Manuscript Offprint
arXiv:2610.11312MedBenchAgent: Towards Systematic Automation of Medical VLM Benchmark Construction
ABSTRACT
Large-scale construction of medical vision-language model (VLM) benchmarks is increasingly feasible with richly annotated imaging datasets and large language models (LLMs), yet existing automation largely focuses on generating evaluation items within predefined benchmark specifications. We study the broader problem of automatically deriving the specification itself: what to evaluate, which annotations support each task, and how to translate this evidence into reliable evaluation items. We formulate benchmark construction as constrained compilation, in which the benchmark specification is progressively derived from evaluation requirements, heterogeneous annotations, and medical knowledge. Based on this formulation, we introduce MedBenchAgent, a multi-agent framework with a Benchmark Intermediate Representation (BIR) that encodes task definitions, evidence mappings, evaluation protocols, and item specifications across construction stages. MedBenchAgent separates planning, which derives and verifies the specification, from instantiation, which constructs and audits items under the locked specification. MedBenchAgent achieves a Task-Space F1 of 90.9%, outperforming direct task induction (79.2–80.0%) and prior-guided induction (85.1%); 994 of 1,000 sampled items from correctly identified tasks pass human audit. We further demonstrate portability to a specialized medical domain and evaluate twelve VLMs, revealing task- and setting-specific variation obscured by aggregate scores. These results establish constrained compilation as a scalable and auditable framework for medical VLM benchmark construction beyond question generation.
1 INTRODUCTION
Large-scale construction of medical vision-language model (VLM) benchmarks is increasingly feasible as richly annotated imaging datasets provide reusable supervision and large language models (LLMs) enable scalable generation of evaluation items (Zhang et al., 2023; Hu et al., 2024; Chen et al., 2024). Yet a benchmark is more than a collection of images and questions: it must specify what capabilities are evaluated, which source annotations validly support them, how annotation evidence is transformed into reference answers, how evaluation items are instantiated, and how model responses are elicited and assessed. Collectively, we refer to these decisions as the benchmark specification, which in turn determines the claims that the resulting evaluation can support. In medical imaging, establishing such a specification requires interpreting heterogeneous annotation schemas, units, terminology, and label semantics, making manual benchmark design time-consuming and expertise-intensive. Automating the specification itself, rather than only large-scale item generation, is therefore an important problem for scalable and reliable medical VLM evaluation.
Existing work approaches automated benchmark construction from two directions. Medical systems construct benchmarks from domain data, but operate within predefined clinical scopes, reporting structures, or question schemas (Xie et al., 2026; Liu et al., 2026a). General-purpose systems offer greater flexibility by using declarative or agentic workflows to translate evaluation requirements into benchmark construction (Li et al., 2025; Xiong et al., 2026; Butt et al., 2025). However, they do not explicitly constrain medical benchmark specification by annotation-supported task validity, reference provenance, and medical knowledge. The remaining challenge, then, is to combine flexible benchmark specification with the semantic and evidential constraints imposed by evaluation requirements and heterogeneous medical data.
We address this challenge with MedBenchAgent, a multi-agent framework for systematic medical VLM benchmark construction. We cast benchmark construction as constrained compilation, in which the benchmark specification is progressively established from an intended evaluation scope, heterogeneous source annotations, and medical knowledge, with each confirmed decision narrowing the space of subsequent construction. To make these constraints explicit and preserve them across stages, we introduce a Benchmark Intermediate Representation (BIR) that records the evaluation scope, task hierarchy, annotation evidence mappings, evaluation protocols, sample allocations, and item-construction specifications. Together, constrained compilation and the BIR provide an explicit mechanism for carrying semantic and evidential constraints from benchmark specification into downstream construction. MedBenchAgent operationalizes this formulation through a staged multi-agent workflow for medical benchmark construction: 1) planning resolves and verifies the specification against dataset annotations and medical references before locking the BIR; and 2) instantiation constructs and audits evaluation items under this fixed specification. In this way, MedBenchAgent extends automation from predefined medical scopes or question structures to benchmark specification itself, while preserving the annotation and medical constraints required for reliable construction.
This formulation enables empirical evaluation of both the benchmark-construction process and the benchmark produced by MedBenchAgent. In construction analysis, MedBenchAgent achieves a Task-Space F1 of 90.9%, compared with 79.2–80.0% for direct task induction and 85.1% when the same task prior is provided to the direct model. For correctly identified tasks, 994 of 1,000 sampled items pass human audit. Together, these results suggest that open-ended decisions about what should be evaluated are substantially more challenging than evidence mapping and item construction once benchmark semantics are constrained. We further instantiate the workflow in a specialized medical domain under a different annotation schema and evaluate twelve VLMs on the resulting benchmark. Model evaluation reveals substantial variation across tasks, imaging settings, and evaluation metrics that aggregate scores can obscure, reinforcing fine-grained benchmark specification as an important component of medical VLM evaluation.
Overall, this work makes three contributions: (1) Conceptually, we model the construction of medical VLM benchmarks and formulate it as constrained compilation; (2) Methodologically, we introduce a multi-agent MedBenchAgent framework and its Benchmark Intermediate Representation (BIR); and (3) Empirically, we derive insights into both the benchmark-construction process and medical VLM evaluation, while providing reusable benchmark artifacts.
Automated benchmark construction. General-purpose benchmark automation has increasingly adopted declarative or agentic construction, whereas medical systems have favored domain-specific, more deterministic workflows. AutoBencher constructs benchmarks from specified evaluation desiderata, BenchmarkAgent translates high-level evaluation requirements into construction procedures, and BenchAgents coordinates multiple agents across benchmark-creation stages (Li et al., 2025; Xiong et al., 2026; Butt et al., 2025). In the medical domain, EHRBench uses a task-specific template pipeline to instantiate clinical QA from EHR data (Xie et al., 2026), while Liu et al. (2026a) packages schema- and report-grounded oncology VQA generation as a reusable agent skill.
3 WHAT MAKES A GOOD MEDICAL VLM BENCHMARK?
3.1 BENCHMARK FORMULATION
A medical VLM benchmark must specify both what is evaluated and how model performance is assessed. Building on medical benchmarking frameworks that distinguish the evaluation objective, challenge data, reference annotations, and assessment procedures (Karargyris et al., 2023; Maier-Hein et al., 2020), and following recent task-oriented medical VLM benchmarks, we additionally specify the task definitions and queries presented to the model for vision–language evaluation. We represent a benchmark by its intended evaluation scope U, task space T, evaluation-item set I, and evaluation protocol P. A medical VLM benchmark is therefore defined as
where is a medical imaging case, the evaluated task, the model-facing query, and the benchmark reference; specifies each task's response convention and scoring rule.
Because each is a benchmark-level reference, not a raw annotation copied directly from a source dataset, its provenance and semantics must be recorded. The CLAIM guideline requires medical imaging studies to document the source, definition, and acquisition procedure of the reference standard (Tejani et al., 2024). We represent the source datasets as
where is the set of imaging cases in dataset , is its annotation collection, and specifies the annotation schema, annotation unit, granularity, label space, and field semantics. An annotation record represents evidence encoded under the dataset-specific specification ; it becomes a benchmark reference only after its semantics have been matched to a task and mapped into the common benchmark representation.
Benchmark construction must therefore determine not only whether the available annotations support a proposed task, but also how the relevant annotation evidence should be interpreted as its reference answer. We therefore abstract benchmark construction as
where K denotes the medical knowledge required to interpret clinical concepts and evaluation semantics. Once constructed, the benchmark can be applied to a model set M to produce empirical evidence . This separates benchmark construction, which defines the evaluation object, from benchmark application, which produces evidence about model behavior under the specified scope and protocol. We use benchmark specification to denote the pre-instantiation decisions that determine the evaluation scope, dataset-specific task definitions and granularity, supporting evidence and reference construction, evaluation protocol, sample allocation, and item-construction rules. The concrete item set I is produced by instantiating this specification over the source cases.
3.2 DESIDERATA FOR BENCHMARK CONSTRUCTION
The formulation above motivates three desiderata for medical VLM benchmark construction.
D1: Evidence Groundedness. Because benchmark construction maps source annotations to evaluation tasks and reference answers, annotation availability alone is insufficient to justify either output. Evidence groundedness requires that each task be supported by the schema and semantics of its source annotations and that each item-level reference be entailed by the annotation evidence used to construct it. SLAKE uses physician-provided annotations, while EHRXQA uses templates and executable queries (Liu et al., 2021; Bae et al., 2023).
D2: Medical Alignment. Annotation support establishes that a task is constructible, but does not determine how it should be expressed under the intended medical evaluation scope. Medical alignment requires task definitions, response spaces, and queries presented to the model to be consistent with established medical concepts and terminology, and not merely to verbalize labels to one dataset. GMAI-MMBench reflects this desideratum by organizing evaluation around clinically defined tasks (Chen et al., 2024).
Checklist for Artificial Intelligence in Medical Imaging

Figure 1: Overview of MedBenchAgent. MedBenchAgent coordinates five agents through a shared Benchmark Intermediate Representation (BIR). Planning specifies tasks and their constraints within the BIR, whereas instantiation constructs evaluation items under the locked specifications.
D3: Evaluative Utility. The application further implies that evidence-grounded and medically aligned items do not necessarily yield informative evidence about model behavior. Evaluative utility requires the benchmark to support separate assessment of model capabilities and preserve interpretable differences across tasks and imaging settings. OmniMedVQA, MultiMedEval, and GMAI-MMBench exemplify this desideratum through evaluation across multiple datasets, tasks, modalities, and model families (Hu et al., 2024; Royer et al., 2024; Chen et al., 2024).
3.3 BENCHMARK CONSTRUCTION AS CONSTRAINED COMPILATION
We therefore formulate benchmark construction as constrained compilation: planning progressively establishes the benchmark specification, and each confirmed decision restricts the admissible choices of subsequent stages within the mapping . The evaluation scope constrains the relevant task categories; annotation semantics determine which concrete prediction targets can be instantiated within them and which evidence can support their references; medical knowledge and evaluation requirements further constrain task expression and assessment. This process requires an explicit intermediate state that preserves confirmed decisions across stages. Section 4 instantiates this state as the BIR and locks it before item construction.
4 MEDBENCHAGENT
Figure 1 summarizes the five-agent workflow and the separation between planning and instantiation, while Algorithm 1 formalizes the corresponding BIR updates and stage-wise construction procedure.
4.1 INPUTS AND BENCHMARK INTERMEDIATE REPRESENTATION
MedBenchAgent takes three benchmark-specific resources as input: a natural-language user requirement, medical imaging datasets, and medical reference materials. Each dataset-specific BIR contains a task-category prior , represented as an unexpanded task tree. The user requirement defines the intended evaluation scope and specifies additional user constraints on benchmark construction. The source collection consists of medical imaging cases and their dataset-specific annotations. The medical knowledge resource consists of clinical guidelines, reporting standards, and other domain references relevant to the target setting. The initial task definitions in are distilled from the task-design principles of existing medical VLM benchmarks and specify candidate tasks and their annotation-support conditions.
Section 3 formulates benchmark construction as . MedBenchAgent implements this transformation through two coupled stages:
where Z denotes the benchmark design produced during planning.
For each source dataset , planning maintains a dataset-specific Benchmark Intermediate Representation (BIR). After the evaluation scope is confirmed, its task-space component is initialized as the unexpanded task tree . Candidate nodes are retained, removed, or expanded according to their support conditions, the evaluation scope, and available annotation evidence. Planning completes their evidence mappings, evaluation protocols, and sample allocations, while task design supplies the item-construction specifications. The resulting state is then confirmed and locked:
Here, is the dataset-specific task tree obtained by retaining supported nodes and expanding decomposable tasks into distinct prediction targets. Ordinary tasks remain leaf nodes, whereas decomposable tasks have question types as their children. Each child must remain within its parent's task semantics and have annotation support for its own prediction target. The middle four components jointly describe this tree and its node specifications: records supporting annotation evidence, specifies the evaluation protocol, and denotes the sample allocation associated with task node . These specifications are completed for the retained atomic tasks during planning; the zero entries in the initial BIR denote components not yet populated for the dataset. contains the corresponding medically grounded item-construction specification. We write Leaves( ) for the retained atomic evaluation tasks, so a decomposable parent is not counted in addition to its children.
The planning output is therefore . Each encodes the confirmed dataset-level benchmark specification, while instantiation produces the corresponding audited item set . Dataset-specific leaf tasks, item sets, and protocols are then consolidated across datasets, with , to form the final benchmark .
4.2 PLANNING: COMPILING AND LOCKING THE BIR
Planning implements via SpecificationAgent, TaskPlanningAgent, and MedicalAlignAgent, which structure requirements, determine supported tasks, and design task items, respectively. The CKPT markers in Algorithm 1 denote critical verification checkpoints at consequential planning transitions, validating the proposed BIR state before commitment through deterministic checks, human review, model-based supervision, or hybrid mechanisms.
SpecificationAgent first converts the open-ended natural-language requirement u into a structured evaluation scope U. The specification resolves ambiguous dimensions of the requested benchmark before constraining subsequent planning.
TaskPlanningAgent then extends the task-category prior into the dataset-specific task tree using the evaluation scope and annotation evidence in . A category is retained only when its support conditions are satisfied, and records the eligible annotation fields to construct references for its tasks. When annotations expose multiple distinct prediction targets within a supported task, the agent expands it into child tasks, each representing an annotation-supported an-
Algorithm 1 Medical VLM benchmark construction
Require: User requirement u, source datasets D, medical references K Ensure: Benchmark
1: ; ;
2: for all do
3:
4:
5:
6:
7: for all eligible case-task pairs with do
8:
9:
10:
11:
12: if REVIEWITEM( , ) then
13: end for
14:
15:
16: end for
17: ;
18: return
swer axis within parent semantics. Semantic duplicates are removed across retained atomic tasks,

