider the product of K univariate Gaussian components with common location and either homogeneous or heterogeneous scales, with varying K. In the homogeneous case, the components are defined as follows:
In the heterogeneous case, the components are defined as follows:
It is easy to verify that, in both cases, the product of these components is again a Gaussian distribution:
The results are shown in Figures 10 and 11 for the homogeneous case and in Figures 12 and 13 for the heterogeneous case, for and , respectively.

Figure 10: MSE and runtime versus S for with K homogeneous univariate Gaussian components. Columns vary , and rows show MSE and runtime, respectively.

Figure 11: MSE and runtime versus S for with K homogeneous univariate Gaussian components. Columns vary , and rows show MSE and runtime, respectively.

Figure 12: MSE and runtime versus S for with K heterogeneous univariate Gaussian components. Columns vary , and rows show MSE and runtime, respectively.

Figure 13: MSE and runtime versus S for with K heterogeneous univariate Gaussian components. Columns vary , and rows show MSE and runtime, respectively.
Across the settings, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , for which the linear model is misspecified. For , PMC-MLP and PMC-GP overtake GBF for when ; for larger , and for with , they do not overtake GBF within the range of sample sizes shown. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest. In both the homogeneous and heterogeneous cases, the runtime of GBF increases with , while the runtime of PMC-MLP and PMC-GP remains largely unaffected by and that of PMC-OLS grows mildly but stays orders of magnitude below GBF.
B.1.3. Bivariate Gaussian: Mean Separation
We consider the product of bivariate Gaussian components with fixed first component and varying second component in terms of location along the diagonal. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 14 and 15 for and , respectively.

Figure 14: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .

Figure 15: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .
Across the settings, PMC-OLS closely matches the Oracle in terms of MSE. PMC-MLP and PMC-GP lag behind GBF by a factor of about 2 to 5 in MSE up to , with the gap growing with the location separation; they are comparable to or better than GBF at only for the smaller separations. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest.
B.1.4. Bivariate Gaussian: Isotropic Variance Scale
We consider the product of bivariate Gaussian components with fixed first component and varying second component in terms of isotropic scale. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 16 and 17 for and , respectively.

Figure 16: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .

Figure 17: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .
Across the settings, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , for which the linear model is misspecified. PMC-GP overtakes GBF for , while PMC-MLP only reaches parity at . In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest. Overall, it looks like increasing the scale of the second component makes the estimation problem harder for PMC-MLP, and for PMC-OLS when , at all sample sizes shown.
B.1.5. Bivariate Gaussian: Marginal Variance Imbalance
We consider the product of bivariate Gaussian components with fixed first component and varying second component in terms of the variance of its second coordinate. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 18 and 19 for and , respectively.

Figure 18: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .

Figure 19: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .
Across the settings, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , for which the linear model is misspecified. PMC-GP overtakes GBF for , while PMC-MLP only reaches parity for and remains behind for . In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest.
B.1.6. Bivariate Gaussian: Correlation Strength and Sign
We consider the product of bivariate Gaussian components with fixed first component and varying second component in terms of the strength and sign of its correlation. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 20 and 21 for and , respectively.

Figure 20: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .

Figure 21: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .
Across the settings, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , when the linear model is misspecified. PMC-MLP and PMC-GP initially lag behind GBF but overtake it in most settings as the sample size increases. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest.
B.1.7. Multivariate Gaussian: Dimension
We consider the product of multivariate Gaussian components with fixed Euclidean distance between their means, varying the dimension. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 22 and 23 for and , respectively.

Figure 22: MSE and runtime versus S for with K = 2 multivariate Gaussian components. Columns vary , and rows show MSE and runtime, respectively.

Figure 23: MSE and runtime versus S for with K = 2 multivariate Gaussian components. Columns vary , and rows show MSE and runtime, respectively.
Across the settings, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification. In low dimension ( ), PMC-MLP and PMC-GP lag behind GBF, whereas at p = 20 they outperform it, and at p = 10 PMC-MLP matches it at large sample sizes. In terms of training time, all PMC methods are considerably faster than GBF, with
PMC-OLS being the fastest. Overall, it looks like increasing the dimension makes the estimation problem more difficult, and the runtime of GBF seems to scale poorly with dimension, while the runtime of PMC-MLP is unaffected by the dimension and that of PMC-GP and PMC-OLS grows moderately, remaining far below GBF.
B.1.8. Gaussian Mixture: Symmetry
We consider the product of identical Gaussian-mixture components, each with two well-separated modes of equal weight and scale. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian mixture, now with three modes:
The results are shown in Figures 24 and 25 for and , respectively.

Figure 24: MSE and runtime versus S for with K = 2 symmetric bimodal Gaussian-mixture components.

