1^{1}Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, State Key Laboratory of Cardiovascular Diseases, NHC Key Laboratory of Ischemic Heart Diseases, National Clinical Research Center for Interventional Medicine, Key Laboratory of Viral Heart Diseases, Chinese Academy of Medical Sciences, Shanghai 200032, China.

2^{2}Institutes of Biomedical Sciences, Fudan University, Shanghai 200030, China.

3^{3}College of Biomedical Engineering, Fudan University, Shanghai 200438, China.

4^{4}Department of Cardiology, Shidong Hospital, Yangpu District, Shanghai 200438, China.

Technical Note – 6 October 2026

Abstract

Complete orthogonal predictive coordinates do not by themselves bind a latent direction to a named intervention. We present a mathematical and synthetic audit motivated by vascular device–vessel suitcordance. Capacity-matched least-squares predictors were exactly equivalent under complete fixed output transforms, whereas an anchor-only observer recovered interpretations only within the span of known perturbation signatures. Six three-dimensional configurations across 64 seeds gave a maximum paired prediction discrepancy of 6.7×10−156.7 \times 10^{-15} but a median untransported edit error of 1.513. Coordinate transport removed that error. Noisy and weak anchors constrained calibration stability, and changing the representation basis required recalibration or verified transport. Across 256 additional fits in dimensions 3–24, prediction equivalence persisted within 4.0×10−154.0 \times 10^{-15}. We then evaluated nine deliberate runnable fault classes across 64 seeds. All 576 faulty executions completed, but each violated at least one reconstruction, prediction, delivered-edit or scope contract; all 320 valid control records passed. Repeating a faulty implementation gave exact self-agreement despite error against the separately computed simulator expectation. For one omitted-direction defect, probe coverage followed its analytic law, and rank-aware abstention protected unsupported interpretations. Scalar-noise experiments exposed both missed weak faults and excessive rejection under narrow relative tolerances. These controls provide an executable separation of prediction, semantic support and scientific acceptance. They are synthetic numerical audits, not clinical validation, neural JEPA-Anything replication, agent learning or patient treatment-effect estimation.

Keywords: predictive representations; vascular digital twins; orthogonal factorization; intervention anchors; identifiability; device–vessel suitcordance; scientific verification; mutation testing

1 Introduction

Vascular digital twins must connect observed vessel states to interpretable responses if they are to support device selection or follow-up. Device–vessel suitcordance provides one motivating vocabulary: mechanical, cellular, and physicochemical–immune ecology describe complementary aspects of a device interacting with a vessel [1]. Imaging-based vascular digital twins offer another motivation for connecting measurements and longitudinal predictions [2]. These frameworks suggest useful scientific questions, but their labels cannot by themselves validate coordinates learned by a predictive model.

JEPA-Anything introduces orthogonal predictive factorization with learned projectors, factor-specific prediction, and state synthesis across multiple domains [3]. Its predictive and geometric objectives motivate examining the interpretation of a complete set of coordinates. The authors explicitly distinguish factor geometry from causal meaning. Here, we study the exact orthogonal linear boundary, where prediction-preserving changes of coordinates can be analyzed without neural optimization. Our study is an independent control audit rather than a reproduction of the reported neural results.

Related work makes verification central to scientific AI. ScienceIDE packages executable scientific acceptance rules [10]; ScienceBuddy connects procedural revision and model updates [11]; Discovery Foundation Models distinguish validated knowledge progress from future discovery capability [12]. We use these ideas to audit the acceptance rules themselves in a small mathematical system, without implementing their agents or training procedures.

The clinical distinction between prediction and intervention is consequential. In the nationwide Biomarker Research cohort of patients with acute myocardial infarction and Killip class III or IV, intra-aortic balloon pump (IABP) use was associated with higher in-hospital mortality; the investigators emphasized residual confounding and an observational interpretation [4]. This association cannot be assigned as a causal action label for a digital twin. We cite the cohort as a clinical motivation for preserving evidential boundaries and do not access its patient data or calibrate a simulator to its estimates.

Representation identifiability depends on observations and assumptions [5]. Temporal structure or known intervention targets can supply additional information under specified conditions [6, 7]. We restrict an observer to paired perturbation signatures in named and latent spaces. The audit asks what such anchors identify, how noise and weak signatures affect stability, and which executable checks distinguish a valid prediction from an unsupported named edit. We combine algebraic controls, ambiguity witnesses, dimensional stress tests and an explicitly constructed fault bank (Figure 1).