Manuscript Offprint

arXiv:2610.13780

Detection of extremely rare dead cells in fluorescence microscopy images

Prateek Verma, Benjamin Butter, Jian Zhang, Xintao Wu

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Prateek Verma 1^{1}, Benjamin Butter 2^{2}, Jian Zhang 2^{2}, Xintao Wu 1^{1}

1^{1}Department of Electrical Engineering and Computer Science

2^{2}Department of Biomedical Engineering

University of Arkansas, Fayetteville, Arkansas, USA

{prateek, bbutter, jianz, xintaowu} @ uark.edu

Abstract—Dead cell detection in fluorescence microscopy is essential for phenotypic screening and drug efficacy assessment. However, automated identification remains challenging due to signal variability, optical artifacts, and colocalization ambiguities across multiple channels. Markers/stains that define nuclear boundaries do not neatly, in practice, coincide spatially or temporally with apoptotic markers. Furthermore, marker accumulation kinetics vary across individual cells and apoptosis stages, making universal thresholds unreliable. We present a systematic comparison of several computational approaches for detecting apoptotic cells in nucleus-stained specimens: (1) heuristic methods using intensity thresholds, distributions, correlations, and domain guidance; (2) classification using both numerical features (Logistic Regression, Random Forest, XGBoost and LightGBM) and image features (ResNet-18 and EfficientNet-B0); and (3) anomaly detection, also using both numerical features (Isolation Forest, one-class SVM and PCA reconstruction) and image features (convolutional autoencoders and Deep SVDD). Using a dataset of 258 images containing 65,527 cells/nuclei across multiple scenes with 243 manually annotated ground truth dead cells, we evaluate each method on metrics such as PR-AUC, Precision, Recall, F1-score, and macro-F1. Our results indicate that classification using image features (deep learning) and numerical features (traditional) achieved the best performance, with ResNet-18 and XGBoost significantly outperforming manually designed heuristics and anomaly detection methods. Our findings demonstrate that such biomedical problems remain highly challenging to solve even with the state-of-the-art computational and learning techniques. We aim to provide an effective decision-support tool to researchers while tackling such problems either fully-automatically or in a human-in-the-loop setting as an aide to domain scientists.

Index Terms—dead cell detection, apoptotis, machine learning, anomaly detection, heuristic pipeline

I. INTRODUCTION

Cell viability assessment is critical across multiple biomedical disciplines, including drug discovery, toxicology, and regenerative medicine. Manual inspection of apoptotic markers in fluorescence microscopy images is time-consuming, subjective, and impractical for high-throughput screening campaigns. A primary approach to dead cell detection leverages colocalization of nuclear and apoptotic markers. The hypothesis is that apoptotic cells accumulate specific fluorophores in the nucleus region (typically marked by a blue DNA stain like Hoechst or DAPI); detecting simultaneous enrichment in both channels provides specificity [1]-[3].

To identify dead cells, domain scientists visually inspect the colocalization of fluorescence signals, paying close attention when a green apoptosis signal (like that from YO-PRO-1) overlaps with a nucleus identified by the blue channel (like that from Hoechst). Hoechst works by staining DNA in the nuclei of healthy cells and YO-PRO-1 by penetrating the cell membrane of dying cells and staining the double stranded nucleic acids. Because of the underlying biological mechanics, a valid target signal must match the morphology of the nuclear topology, meaning any hyper-intensity that does not follow the nuclear shape is discarded as noise or stained cell debris [1]. A secondary apoptosis signal from a red channel (like that from Propidium Iodide or simply, PI) provides a good confirmation to confidently “double-check” these dead cells; PI works by slipping between DNA base pairs (intercalation) for already dead or damaged cells. The green channel remains the primary driver of classification because its dye stains slightly earlier in the apoptotic cascade, catching cells that have not yet accumulated the red marker [2]. Translating this expert manual protocol into an automated pipeline, however, introduces severe computational challenges. The problem is characterized by an extreme class imbalance where dead cells represent a tiny fraction of the population [4]. It is further complicated by imperfect segmentation, manual annotation limits, image-to-image variations, and staining artifacts making it highly difficult for rigid algorithms to reliably separate valid apoptotic signals from background noise.

We systematically evaluated three computational families for detecting apoptotic cells in a curated dataset with expert-annotated ground truth. First, heuristic based methods used simple intensity thresholds (based on percentile, bimodality or z-score), adaptive intensity gap detection algorithm to identify the natural separation between live and dead cell populations, Pearson Correlation or normalization between nuclear and apoptotic marker channels as a colocalization check, and eventually a domain-knowledge incorporated pipeline that aimed to remove blotchy/bright and edge stain artifacts and use red channel for confirmation only [5]–[7]. Second, traditional classification models (Logistic Regression [8], Balanced Random Forest [9], XGBoost [10], and LightGBM [11]) were trained on numerical features extracted from Cellpose segmentation masks and square image patches centered at the segmented nuclear centroids. Deep learning

Figure

Fig. 1. An illustration of the computational approaches used in the automation pipeline.

approach utilized ResNet-18 [12] and EfficientNet-B0 [13] architectures on the same image patches, using three-channel inputs (blue/nucleus, green/apoptotic marker, red/confirmation marker). Finally, anomaly detection methods, using both numerical features (Isolation Forest [14], one-class SVM [15], PCA reconstruction [16]) and image features (convolutional autoencoders [17] and Deep SVDD [18]) were trained exclusively on live cells to identify out-of-distribution samples as potential dead cells.

Our acquired dataset consisted of 112,011 segmented cells across 766 images, with 258 images having expert-annotated ground truth. Manual annotation provided 243 dead cell labels and 65,284 remaining cells classified as alive. For learning-based approaches, the data was partitioned into an 80/20 train/test split, where decision thresholds for classification models were optimized using group-aware five-fold cross-validation on the training set. Heuristic and anomaly detection approaches were applied to identical data scopes using prevalence-informed or image-specific criteria described in their respective sections. Performance across all families is uniformly reported on the evaluation partition using PR-AUC (where applicable), Precision, Recall, F1-score, and macro-F1 as primary metrics [4], [19], [20].

References (44)