Figure 25: MSE and runtime versus S for with K = 2 symmetric bimodal Gaussian-mixture components.
In this setting, PMC-OLS attains a lower MSE than the Oracle for , as expected given its correct specification, but fails for , for which the linear model is misspecified. PMC-MLP and PMC-GP outperform GBF for at almost all sample sizes. For , PMC-MLP and PMC-GP seem to still underperform GBF. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest, even faster than the Oracle. In particular, it looks like the runtime of GBF scales very poorly with the sample size.
B.1.9. Gaussian Mixture: Mixture Weights
We consider the product of Gaussian-mixture components sharing the same two modes, but with opposing weights on them. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian mixture, now with three modes:
The results are shown in Figures 26 and 27 for and , respectively.

Figure 26: MSE and runtime versus S for with K = 2 Gaussian-mixture components with opposing mode weights.

Figure 27: MSE and runtime versus S for with K = 2 Gaussian-mixture components with opposing mode weights.
In this setting, PMC-OLS attains a lower MSE than the Oracle for at most sample sizes, as expected given its correct specification, but fails for , for which the linear model is misspecified. PMC-MLP and PMC-GP systematically outperform GBF for , and they seem to still lag behind GBF for . In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest, even faster than the Oracle. In particular, it looks like the runtime of GBF scales very poorly with the sample size.
B.1.10. Gaussian Mixture: Mixture Scales
We consider the product of unimodal Gaussian-mixture components with different locations and heterogeneous scales. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 28 and 29 for and , respectively.

Figure 28: MSE and runtime versus S for with K = 2 unimodal Gaussian-mixture components with heterogeneous scales.

Figure 29: MSE and runtime versus S for with K = 2 unimodal Gaussian-mixture components with heterogeneous scales.
In this setting, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , for which the linear model is misspecified. PMC-MLP and PMC-GP lag behind GBF at small sample sizes and are comparable to it at intermediate ones. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest, even faster than the Oracle. In particular, it looks like the runtime of GBF scales very poorly with the sample size.
B.1.11. Gaussian Mixture: Number of Components
We consider the product of Gaussian-mixture components with different numbers of modes, weights, and scales. The components are defined as follows:
It is easy to verify that the product of these components is again a Gaussian mixture, now with 12 terms. If we write each component as follows:
where is the number of Gaussian terms in the mixture , then the product of these components can be expressed as follows:
where the means , the variances , and the weights satisfy the following relationships:
The results are shown in Figures 30 and 31 for and , respectively.

Figure 30: MSE and runtime versus S for with K = 3 Gaussian-mixture components.

Figure 31: MSE and runtime versus S for with K = 3 Gaussian-mixture components.
In this setting, PMC-OLS fails to estimate both the first and second moments, as expected given its misspecification. PMC-MLP underperforms GBF for and outperforms it for at , while PMC-GP underperforms GBF at all sample sizes. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest. In particular, it looks like the runtime of GBF scales very poorly with the sample size.
B.1.12. Gaussian Mixture: Heterogeneity
We consider the product of Gaussian-mixture components that are heterogeneous in their numbers of modes, weights, locations, and scales. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian mixture, now with 6 terms. If we write each component as follows:
where is the number of Gaussian terms in the mixture , then the product of these components can be expressed as follows:
where the means , the variances , and the weights satisfy the following relationships:
The results are shown in Figures 32 and 33 for and , respectively.

Figure 32: MSE and runtime versus S for with K = 2 heterogeneous Gaussian-mixture components.

Figure 33: MSE and runtime versus S for with K = 2 heterogeneous Gaussian-mixture components.
In this setting, PMC-OLS fails to estimate both the first and second moments, as expected given its misspecification. For , both PMC-MLP and PMC-GP outperform GBF at almost all sample sizes, while for PMC-MLP is comparable to GBF and PMC-GP underperforms it. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest. In particular, it looks like the runtime of GBF scales very poorly with the sample size.
B.1.13. Beta: Concentration
We consider the product of symmetric Beta components, and , either with homogeneous or with heterogeneous concentrations. In the homogeneous case, the components are identical and are defined as follows:
In the heterogeneous case, the components have different concentrations and are defined as follows:
It is easy to verify that, in both cases, the product of these components is again a Beta distribution:
The results are shown in Figures 34 and 35 for the homogeneous case and in Figures 36 and 37 for the heterogeneous case, for and , respectively.
In both cases, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , for which the linear model is misspecified. In both cases, PMC-MLP and PMC-GP outperform GBF for large sample sizes, at least for , while for they still underperform GBF in the uniform case and overtake it at for the other concentrations. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest.

Figure 34: MSE and runtime versus S for with K = 2 homogeneous Beta components. Columns vary .

Figure 35: MSE and runtime versus S for with homogeneous Beta components. Columns vary .

Figure 36: MSE and runtime versus S for with heterogeneous Beta components with and .

Figure 37: MSE and runtime versus S for with heterogeneous Beta components with and .
B.1.14. Beta: Skewness
We consider the product of skewed Beta components, with skewness either in the same direction or in opposite directions. In the matching case, the components are identical and are defined as follows:
It is easy to verify that the product of these two components is again a Beta distribution:
In the opposing case, the components are mirror images of each other and are defined as follows:
Similarly, the product of these two components is again a Beta distribution:
The results are shown in Figures 38 and 39 for the matching case and in Figures 40 and 41 for the opposing case, for and , respectively.
In the matching case, PMC-OLS fails to estimate both the first and second moments, as expected given its misspecification. PMC-MLP and PMC-GP underperform GBF, with the gap shrinking as the sample size increases. In the opposing case, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , for which the linear model is misspecified. In the opposing case, PMC-MLP and PMC-GP are comparable to GBF at and tend to outperform it at larger sample sizes. In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest.