Figure 2: Benchmark construction and representative items. Three source datasets are mapped through heterogeneous annotations to the retained evaluation tasks, with one representative item shown for each task. Numbers in parentheses denote item counts.
establishing the task support required by Desideratum D1. TaskPlanningAgent selects a compatible primary evaluation metric for each retained atomic task. The resulting task plan passes through CKPT before commitment to the BIR, after which deterministic allocation assigns . Preserving prediction targets provides the basis for separate task-level analysis under Desideratum D3.
MedicalAlignAgent subsequently converts each retained task into a medically meaningful and executable item-construction specification . It adopts retrieval-augmented generation (RAG) (Lewis et al., 2020) over the relevant medical references in to ground the design in medical knowledge. Grounded on these references and constrained by the retained task semantics and authorized annotation evidence, it specifies the task's question semantics, response space, and reusable question formulations, together with the normalization to benchmark-level reference answers. This step connects an evidence-supported task to its medical evaluation semantics, thereby supporting Desideratum D2. After the complete set of task designs passes through CKPT, the resulting is fixed for downstream instantiation. Downstream stages may read the confirmed task definitions, supporting evidence, protocols, sample allocations, and construction specifications, but cannot revise them.
4.3 INSTANTIATION: CONSTRUCTING ITEMS UNDER THE LOCKED BIR
Instantiation realizes in Eq. 4 by applying to the source annotations without reopening the confirmed benchmark design. As summarized in Algorithm 1, GenerationAgent operates at the case–task level to instantiate evaluation items, whereas AuditAgent operates over the resulting item set to verify benchmark-level consistency.
For each eligible case–task pair with , GenerationAgent constructs an evaluation item under the corresponding task specification . The model generates only the query , varying its wording within the locked task semantics and authorized annotation evidence. Deterministic code derives the reference answer from the supporting evidence specified by and, where applicable, organizes the response options according to the confirmed construction specification. A subsequent model review call screens the generated item for task drift, ambiguity, unsupported additions, and answer leakage without modifying the fixed reference. This separation allows linguistic variation in the query while preserving annotation-grounded reference answers and the item-level entailment requirement of Desideratum D1.
AuditAgent subsequently checks the generated item set for consistency with the locked task-node specifications, source annotations, and benchmark-level requirements. Deterministic checks verify annotation support, response and reference consistency, and exact duplication, while accepted multiple-choice items are balanced with respect to option positions. AuditAgent additionally performs task-stratified consistency screening to identify issues such as task drift, answer leakage, ambiguity, and semantic duplication. The items passing the deterministic audit constitute the finalized evaluation-item set I and complete the resulting benchmark .
Table 1: Task-space construction and evidence-mapping results. Task-Space Precision (P), Recall (R), and F1 measure agreement with researcher review; EMA measures agreement of supporting annotation fields (%).
| Model | Task-Space Review | Evidence | |||||
|---|---|---|---|---|---|---|---|
| TP | FP | FN | P↑ | R↑ | F1↑ | EMA↑ | |
| DeepSeek-V4-Flash | 19 | 8 | 2 | 70.4 | 90.5 | 79.2 | 100.0 |
| Qwen3.5-9B | 19 | 8 | 2 | 70.4 | 90.5 | 79.2 | 100.0 |
| MedGemma-27B | 20 | 9 | 1 | 69.0 | 95.2 | 80.0 | 100.0 |
| DeepSeek-V4-Flash + | 20 | 6 | 1 | 76.9 | 95.2 | 85.1 | 100.0 |
| MedBenchAgent | 20 | 3 | 1 | 87.0 | 95.2 | 90.9 | 100.0 |
Table 2: Human consistency audit of finalized items. Pass rates are computed over 1,000 items sampled uniformly from the finalized benchmark.
| Criterion | Pass | Fail | Pass Rate |
|---|---|---|---|
| Reference groundedness | 1,000 | 0 | 100.0% |
| Task-query alignment | 996 | 4 | 99.6% |
| Unambiguity | 1,000 | 0 | 100.0% |
| Evaluation integrity | 994 | 6 | 99.4% |
| All criteria | 994 | 6 | 99.4% |
5 EXPERIMENTS: BENCHMARK CONSTRUCTION AND EVALUATION
5.1 EXPERIMENTAL SETUP
Construction. Figure 2 summarizes the resulting benchmark construction. We instantiate MedBenchAgent using three medical imaging datasets: VinDr-Mammo (Nguyen et al., 2023), BrEaST (Pawłowska et al., 2024), and BUS-BRA (Gómez-Flores et al., 2024). The medical knowledge resource is grounded in the relevant sections of the ACR BI-RADS v2025 Manual (Destounis et al., 2025; Leung et al., 2025). For the reported runs, we instantiate the planning checkpoints with researcher review.
Evaluation. We evaluate twelve VLMs spanning general-purpose and medical-domain model families, multiple parameter scales, and different inference regimes. The general-purpose models include InternVL3-8B (Zhu et al., 2025), Qwen2.5-VL (7B, 32B) (Bai et al., 2025), and Qwen3-VL (8B, 32B), including an 8B thinking variant (Qwen Team, 2025). The medical models include MedGemma-4B (Google Research & Google DeepMind, 2025), Lingshu (7B, 32B) (LASA Team et al., 2025), Hulu-Med-7B (Jiang et al., 2025), QoQ-Med-7B (Dai et al., 2025), and BreastGPT-8B (Liu et al., 2026b). Multiple-choice tasks are evaluated with Accuracy (Acc.) and Macro-F1 (F1), while spatial tasks use mean intersection over union (mIoU) and Acc@IoU . When a task contains multiple fine-grained tasks, metrics are computed separately and macro-averaged with equal weight.
Implementation. We host DeepSeek-V4-Flash (DeepSeek-AI, 2026) as the language-model backend with vLLM (Kwon et al., 2023), and Qwen3-Embedding-0.6B and Qwen3-Reranker-0.6B (Zhang et al., 2025) for retrieval and reranking. Model evaluation uses deterministic decoding and FlashAttention-2 (Dao, 2024), and all experiments are run on NVIDIA B200 GPUs.
5.2 BENCHMARK CONSTRUCTION ANALYSIS
Task-space construction. MedBenchAgent uses BIR-mediated task planning to constrain task-space construction with and , rather than inducing the task space in a single open-ended step. We evaluate this strategy against direct baselines using the same inputs in a single model call, and additionally provide DeepSeek-V4-Flash with the initial task definitions . The direct baselines use MedGemma-27B (Google Research & Google DeepMind, 2025), Qwen3.5-9B (Qwen Team, 2026), and DeepSeek-V4-Flash. We evaluate against a reference task space , defined before MedBenchAgent and finalized prior to these experiments by dataset-familiar researchers with informal input from a clinical collaborator. Proposals are matched to by prediction target and annotation semantics rather than surface wording. We report Task-Space Precision, Recall, and F1 from TP, FP, and FN counts; for matched tasks, Evidence-Mapping Agreement (EMA) measures agreement with researcher-confirmed supporting fields. As shown in Table 1, BIR-mediated construction achieves Task-Space F1, compared with for direct induction. Providing improves direct DeepSeek-V4-Flash induction to F1, while MedBenchAgent further increases precision from to at the same recall, reducing false positives from six to three. All methods achieve EMA on matched tasks. These results show that the BIR-mediated design primarily improves the selection of valid prediction targets, while supporting-field identification is reliable once the task is correctly identified.
Table 3: Evaluation performance on tasks with choices. Results are reported as Accuracy / Macro-F1 (%). † denotes thinking variants. Task abbreviations (AA, FT, etc.) are defined in Figure 2.
| Model | Anatomy | Finding | Assessment & Diagnosis | Overall | |||
|---|---|---|---|---|---|---|---|
| AA | FT | FA | AC | DX | PS | ||
| General-purpose VLMs | |||||||
| InternVL3-8B | 36.59/17.30 | 19.09/8.65 | 42.28/30.86 | 16.12/12.82 | 35.35/22.86 | 48.95/40.25 | 33.06/22.12 |
| Qwen2.5-VL-7B | 48.86/23.08 | 29.77/10.17 | 41.45/29.28 | 21.35/11.93 | 33.76/22.67 | 51.03/41.86 | 37.70/23.16 |
| Qwen3-VL-8B-I | 34.89/18.56 | 16.31/9.03 | 29.84/22.57 | 39.11/19.74 | 39.98/29.65 | 60.55/47.85 | 36.78/24.57 |
| Qwen3-VL-8B-T | 25.52/14.18 | 15.09/7.29 | 56.93/35.13 | 38.58/20.03 | 35.13/24.15 | 53.05/42.52 | 37.38/23.88 |
| Qwen2.5-VL-32B | 44.68/21.59 | 54.00/12.67 | 46.20/29.55 | 26.83/16.79 | 43.26/26.69 | 52.92/42.41 | 44.65/24.95 |
| Qwen3-VL-32B | 37.31/20.47 | 54.65/13.25 | 37.08/28.42 | 34.22/20.59 | 39.37/29.83 | 59.37/54.28 | 43.67/27.81 |
| Medical VLMs | |||||||
| MedGemma-4B | 22.39/15.69 | 23.16/10.84 | 47.55/33.94 | 17.98/15.38 | 30.20/23.75 | 55.78/44.32 | 32.84/23.99 |
| Lingshu-7B | 44.27/26.13 | 32.22/12.28 | 56.84/38.66 | 25.28/20.85 | 52.18/29.29 | 71.21/52.53 | 47.00/29.96 |
| Hulu-Med-7B | 31.62/16.63 | 17.05/9.19 | 51.14/35.49 | 22.75/18.81 | 49.64/34.70 | 64.14/51.59 | 39.39/27.73 |
| QoQ-Med-7B | 48.56/22.72 | 53.83/12.03 | 66.09/37.85 | 20.43/10.24 | 41.45/24.07 | 42.14/30.44 | 45.42/22.89 |
| BreastGPT-8B | 36.03/26.41 | 35.73/16.96 | 75.22/52.50 | 40.72/31.54 | 65.09/47.06 | 78.58/71.30 | 55.23/40.96 |
| Lingshu-32B | 50.89/24.70 | 42.66/14.17 | 57.54/43.01 | 34.19/21.65 | 49.04/24.54 | 70.08/55.25 | 50.73/30.55 |
| Family-level Summary | |||||||
| General-purpose Avg. | 37.98/19.19 | 31.49/10.18 | 42.30/29.30 | 29.37/16.98 | 37.81/25.97 | 54.31/44.86 | 38.87/24.41 |
| Medical Avg. | 38.96/22.04 | 34.11/12.58 | 59.06/40.24 | 26.89/19.74 | 47.93/30.57 | 63.65/50.90 | 45.10/29.35 |
Human audit of finalized items. MedBenchAgent promotes consistent item construction by locking item-construction requirements in the confirmed specification before instantiation. To assess whether these constraints are preserved in the finalized benchmark, we sample 1,000 items without replacement and audit each for reference groundedness, task–query alignment, unambiguity, and evaluation integrity against its annotation evidence and specification. An item passes only when all four criteria are satisfied. Table 2 shows that 994 items pass, yielding a 99.4% consistency rate. Six failures include four VinDr-Mammo finding-type questions that ask for BI-RADS assessment categories and two BrEaST diagnosis questions with unsupported additions. These cases localize remaining errors to template semantics and evidence control during generation, distinguishing item-expression errors from the task-specification errors identified in the task-space analysis. The high consistency rate supports locked specifications for large-scale item construction while identifying targets for semantic verification. Detailed setups and additional analyses are provided in Appendix B.
5.3 MODEL EVALUATION
Task-oriented specification preserves non-redundant evaluation evidence. MedBenchAgent retains annotation-supported prediction targets as separate tasks and records their evaluation protocols in the BIR. We test whether these choices affect model assessment beyond increasing benchmark granularity. As shown in Table 3, medical VLMs outperform general-purpose VLMs by 6.23 points in Overall Acc. but trail by 2.48 points on AC, indicating that the aggregate advantage is not uniform across tasks. To quantify such changes, we compare all 66 model pairs and find that 12–24 pairs (18.2–36.4%) reverse ordering between Overall Acc. and individual-task Acc.; within tasks, 4–15 pairs (6.1–22.7%) reverse between Acc. and F1.
Table 4: Spatial localization performance. Results are reported as mIoU / Acc@IoU (%).
| Model | VinDr-Mammo | BUS-BRA | |
|---|---|---|---|
| Det | VG | Det | |
| General-purpose VLMs | |||
| InternVL3-8B | 3.30/0.24 | 3.15/0.33 | 26.00/11.20 |
| Qwen2.5-VL-7B | 7.60/3.91 | 8.77/6.51 | 28.94/22.24 |
| Qwen3-VL-8B-I | 10.72/7.00 | 13.68/10.98 | 51.11/56.40 |
| Qwen3-VL-8B-T | 10.94/7.32 | 10.42/7.00 | 37.50/32.88 |
| Qwen2.5-VL-32B | 9.70/6.10 | 10.83/7.32 | 40.63/37.52 |
| Qwen3-VL-32B | 15.40/12.86 | 18.01/16.84 | 55.36/62.08 |
| Medical VLMs | |||
| MedGemma-4B | 1.54/0.00 | 1.57/0.00 | 15.73/3.68 |
| Lingshu-7B | 4.41/0.81 | 3.65/0.65 | 4.71/0.88 |
| Hulu-Med-7B | 0.01/0.00 | 0.00/0.00 | 6.97/2.96 |
| QoQ-Med-7B | 6.97/1.06 | 6.97/1.30 | 45.63/43.52 |
| BreastGPT-8B | 5.34/0.90 | 5.44/1.14 | 72.62/82.80 |
| Lingshu-32B | 4.70/1.46 | 5.62/1.95 | 12.46/4.40 |
MedBenchAgent also preserves localization annotations as spatial prediction targets rather than converting them into choice-based questions. For example, Lingshu-7B has higher Overall Acc. than Qwen2.5-VL-32B (47.00% vs. 44.65%), while Qwen2.5-VL-32B performs better on all six spatial measures in Table 4. Across these measures, 28–34 of 66 model pairs (42.4–51.5%) reverse
Table 5: Multiple-choice performance under the blurred-image intervention. Results are reported as Acc. / F1 (%). Overall denotes the original-to-blurred score drop (pp)
| Model | Anatomy | Finding | Assessment & Diagnosis | Overall | Δ Overall | |||
|---|---|---|---|---|---|---|---|---|
| AA | FT | FA | AC | DX | PS | Acc/F1 | Acc/F1 | |
| Random Guess | 25.00/20.64 | 12.50/8.02 | 36.90/30.95 | 19.76/16.84 | 25.00/22.39 | 41.67/37.83 | 26.81/22.78 | - |
| MedGemma-4B | 11.56/11.58 | 8.24/5.88 | 39.06/27.99 | 1.83/3.38 | 21.06/16.73 | 40.44/36.59 | 20.36/17.02 | 12.48 / 6.97 |
| Lingshu-7B | 26.78/19.60 | 16.48/7.03 | 55.03/27.96 | 32.85/16.08 | 35.98/18.74 | 61.92/32.28 | 38.17/20.28 | 8.83 / 9.68 |
| Hulu-Med-7B | 19.06/16.62 | 5.71/4.69 | 54.83/28.07 | 31.07/15.89 | 38.27/22.01 | 52.23/41.12 | 33.53/21.40 | 5.86 / 6.33 |
| BreastGPT-8B | 36.66/18.00 | 42.01/11.48 | 58.54/28.81 | 20.12/11.37 | 30.70/18.49 | 35.55/21.97 | 37.26/18.35 | 17.97 / 22.61 |
ordering relative to Overall Acc. Thus, rankings vary substantially across evaluation forms. These results support Desideratum D3: preserving annotation-supported tasks across capability dimensions and assigning task-appropriate metrics materially changes the evidence provided by the benchmark, motivating decomposition of aggregate results by prediction target to reveal capability differences obscured by Overall summaries. Additional results are provided in Appendix D.
Annotation grounding provides a model-independent reference layer. MedBenchAgent treats the annotations associated with each source image as the reference standard. This design places trust in clinician annotations rather than external model judgments, avoiding an additional source of uncertainty. To test this strategy, we replace every evaluation image with a Gaussian-blurred image while keeping all non-image benchmark components unchanged. Across four medical VLMs, Acc. decreases by 5.86–17.97 percentage points (pp) and F1 by 6.33–22.61 pp (Table 5). The consistent degradation indicates that benchmark performance remains sensitive to visual evidence from the corresponding image, despite references being derived directly from source annotations rather than model-based visual judgments.
5.4 CROSS-DOMAIN CASE STUDY
To assess the cross-domain portability of MedBenchAgent, we apply the complete construction workflow under a specialized medical setting using ISIC 2018 (Codella et al., 2019; Tschandl et al., 2018), with a distinct dataset and annotation schema.
The resulting task space and representative VLM results are summarized in Figure 3. Representative VLMs show different relative strengths across prediction targets rather than a uniform performance pattern. This indicates that the same workflow can instantiate a domain-appropriate task structure under a distinct annotation schema

