Manuscript Offprint

arXiv:2610.11610

Beyond Report Imitation: Clinically Aware Multi-Image Ultrasound Report Generation from Visible Evidence

Yuchen Yang, Xin Wang, Lufan Wang, Yinghong Pan, Yujuan Feng, Yuqing Yang

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Yuchen Yang 1^{1}

3319733548@bupt.edu.cn

Wang Xin 2^{2}

wangxin21@pumch.cn

Lufan Wang 1^{1}

wlf@bupt.edu.cn

Yinghong Pan 1^{1}

panyinghong@bupt.edu.cn

Yujuan Feng 3^{3}

yujuanf15@bjut.edu.cn

Yuqing Yang 1,∗^{1,*}

yangyuqing@bupt.edu.cn

1^{1} State Key Laboratory of Networking and Switching Technology, Beijing University of Posts and Telecommunications, Beijing, China

2^{2}Department of Ultrasound, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China

3^{3}College of Computer Science, Beijing University of Technology, Beijing, China

Abstract

Generating ultrasound reports from multiple images requires aggregating clinical evidence across views, yet archived key frames capture only part of the dynamic examination. Raw-report imitation is therefore misaligned with visual supervision: content that is clinically valid for the full examination may be unverifiable from the images available to a model. This gap creates a clinical behavior alignment problem. A model must preserve visible findings, avoid diagnostic reversals and unsupported completion, and not collapse into conservative templates. We propose CAMEO, a Clinically Aware Multi-image Evidence-grounded Orchestration framework for ultrasound report generation. Stage I learns ultrasound visual-language primitives; Stage II performs Cross-View Evidence Grounding by distilling trusted visible report points into multi-image QA and report-style supervision; and Stage III performs Clinically Aware Preference Alignment using clinical-error-oriented preference pairs. From USReport, we construct USREPORT-DISTILLED with 17,670 evidence-grounded paired-image training instances and USREPORT-PREF with 21,869 preference pairs; we additionally use 25,631 PUBMEDVISION-US ultrasound instruction samples for domain adaptation and multi-image instruction tuning. On the primary USREPORT-DISTILLED benchmark, CAMEO improves over EchoVLM from 0.25 to 0.40 BLEU-1, 0.28 to 0.45 ROUGE-1, and 0.27 to 0.43 METEOR, while raising ClinicalScore from 55.02 to 74.20. These results underscore the value of evidence-grounded supervision, clinically aware alignment, and clinically structured evaluation for reliable ultrasound report generation. Code and project resources: https://github.com/NiHaoWoJiaoYYC/CAMEO.

© 2026. The copyright of this document resides with its authors. It may be distributed unchanged freely in print or electronic forms.

∗^{*}Corresponding author.

Figure

Figure 1: Motivation. Archived ultrasound key frames only partially observe the dynamic examination. Raw report imitation can therefore introduce unsupported supervision, and reference-based metrics can reward non-grounded completion. CAMEO uses trusted visible evidence for cross-view training, preference alignment, and clinical error evaluation.

1 Introduction

Ultrasound is safe, relatively inexpensive, real-time, and widely used in routine care. Its interpretation is inherently multi-view: clinicians integrate scanning planes, probe-dependent appearances, and complementary key frames before writing a report. Multi-image ultrasound report generation is therefore not a collection of independent frame captions, but a problem of aggregating evidence across views and expressing it in clinically bounded language. A useful model must determine which observations are visible, how they relate across views, and how strongly they support report-level statements.

Recent MLLMs make this task increasingly feasible. Medical instruction tuning and large-scale biomedical image-text data improve domain coverage [6,8,10][6, 8, 10], while multi-image MLLMs support comparison, coreference, and cross-image aggregation [6,1,1][6, 1, 1]. However, input capacity and domain coverage alone do not guarantee reliable ultrasound reports. A model may produce fluent report text from modality priors or common templates while failing to preserve the specific evidence visible in the archived images.

A central source of this reliability problem is partial visual observability. A clinical ultrasound report may incorporate dynamic scanning, unarchived views, measurements, and contextual decisions, whereas a model usually receives only archived key frames. Some report statements are visible in these images; others may be clinically valid for the full examination but unverifiable from the available image set. Direct raw-report imitation therefore turns unobserved examination content into apparent image-grounded supervision.

This mismatch creates the twofold misalignment illustrated in Fig. 1. During training, unverifiable report points can become positive visual targets, encouraging completion from language priors. During evaluation, lexical metrics may reward plausible but unsupported completion while penalizing evidence-faithful outputs that omit unverifiable reference text. This is not ordinary label noise: a reference report may be clinically correct for the full examination yet still be an inappropriate image-grounded target for the archived image pair.

The central challenge is not merely to remove unverifiable report content, but to define the desired model behavior under incomplete visual evidence. A reliable model should report visible abnormalities, preserve view-specific attribution, avoid unsupported diagnostic escalation, qualify claims when evidence is insufficient, and avoid conservative templates that omit visible findings. These requirements make report generation a clinically aware alignment problem rather than a data-cleaning exercise: the model must be informative when evidence is present and restrained when it is absent.

We formulate the task as clinically aware evidence-grounded generation under partial visual observability. CAMEO distills trusted visible evidence from raw reports, converts it into cross-view SFT data and clinical-error-oriented preference pairs, and evaluates generations against the same evidence structure. Training proceeds through Stage I Ultrasound Domain Adaptation, Stage II Cross-View Evidence Grounding, and Stage III Clinically Aware Preference Alignment.

Our contributions are:

  1. We formulate multi-image ultrasound report generation as clinically aware evidence-grounded generation under partial visual observability.

  2. We introduce visual-evidence distillation, which decomposes raw reports into atomic points and retains visually supportable findings as positive image-grounded supervision.

  3. We propose CAMEO, a stage-wise clinically aware alignment framework that combines cross-view SFT with clinical-error-oriented preference alignment to balance evidence attribution, informative reporting, and clinically bounded generation.

  4. We introduce an evidence-grounded, LLM-assisted Clinical Error Evaluation protocol that measures whether generated reports are informative, diagnostically consistent, and bounded by trusted visible evidence.

References (22)