Figure 38: MSE and runtime versus S for with K = 2 Beta components with and .

Figure 39: MSE and runtime versus S for with K = 2 Beta components with and .

Figure 40: MSE and runtime versus S for with K = 2 Beta components with and .

Figure 41: MSE and runtime versus S for with K = 2 Beta components with and .
B.1.15. Beta: Boundary Singularities
We consider the product of Beta components whose densities diverge at opposite endpoints of the unit interval. The components are defined as follows:
It is easy to verify that the product of these two components is again a Beta distribution, which is bounded even though its components are not:
The results are shown in Figures 42 and 43 for and , respectively.

Figure 42: MSE and runtime versus S for with K = 2 Beta components with and .

Figure 43: MSE and runtime versus S for with K = 2 Beta components with and .
In this setting, PMC-OLS closely matches the Oracle in terms of MSE for , as expected given its correct specification, but fails for , for which the linear model is misspecified. PMC-MLP and PMC-GP outperform GBF only at the largest sample size ( ). In terms of training time, all PMC methods are considerably faster than GBF, with PMC-OLS being the fastest.
B.2. Additional Real-Data Results
MAGIC. We complement the large-scale computation application with an experiment on the MAGIC dataset (Bock et al., 2004), a scientific dataset with 19,020 samples and 10 features. We fit a logistic regression model to predict the binary label from the features, for a total of 11 coefficients including the intercept, and split the data into batches. Because the sample size is much smaller than in the HIGGS experiment, GBF is feasible here.
Table 4 shows that, among the merging methods, PMC-GP achieves the lowest estimation error, followed closely by PMC-MLP, then GBF and PMC-OLS. The merging cost of GBF is large, about 27 minutes compared with less than one minute of batch MCMC, so its total runtime is about 28 times that of MCMC on the full dataset. In contrast, the merging cost of the PMC methods is negligible, and their total runtimes are comparable to that of MCMC on the full dataset.
Table 4: Results on the MAGIC data.
| Method | Estimation error | Merge (min) | Total (min) |
|---|---|---|---|
| Oracle | |||
| Batch | |||
| GBF | |||
| PMC-OLS | |||
| PMC-MLP | |||
| PMC-GP |
Evaluation metric. For the real-data tables, let denote the method estimate and the full-data or Oracle MCMC reference, respectively. We report
We use , , and for respiratory, HIGGS, and MAGIC, respectively, and for HSP90, where the metric reduces to absolute error.
B.3. Fusion Baseline Comparison
This section compares the fusion methods in terms of estimation accuracy and computational cost, and shows that GBF is at least as accurate and as fast as MCF and BF, with the advantage growing with the dimension. We begin with a complete overview of the configurations considered:
- Gaussian:
– Univariate:
• Location and scale.
– Bivariate:
• Mean separation.
– Multivariate:
• Dimension.
B.3.1. Univariate Gaussian: Location and Scale
We consider the product of univariate Gaussian components with fixed first component and varying second component in terms of location and scale. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 44 and 45 for and , respectively.

Figure 44: MSE and runtime versus S for with univariate Gaussian components. Columns and rows vary , respectively. The first component is fixed with and .

Figure 45: MSE and runtime versus S for with univariate Gaussian components. Columns and rows vary , respectively. The first component is fixed with and .
Across these settings, MCF and GBF are comparable in terms of MSE, while BF is decisively worse. In terms of runtime, GBF and MCF are comparable, while BF is the slowest. Moreover, notice that the runtime of MCF and GBF is almost constant, while the runtime of BF increases with the sample size.
B.3.2. Bivariate Gaussian: Mean Separation
We consider the product of K = 2 bivariate Gaussian components with fixed first component and varying second component in terms of location along the diagonal. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 46 and 47 for and , respectively.

Figure 46: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .

Figure 47: MSE and runtime versus S for with K = 2 bivariate Gaussian components. Columns vary . The first component is fixed with .
In these settings, MCF and GBF are comparable in terms of MSE, while BF is decisively worse. In terms of runtime, GBF is the fastest method, followed by MCF and then BF. Moreover, notice that the runtime of MCF and GBF is almost constant, while the runtime of BF increases with the sample size. Furthermore, notice that the runtime of MCF increases with the mean separation, while the runtime of GBF grows much more slowly.
B.3.3. Multivariate Gaussian: Dimension
We consider the product of multivariate Gaussian components with fixed Euclidean distance between their means, varying the dimension. The components are defined as follows:
It is easy to verify that the product of these two components is again a Gaussian distribution:
The results are shown in Figures 48 and 49 for and , respectively.

Figure 48: MSE and runtime versus S for with multivariate Gaussian components. Columns vary .