Figure 3: Cross-domain instantiation on dermoscopy.
These results provide cross-domain evidence for the portability of MedBenchAgent across annotation semantics and task definitions. Additional details are provided in Appendix C.
6 CONCLUSION
We introduced MedBenchAgent, a multi-agent framework that treats medical VLM benchmark construction as constrained compilation and makes benchmark specification an explicit, auditable object of construction. Through the Benchmark Intermediate Representation (BIR), MedBenchAgent separates specification planning from downstream item instantiation, allowing construction decisions to be evaluated stage by stage rather than only through the final benchmark. Our analyses identify open-ended task-space specification as the primary source of construction uncertainty, while annotation-evidence mapping and item instantiation become substantially more reliable once benchmark semantics are fixed. Evaluation of the resulting benchmark further reveals task-, metric-, and imaging-dependent variation across VLMs that aggregate scores can obscure. Together with the cross-domain instantiation under a specialized medical setting, these results show that con-strained, multi-agent benchmark construction can support both scalable medical VLM evaluation and systematic study of the benchmark-construction process itself.
Limitations and Future Directions. While MedBenchAgent moves medical benchmark construction towards greater automation, limited human involvement remains at planning checkpoints; we will further reduce this reliance by introducing supervisory agents to verify intermediate specifications. More broadly, MedBenchAgent provides a basis for comparing controlled benchmark compositions and for constructing larger collections of disease-, anatomy-, and modality-specific benchmarks.
REFERENCES
Seongsu Bae, Daeun Kyung, Jaehee Ryu, Eunbyeol Cho, Gyubok Lee, Sunjun Kweon, Jungwoo Oh, Lei Ji, Eric Chang, Tackeun Kim, and Edward Choi. Ehrxqa: A multi-modal question answering dataset for electronic health records with chest x-ray images. In A. Oh, T. Naumann, A. Globerson, K. Saenko, M. Hardt, and S. Levine (eds.), Advances in Neural Information Processing Systems, volume 36, pp. 3867–3880. Curran Associates, Inc., 2023. doi: 10.52202/075280-0170.
Shuai Bai, Keqin Chen, Xuejing Liu, Jialin Wang, Wenbin Ge, Sibo Song, Kai Dang, Peng Wang, Shijie Wang, Jun Tang, Humen Zhong, Yuanzhi Zhu, Ming-Hsuan Yang, Zhaohai Li, Jianqiang Wan, Pengfei Wang, Wei Ding, Zheren Fu, Yiheng Xu, Jiabo Ye, Xi Zhang, Tianbao Xie, Zesen Cheng, Hang Zhang, Zhibo Yang, Haiyang Xu, and Junyang Lin. Qwen2.5-vl technical report. CoRR, abs/2502.13923, 2025. doi: 10.48550/ARXIV.2502.13923.
Natasha Butt, Varun Chandrasekaran, Neel Joshi, Besmira Nushi, and Vidhisha Balachandran. Benchagents: Automated benchmark creation with agent interaction. In ICLR 2025 Workshop on Navigating and Addressing Data Problems for Foundation Models, 2025.
Pengcheng Chen, Jin Ye, Guoan Wang, Yanjun Li, Zhongying Deng, Wei Li, Tianbin Li, Haodong Duan, Ziyan Huang, Yanzhou Su, et al. Gmai-mmbench: A comprehensive multimodal evaluation benchmark towards general medical ai. Advances in Neural Information Processing Systems, 37: 94327–94427, 2024.
Noel C. F. Codella, Veronica Rotemberg, Philipp Tschandl, M. Emre Celebi, Stephen W. Dusza, David A. Gutman, Brian Helba, Aadi Kalloo, Konstantinos Liopyris, Michael A. Marchetti, Harald Kittler, and Allan Halpern. Skin lesion analysis toward melanoma detection 2018: A challenge hosted by the international skin imaging collaboration (ISIC). CoRR, abs/1902.03368, 2019. URL http://arxiv.org/abs/1902.03368.
David Dai, Peilin Chen, Chanakya Ekbote, and Paul Liang. Qoq-med: Building multimodal clinical foundation models with domain-aware grpo training. In D. Belgrave, C. Zhang, H. Lin, R. Pascanu, P. Koniusz, M. Ghassemi, and N. Chen (eds.), Advances in Neural Information Processing Systems, volume 38, Main Conference, pp. 37406–37453. Curran Associates, Inc., 2025. doi: 10.52202/085713-1256.
Tri Dao. Flashattention-2: Faster attention with better parallelism and work partitioning. In B. Kim, Y. Yue, S. Chaudhuri, K. Fragkiadaki, M. Khan, and Y. Sun (eds.), International Conference on Learning Representations, volume 2024, pp. 35549–35562, 2024.
Ryan D'Cunha, Alejandro Lozano, Xiaoxiao Sun, Daniel Vela Jarquin, Min Woo Sun, Josiah Aklilu, James Burgess, Yuhui Zhang, Ryan Nayebi, Paola Avila, Robayo, Jin Ye, Ming Hu, Zhongying Deng, Junjun He, Xin Chen, Yue Yao, Robert Tibshirani, Jeffrey J. Nirschl, and Serena Yeung-Levy. MMBU: A massive multi-modal biomedical understanding benchmark to probe the perception capabilities of vision-language models. CoRR, abs/2606.06696, 2026. doi:10.48550/ARXIV.2606.06696.
DeepSeek-AI. Deepseek-v4: Towards highly efficient million-token context intelligence. CoRR, abs/2606.19348, 2026. doi: 10.48550/ARXIV.2606.19348.
S. V. Destounis, S. M. Friedewald, L. J. Grimm, S. P. Poplack, and J. S. Sung. Mammography. In ACR BI-RADS v2025 Manual. American College of Radiology, Reston, VA, 2025.
Wilfrido Gómez-Flores, Maria Julia Gregorio-Calas, and Wagner Coelho de Albuquerque Pereira. Bus-bra: a breast ultrasound dataset for assessing computer-aided diagnosis systems. Medical physics, 51(4):3110–3123, 2024.
Google Research and Google DeepMind. Medgemma technical report. CoRR, abs/2507.05201, 2025. doi: 10.48550/ARXIV.2507.05201.
Yutao Hu, Tianbin Li, Quanfeng Lu, Wenqi Shao, Junjun He, Yu Qiao, and Ping Luo. Omnimedvqa: A new large-scale comprehensive evaluation benchmark for medical lvlm. In Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, pp. 22170–22183, 2024.
Songtao Jiang, Yuan Wang, Sibo Song, Tianxiang Hu, Chenyi Zhou, Bin Pu, Yan Zhang, Zhibo Yang, Yang Feng, Joey Tianyi Zhou, Jin Hao, Zijian Chen, Ruijia Wu, Tao Tang, Junhui Lv, Hongxia Xu, Hongwei Wang, Jun Xiao, Bin Feng, Fudong Zhu, Kenli Li, Weidi Xie, Jimeng Sun, Jian Wu, and Zuozhu Liu. Hulu-med: A transparent generalist model towards holistic medical vision-language understanding. CoRR, abs/2510.08668, 2025. doi: 10.48550/ARXIV.2510.08668.
Alexandros Karargyris, Renato Umeton, Micah J Sheller, Alejandro Aristizabal, Johnu George, Anna Wuest, Sarthak Pati, Hasan Kassem, Maximilian Zenk, Ujjwal Baid, et al. Federated benchmarking of medical artificial intelligence with medperf. Nature machine intelligence, 5(7):799–810, 2023.
Woosuk Kwon, Zhuohan Li, Siyuan Zhuang, Ying Sheng, Lianmin Zheng, Cody Hao Yu, Joseph Gonzalez, Hao Zhang, and Ion Stoica. Efficient memory management for large language model serving with pagedattention. In Proceedings of the 29th symposium on operating systems principles, pp. 611–626, 2023.
LASA Team, Weiwen Xu, Hou Pong Chan, Long Li, Mahani Aljunied, Ruifeng Yuan, Jianyu Wang, Chenghao Xiao, Guizhen Chen, Chaoqun Liu, Zhaodonghui Li, Yu Sun, Junao Shen, Chaojun Wang, Jie Tan, Deli Zhao, Tingyang Xu, Hao Zhang, and Yu Rong. Lingshu: A generalist foundation model for unified multimodal medical understanding and reasoning. CoRR, abs/2506.07044, 2025. doi: 10.48550/ARXIV.2506.07044.
Jason J Lau, Soumya Gayen, Asma Ben Abacha, and Dina Demner-Fushman. A dataset of clinically generated visual questions and answers about radiology images. Scientific data, 5(1):180251, 2018.
J. W. T. Leung, J. A. Baker, R. Hooley, V. A. Loving, and J. A. Rapelyea. Ultrasound. In ACR BI-RADS v2025 Manual. American College of Radiology, Reston, VA, 2025.
Patrick Lewis, Ethan Perez, Aleksandra Piktus, Fabio Petroni, Vladimir Karpukhin, Naman Goyal, Heinrich Küttler, Mike Lewis, Wen-tau Yih, Tim Rocktäschel, Sebastian Riedel, and Douwe Kiela. Retrieval-augmented generation for knowledge-intensive nlp tasks. In H. Larochelle, M. Ranzato, R. Hadsell, M.F. Balcan, and H. Lin (eds.), Advances in Neural Information Processing Systems, volume 33, pp. 9459–9474. Curran Associates, Inc., 2020.
Xiang Li, Farzaan Kaiyom, Evan Liu, Yifan Mai, Percy Liang, and Tatsunori Hashimoto. Autobencher: Towards declarative benchmark construction. In Y. Yue, A. Garg, N. Peng, F. Sha, and R. Yu (eds.), International Conference on Learning Representations, volume 2025, pp. 94357–94386, 2025.
Bo Liu, Li-Ming Zhan, Li Xu, Lin Ma, Yan Yang, and Xiao-Ming Wu. Slake: A semantically-labeled knowledge-enhanced dataset for medical visual question answering. In 2021 IEEE 18th international symposium on biomedical imaging (ISBI), pp. 1650–1654. IEEE, 2021.
Bo Liu, Hanxue Gu, Xiangru Li, Zheren Zhu, Jacob Ellison, Kang Wang, Janine M Lupo, Yang Yang, and Hui Lin. Automated report-derived oncology vqa benchmark for evaluating vision-language models on 3d medical imaging. arXiv preprint arXiv:2606.02809, 2026a.
Yang Liu, Jiajin Zhang, Danyang Tu, Yaojun Hu, Jiao Qu, Jiuyu Zhang, Yu Shi, Wei Fang, Shi Gu, Ling Zhang, and Yingda Xia. Breastgpt: A multimodal large language model for the full spectrum of breast cancer clinical routine. CoRR, abs/2606.04911, 2026b. doi: 10.48550/ARXIV.2606.04911.
Lena Maier-Hein, Annika Reinke, Michal Kozubek, Anne L Martel, Tal Arbel, Matthias Eisenmann, Allan Hanbury, Pierre Jannin, Henning Müller, Sinan Onogur, et al. Bias: Transparent reporting of biomedical image analysis challenges. Medical image analysis, 66:101796, 2020.
Hieu T Nguyen, Ha Q Nguyen, Hieu H Pham, Khanh Lam, Linh T Le, Minh Dao, and Van Vu. Vindr-mammo: A large-scale benchmark dataset for computer-aided diagnosis in full-field digital mammography. Scientific Data, 10(1):277, 2023.
Anna Pawłowska, Anna Čwierz-Pieńkowska, Agnieszka Domalik, Dominika Jaguś, Piotr Kasprzak, Rafał Matkowski, Łukasz Fura, Andrzej Nowicki, and Norbert Żołek. Curated benchmark dataset for ultrasound based breast lesion analysis. Scientific Data, 11(1):148, 2024.
Qwen Team. Qwen3-vl technical report. CoRR, abs/2511.21631, 2025. doi: 10.48550/ARXIV.2511.21631.
Qwen Team. Qwen3.5: Towards native multimodal agents, February 2026. URL https://qwen.ai/blog?id=qwen3.5.
Corentin Royer, Bjoern Menze, and Anjany Sekuboyina. Multimedeval: A benchmark and a toolkit for evaluating medical vision-language models. In Ninon Burgos, Caroline Petitjean, Maria Vakalopoulou, Stergios Christodoulidis, Pierrick Coupe, Hervé Delingette, Carole Lartizien, and Diana Mateus (eds.), Proceedings of The 7nd International Conference on Medical Imaging with Deep Learning, volume 250 of Proceedings of Machine Learning Research, pp. 1310–1327. PMLR, 03–05 Jul 2024. URL https://proceedings.mlr.press/v250/royer24a.html.
Ali S Tejani, Michail E Klontzas, Anthony A Gatti, John T Mongan, Linda Moy, Seong Ho Park, Charles E Kahn Jr, and CLAIM 2024 Update Panel. Checklist for artificial intelligence in medical imaging (claim): 2024 update. Radiology: Artificial Intelligence, 6(4):e240300, 2024.
Philipp Tschandl, Cliff Rosendahl, and Harald Kittler. The HAM10000 dataset, a large collection of multi-source dermatoscopic images of common pigmented skin lesions. Sci. Data, 5:180161, 2018. doi: 10.1038/sdata.2018.161.
Yuzhang Xie, Keqi Han, Yunpeng Xiao, Hejie Cui, Guanchen Wu, Ziyang Zhang, Kai Shu, Jiaying Lu, Xiao Hu, and Carl Yang. Ehrbench: An automated and reliable ehr-based benchmark for clinical decision making with llms. In Proceedings of the 32nd ACM SIGKDD Conference on Knowledge Discovery and Data Mining V.2, KDD '26, pp. 10068–10079, New York, NY, USA, 2026. Association for Computing Machinery. ISBN 9798400722592. doi: 10.1145/3770855.3817571.
Shiyun Xiong, Dongming Wu, Peiwen Sun, Yuang Ai, Bokang Yang, Wencheng Han, Xiao-Hui Li, and Xiangyu Yue. Benchmark everything everywhere all at once, 2026. URL https://arxiv.org/abs/2606.06462.
Xiaoman Zhang, Chaoyi Wu, Ziheng Zhao, Weixiong Lin, Ya Zhang, Yanfeng Wang, and Weidi Xie. Pmc-vqa: Visual instruction tuning for medical visual question answering. arXiv preprint arXiv:2305.10415, 2023.
Yanzhao Zhang, Mingxin Li, Dingkun Long, Xin Zhang, Huan Lin, Baosong Yang, Pengjun Xie, An Yang, Dayiheng Liu, Junyang Lin, Fei Huang, and Jingren Zhou. Qwen3 embedding: Advancing text embedding and reranking through foundation models, 2025. URL https://arxiv.org/abs/2506.05176.
Jinguo Zhu, Weiyun Wang, Zhe Chen, Zhaoyang Liu, Shenglong Ye, Lixin Gu, Hao Tian, Yuchen Duan, Weijie Su, Jie Shao, Zhangwei Gao, Erfei Cui, Xuehui Wang, Yue Cao, Yangzhou Liu, Xingguang Wei, Hongjie Zhang, Haomin Wang, Weiye Xu, Hao Li, Jiahao Wang, Nianchen Deng, Songze Li, Yinan He, Tan Jiang, Jiapeng Luo, Yi Wang, Conghui He, Botian Shi, Xingcheng Zhang, Wenqi Shao, Junjun He, Yingtong Xiong, Wenwen Qu, Peng Sun, Penglong Jiao, Han Lv, Lijun Wu, Kaipeng Zhang, Huipeng Deng, Jiaye Ge, Kai Chen, Limin Wang, Min Dou, Lewei Lu, Xizhou Zhu, Tong Lu, Dahua Lin, Yu Qiao, Jifeng Dai, and Wenhai Wang. Internvl3: Exploring advanced training and test-time recipes for open-source multimodal models. CoRR, abs/2504.10479, 2025. doi: 10.48550/ARXIV.2504.10479.
Table 6: TaskPlanningAgent's initial retained task proposals and supporting fields before task-space review.
| Dataset | Raw proposed task | Raw supporting field(s) |
|---|---|---|
| BrEaST: 11 retained proposals | ||
| BrEaST | anatomy_attribute.tissue_com position | study.annotation.tissue_composition |
| BrEaST | finding_attribute.shape | image.annotation.shape |
| BrEaST | finding_attribute.margin | image.annotation.margin |
| BrEaST | finding_attribute.echogenicity | image.annotation.echogenicity |
| BrEaST | finding_attribute.posterior_features | image.annotation.posterior_features |
| BrEaST | finding_attribute.calcifications | image.annotation.calcifications |
| BrEaST | finding_attribute.halo | image.annotation.halo |
| BrEaST | finding_attribute.skin_thickening | image.annotation.skin_thickening |
| BrEaST | assessment_category | image.annotation.birads |
| BrEaST | diagnosis | image.annotation.diagnosis |
| BrEaST | pathology_status | image.annotation.classification |
| BUS-BRA: 6 retained proposals | ||
| BUS-BRA | finding_type | image.annotation.histology |
| BUS-BRA | assessment_category | image.annotation.birads |
| BUS-BRA | diagnosis | image.annotation.histology |
| BUS-BRA | pathology_status | image.annotation.pathology |
| BUS-BRA | detection | image.annotation.bbox[*] |
| BUS-BRA | visual_grounding | image.annotation.bbox[*];image.annotation.histology |
| VinDr-Mammo: 6 retained proposals | ||
| VinDr | view_identification | image.annotation.view_position |
| VinDr | anatomy_attribute.breast_density | image.annotation.breast_density |
| VinDr | finding_type | image.annotation.findings[*].finding_categories[*] |
| VinDr | assessment_category | image.annotation.breast_birads |
| VinDr | detection | image.annotation.findings[*].bbox[*] |
| VinDr | visual_grounding | image.annotation.findings[*].bbox[*];image.annotation.findings[*].finding_categories[*] |
A CONSTRUCTED BREAST-IMAGING BENCHMARK
A.1 RAW TASK PROPOSALS AND EVIDENCE MAPPINGS
Table 6 transcribes every task that TaskPlanningAgent marked retain in the initial task_plans/v1.json output, before researcher confirmation. It shows the model's original task decomposition and its exact mapping from each proposed task to authorized annotation evidence. The count-affecting review decisions are reported separately in Appendix B.2.
A.2 AUDITED REPRESENTATIVE ITEMS
The 20 entries in Figures 4 and 5 give one audited item for every atomic dataset–task pair instantiated in the realized breast-imaging benchmark, spanning BrEaST, BUS-BRA, and VinDr-Mammo. For each entry, we show the source dataset, task definition, representative image, generated query, and corresponding benchmark reference answer.
B CONSTRUCTION ANALYSIS AND BENCHMARK VALIDATION
B.1 REFERENCE TASK SPACE AND TASK-SPACE EVALUATION PROTOCOL
Baselines. We compare MedBenchAgent with three direct task-planning baselines to evaluate BIR-mediated task-space compilation against direct task induction. All methods receive the same confirmed evaluation scope and the same dataset-specific profile derived from the normalized annotation schema . MedBenchAgent compiles the initial task tree within the BIR against the available annotation evidence through task retention and expansion. The direct baselines instead construct a complete set of prediction targets directly from and in a single model call per dataset. This comparison therefore evaluates catalog-initialized BIR compilation against direct task induction
BrEaST
finding_attribute.shape

