arXiv:2610.12735cs.CVOct 2026

Manuscript Offprint

arXiv:2610.12735

Reference-Free Food Volume Estimation from Egocentric Stereo Video

Vivan Kumar, Gautham Vinod, Fengqing Zhu

Vivan Kumar ID^{ID}, Gautham Vinod ID^{ID}, and Fengqing Zhu ID^{ID}

Elmore Family School of Electrical and Computer Engineering, Purdue University,

West Lafayette, IN 47907, USA

kumar733@purdue.edu

Abstract. Current stereo vision-based approaches for food portion estimation are hindered by the user burden of using a mobile phone to capture multiple images or placing a reference object in the scene for scale calibration. As a step towards passive dietary intake monitoring, we introduce a method that uses stereo video from a wearable egocentric device to reconstruct food items in true physical scale to accurately estimate volume. By utilizing FoundationStereo for zero-shot stereo matching, SAM 2 for food segmentation, and TSDF fusion over a set of keyframes, our method yields a visually and metrically accurate 3D mesh of any plated food item from a single stereo recording. We leverage the unique offerings of wearables, such as a factory-calibrated stereo baseline and camera poses estimated on-device via visual-inertial odometry (VIO), to perform fully automatic reconstruction without a scale reference object in the scene. We show strong initial volume estimation results across five recorded food items, achieving a mean absolute percentage error of 9.1%.

Keywords: Food volume estimation · Egocentric vision · Stereo depth · 3D reconstruction

1 Introduction

Image-based methods have introduced a new paradigm for dietary monitoring, enabling food portion estimation using one or a few images captured on consumer devices such as mobile phones. However, these methods are constrained by the loss of 3D information in monocular images, requiring methods such as monocular depth estimation and reference objects placed in the scene to estimate the true physical scale of food items [5,6]. Alternatively, stereo images more naturally mimic how the human eyes perceive depth and provide a significantly more accurate cue for estimating true scale through pixel disparity; however, existing methods built around stereo images maintain the user burden of manually capturing images on a mobile phone and placing a reference object in the scene [2]. These methods are also more likely to fail on glossy or textureless food items due to the fragility of traditional stereo matching methods.

With the rise of wearable consumer devices equipped with stereo cameras and rich sensor suites [11], food portion estimation methods are transitioning towards

V. Kumar et al.

Figure

Input Egocentric Stereo Video

Ground Truth: 376.0 mL

Mesh Volume: 397.3 mL (+5.7%)

Metric 3D Reconstructed Mesh

Fig. 1: Our method builds a metrically accurate watertight mesh of a plated food item from two full arcs of head motion around the plate. The true physical scale of the item is recovered entirely from the stereo cameras' calibration and on-device pose estimation. No reference object or user-provided dimension is used at any stage.

approaches based on egocentric vision [3, 12, 13]. Egocentric videos from wearables can capture natural eating scenes, potentially unlocking passive dietary monitoring; however, this shift will only prove to be useful if data provided by wearables (such as known camera calibrations and estimated poses) is uniquely harnessed to estimate true metric scale of food items without a substantial user burden. To this end, we propose a method that leverages stereo videos captured on the egocentric wearable Project Aria Gen 2 glasses [8] to estimate the volume of plated food items without any reference objects required in the scene.

Our method runs end-to-end on recorded videos where the wearer “scans” a plated food item, utilizing FoundationStereo [14] for zero-shot metric-scale depth estimation and SAM 2 [10] for food mask segmentation over a set of keyframes. A 3D mesh of the food item is extracted using truncated signed distance function (TSDF) fusion [1] over a voxel grid representing the shared global coordinate frame; this mesh is metric by construction and requires no further scaling. Our video recording protocol has a relatively high user burden due to the need for a deliberate scanning movement around the plate by the wearer, but the strong volume estimation results from our experiments demonstrate the viability of our approach as a step towards passive dietary monitoring. The contributions of this paper can be summarized as follows:

– A generalizable method to extract metric-scale 3D meshes of food items to estimate volume from egocentric stereo videos captured on the Project Aria Gen 2 wearable glasses.

– A pipeline that runs end-to-end on a single recording file following our recording protocol, automatically deriving a watertight mesh even though the contact region between the food and the plate is never observed by the wearer.

– Experiments demonstrating our accurate volume estimations and reconstructions, along with a comparison demonstrating the necessity of stereo depth estimation over monocular metric depth estimation in this approach.

(a) Keyframe Selection and Stereo Rectification

Figure

Fig. 2: Method overview. (a) 40 rectified stereo keyframes spaced evenly across the device trajectory are used as inputs to (b) FoundationStereo. Metric depth maps are computed from the generated dense disparity maps using the stereo baseline and camera intrinsics. (c) Food and plate masks are generated using SAM 2 by leveraging the wearer's gaze on the food in the first keyframe. (d) The depth maps and food masks yield a mesh using traditional TSDF fusion, whose contact region with the plate is unobserved in the camera views, guaranteeing a hole; (e) this hole is filled using the plate plane fitted in the previous stage by clipping the mesh at the plane's surface. All holes are filled via fan triangulation, and the final watertight mesh is integrated to estimate the food's volume.