Figure 49: MSE and runtime versus S for with multivariate Gaussian components. Columns vary .
In these settings, GBF is more accurate than MCF in terms of MSE, while BF is decisively worse. In terms of runtime, GBF is the fastest method, followed by MCF and then BF. Moreover, notice that the runtime of MCF and GBF is almost constant, while the runtime of BF increases with the sample size. Furthermore, notice that the runtime of MCF increases with the dimension, while the runtime of GBF grows much more slowly.
B.4. Computational Setup
We describe the hardware and software used in our experiments below.
Hardware. On the shared machine, PMC-MLP and the simulation-study PMC-GP fits were trained on an NVIDIA RTX A4000 GPU, whereas the real-data PMC-GP fits, PMC-OLS, the simulation Oracles, and the fusion methods ran on the CPU. The real-data NUTS fits ran on the GPU. Runtime is the wall-clock time to fit the estimator for PMC and the Oracle, or to generate draws from the product distribution for the fusion methods. Except for HSP90 and the fusion baseline comparison in Appendix B.3, all timings were measured on the shared machine. Both the HSP90 experiment, including the neural posterior, PMC-OLS, PMC-MLP, PMC-GP, and the reference-posterior calculation, and the fusion baseline comparison were run on the CPU of a MacBook Pro with an Apple M3 Max, 14 cores, and 36 GB of memory; the HSP90 image simulator is only available on that machine.
Table 5: Hardware of the shared machine used for most experiments.
| Component | Specification |
|---|---|
| CPU | 2× AMD EPYC 7763 (128 physical cores, 256 threads, 255 online) |
| GPU | 4× NVIDIA RTX A4000 (16 GB memory each) |
| RAM | ~881 GiB usable, shared across all users |
| OS | Ubuntu 20.04 LTS |
Software. PMC and the Oracle are implemented in Python 3.12 with GPyTorch 1.15 and PyTorch 2.13 built for CUDA 13.0, and the fusion methods are run in R 4.4.2 using the R package DCFusion 1.0 (Chan, 2021).
Licenses. The HIGGS and MAGIC datasets are released under CC BY 4.0, the respiratory data are distributed with the R package geepack under GPL ( 3), DCFusion is released under GPL ( 2), and the HSP90 simulator is built on cryoJAX, which is released under LGPL-2.1.
Code availability. Code and outputs for the experiments are available at https://anonymous.4open.science/r/PMC. The HSP90 image simulator is third-party software that we do not have permission to redistribute; consequently, the complete HSP90 pipeline cannot be reproduced from this repository alone. For HSP90, we provide the saved posterior draws, reported outputs, and downstream analysis code. Regenerating the images or rerunning simulator-dependent stages requires access to the external simulator.
C. Hyperparameters
This section lists the hyperparameters used in all experiments. Section C.1 gives the settings shared by the baseline and supplementary benchmark suite in Appendix B.1, Section C.2 gives the corresponding common PMC settings, and Section C.3 lists the experiments that deviate from them. Section C.4 documents the main-text and diagnostic studies. Sections C.5, C.6, and C.7 cover the fusion methods and Oracle, the real-data experiments, and the simulation-based inference experiment, and Section C.8 explains their selection.
C.1. Shared Baseline Simulation Settings
The distributions of each experiment are described in Appendix B.1. Table 6 lists the settings shared by this baseline and supplementary benchmark suite.
Table 6: Settings shared by the baseline and supplementary benchmark suite in Appendix B.1.
| Setting | Value |
|---|---|
| Methods | PMC-OLS, PMC-MLP, PMC-GP, GBF, and the Oracle |
| Targets | and |
| Sample sizes | and, only for the univariate Gaussian location and scale experiment, |
| Realized sample size | Poisson() draws per component |
| Replications | independent replications per experimental configuration |
| Number of components | , except in the experiments on the number of components |
| Seeds | for base seed , replicate , and zero-based configuration index , the seed is , where is the number of configurations. Most experiments use ; homogeneous and heterogeneous -scaling use and , respectively, and dimension scaling uses |
| Consensus and discrepancy | as in Table 7 |
| GBF particles | see Section C.5 |
C.2. Common PMC Settings
For PMC-MLP, ensemble size 2 averages predictions from two independently initialized networks.
Exact posterior inference for the GP formulation in Section 2.3 requires factorizing an covariance matrix, with time and memory, and integration over the GP and likelihood hyperparameters adds further cost. This is computationally infeasible at the sample sizes considered here, so PMC-GP uses a sparse variational approximation. Let denote inducing inputs and let
We approximate the posterior of the inducing values by
which induces the approximate process posterior
Writing , the variational parameters and maximize the evidence lower bound
The PMC estimate and its uncertainty are obtained from the marginal .