Task description
Shape of the target finding
or abnormal region
Annotation
shape: oval
Question
How would you
describe the shape
of the lesion in this
ultrasound image?
Reference option: C
Options
A. round
B. irregular
C. oval
BrEaST
finding_attribute.margin

Task description
Margin characteristic of the
target finding or abnormal
region
Annotation
margin: not circumscribed -
indistinct
Question
Examine the
ultrasound image and
determine whether the
lesion margin is
circumscribed or not
circumscribed.
Reference option: B
Options
A. Circumscribed
B. Not circumscribed
BrEaST
finding_attribute.echogenicity

Task description
Echogenicity of the target
finding or abnormal region
Annotation
echogenicity: anechoic
Question
What is the
echogenicity pattern
of the lesion
observed on this
ultrasound image?
Reference option: B
Options
A. hypoechoic
B. anechoic
C. heterogeneous
D. isoechoic
BrEaST
finding_attribute.
posterior_features

Task description
Posterior acoustic features
of the target finding or
abnormal region
Annotation
posterior_features: shadowing
Question
Given the ultrasound
image, what is the
correct description
of the posterior
acoustic features
observed?
Options
A. Combined
B. Shadowing
pattern
C. Enhancement
D. No
posterior
features
Reference option: B
BrEaST
finding_attribute.halo

Task description
Presence of a halo sign
around the target finding or
abnormal region
Annotation
halo: no
Question
In this breast
ultrasound, does the
abnormal region
demonstrate a halo
sign?
Reference option: A
Options
A. No
B. Yes
BrEaST
finding_attribute.
skin_thickening

Task description
Presence of skin thickening
associated with the target
finding or abnormal region
Annotation
skin_thickening: no
Question
Does the imaged
breast lesion
demonstrate skin
thickening?
Reference option: A
Options
A. Absent
B. Present
BrEaST
pathology_status

Task description
Determine the benign,
malignant, or other
pathological status
associated with the imaging
finding or case.
Annotation
classification: benign
Question
What is the
pathological
classification of the
lesion seen in this
breast ultrasound?
Reference option: B
Options
A. Malignant B. Benign
C. Normal
BUS-BRA
pathology_status

Task description
Determine the benign,
malignant, or other
pathological status
associated with the imaging
finding or case.
Annotation
pathology: benign
Question
Which of the
following best
describes the
pathology of the
finding seen in this
ultrasound image:
benign or malignant?
Reference option: B
Options
A. Malignant B. Benign
VinDr-Mammo
anatomy_attribute.breast_density

Task description
Breast density category (A, B, C, D) indicating tissue composition
Annotation
breast_density: DENSITY C
Question
According to the
ACR BI-RADS
classification, which
breast density
category is depicted
in this mammogram?
Reference option: A
Options
A. DENSITY C
B. DENSITY B
C. DENSITY D
D. DENSITY A
BUS-BRA
detection

Task description
Locate a lesion or abnormal
region in the image without
identifying the target by a
specific finding name or
description.
Annotation
bbox: [47, 92, 161, 158]
Question
Can you provide the
bounding box that
localizes the area of
concern in this
ultrasound image?
Response
bbox
pixels: [47, 92, 161,
158]
Response: bounding box
VinDr-Mammo
detection

Task description
Locate a lesion or abnormal
region in the image without
identifying the target by a
specific finding name or
description.
Annotation
bbox: [779.625, 612.034,
1894.66, 2014.29]
Question
Please draw a
bounding box around
the area of concern
that should be
examined further.
Response
Response: bounding box
VinDr-Mammo
visual_grounding

Task description
Locate the single image
region corresponding to one
clearly specified,
localized, image-observable
finding or imaging sign.
Annotation
bbox: [9.002, 1212.4, 713.925,
2705.1799]
Question
Where is the Global
Asymmetry located in pixels: [9.002, 1212.4,
this mammogram?
Response: bounding box
Response
bbox
713.925, 2705.1799]
Figure 4: Representative audited items for 12 dataset–task mappings in the breast-imaging benchmark. Each card shows the source dataset and task, source annotation, representative image, generated query, and benchmark reference or spatial response.
under the same evaluation scope and dataset profile. Direct augments the DeepSeek-V4-Flash direct baseline with the initial BIR task definitions as prompt reference.
BrEaST
anatomy_attribute.
tissue_composition
Task description
Determine the global tissue
composition of the breast
anatomy
Annotation
tissue composition:
heterogeneous: predominantly fat

Question
What is the
appropriate
classification for
the breast tissue
composition observed
in this ultrasound
image?
Reference option: C
Options
A. Heterogeneous:
predominantly
fibroglandular
B. Homogeneous:
fibroglandular
C. Heterogeneous:
predominantly fat
D. Homogeneous: fat
BrEaST
finding_attribute.
calcifications

Task description
Presence and type of
calcifications in the target
finding or abnormal region
Annotation
calcifications: no
Question
What type of
calcifications is
present in the
abnormal area seen on
this breast
ultrasound?
Reference option: A
Options
A. No calcifications
B. Intraductal
calcifications
C. Indefinable
calcifications
D. Calcifications in a
mass
BrEaST
assessment_category

Task description
Determine the standardized
reporting category, assigned
to an imaging finding or
case.
Annotation
birads: 5
Question
Using the BI-RADS
lexicon, how should
this breast
ultrasound finding be
categorized?
Reference option: A
Options
A. BI-RADS 5: Highly
Suggestive of
Malignancy
B. BI-RADS 2: Benign
C. BI-RADS 4c: High
Suspicion
D. BI-RADS 1: Negative
E. BI-RADS 4a: Low
Suspicion
F. BI-RADS 4b: Moderate
Suspicion
G. BI-RADS 3: Probably
Benign
BrEaST
diagnosis

Task description
Determine the most likely
diagnosis for the imaged
finding or case.
Annotation
diagnosis: Invasive carcinoma
of no special type (NST)
Question
What diagnosis is
most consistent with
the breast lesion
seen on this
ultrasound?
Reference option: A
Options
A. Invasive carcinoma of
no special type (NST)
B. Fibroadenoma
C. Benign mammary
dysplasia
D. Invasive lobular
carcinoma
BUS-BRA
assessment_category

Task description
Determine the standardized
reporting category assigned
to an imaging finding or
case.
Annotation
birads: 3
Question
According to the
standardized breast
imaging reporting
system, which
category best
describes this
ultrasound finding?
Reference option: B
Options
A. BI-RADS 5: Highly
Suggestive of
Malignancy
B. BI-RADS 3: Probably
Benign
C. BI-RADS 4: Suspicious
D. BI-RADS 2: Benign
BUS-BRA
diagnosis

Task description
Determine the most likely
diagnosis for the imaged
finding or case.
Annotation
histology: invasive ductal
carcinoma
Question
What histologic
diagnosis is most
consistent with the
breast lesion seen on
ultrasound?
Reference option: B
Options
A. Fibrocystic changes
B. Invasive ductal
carcinoma
C. Cyst
D. Fibroadenoma
VinDr-Mammo
finding_type

Task description
Identify the explicitly
annotated visual category of
the primary imaging finding.
Annotation
finding categories:
Suspicious Calcification
Question
What mammographic
finding is
demonstrated in this
image?
Reference option: G
Options
A. Focal Asymmetry
B. Nipple Retraction
C. Skin Thickening
D. Suspicious Lymph Node
E. Mass
F. Architectural
Distortion
G. Suspicious
Calcification
H. Asymmetry
VinDr-Mammo
assessment_category

Task description
Determine the standardized
reporting category assigned
to an imaging finding or
case.
Annotation
breast birads: BI-RADS 2
Question
For this
mammography
study, which BI-RADS
assessment category
is most appropriate?
Reference option: C
Options
A. BI-RADS 5: Highly
Suggestive of
Malignancy
B. BI-RADS 3: Probably
Benign
C. BI-RADS 2: Benign
D. BI-RADS 1: Negative
E. BI-RADS 4: Suspicious
Figure 5: Continued from Figure 4. Representative samples from different dataset–task mappings, completing all 20 pairs.
For this comparison, both MedBenchAgent and the direct baselines are evaluated before human task-space confirmation. The MedBenchAgent result is the initial task-space proposal produced by TaskPlanningAgent, while each direct baseline is evaluated from its raw model output. All LLM baselines return a single JSON object through an OpenAI-compatible endpoint and are hosted locally on 1–2 NVIDIA B200 GPUs.
Reference task-space design. We designed the breast-imaging reference task space from the perspective of medical VLM evaluation, with the goal of covering the major stages of imaging diagnosis across the breast cancer diagnostic workflow. Informed by discussions within the research team and with a clinical collaborator, we abstracted this workflow into eight evaluation phases: image recognition and validity, global tissue characterization, lesion detection and localization, finding characterization, diagnostic classification, standardized assessment, management and integrated reasoning, and report generation. These phases provide a clinically structured progression from basic image interpretation to increasingly integrated diagnostic decisions, while remaining expressed as model-evaluable visual prediction capabilities.
We then applied this staged framework using the task definitions and reference annotations available in the public breast-imaging datasets considered in this study. For each phase, we defined a prediction target only when the corresponding annotations provided a clear reference standard, and we represented distinct prediction targets as separate atomic tasks. The framework defines the intended clinical coverage, while each dataset determines which stages have annotation-supported targets. Stages without an eligible target remain in the framework, showing both the covered capabilities and the parts of the broader imaging workflow not supported by the available public annotations.
Figure 6 reports the resulting dataset-conditioned reference task space. Under the atomic matching protocol below, the table contains 21 reference prediction targets in total. A phase may contain multiple atomic targets when the available annotations support distinct prediction targets, whereas a categorical prediction target such as VinDr finding-type classification remains one task even when its answer space contains multiple finding categories.
Independence from automated task-space construction. The staged framework and the resulting were developed before the automated task-space experiments and were fixed prior to evaluating MedBenchAgent or any direct-construction baseline. was not provided to any evaluated construction method, and the reference task space was not added to, removed from, split, or merged in response to method outputs. It therefore serves only as the external reference for measuring agreement between automatically constructed task spaces and the independently designed breast-imaging evaluation space.
Human involvement in task-space evaluation. Development of the reference framework and adjudication of method outputs were separated from the automated construction procedures. The reference-space design involved benchmark-design discussions among dataset-familiar researchers with clinical input. For the Task-Space F1 analysis reported in this work, matching and adjudication between method proposals and the fixed reference task space were performed by a researcher using the predefined rules below.
Prediction-target matching. The unit of evaluation was a dataset-conditioned prediction target. An ordinary task counted once; a decomposable parent category did not count separately, whereas each distinct prediction target under that parent was evaluated as one task. Matching was based on whether the proposal and reference represented the same prediction target, regardless of task identifier, surface wording, evaluation metric, response format, or JSON nesting. A raw proposal was counted as a true positive (TP) when it matched one reference prediction target in . A proposal without a corresponding reference task was counted as a false positive (FP), including unsupported, out-of-scope, shortcut-prone, or semantically redundant proposals. A reference task in without a semantically equivalent proposal was counted as a false negative (FN).
Matching was one-to-one. If multiple proposals represented the same reference prediction target, at most one was matched as a TP and each additional duplicate was counted as an FP. If a single proposal conflated multiple distinct prediction targets, it could match at most one reference task, with each remaining unmatched target counted as an FN. Differences that did not change the prediction target—including the evaluation metric, response format, bounding-box coordinate convention, surface wording, or exact annotation-field spelling—did not affect task-level matching.
Evidence-Mapping Agreement. For task proposals matched to , we additionally evaluated whether the method identified the annotation fields required to support the corresponding reference construction. Evidence-Mapping Agreement (EMA) was computed only over matched TPs. For each matched task, agreement was assigned a value of one when the method-proposed supporting-field set was identical to the supporting-field set confirmed during review against the dataset annotation schema , and zero otherwise. FPs and FNs were excluded from the EMA denominator.
Metrics and aggregation. For each method–dataset pair, we computed
We additionally report the number of task-space discrepancies between a raw proposal and , defined as . Overall results micro-aggregate TP, FP, and FN across the three datasets

