arXiv:2610.13435cs.LGOct 2026

Manuscript Offprint

arXiv:2610.13435

PPG-Bench: A Unified Benchmark for PPG Foundation Models

Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar

Arvasu Kulkarni

Mannas AI

arvasu@mannas.ai

Mahir Jain

Mannas AI

mahir@mannas.ai

Aditya Ray Mishra

Mannas AI

aditya@mannas.ai

Sandeep Singh

Mannas AI

sandeep@mannas.ai

Siddharth Panwar

Mannas AI

siddharth@mannas.ai

Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task–regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

1 Introduction

Photoplethysmography (PPG) is widely recorded by wearable and clinical devices and supports applications spanning cardiovascular monitoring, activity monitoring, sleep staging, and clinical screening (Charlton et al., 2023; Loh et al., 2022). This has motivated research into PPG foundation models (FMs) intended to provide reusable representations across downstream tasks (Abbaspourazad et al., 2024; Guo et al., 2026; Nie et al., 2026; Pillai et al., 2025; Saha et al., 2025).

However, current PPG FMs are difficult to compare. Their evaluations differ in datasets, task definitions, preprocessing, downstream heads, finetuning procedures, hyperparameter optimization, and baselines. Comparisons between PPG FMs also do not establish whether learned representations improve over conventional physiological features or whether PPG-specific pretraining adds value beyond generic time-series pretraining.

Preprint.

To address these issues, we introduce PPG-Bench, an open-source benchmark that tests five public PPG FMs across nine open-access datasets and 17 primary + 9 secondary tasks. Models are evaluated using linear probes, random forests, frozen MLP probes, and end-to-end finetuning, with model-specific hyperparameter optimization and fully subject-disjoint cross-validation. We compare them against a random/constant baseline, a deterministic pulse-rate-variability (PRV) representation, and MOMENT, a generic time-series FM (Goswami et al., 2024).

Across 68 task–regime combinations (regime meaning the type of evaluation method used), 24 (35.3%) show no meaningful PPG-FM improvement over the random chance baseline, and in 57 (83.8%) no PPG-specific FM outperforms both PRV and MOMENT. These results show that current PPG FMs provide inconsistent gains over simpler alternatives and motivate common, controlled evaluation.

References (39)