Approximation settings. We use inducing inputs, initialized at empirical quantiles of the standardized discrepancies and then fixed. The common suite uses a Matérn-3/2 kernel. The GP mean, kernel lengthscale and output scale, and likelihood noise variance correspond to , , , and in Section 2.3.
Optimization. Natural gradients optimize a and B. The GP and likelihood hyperparameters are fixed, so the listed Adam learning rate is inactive. Each update uses the full sample, making the listed batch size inactive. Training stops after at most 40 updates, or after at least 20 epochs when the objective has not improved by a relative tolerance of for 5 epochs.
Uncertainty. The reported 0.95 interval is the central Gaussian interval under , conditional on the fixed hyperparameters. Local neighborhoods are disabled, so all observations inform this distribution and the listed neighborhood-size bounds are inactive.
Table 7 lists the resulting PMC settings shared by the baseline and supplementary benchmark suite; deviations are listed in Section C.3.
C.3. Deviations from the Common Settings
Within the baseline and supplementary benchmark suite, Table 8 lists the experiments whose PMC settings differ from the common ones, and Table 9 lists the settings that were tuned separately for individual cells; all other settings are as in Table 7.
C.4. Details of Main-Text Experiments and Diagnostics
Posterior predictive check. Figure 3 uses S = 500 independent paired draws from
For each pair, we define
The true conditional mean is
We compare the misspecified linear mean with the well-specified quadratic mean:
For , the Bayesian polynomial regression uses
We use posterior-predictive draws and discrepancy bins. The data seed is 2026100301, and the posterior seeds are 2026100302 and 2026100303 for the linear and quadratic models, respectively. Let be the least-squares polynomial fit of the corresponding degree and its residual. After sorting observations by , we divide them into near-equal bins and compute
For each posterior draw, we generate a replicated response dataset at the observed values , refit the polynomial model of the same degree, and recompute T. We define the PPC value as
Table 7: Common PMC settings used in the baseline and supplementary benchmark suite.
| PMC-OLS Polynomial degree | 1 |
|---|---|
| PMC-MLP | |
| Hidden layers | 64, 64, 64 |
| Activation | ReLU |
| Ensemble size | 2 |
| Optimizer | Adam |
| Weight decay | 0 |
| Learning rate, mean target | |
| Learning rate, square target | |
| Learning-rate schedule | cosine |
| Batch size | 1024 |
| Training steps | adaptive (Section C.8) |
| Loss | MSE |
| PMC-GP | |
| Kernel | Matérn-3/2 |
| Inducing points | 64 |
| Maximum updates | 40 |
| Minimum epochs | 20 |
| Early-stopping patience (epochs) | 5 |
| Early-stopping relative tolerance | |
| Natural-gradient learning rate | 0.03 |
| Adam learning rate, kernel hyperparameters | 0.03 |
| Batch size | 8192 |
| Full-batch updates | Yes |
| Learn inducing locations | No |
| Fixed kernel hyperparameters | Yes |
| Fixed mean | -0.0014 |
| Fixed lengthscale | 6 |
| Fixed output scale | 0.5 |
| Fixed noise variance | 0.64 |
| Floating-point precision | 64-bit |
| Prediction interval level | 0.95 |
| Minimum local neighborhood size | 256 |
| Maximum local neighborhood size | 131072 |
| Local neighborhood exponent | None (full sample) |
| All PMC methods | |
| Sampling | i.i.d. |
| Consensus weights | uniform |
| Discrepancy centering | mean |
| Discrepancy construction | consecutive differences |
The resulting values are
Dimension scaling. Figure 4 uses
Table 8: Baseline and supplementary experiments whose PMC settings differ from the common settings.
| Experiments | Setting | Common value | Value used |
|---|---|---|---|
| Multivariate Gaussian, dimension | Kernel | Matérn-3/2 | RBF |
| Fixed mean | -0.0014 | 0.0000 | |
| Fixed lengthscale | 6 | 3 |
Table 9: Per-cell hyperparameter overrides.
| Experiment | Method | Cell | Changed settings |
|---|---|---|---|
| Univariate Gaussian,location and scale | PMC-MLP | ,, square | learning rate , training steps 16,000 |
| PMC-MLP | ,, square | hidden layers 256, 256, 256,learning rate , batch size 4096 | |
| PMC-GP | ,, identity | fixed lengthscale 16 | |
| PMC-GP | ,, square | fixed lengthscale 20 | |
| Univariate Gaussian,number ofcomponents,homogeneous | PMC-GP | , , identity | kernel RBF, fixed lengthscale 16 |
| PMC-GP | , , square | kernel RBF, fixed lengthscale 16 | |
| Univariate Gaussian,number ofcomponents,heterogeneous | PMC-MLP | , identity | hidden layers 256, 256, 256,activation SiLU, learning rate , batch size 8192 |
| PMC-GP | , identity | kernel RBF, inducing points 128, fixed lengthscale 4, fixed noise variance 1 | |
| Bivariate Gaussian,isotropic variancescale | PMC-MLP | , , square | hidden layers 256, 256, 256,activation SiLU, learning rate , batch size 8192 |
| PMC-MLP | , , square | hidden layers 256, 256, 256,activation SiLU, learning rate , batch size 8192 | |
| PMC-GP | , , square | kernel RBF, fixed mean 0.0000,fixed lengthscale 2 | |