Figure 6: Clinical breast-imaging workflow and its annotation-supported reference task space. Tasks are attached to the corresponding stages of the imaging workflow.
before applying these equations. Thus, datasets contribute according to their numbers of reference and proposed prediction targets rather than receiving equal dataset weight.
Direct task-induction baseline. The direct baselines receive the same confirmed benchmark requirement and dataset profile as MedBenchAgent, but do not receive the predefined task catalogue . They induce the complete task space in a single model call under the same output schema and evidence-admissibility rules, including annotation-supported prediction targets, atomic answer axes, semantic-duplicate removal, and explicit spatial-evidence requirements. The complete baseline prompts and serialization instructions are provided with the released code.
B.2 TASK-SPACE RESULTS AND DISCREPANCY ANALYSIS
Tables 7 and 8 detail task-space discrepancies for MedBenchAgent and the three direct baselines. Their matched tasks have supporting-field mappings consistent with the reference, as reflected by the EMA results in Table 1.
The discrepancy patterns also differ qualitatively across construction strategies. MedBenchAgent's residual errors are concentrated in semantic boundary cases, including a redundant BUS-BRA finding-type proposal, a visual-grounding proposal that did not define a capability distinct from generic detection, a shortcut-prone VinDr view-identification task, and the omitted finding-level assessment target. In contrast, the direct baselines more frequently introduce nonvisual metadata, acquisition or marker shortcuts, invalid spatial evidence, or omit otherwise supported visual prediction targets. This distinction helps explain why Evidence-Mapping Agreement is perfect for matched tasks even when task-space precision differs: once the intended prediction target is identified, annotation-field selection is comparatively stable, whereas deciding which targets should constitute the benchmark remains more difficult.
B.3 HUMAN ITEM AUDIT AND RESIDUAL ERRORS
Sampling and review setting. The audit population comprised all 16,248 finalized items accepted by the automatic screening and audit procedures in the completed BrEaST, BUS-BRA, and VinDr-
Table 7: Task-space discrepancies affecting TP, FP, or FN counts for MedBenchAgent and Direct DeepSeek. Retained true positives are omitted.
| Method | Dataset | Proposal or confirmed task | Label | Review rationale |
|---|---|---|---|---|
| MedBenchAgent | BUS-BRA | finding type | FP | Duplicated diagnosis on the histology answer axis. |
| MedBenchAgent | BUS-BRA | visual grounding | FP | Did not define a capability distinct from generic lesion detection. |
| MedBenchAgent | VinDr | view identification | FP | Burned-in view markers exposed the target as a shortcut. |
| MedBenchAgent | VinDr | finding-level assessment | FN | Finding-level BI-RADS supported a distinct, initially omitted answer axis. |
| Direct DeepSeek | BrEaST | clinical signs | FP | Nonvisual clinical metadata. |
| Direct DeepSeek | BrEaST | patient symptoms | FP | Nonvisual patient information. |
| Direct DeepSeek | BrEaST | verification method | FP | Nonvisual examination/pathology metadata. |
| Direct DeepSeek | BrEaST | tumor localization | FP | Treated a mask as bounding-box evidence. |
| Direct DeepSeek | BrEaST | diagnosis | FN | The explicit diagnosis field was not proposed as an independent task. |
| Direct DeepSeek | BUS-BRA | side identification | FP | Laterality metadata was outside the intended visual scope. |
| Direct DeepSeek | BUS-BRA | device identification | FP | Acquisition-device metadata was outside the clinical visual scope. |
| Direct DeepSeek | VinDr | laterality classification | FP | Metadata/marker shortcut rather than the intended image semantics. |
| Direct DeepSeek | VinDr | view-position classification | FP | Burned-in view marker leaked the target. |
| Direct DeepSeek | VinDr | visual grounding | FN | Finding category was not paired with its box. |
Table 8: Task-space discrepancies affecting TP, FP, or FN counts for Direct Qwen and Direct MedGemma. Retained true positives are omitted.
| Method | Dataset | Proposal or confirmed task | Label | Review rationale |
|---|---|---|---|---|
| Direct Qwen | BrEaST | palpability assessment | FP | Clinical palpation is not image-answerable. |
| Direct Qwen | BrEaST | interpretation classification | FP | A source conclusion is not an independent visual capability. |
| Direct Qwen | BrEaST | verification method | FP | Nonvisual confirmation metadata. |
| Direct Qwen | BrEaST | patient symptom status | FP | Nonvisual patient information. |
| Direct Qwen | BUS-BRA | lateralization | FP | Laterality metadata was outside the intended scope. |
| Direct Qwen | BUS-BRA | device identification | FP | Acquisition-device metadata was outside the intended scope. |
| Direct Qwen | VinDr | laterality classification | FP | Metadata/marker shortcut. |
| Direct Qwen | VinDr | view-position classification | FP | Burned-in view marker leaked the target. |
| Direct Qwen | VinDr | breast density | FN | A varying breast-density field supported an omitted global answer axis. |
| Direct Qwen | VinDr | visual grounding | FN | Finding category was not paired with its box. |
| Direct MedGemma | BrEaST | anatomy classification | FP | Anatomy was constant and could not form a valid classification task. |
| Direct MedGemma | BrEaST | modality classification | FP | Modality was constant. |
| Direct MedGemma | BrEaST | interpretation classification | FP | Source interpretation was not an independent visual capability. |
| Direct MedGemma | BrEaST | age classification | FP | Patient age was nonvisual metadata. |
| Direct MedGemma | BrEaST | patient symptoms | FP | Patient symptoms were nonvisual. |
| Direct MedGemma | BrEaST | signs classification | FP | Clinical-sign metadata was outside the target visual scope. |
| Direct MedGemma | BrEaST | verification classification | FP | Nonvisual confirmation metadata. |
| Direct MedGemma | VinDr | laterality classification | FP | Metadata/marker shortcut. |
| Direct MedGemma | VinDr | view-position classification | FP | Burned-in view marker leaked the target. |
| Direct MedGemma | VinDr | visual grounding | FN | Finding category was not paired with its box. |
Mammo runs. We globally shuffled this combined population and sampled 1,000 items uniformly without replacement.
We reviewed each sampled item using the predefined criteria below. The review materials comprised the dataset and task identifiers, response format, question, options, benchmark reference, and complete normalized annotation. The audit evaluated construction consistency against the source annotations and locked task specification.
Audit criteria. Four binary criteria were applied. Reference groundedness required the benchmark reference to follow directly from the authorized annotation evidence. Task–query alignment required the question to express the locked prediction target. Unambiguity required the question to admit one intended answer under the supplied evidence. Evaluation integrity required the absence of answer leakage, overlapping response options, question–reference mismatch, response-format mismatch, and unsupported additions. An item was considered valid only when all four criteria passed:
Table 9: ISIC 2018 tasks, supporting annotation fields, and realized item counts.
| Task | Supporting field | Resp. | Metric | Planned | Realized |
|---|---|---|---|---|---|
| Diagnosis | image.annotation.diagnosis | letter | Macro-F1 | 1,667 | 1,512 |
| Detection | image.annotation.findings[*].bbox[*] | bbox | mIoU | 1,666 | 1,000 |
| Globules presence | image.annotation.attribute_presence.globules | letter | Accuracy | 334 | 334 |
| Milia-like cyst presence | image.annotation.attribute_presence.milia_like_cyst | letter | Macro-F1 | 334 | 334 |
| Negative network presence | image.annotation.attribute_presence.negative_network | letter | Macro-F1 | 333 | 333 |
| Pigment network presence | image.annotation.attribute_presence.pigment_network | letter | Accuracy | 333 | 333 |
| Streaks presence | image.annotation.attribute_presence.streaks | letter | Macro-F1 | 333 | 333 |
| Total | 5,000 | 4,179 |
where , , , and denote reference groundedness, task–query alignment, unambiguity, and evaluation integrity, respectively.
Residual errors. Six of the 1,000 sampled items failed at least one audit criterion. Four VinDr-Mammo finding-type items exhibited the same template-level task–query mismatch: the generated question asked for a BI-RADS assessment category while the locked answer space contained finding categories. Two BrEaST diagnosis items introduced unsupported contextual details and therefore failed evaluation integrity. Importantly, the fixed annotation-derived reference answers remained supported by the authorized evidence in all six cases. Across the complete audit, there were four task–query-alignment failures and six evaluation-integrity failures, with no reference-groundedness or unambiguity failures.
C CROSS-DOMAIN PORTABILITY STUDY: DERMOSCOPY
C.1 DATASET, TASK SPACE, AND REALIZED ALLOCATION
The cross-domain run used the ISIC 2018 challenge data from its three official task sources: lesion segmentation (Task 1), dermoscopic-attribute detection (Task 2), and disease classification (Task 3). Tasks 1 and 2 share 1,000 held-out dermoscopic images, while Task 3 contributes 1,512 held-out diagnosis images. After deduplicating the shared Task 1/2 identifiers, the normalized corpus contains 2,512 unique images. Diagnosis labels are available for the Task 3 subset, whereas lesion masks and five dermoscopic-attribute masks are available for the Task 1/2 subset. Because these annotations are defined on different image subsets, no single task is eligible for all 2,512 images. We apply the workflow to the ISIC annotation schema and evaluate the resulting task-to-evidence mappings, item consistency, and model performance.
Task space and realized allocation. The requested 5,000-item allocation yielded 4,179 realized items because of source-data eligibility limits. All eligible diagnosis (1,512) and lesion-localization (1,000) cases were retained, with the remaining 1,667 items allocated across the five dermoscopic-attribute tasks. We checked the initial task plan against the documented ISIC annotation schema and label semantics. All seven proposed tasks and their supporting-field mappings were retained without task-space revision.
C.2 ITEM CONSISTENCY AND REPRESENTATIVE EXAMPLES
Item consistency. We additionally performed a consistency check on 200 finalized ISIC items using the same annotation- and contract-based criteria as the breast-imaging audit. All sampled items passed checks of reference–evidence consistency, task–query consistency, and evaluation-format integrity against the normalized annotations and locked task contracts.
Figure 7 provides one audited representative item for each of the seven dermoscopy tasks using the same presentation format as the breast-imaging examples.
ISIC 2018
finding_attribute.globules_presence

Task description
Presence of globules in the lesion
Annotation
attribute_presence.globules: true
Question
Options
Does the dermoscopic
A. Absent
B. Present
image of the skin
lesion show globules?
Reference option: B
ISIC 2018
finding_attribute.milia_like_cyst_presence

