arXiv:2610.13853cs.CROct 2026

Manuscript Offprint

arXiv:2610.13853

Decision-Focused Learning for Cyber-Physical Risk-Aware Power Grid Operations

Ayesha Siddiqua Dina, Ebisa D. Wollega, Afzal Hossain Sohag

Afzal Hossain Sohag

Department of Computer Science

Florida Polytechnic University

Lakeland, FL, USA

asohag3061@floridapoly.edu

Ayesha S. Dina

Department of Computer Science

Florida Polytechnic University

Lakeland, FL, USA

adina@floridapoly.edu

Ebisa D. Wollega

Department of Industrial Engineering

Florida Polytechnic University

Lakeland, FL, USA

ewollega@floridapoly.edu

Abstract—Power grid cyber-physical security requires intrusion detection methods that account for the operational consequences of detection errors. However, the existing intrusion detection approaches primarily focus on the predictive performance of learning algorithms, while downstream operational costs are often optimized independently, which can lead to inferior operational performance. To help alleviate this problem, we propose a novel optimization-learning cyber-physical-risk-informed framework that communicates iteratively to minimize power grid operational costs. This framework translates machine learning prediction errors into power grid operational cyber-physical-risk costs. Experimental results on two power grid operation datasets, Industrial Control System (ICS) Cyber Attack and Sherlock, show that the proposed approach improves power grid operation costs compared with the traditional approach.

Index Terms—Intrusion Detection, Decision-Focused Learning, Cyber-Physical-Risk, Power Grid Operations.

This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible.

I. INTRODUCTION

Modern power systems are evolving into highly interconnected smart grids that integrate communication, automation, distributed energy resources, and real-time monitoring. The increased deployment of sensors, smart meters, supervisory control and data acquisition (SCADA) systems, and intelligent control devices has significantly improved operational efficiency, reliability, and energy management capabilities. However, this digitalization also introduces security challenges because power grid operation increasingly depends on communication networks and cyber-physical interactions [1][1], [2][2].

Unlike conventional isolated power systems, power grids continuously exchange operational information among generators, substations, control centers, and consumers. This interconnection increases exposure to cyber-physical threats such as false data injection (FDI), denial-of-service (DoS), malware, and communication tampering [3], [4]. Existing studies have shown that attackers can manipulate sensor measurements or communication signals to disrupt state estimation, destabilize system operation, and interfere with economic dispatch procedures [3], [5], [6]. Such intrusions can cause poor operational decisions, financial losses, cascading failures, and service interruptions. Among these threats, FDI attacks are a major cybersecurity risk in modern smart grids [3], [4]. Because operational decisions rely on accurate state estimation and real-time measurements, compromised data can directly affect generator scheduling, load balancing, and grid optimization.

To mitigate these risks, several cyber-physical security solutions have been proposed, including intrusion detection systems (IDSs), anomaly detection, encryption, and secure communication architectures [1], [2], [4]. Machine learning-based intrusion detection approaches can identify complex attack patterns and abnormal behaviors in cyber-physical environments, including suspicious measurements in substation communication systems [7]–[10]. Existing studies have investigated supervised learning, unsupervised learning, and process-aware intrusion detection methods for detecting cyber-physical attacks in power grid systems [7], [8], [11]. Although these approaches have demonstrated promising detection performance, many existing methods primarily optimize predictive metrics such as accuracy, recall, precision, and F1-score without considering the downstream operational cost of prediction errors on power system decision-making.

Significant research has also been conducted on resilient economic dispatch, robust optimization, and secure operational planning under attacks and uncertain operating conditions [6], [12]. Integrity and FDI attacks can destabilize dispatch decisions and disrupt electricity market operation [3], [5], [6]. Robust optimization approaches have been proposed to improve reliability and robustness in power systems [12]. However, existing studies have investigated cyber-physical attack detection and resilient economic dispatch, with comparatively less emphasis on how detection errors translate into operational cost [13]–[15].

Decision-focused learning framework integrates machine learning with downstream optimization objectives [16]–[19]. Unlike traditional predict-then-optimize pipelines, these approaches directly optimize decision quality rather than prediction accuracy alone. Although decision-focused learning has shown promise in operational optimization, limited research has integrated cyber-physical-risk-aware intrusion detection, and power grid operations optimization.

To address these limitations, this paper proposes a cyber-physical-risk-aware intrusion detection and power grid opti-mization framework for cyber-physical power systems. The proposed framework integrates machine learning-based intrusion detection with power grid operational optimization by transforming intrusion detection misclassification outcomes into generator-level cyber-physical-risk costs that guide power grid operational planning. Unlike traditional intrusion detection systems that primarily evaluate predictive performance, the proposed framework incorporates asymmetric misclassification penalties to represent the different operational consequences of false positives and false negatives within the power grid optimization.

The framework is evaluated on two benchmark cyber-physical power-system datasets to examine the relationship between intrusion detection performance and operational cost. The main contributions of this work are summarized as follows:

• Development of an optimization-informed cyber-physical-risk framework that integrates machine learning-based intrusion detection with power grid operational optimization.

• Transformation of intrusion detection misclassification outcomes into generator-level cyber-physical-risk costs for power grid operational optimization.

• Development of an iterative feature-reweighting mechanism that uses learned IDS parameters to update the feature representation for subsequent IDS retraining.

• An evaluation of intrusion detection performance and operational cost on two benchmark cyber-physical power-system datasets with different grid topologies and attack scenarios.

References (23)