| PMC-GP | , , square | fixed mean 0.0000, fixed lengthscale 4, fixed noise variance 1 | |
| Bivariate Gaussian,marginal varianceimbalance | PMC-GP | , , square | kernel RBF, fixed mean 0.0000,fixed lengthscale 2 |
The component distributions are
Their normalized product and the target are
so the estimand is fixed as the dimension changes. The nominal per-component sample sizes are
In each replicate, we draw a common realized sample size
and generate N i.i.d. draws from each component. The paired samples yield
Each cell has 20 independent replicates. Points show arithmetic means across replicates, and error bars show one standard error. In replicate r, the squared error is
Runtime measures estimator fitting or aggregation and excludes data generation.
The available GBF sample sizes are
GBF results are reported only for configurations completed within a 24-hour wall-time limit. Runs beyond the displayed sample-size ranges, including all configurations, did not complete within this limit. For the , cell only, the empirical full covariance matrices are singular or severely ill-conditioned because the realized sample size is comparable to the dimension, so GBF uses diagonal sample covariance matrices for both the fitted Gaussian components and the covariance preconditioners; all other GBF cells use full sample covariance matrices. The Oracle estimates each component's Gaussian parameters and combines the fitted components analytically.
Calibration. Figure 5 uses
The consensus and discrepancy are
The target is
Table 10: Method settings for the dimension-scaling experiment.
| PMC-OLS Polynomial degree | 1 |
|---|---|
| PMC-MLP | |
| Hidden layers | 64, 64, 64 |
| Activation | ReLU |
| Discrepancy centering | mean |
| Optimizer | Adam |
| Learning rate | |
| Learning-rate schedule | cosine |
| Batch size | 1024 |
| Training steps | 4000 |
| Ensemble size | 1 |
| Loss | MSE |
| PMC-GP | |
| Kernel | RBF |
| Inducing points | 64 |
| Learn inducing locations | No |
| Learn kernel hyperparameters | Yes |
| Maximum updates | 1600 |
| Minimum epochs | 10 |
| Early-stopping patience (epochs) | 3 |
| Early-stopping relative tolerance | |
| Natural-gradient learning rate | 0.003 |
| Adam learning rate, kernel hyperparameters | 0.003 |
| Batch size | 8192 |
| Floating-point precision | 32-bit |
| GBF | |
| Output particles | |
| Coalescence time | optimal rule |
| Time mesh | optimal rule |
The displayed experiment uses
independent replicates, each with exactly draws from each component. The base seed is 20261001. The nominal coverage levels are
For each method, nominal level , and replicate, the Gaussian interval is
Its empirical coverage is
The method settings are listed in Table 11.
For PMC-GP, is the latent posterior standard deviation. For GBF, it is
with the square root of the particle count used when the final ESS is unavailable.
Table 11: Method settings for the calibration experiment.
| PMC-GP | |
|---|---|
| Kernel | Matérn-3/2 |
| Inducing points | 64 |
| Learn inducing locations | No |
| Learn kernel hyperparameters | Yes |
| Maximum updates | 40 |
| Minimum epochs | 20 |
| Early-stopping patience (epochs) | 5 |
| Early-stopping relative tolerance | |
| Natural-gradient learning rate | 0.03 |
| Adam learning rate, kernel hyperparameters | 0.03 |
| Batching | full batch |
| Floating-point precision | 64-bit |
| GBF | |
| Output particles | 1000, 10,000, or 100,000 |
| Coalescence time | optimal rule |
| Time mesh | optimal rule |
| Initial CESS threshold | 0.2 |
| Preconditioning | variance |
| Diffusion estimator | Poisson |
| ESS threshold | 0.5 |
| Number of cores | 1 |
GP posterior variance versus overlap. Figure 6 uses
The target and normalized product are
The experiment uses
independent replicates, each with exactly draws from each component. The base seed is 26100500. Within a replicate, common standard-normal draws are reused across all values of :
The consensus and discrepancy satisfy
and hence
Within each replicate, one reference GP is fitted at , and its learned hyperparameters are held fixed across mean separations. Therefore, physical zero discrepancy at mean separation corresponds to querying the reference GP at discrepancy ; the response translation changes the posterior mean but not its variance. Table 12 gives the GP settings.
For each , the plotted value is the median latent posterior variance across the replicates. This variance excludes observation noise, and the vertical axis uses a logarithmic scale.
Table 12: PMC-GP settings for the posterior-variance experiment.
| PMC-GP | |
|---|---|
| Kernel | RBF |
| Inducing points | 64 |
| Learn inducing locations | No |
| Learn kernel hyperparameters | Yes |
| Maximum updates | 1600 |
| Minimum epochs | 10 |
| Early-stopping patience (epochs) | 3 |
| Early-stopping relative tolerance | |
| Natural-gradient learning rate | 0.003 |
| Adam learning rate, kernel hyperparameters | 0.003 |
| Batch size | 8192 |
| Floating-point precision | 32-bit |
C.5. Fusion Methods and Oracle