Task description
Presence of milia-like cysts
in the lesion
Annotation
attribute_presence.milia_like_cyst: true
Question
Options
What is the status of
A. Present
B. Absent
milia-like cysts in
this dermoscopic
image?
Reference option: A
ISIC 2018
finding_attribute.negative_network_presence

Task description
Presence of negative network
in the lesion
Annotation
attribute_presence.negative_
network: true
Question
Options
Does this lesion
exhibit a negative
network?
Reference option: A
ISIC 2018
finding_attribute.pigment_network_presence

Task description
Presence of pigment network
in the lesion
Annotation
attribute_presence.pigment_
network: true
Question
Options
Does the dermoscopic
A. Absent
B. Present
image show a pigment
network?
Reference option: B
ISIC 2018
finding_attribute.streaks_presence

Task description
Presence of streaks in the
lesion
Annotation
attribute_presence.streaks: true
Question
Options
Regarding streaks in
A. Present
B. Absent
this dermoscopic
image, which finding
is observed?
Reference option: A
ISIC 2018
detection

Task description
Locate a lesion or abnormal
region in the image without
identifying the target by a
specific finding name or
description.
Annotation
bbox: [984, 684, 2184, 1584]
Question
Please outline the
skin lesion in the
image by providing
the bounding box
coordinates.
Response
bbox
pixels: [984, 684, 2184,
1584]
Response: bounding box
ISIC 2018
diagnosis

