arXiv(opens in a new tab)cond-mat.mtrl-sciAug 2026

Manuscript Offprint

arXiv:2608.27162

Data-efficient crack quantification in lithium-ion cathodes using foundation model transfer

Thorsten Tegetmeyer-Kleine, Thomas Schmitt, Phillip Aquino, Christiane Rahe, Dirk Uwe Sauer, Weihan Li

Abstract

Battery lifetime is central to sustainable electrification, yet the particle cracking that drives lithium-ion cathode aging is hard to measure: quantitative microscopy of this degradation is bottlenecked by annotation, because each destructive electron-microscopy cross-section spans hundreds of megapixels and pixel-level expert labelling requires hours per image. We show that a frozen self-supervised vision-transformer encoder, combined with a lightweight trainable decoder and iterative model-assisted annotation, turns this sparse labelling budget into population-scale degradation measurements. Applied to three 120-megapixel NMC cathode cross-sections representing initial, cycled-aged and calendar-aged states, the framework distinguishes intragranular cracks from early- and late-stage intergranular cracks and yields per-particle distributions of crack width, tortuosity and area fraction. Late intergranular crack coverage reaches 4.6% in the cycled sample versus 0.5% in the initial and calendar-aged samples, forming more tortuous, higher-coverage networks, consistent with degradation from repeated electrochemical cycling rather than elevated-temperature

∗^{*}Corresponding authors.

Email addresses: thorsten.tegetmeyer-kleine@isea.rwth-aachen.de (Thorsten Tegetmeyer-Kleine), weihan.li@isea.rwth-aachen.de (Weihan Li) storage alone. A single destructive image yields the population-level statistics needed for lifetime-extending design, aging assessment and second-life decisions.

Keywords: data-efficient learning, foundation models, quantitative microscopy, crack morphometrics, NMC cathodes, model-assisted annotation

1. Introduction

Lithium-ion batteries are central to electrified transport and renewable-energy integration, yet electrochemical and chemo-mechanical degradation processes within their electrodes ultimately limit service life [1, 2]. Quantifying the mechanical cracking that accompanies this degradation is bottlenecked by destructive cross-sectional microscopy and labour-intensive expert annotation. In high-nickel layered oxide NMC cathodes, this degradation appears primarily as particle-level cracking: secondary particles composed of aggregated primary grains develop cracks that propagate along grain boundaries (intergranular) and through individual grains (intragranular) during cycling, calendar aging, and thermal stress [3]. These cracks expose fresh cathode surfaces to the electrolyte, catalyzing parasitic reactions, promoting cathode-electrolyte interphase growth, and accelerating transition-metal dissolution, collectively driving capacity fade and impedance rise [4, 5]. As cracking intensifies, secondary particles fragment entirely, causing loss of electronic contact and further capacity loss [6, 7]. Understanding crack initiation, propagation, and morphology is therefore central to diagnosing battery aging and guiding electrode design.

To quantify cracking reliably, one must first distinguish the underlying crack morphologies. Intergranular cracks propagate along grain boundaries between primary crystallites within polycrystalline secondary particles, yielding a fragmented, mosaic-like appearance, whereas intragranular cracks traverse individual grains and often align with the layered structure, running parallel to the (003) crystallographic planes [8]. Intragranular cracks are typically narrow (on the order of tens of nanometers) and may originate at dislocation cores before extending along mechanically weak lattice planes [9]. Under high-voltage operation, this intragranular mode is associated with pronounced surface reactivity, oxygen release, and the formation of a rock-salt surface layer in Ni-rich cathodes [10, 11]. Scanning electron microscopy (SEM) and X-ray microscopy can reveal such cracks ex situ, after cell disassembly and sample preparation (direct in situ imaging at comparable spatial resolution and contrast inside sealed cells is typically impractical). However, translating image contrast into quantitative, class-aware crack maps remains labor-intensive: large SEM images (e.g., 17k×7k17k \times 7k px) must be subdivided into tiles. In our experience, manual labelling can take up to 5 min per tile, amounting to several hours per image and introducing substantial inter-annotator variability [12, 13, 14].

