Abstract

Radiology reports are essential for diagnostic reasoning and patient care, yet their manual preparation is time-consuming and cognitively demanding. Automatic radiology report generation (RRG) offers a scalable alternative, but existing models often produce lengthy, unstructured narratives that overlook diagnostic cues and multi-view information. We present Clinical-Knowledge Guided Disease-aware Visual–Textual Alignment for QA-Style Radiology Report Generation (CliQ-RRG), a unified two-stage framework for interpretable and clinically grounded reporting. In Stage 1, CliQ-RRG employs a Disease-aware Visual–Textual Alignment module that aligns image and text representations using predicted disease embeddings, reinforced by a Prior-Guided Attention Module (PrAM) to capture multi-view dependencies across current and prior scans. In Stage 2, GraphRAG-guided retrieval augments intermediate textual representations with graph-grounded clinical evidence, and a large language model restructures them into concise, interpretable question-answer (QA) pairs with diagnostic summaries. Experiments on two public chest X-ray benchmarks demonstrate that CliQ-RRG consistently outperforms prior methods across both lexical and clinical metrics, generating accurate and clinically coherent QA-style radiology reports. Code is available at https://github.com/chandravardhan-singh-raghaw/CliQ-RRG.

1 Introduction

Radiology report generation (RRG) is vital for chest X-ray (CXR) interpretation, requiring substantial clinical expertise and reasoning (Jin et al., 2024). Manual interpretation, however, remains time-consuming and cognitively demanding, even for experts (Liu et al., 2025a; Park et al., 2025). As imaging volumes rise, radiologists face increasing workload, often affecting report quality and diagnostic accuracy. Consequently, automated RRG has emerged as a promising solution (Hou et al., 2023; Liang et al., 2024; Luo et al., 2024), yet most methods emphasize disease-specific regions, overlooking broader contextual information.

Recent studies have proposed advanced techniques to improve automatic RRG. Li et al. (2024b) integrates graph-enhanced and regional features to describe normal and abnormal findings, yet outputs remain lengthy and less interpretable. To embed clinical knowledge, Hou et al. (2025) and Sun et al. (2025) retrieve domain-specific information, but the generated texts lack diagnostic coherence. Huang et al. (2025) aligns visual and textual features via a cross-modal adapter; however, the approach is inefficient and overlooks supervised labels that strengthen the alignment. Dual-view RRG methods (Chen et al., 2021; Yang et al., 2023) differentiate radiographic views but miss fine anatomical and contextual relations across scans, limiting multi-view consistency in generated reports.

Despite progress in RRG (Zhang et al., 2020b; Yan and Pei, 2022), existing methods face four key limitations (Fig. 1). (G1) Prior works (Jin et al.,

Figure

Figure 1: Comparison with existing methods. Existing approaches generate unstructured reports, overlook prior scans, lack clinical knowledge, and exhibit limited alignment. In contrast, CliQ-RRG generates QA-style reports with clinical knowledge enrichment, disease-aware alignment, and prior-guided attention.

2024; Luo et al., 2024; Wang et al., 2025) generate long free-text narratives, in which key findings are embedded within paragraphs rather than presented in a structured form. Existing studies have limitations of lengthy and inconsistent structured clinical text (Kell et al., 2024; Pattnayak et al., 2025; Schwartz et al., 2011). We therefore explore a QA-style reformulation to make findings explicit and easier to retrieve, aiming to improve structural clarity rather than replace narrative reports. (G2) Many studies (Yan et al., 2023; Bu et al., 2024a; Gu et al., 2024) rely on image–report pairs, which may yield fluent but underspecified descriptions, especially for subtle findings. We incorporate external clinical knowledge at the intermediate stage to promote clinically grounded expressions and strengthen alignment between visual evidence and generated text. (G3) Recent studies (Li et al., 2023; Shen et al., 2024; Xiao et al., 2025) align visual and textual modalities but neglect diagnostic labels as supervisory signals for joint embedding learning, unlike prompt-based approaches (Jin et al., 2024). We integrate predicted diagnostic labels directly into a contrastive alignment objective, structuring the joint visual–textual space based on diagnostic similarity. (G4) While several methods (Hou et al., 2023; Gu et al., 2025; Liu et al., 2025b) leverage historical information, most standard approaches do not explicitly fuse prior scans at the visual representation level. We introduce prior-image fusion before alignment to capture temporal context within the learned feature space.

We present Clinical-Knowledge Guided Disease-aware Visual–Textual Alignment for QA-Style Radiology Report Generation (CliQ-RRG), a unified framework centered on two core contributions: disease-grounded GraphRAG retrieval and fine-tuned LLM-based QA restructuring. As shown in Fig. 1, CliQ-RRG addresses limitations of prior RRG methods. (S1) It reformulates free-text reports into clinically interpretable QA-style outputs. (S2) It injects external clinical knowledge to enable reasoning beyond data-driven correlations. (S3) It aligns visual and textual representations via predicted disease embeddings to achieve semantically grounded features. (S4) It incorporates multi-view information from prior examinations through a prior-guided attention mechanism to enhance contextual understanding. Extensive experiments on MIMIC-CXR and IU X-Ray show that CliQ-RRG consistently outperforms state-of-the-art methods in radiology report generation.

Our main contributions are threefold:

• To the best of our knowledge, CliQ-RRG is the first framework to leverage contrastive alignment for QA-style radiology report generation, restructuring unstructured narratives into concise, structured question-answer pairs.

• We introduce a Disease-aware Visual-Textual Alignment module that aligns image and text representations via predicted disease embeddings, guided by a Prior-Guided Attention Module for multi-view contextual integration.

• We design a GraphRAG-guided generation pipeline that enriches intermediate reports with graph-grounded clinical evidence and employs a large language model to synthesize the final QA-style report.