In the supplementary benchmark suite, GBF uses 100,000 output particles for the Gaussian and Beta experiments and particles for the Gaussian mixture experiments. The fusion baseline comparison uses 100,000 output particles and 20 paired replications, with all methods evaluated on the same simulated component samples. The number of draws from each component is Poisson(), where
with also included in the univariate experiment. The base seeds are 20260826, 20260831, and 20260901 for the univariate, bivariate, and multivariate experiments, respectively. Table 13 lists the remaining fusion-method settings, and Table 14 describes the Oracle for each component family.
C.6. Real-Data Experiments
In all three real-data experiments, we fit the logistic regression model
The coefficient dimensions are 5, 29, and 11 for respiratory, HIGGS, and MAGIC, respectively. We leave the intercept unchanged and standardize every other predictor using its full-data mean and standard deviation. The respiratory batches are the two observed clinical centers, containing 56 and 55 observations. HIGGS is partitioned into 10 batches of 1.1 million observations using seed 91011, and MAGIC into 10 batches of 1902 observations using seed 91001.
The Oracle is NUTS applied to the full data, and each batch is sampled using the same sampler. A batch of size uses prior scale , where is the full sample size, so that the product of the fractional priors recovers the full-data prior. Table 15 lists the data, sampler, and GBF settings. GBF was not run for HIGGS because it was computationally infeasible at this scale.
For PMC, we use all posterior draws from each batch and pair draws independently across batches. The consensus is the equally weighted average, the discrepancy consists of consecutive differences, and the target functions are
Table 16 lists the PMC settings shared by the three experiments.
Table 13: Settings of the fusion methods in the simulation experiments.
| Setting | Value |
|---|---|
| GBF | |
| Output particles | 100,000 (Gaussian and Beta components); (Gaussian mixtures) |
| Coalescence time and time mesh | chosen by the SSH guidance of the DCFusion package, with a minimum conditional effective sample size of 0.2 at initialization |
| Preconditioning | sample variance (univariate Gaussians) or sample covariance (bi-variate and multivariate Gaussians) of each component |
| Resampling threshold | resample when the effective sample size falls below half of the number of particles |
| Resampling method | multinomial |
| Diffusion estimator | Poisson |
| Number of cores | 1 |
| Mixture components | each component is fitted by EM with the true number of modes, a full covariance, 3 random restarts, at most 100 iterations, a tolerance of , and a variance floor of |
| Beta components | fit each component by fixed-support maximum likelihood, perform fusion in Jacobian-corrected logit coordinates using the auxiliary-logit sample variance for preconditioning, and transform the output back to (0, 1) |
| MCF and BF (fusion baseline comparison) | |
| MCF coalescence time | 1, with a single time step |
| BF coalescence time and time mesh | chosen by the same guidance as for GBF |
| BF preconditioning | identity |
Table 14: Computation of the Oracle in the simulation experiments.
| Components | Oracle |
|---|---|
| Gaussian | fit the mean and covariance of each component from its draws and combine them analytically into the Gaussian product |
| Beta | fit the two shape parameters of each component by maximum likelihood, with location 0 and scale 1 fixed, and combine them analytically into the Beta product |
| Gaussian mixture | fit each component by EM with the true number of modes, a full covariance, 10 random restarts, at most 1000 iterations, a tolerance of , and a variance floor of , and compute the product exactly |
C.7. Simulation-Based Inference
Table 17 lists the settings of the HSP90 experiment. The protein binding angle is obtained from the latent parameter through . A single amortized NPE-C network is trained once and then conditioned separately on each of the ten observed images. Each image is independently standardized to zero mean and unit variance. The image-level posteriors use the fractional prior on the logit-scale parameter , so that the product of the exact image-level posteriors would equal the posterior given all images under the prior . PMC estimates the two targets and . The reference combined posterior is the normalized product of the ten fitted NPE-C subposterior densities; its moments are computed using random-walk Metropolis and verified by numerical quadrature. The settings of PMC-GP are the recommended defaults of the implementation, which differ from the ones used in the simulations.
Table 15: Settings of the real-data experiments.
| Setting | Respiratory | HIGGS | MAGIC |
|---|---|---|---|
| Data | |||
| Observations n | 111 | 11,000,000 | 19,020 |
| Coefficients | 5 | 29 | 11 |
| Number of batches | 2 | 10 | 10 |
| Oracle and batch sampler (NUTS) | |||
| Prior scale | 2 | 2 | 2 |
| Batch prior scale | 2.82, 2.84 | 6.32 | 6.32 |