Current imaging methods cannot simultaneously achieve high spatial resolution and track crack evolution over time. High-fidelity techniques such as FIB-SEM or nano-CT resolve fine microstructural details but are destructive, precluding subsequent cycling of the same specimen. Non-destructive modalities such as laboratory micro-CT enable repeated imaging over cycling but typically lack the spatial resolution needed to resolve small cracks. This trade-off motivates approaches that use information from destructive measurements to interpret non-destructive data.

Foundation-model transfer is well suited to this setting. Self-supervised vision-transformer encoders pretrained on natural-image corpora produce transferable mid-level features without domain-specific pretraining; recent encoders [15][15] preserve dense per-patch correlations and remain effective with a frozen backbone and a lightweight task-specific head [16][16]. In low-label scientific imaging, where expert annotation is the bottleneck, freezing the encoder concentrates the annotation budget on per-particle morphometric quantification rather than on encoder fine-tuning. The approach therefore fits destructive-microscopy domains in which each annotated tile is costly and the downstream question is morphometric rather than segmentation-overlap based.

The three crack classes correspond to morphological categories associated in the literature with distinct degradation mechanisms in NMC cathodes. Intragranular cracking has been linked to anisotropic lattice strain within primary particles during the high-state-of-charge H2→H3H2 \rightarrow H3 phase transition, often aligning with the lamellar (003) structure of the layered oxide [3, 10]. Early intergranular cracking propagates along grain boundaries under repeated mechanical stress from volume changes during cycling, while late intergranular cracking represents the developed network state; wider crack openings infiltrated by electrolyte decomposition products and the rock-salt surface layer characteristic of Ni-rich degradation [11, 9]. Resolving these three regimes from a single SEM cross-section therefore captures the chemo-mechanical degradation history at the particle level and supports mechanistic interpretation beyond the binary “cracked / not cracked” framing of single-class segmentation.

Deep learning-based segmentation, including variational autoencoder (VAE)-style and U-Net approaches, has accelerated automated analysis of battery microstructures, and recent lithium-plating work suggests that latent representations from autoencoder-style models can encode diagnostically relevant post-mortem image features [17]. By contrast, foundation-model encoders pretrained at scale provide richer and more transferable representations for downstream dense prediction [18, 15, 19]. However, across the key studies cited here, most contributions either target a single crack morphology or limited volumes (e.g., sub-volume analysis [20]), or they primarily advance general segmentation strategies rather than broad, multi-class crack mapping (e.g., multi-phase 3D segmentation [21], general-purpose segmentation frameworks [22, 23], or foundational encoder-decoder architectures [24, 25]). Multi-class crack typing across hundred-megapixel SEM images therefore remains an open problem, and foundation-model transfer pipelines for multi-class segmentation at this resolution in electron microscopy have not been reported. Recent foundation models for segmentation, including the Segment Anything Model (SAM [26]) and its successor SAM-2 [27], as well as CellPose [28] for biological microscopy, offer zero- or few-shot segmentation via interactive prompting. However, these models do not natively support class-discriminative multi-label prediction for semantically distinct sub-structures (e.g., early vs. late intergranular cracks), and their applicability to narrow, high-aspect-ratio structures in electron microscopy without task-specific fine-tuning remains limited.

Here we introduce a sparse-label morphometric-inference framework that turns frozen foundation-model representations into per-particle crack morphometrics from few expert annotations, making population-scale degradation diagnostics practical for battery-lifetime research. We freeze a self-supervised vision-transformer encoder [15] and train only a lightweight decoder [29] on the SEM labels. An iterative model-assisted annotation loop grows 79 hand-labelled SEM tiles into a 482-tile expert-corrected reference set across hundred-megapixel cathode cross-sections at three aging states. We resolve intragranular cracking and two stages of intergranular cracking, three categories linked in the literature to distinct degradation mechanisms, and read per-particle width, tortuosity and area fraction from the resulting class maps. Cycled-aged NMC cathodes show an approximately ninefold increase in late intergranular cracking, accompanied by more tortuous, higher-coverage crack networks, whereas calendar-aged samples remain near baseline. These morphometric differences are consistent with degradation associated with repeated cycling rather than elevated-temperature storage alone. Each cross-section yields hundreds of per-particle morphometric measurements, so the scientific findings come from these per-particle distributions rather than from pixel-overlap metrics.

References (49)