Task description
Determine the most likely
diagnosis for the imaged
finding or case.
Annotation
diagnosis: BCC
Question
Options
Given the dermoscopic
A. Melanoma
image, what is the
B. Melanocytic nevus
most likely
C. Dermatofibroma
diagnosis?
D. Basal cell carcinoma
Reference option: D
E. Vascular lesion
F. Actinic keratosis /
Bowen's disease
G. Benign keratosis
Figure 7: Representative audited ISIC 2018 items for all seven dermoscopy tasks.
C.3 MODEL EVALUATION
Table 10 reports performance across diagnosis, dermoscopic attributes, and localization. Different checkpoints lead on different task metrics, providing complementary evaluation profiles. Together with the task-space review and item audit, these results demonstrate application of MedBenchAgent to the ISIC annotation schema.
Table 10 shows that the cross-domain benchmark preserves substantial variation across task families and model checkpoints. No single checkpoint exhibits uniformly strong performance across diagnosis, dermoscopic attributes, and lesion localization, and the relative behavior of general-purpose and medical VLMs varies across these task types. In particular, categorical performance does not reliably predict spatial-localization performance. These results are consistent with the breast-imaging evaluation in showing that aggregate model quality cannot be inferred from one task family alone, while providing evidence that the same construction workflow can be instantiated under a different annotation schema and clinical vocabulary.
Table 10: Evaluation performance on ISIC 2018. Choice tasks report Accuracy / Macro-F1 (%), while detection reports mIoU / Acc@IoU0.5 (%). Best results for each metric are shown in bold.
| Model | Diagnosis | Finding Attribute | Detection | ||||
|---|---|---|---|---|---|---|---|
| Globules | Milia-like | Neg. net. | Pigment net. | Streaks | |||
| General-purpose VLMs | |||||||
| InternVL3-8B | 20.7/15.3 | 31.4/31.1 | 70.7/56.6 | 45.3/35.0 | 72.4/63.4 | 39.3/35.7 | 50.5/52.2 |
| Qwen2.5-VL-7B | 24.2/14.6 | 57.8/53.7 | 80.8/55.5 | 83.8/47.4 | 59.5/59.3 | 33.6/30.7 | 75.1/86.6 |
| Qwen3-VL-8B-I | 53.2/22.8 | 28.4/27.5 | 80.2/61.8 | 80.2/47.3 | 59.5/58.4 | 58.0/44.7 | 80.3/91.4 |
| Qwen3-VL-8B-T | 30.9/18.6 | 60.5/52.9 | 83.2/61.1 | 85.0/48.2 | 57.1/56.0 | 82.9/47.0 | 71.2/83.6 |
| Qwen2.5-VL-32B | 29.8/20.8 | 25.1/23.6 | 46.7/40.2 | 28.5/24.3 | 72.4/64.5 | 15.9/15.9 | 76.8/87.6 |
| Qwen3-VL-32B | 52.8/30.3 | 70.1/58.2 | 84.4/55.1 | 74.2/45.8 | 58.0/57.3 | 88.0/55.1 | 80.2/92.2 |
| Medical VLMs | |||||||
| MedGemma-4B | 47.8/31.5 | 25.7/24.0 | 66.8/52.5 | 45.3/33.5 | 79.0/71.7 | 59.5/47.7 | 31.8/29.1 |
| Lingshu-7B | 10.6/7.0 | 68.3/57.2 | 82.9/53.9 | 46.8/36.2 | 76.9/71.4 | 46.5/38.4 | 11.7/6.8 |
| Hulu-Med-7B | 56.3/34.4 | 75.4/47.4 | 83.8/59.0 | 95.2/48.8 | 40.8/38.6 | 76.6/48.9 | 0.7/0.2 |
| QoQ-Med-7B | 49.5/21.4 | 69.2/48.2 | 84.7/55.6 | 90.7/47.6 | 41.1/39.2 | 75.7/46.8 | 25.8/11.3 |
| Lingshu-32B | 24.6/16.8 | 71.9/60.3 | 75.7/53.5 | 44.1/33.9 | 72.4/69.2 | 57.4/44.8 | 44.5/53.3 |
D ADDITIONAL MODEL-EVALUATION RESULTS
D.1 EVALUATION PROTOCOL
For reporting, fine-grained question types in Table 3 are first scored separately and macro-averaged within their parent task where applicable, while dataset-specific results for the same task family are then macro-averaged with equal weight, and the reported Overall score macro-averages the resulting task-family scores.
In this section, we report the complete per-dataset model-evaluation results and detailed evaluation protocol. Tables 11, 13, and 14 use the same two-level template to report dataset-level task results for BrEaST, BUS-BRA, and VinDr-Mammo. The abbreviations are AA (anatomy attribute), FA (finding attribute), FT (finding type), AC (assessment category), DX (diagnosis), and PS (pathology status). Table 12 separately expands BrEaST FA into its seven question types. Table 15 reports mIoU and Acc@IoU for each dataset–task pair. Scores are computed over all evaluated items, assigning zero IoU when no valid bounding box is returned.
Inputs and response parsing. Each model received the image, question, and lettered options when applicable, without the reference answer. Model-specific chat templates were applied with deterministic decoding. Multiple-choice predictions were parsed as a single valid option letter and evaluated using Accuracy and Macro-F1 over semantic answer classes. Invalid responses remained incorrect. Spatial predictions were parsed as a single four-number bounding box, accepting the supported bbox or bbox_2d fields, bare lists or tuples, and JSON-fenced outputs. Missing, malformed, nonfinite, degenerate, out-of-range, or multiple distinct boxes were invalid and received zero IoU.
Coordinate conversion and scoring. We strictly follow the protocols of all models that claim to have spatial evaluation capabilities. Predictions were converted from the configured model-specific coordinate representation to absolute original-image coordinates before scoring. Qwen3-VL, InternVL3, and BreastGPT used a fixed [0, 1000] coordinate space; Qwen2.5-VL, Lingshu, and QoQ-Med used coordinates in the resized model input; and Hulu-Med used original-image coordinates. MedGemma used normalized [0, 1] coordinates in order, which were reordered and rescaled. The effective coordinate size was recorded with each prediction. Spatial metrics were computed over all evaluated items, including invalid outputs. Accordingly, mIoU and Acc@IoU measure end-to-end bounding-box prediction under the specified response protocol.
D.2 PAIRWISE MODEL-ORDERING ANALYSIS
The summary statistics of model-ordering reversals are reported in Section 5.3. Here, we provide the detailed pairwise model-ordering analysis and describe how these statistics are computed. For two
Table 11: Multiple-choice evaluation on BrEaST by task type. Results are reported as Accuracy / Macro-F1 (%). AA contains 200 tissue-composition items; FA equally averages its seven question types; AC and PS each contain 256 items; and DX contains 121 items. † denotes thinking variants.
| Model | Anatomy | Finding | Assessment & Diagnosis | ||
|---|---|---|---|---|---|
| AA | FA | AC | DX | PS | |
| General-purpose VLMs | |||||
| InternVL3-8B | 27.5/10.8 | 42.3/30.9 | 18.8/10.1 | 28.9/16.3 | 50.8/33.4 |
| Qwen2.5-VL-7B | 33.0/19.5 | 41.5/29.3 | 16.4/10.5 | 34.7/21.3 | 54.7/36.4 |
| Qwen3-VL-8B-I | 27.5/10.9 | 29.8/22.6 | 20.7/16.7 | 38.8/26.9 | 60.9/40.3 |
| Qwen3-VL-8B-T | 28.0/13.4 | 56.9/35.1 | 21.1/19.3 | 38.0/24.5 | 49.2/32.7 |
| Qwen2.5-VL-32B | 25.0/15.2 | 46.2/29.6 | 19.1/13.2 | 48.8/27.3 | 47.3/31.6 |
| Qwen3-VL-32B | 17.5/12.9 | 37.1/28.4 | 20.7/20.8 | 35.5/27.7 | 62.9/53.0 |
| Medical VLMs | |||||
| MedGemma-4B | 26.5/16.0 | 47.5/33.9 | 19.5/13.4 | 44.6/32.4 | 51.6/36.9 |
| Lingshu-7B | 33.5/24.0 | 56.8/38.7 | 24.6/25.0 | 46.3/18.8 | 69.1/40.4 |
| Hulu-Med-7B | 27.0/11.3 | 51.1/35.5 | 20.7/16.0 | 44.6/24.4 | 61.7/41.3 |
| QoQ-Med-7B | 30.0/20.7 | 66.1/37.8 | 20.7/13.7 | 43.0/23.5 | 48.8/31.5 |
| BreastGPT-8B | 21.5/19.9 | 75.2/52.5 | 36.3/36.1 | 60.3/39.7 | 68.4/55.5 |
| Lingshu-32B | 31.5/22.2 | 57.5/43.0 | 23.4/18.7 | 47.1/20.3 | 67.2/42.3 |
models and , an ordering reversal between scores and occurs when
With 12 evaluated VLMs, there are unordered model pairs. Ties are not counted as reversals.
Overall versus task-level evaluation. We compare the ordering induced by Overall Acc. in Table 3 with the Acc. ordering for each task category. The numbers of reversed pairs are 19 (AA), 22 (FT), 18 (FA), 24 (AC), 12 (DX), and 22 (PS), corresponding to 18.2–36.4% of all model pairs.
Acc. versus F1. Within each task category, we compare model ordering under Acc. and F1. The numbers of reversed pairs are 13 (AA), 11 (FT), 5 (FA), 15 (AC), 15 (DX), and 4 (PS), corresponding to 6.1–22.7%.
Choice-based versus spatial evaluation. We compare Overall Acc. with each of the six spatial measures in Table 4. The numbers of reversed model pairs are 33 and 32 for VinDr-Mammo detection, 34 and 32 for VinDr-Mammo visual grounding, and 29 and 28 for BUS-BRA detection, for mIoU and Acc@IoU , respectively. Thus, 28–34 of the 66 model pairs (42.4–51.5%) reverse their ordering across the spatial measures.
D.3 ADDITIONAL ANALYSIS OF MODEL BEHAVIOR
The results allow us to examine how aggregate model performance is composed and where model comparisons change with the evaluation target, metric, or imaging setting. We first analyze variation within task families, then examine changes across model scales and thinking variants, and finally compare categorical and spatial performance across imaging settings. Throughout, comparisons refer to the evaluated checkpoints under the reported protocols.
D.3.1 TASK GRANULARITY AND METRIC-DEPENDENT RANKINGS