| Chains | 4 | 4 | 4 |
| Warmup iterations | 1000 | 5000 | 1000 |
| Post-warmup draws per chain | 10,000 | 10,000 | 10,000 |
| Mass matrix | diagonal | dense | dense |
| Initialization | default | MAP (up to 500 iterations) | default |
| Precision | 32-bit | 64-bit | 32-bit |
| Seed | 91011 | 91011 | 91011 |
Table 15: Settings of the real-data experiments (continued).
| Setting | Respiratory | HIGGS | MAGIC |
|---|---|---|---|
| GBF | |||
| Run | Yes | No | Yes |
| Particles per level | 1000 | – | 1000, 1000 |
| Merge factors | 2 | – | 5, 2 |
| Time mesh | 0.5, 1 | – | 0.5, 1 |
| Preconditioning | Yes | – | Yes |
| Resampling | residual | – | residual |
| Resampling threshold (ESS fraction) | 0.5 | – | 0.5 |
| Diffusion estimator | NB | – | NB |
| Number of cores | 1 | – | 1 |
| Seed | 93011 | – | 93011 |
C.8. Selection of the Hyperparameters
Experiment-level settings were selected manually rather than through an automated search. Where indicated in the tables, PMC-GP kernel hyperparameters were learned during fitting. We fixed one set of PMC settings for the baseline simulation suite (Section C.2) and tuned individual cells separately in a few cases, namely the largest sample sizes in settings with 20 components, variance scaling, or variance imbalance, and the largest cell of the location and scale grid; each such override was compared with the common setting in a paired comparison over 20 or 30 replicates, and Table 9 lists them. For PMC-GP in this suite, the kernel hyperparameters are fixed rather than learned. The additional main-text and diagnostic studies use the settings documented in Section C.4. The real-data settings were selected manually, whereas HSP90 PMC-GP uses the implementation's recommended defaults.
The adaptive number of training steps of PMC-MLP grows with the square root of the sample size:
where is the realized sample size of the simulated data, drawn from a Poisson distribution with mean equal to the nominal sample size. It equals 200 steps for and reaches the cap of 8,000.
steps at .
Table 16: PMC settings in the real-data experiments.
| Setting | Value |
|---|---|
| All PMC methods | |
| Posterior draws per batch | 40,000 |
| Sampling | independent pairing across batches |
| Consensus weights | equal (1/K) |
| Discrepancy construction | consecutive differences |
| Targets | and |
| Seeds | 94011 (mean), 94012 (square) |
| PMC-OLS | |
| Polynomial degree | 1 |
| Device | CPU |
| PMC-MLP | |
| Hidden layers | 32, 32 |
| Activation | ReLU |
| Optimizer | Adam |
| Learning rate | |
| Learning-rate schedule | cosine |
| Batch size | 128 |
| Training steps | 1000 |
| Ensemble size | 5 |
| Discrepancy centering | target |
| Loss | MSE |
| Device | GPU |
| PMC-GP | |
| Kernel | Matérn-3/2 (mean), RBF (square) |
| Inducing points | 8, with learned locations |
| Kernel hyperparameters | learned |
| Batch size | 8192 |
| Natural-gradient learning rate | 0.03 |
| Adam learning rate | 0.03 |
| Minimum epochs | 10 |
| Early-stopping patience (epochs) | 3 |
| Early-stopping relative tolerance | |
| Floating-point precision | 32-bit |
| Device | CPU |
Table 17: Settings of the HSP90 experiment.
| Setting | Value |
|---|---|
| Experiment | |
| Number of images | 10 |
| Posterior draws per image | 1,000 |
| Parameter | , with true value |
| Image-level prior on | |
| Prior given all images | |
| Image simulator | |
| Pose | (0, 0, 0, 90, 90, 0) |
| Defocus | 1500 |
| Noise strength | 1 |
| Random key and noise | independent for each image |
| Neural posterior | |
| Method | NPE-C |
| Embedding network | convolutional |
| Density estimator | neural spline flow |
| Training simulations | 1,024 |
| Training batch size | 64 |
| Maximum epochs | 200 (training stopped at epoch 57) |
| Seeds | training 1000, observation 20000, posterior sampling 30000 |
| All PMC methods | |
| Parameter space | |
| Sampling | i.i.d. |
| Consensus weights | equal (0.1) |
| Discrepancy construction | consecutive differences |
| Seeds | 94011 (mean), 94012 (square) |
Table 17: Settings of the HSP90 experiment (continued).
| Setting | Value |
|---|---|
| PMC-OLS | |
| Polynomial degree | 1 |
| PMC-MLP | |
| Hidden layers | 32, 32 |
| Activation | ReLU |
| Optimizer | Adam |
| Learning rate | |
| Learning-rate schedule | cosine |
| Batch size | 128 |
| Training steps | 1000 |
| Ensemble size | 5 |
| Discrepancy centering | target |
| Loss | MSE |
| PMC-GP | |
| Kernel | Matérn-3/2 (mean), RBF (square) |
| Inducing points | 8, with learned locations |
| Kernel hyperparameters | learned |
| Batch size | 8192 |
| Natural-gradient learning rate | 0.03 |
| Adam learning rate | 0.03 |
| Minimum epochs | 10 |
| Early-stopping patience (epochs) | 3 |
| Early-stopping relative tolerance | |
| Floating-point precision | 32-bit |
| Reference combined posterior | |
| Sampler | random-walk Metropolis on |
| Chains | 4 |
| Burn-in | 2000 iterations, with the step size adapted toward an acceptance rate of 0.44 |
| Draws per chain | 5000 |
| Seed | 40000 |
| Check | quadrature on a grid of 20,001 points on |