Strong task-family performance can coexist with substantial variation among its constituent prediction targets. BreastGPT-8B achieves the highest aggregate finding-attribute scores, yet its BrEaST Macro-F1 ranges from 78.0 on margin and 63.7 on halo to 33.2 on posterior features and 35.0 on calcifications (Table 12). The aggregate FA score therefore combines markedly different attribute-level results. Retaining these prediction targets separately identifies which attributes contribute to a model's overall advantage and which remain comparatively weak under their respective evaluation settings.
Table 12: Multiple-choice evaluation on BrEaST: finding-attribute question types. Results are reported as Accuracy / Macro-F1 (%). Best results for each metric are shown in bold.
| Model | Finding Attribute | ||||||
|---|---|---|---|---|---|---|---|
| Shape | Margin | Echo. | Posterior | Calc. | Halo | Skin | |
| General-purpose VLMs | |||||||
| InternVL3-8B | 54.5/30.9 | 53.2/53.0 | 46.3/33.1 | 21.8/15.6 | 45.2/23.0 | 26.0/24.4 | 48.8/35.9 |
| Qwen2.5-VL-7B | 55.4/26.8 | 58.3/47.4 | 40.3/28.3 | 19.4/8.1 | 27.8/14.7 | 47.6/44.6 | 41.4/35.1 |
| Qwen3-VL-8B-I | 34.3/28.6 | 47.2/42.2 | 25.5/16.2 | 37.3/24.8 | 50.4/24.0 | 11.4/16.7 | 2.7/5.6 |
| Qwen3-VL-8B-T | 56.6/34.4 | 58.3/45.8 | 61.5/28.4 | 22.2/12.4 | 59.9/30.4 | 63.4/46.6 | 76.6/47.8 |
| Qwen2.5-VL-32B | 57.4/32.3 | 55.2/45.3 | 61.0/35.1 | 22.2/12.4 | 71.0/28.6 | 47.2/43.8 | 9.4/9.4 |
| Qwen3-VL-32B | 58.7/39.9 | 32.9/40.3 | 45.0/34.7 | 23.8/17.9 | 52.0/24.7 | 15.9/17.3 | 31.2/24.2 |
| Medical VLMs | |||||||
| MedGemma-4B | 52.9/40.8 | 54.8/52.8 | 39.8/23.3 | 52.8/24.6 | 29.0/14.2 | 42.3/39.6 | 61.3/42.3 |
| Lingshu-7B | 58.3/45.6 | 63.9/60.2 | 63.6/32.6 | 13.9/9.4 | 44.0/18.8 | 65.4/48.5 | 88.7/55.5 |
| Hulu-Med-7B | 58.3/34.1 | 59.5/50.0 | 58.9/38.6 | 25.8/19.1 | 17.9/13.3 | 64.6/45.0 | 73.0/48.4 |
| QoQ-Med-7B | 52.1/30.6 | 65.1/62.2 | 51.9/30.5 | 57.9/25.8 | 75.4/27.2 | 72.0/41.8 | 88.3/46.9 |
| BreastGPT-8B | 73.6/56.1 | 78.6/78.0 | 70.6/45.3 | 54.8/33.2 | 89.3/35.0 | 70.3/63.7 | 89.5/56.3 |
| Lingshu-32B | 59.9/47.5 | 67.9/64.4 | 62.8/44.7 | 23.0/21.0 | 45.2/22.9 | 65.4/44.6 | 78.5/56.1 |
Table 13: Multiple-choice evaluation on BUS-BRA by task type. Results are reported as Accuracy / Macro-F1 (%). † denotes thinking variants. Best results for each metric are shown in bold.
| Model | Assessment & Diagnosis | ||
|---|---|---|---|
| AC | DX | PS | |
| General-purpose VLMs | |||
| InternVL3-8B | 25.7/24.1 | 41.8/29.4 | 47.1/47.1 |
| Qwen2.5-VL-7B | 37.0/15.6 | 32.8/24.1 | 47.4/47.3 |
| Qwen3-VL-8B-I | 35.3/20.5 | 41.1/32.4 | 60.2/55.4 |
| Qwen3-VL-8B-T | 31.2/20.9 | 32.2/23.8 | 56.9/52.3 |
| Qwen2.5-VL-32B | 34.1/21.2 | 37.8/26.0 | 58.6/53.2 |
| Qwen3-VL-32B | 36.2/20.8 | 43.2/31.9 | 55.8/55.6 |
| Medical VLMs | |||
| MedGemma-4B | 22.6/22.4 | 15.8/15.1 | 60.0/51.8 |
| Lingshu-7B | 38.6/26.3 | 58.1/39.8 | 73.3/64.6 |
| Hulu-Med-7B | 26.3/25.4 | 54.6/45.0 | 66.6/61.8 |
| QoQ-Med-7B | 36.9/14.5 | 39.9/24.7 | 35.4/29.4 |
| BreastGPT-8B | 45.0/36.5 | 69.8/54.4 | 88.8/87.1 |
| Lingshu-32B | 33.3/28.0 | 51.0/28.7 | 73.0/68.1 |
Table 14: Multiple-choice evaluation on VinDr-Mammo by task type. Results are reported as Accuracy / Macro-F1 (%). Best results for each metric are shown in bold.
| Model | Anatomy | Finding | Assessment & Diagnosis |
|---|---|---|---|
| AA | FT | AC | |
| General-purpose VLMs | |||
| InternVL3-8B | 45.7/23.8 | 19.1/8.7 | 3.9/4.2 |
| Qwen2.5-VL-7B | 64.7/26.6 | 29.8/10.2 | 10.7/9.6 |
| Qwen3-VL-8B-I | 42.3/26.2 | 16.3/9.0 | 61.4/22.0 |
| Qwen3-VL-8B-T | 23.0/14.9 | 15.1/7.3 | 63.4/19.9 |
| Qwen2.5-VL-32B | 64.4/28.0 | 54.0/12.7 | 27.3/15.9 |
| Qwen3-VL-32B | 57.1/28.0 | 54.6/13.3 | 45.8/20.1 |
| Medical VLMs | |||
| MedGemma-4B | 18.3/15.4 | 23.2/10.8 | 11.8/10.3 |
| Lingshu-7B | 55.0/28.3 | 32.2/12.3 | 12.7/11.3 |
| Hulu-Med-7B | 36.2/22.0 | 17.0/9.2 | 21.2/15.1 |
| QoQ-Med-7B | 67.1/24.7 | 53.8/12.0 | 3.7/2.5 |
| BreastGPT-8B | 50.6/32.9 | 35.7/17.0 | 40.8/22.1 |
| Lingshu-32B | 70.3/27.2 | 42.7/14.2 | 45.8/18.3 |
Table 15: Spatial evaluation on BUS-BRA and VinDr-Mammo. Results report mIoU and Acc@IoU (%). Best results for each metric are shown in bold.
| Model | BUS-BRA Detection | VinDr Detection | VinDr Visual Grounding | |||
|---|---|---|---|---|---|---|
| mIoU | Acc@.5 | mIoU | Acc@.5 | mIoU | Acc@.5 | |
| General-purpose VLMs | ||||||
| InternVL3-8B | 26.0 | 11.2 | 3.3 | 0.2 | 3.2 | 0.3 |
| Qwen2.5-VL-7B | 28.9 | 22.2 | 7.6 | 3.9 | 8.8 | 6.5 |
| Qwen3-VL-8B-I | 51.1 | 56.4 | 10.7 | 7.0 | 13.7 | 11.0 |
| Qwen3-VL-8B-T | 37.5 | 32.9 | 10.9 | 7.3 | 10.4 | 7.0 |
| Qwen2.5-VL-32B | 40.6 | 37.5 | 9.7 | 6.1 | 10.8 | 7.3 |
| Qwen3-VL-32B | 55.4 | 62.1 | 15.4 | 12.9 | 18.0 | 16.8 |
| Medical VLMs | ||||||
| MedGemma-4B | 15.7 | 3.7 | 1.5 | 0.0 | 1.6 | 0.0 |
| Lingshu-7B | 4.7 | 0.9 | 4.4 | 0.8 | 3.6 | 0.7 |
| Hulu-Med-7B | 7.0 | 3.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| QoQ-Med-7B | 45.6 | 43.5 | 7.0 | 1.1 | 7.0 | 1.3 |
| BreastGPT-8B | 72.6 | 82.8 | 5.3 | 0.9 | 5.4 | 1.1 |
| Lingshu-32B | 12.5 | 4.4 | 4.7 | 1.5 | 5.6 | 2.0 |
The choice of metric also changes comparisons within an individual attribute. On posterior features, QoQ-Med-7B achieves higher Accuracy than BreastGPT-8B (57.9 versus 54.8), whereas BreastGPT-8B achieves higher Macro-F1 (33.2 versus 25.8). The same ordering reversal occurs on halo: QoQ-Med-7B leads in Accuracy (72.0 versus 70.3), but BreastGPT-8B leads in Macro-F1 (63.7 versus 41.8). These reversals extend the metric-dependent rankings observed in the main results to atomic prediction targets. Accuracy weights individual items equally, while Macro-F1 averages class-specific F1 scores; consequently, the two metrics capture different aspects of performance over the answer space. Reporting both preserves distinctions that either metric alone would omit.
D.3.2 CHANGES ACROSS MODEL SCALES AND THINKING VARIANTS
Similar aggregate scores can conceal large changes in the underlying task profile. Qwen3-VL-8B-T exceeds Qwen3-VL-8B-I by only 0.60 Accuracy points overall, but the task-level changes are much larger (Table 3). FA improves by 27.09 points, while AA, FT, AC, DX, and PS decrease by 9.37, 1.22, 0.53, 4.85, and 7.50 points, respectively. Under the reported equal weighting of task families, the FA improvement contributes approximately 4.52 points to Overall Accuracy, while the other five tasks jointly contribute approximately -3.91 points. The small net change thus results from opposing task-level changes rather than uniformly similar performance.
The FA improvement is itself concentrated in particular attributes. On BrEaST, halo Accuracy increases from 11.4 to 63.4 and skin-thickening Accuracy from 2.7 to 76.6, whereas posterior-feature Accuracy decreases from 37.3 to 22.2 (Table 12). With seven equally weighted attributes, the halo and skin-thickening increases together contribute approximately 18.0 points to the roughly 27.1-point FA improvement, based on the rounded attribute scores. Decomposing the comparison at both levels therefore reveals a pattern that the Overall score obscures: a substantial gain within one task family is driven largely by a subset of its prediction targets and offset by declines elsewhere.
Changes across model scales also vary by task. Within Lingshu, the 32B checkpoint improves Overall Accuracy from 47.00 to 50.73 and FA Macro-F1 from 38.66 to 43.01 relative to the 7B checkpoint, while DX Macro-F1 decreases from 29.29 to 24.54. In contrast, Qwen3-VL-32B improves over Qwen3-VL-8B-I on aggregate multiple-choice performance and all three reported breast-imaging spatial settings (Tables 3 and 4). These checkpoint comparisons show that aggregate improvements can have different task-level compositions. They support examining the resulting performance profile rather than using model scale or the thinking designation as a substitute for task-specific evaluation.
D.3.3 PERFORMANCE ACROSS IMAGING SETTINGS AND SPATIAL TASKS
Relative performance on categorical tasks does not consistently carry over to bounding-box prediction. On ISIC, Hulu-Med-7B achieves the highest diagnosis Accuracy and Macro-F1 among the evaluated checkpoints (56.3 and 34.4), but obtains 0.7 mIoU and 0.2 Acc@IoU on detection. Qwen3-VL-8B-
I achieves lower diagnosis scores (53.2 and 22.8), yet substantially higher detection scores (80.3 and 91.4; Table 10). These results describe complementary task profiles within the same dataset family. Because diagnosis and detection use different ISIC annotation subsets, the comparison concerns dataset-level performance rather than paired success and failure on individual images. The spatial scores measure end-to-end box prediction, including response validity under the evaluation protocol.
Spatial rankings also change across imaging settings. BreastGPT-8B leads Qwen3-VL-32B on BUS-BRA detection, with Acc@IoU of 82.80 versus 62.08, whereas Qwen3-VL-32B leads on VinDr-Mammo detection, with 12.86 versus 0.90 (Table 4). This ranking reversal shows that a model's advantage within one localization setting need not persist in another. Reporting each dataset–task pair separately preserves this distinction and prevents a pooled spatial score from obscuring where the observed advantage applies.