SR-TTA: Spatial-Redundancy Test-Time Adaptation for Interference-Robust Respiration Sensing

Jingyuan Liu, Zheng Chang, Haoqiu Xiong, Zhuangzhuang Cui, Sofie Pollin

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Jingyuan Liu ∗^{*} †^{\dagger}, Zheng Chang ∗^{*}, Haoqiu Xiong †^{\dagger}, Zhuangzhuang Cui †^{\dagger}, and Sofie Pollin †^{\dagger}

∗^{*}School of Computer Science and Engineering, University of Electronic Science and Technology of China, Chengdu, China

†^{\dagger}WaveCoRe, Department of Electrical Engineering (ESAT), KU Leuven, 3001 Leuven, Belgium

Abstract—Future 6G networks aim to expose sensing as a native service by reusing communication infrastructure. We study respiration sensing on a cell-free massive multiple-input multiple-output (MIMO) base station, where a 64-antenna channel must be fused into a breathing waveform. The state-of-the-art hand-crafted fusion is near-optimal in benign conditions. It collapses, however, under strong in-band motion interference, whose frequency falls inside the respiration band. We show that a learned complex-weight beamformer recovers respiration by spatial nulling, and that the remaining gap to a per-recording oracle can be closed at deployment by label-free test-time adaptation. Crucially, we identify which label-free signal makes this work. Frequency- and variance-based criteria cannot separate an in-band interferer from breathing. Our spatial-redundancy test-time adaptation (SR-TTA), which maximizes consistency across random antenna subsets under an out-of-band spectral veto, preserves benign performance in our tests. The respiration-rate error drops from 5.8 to 0.8 breaths per minute (bpm) under simulated in-band interference, and the pipeline maps onto the Open Radio Access Network (O-RAN) architecture as O-RAN distributed-unit (O-DU) range-gating, an adaptation xApp, and a calibration rApp. On real testbed recordings, a one-time cross-subject calibration plus SR-TTA reduces failures from 47% to 7%, drawing level with the hand-crafted combiner using label-free test-time adaptation.

Index Terms—integrated sensing and communication, sensing-native RAN, O-RAN, cell-free massive MIMO, respiration sensing, test-time adaptation, beamforming.

I. INTRODUCTION

Future 6G systems aim to provide environmental awareness as a native network capability [1]. Passive respiration sensing can reuse cell-free massive multiple-input multiple-output (MIMO) channel state information (CSI) without additional spectrum or hardware [2], [3]. Open RAN (O-RAN) offers a potential deployment substrate: its RAN Intelligent Controllers (RICs) host learned xApps for radio-unit energy saving [4] and cell-free resource orchestration [5].

The sensing chain reduces the high-dimensional CSI to a one-dimensional breathing waveform through a fusion front-end. State-of-the-art front-ends rely on hand-crafted physical signal processing: a range transform, weighted antenna combining (WAC) by breathing-to-noise ratio [2], and a frequency-separation rule based on the sensing-signal-to-interference ratio (SSIR) to reject interference (SSIR-WAC) [3]. These methods are near-optimal for a single, static subject. Real deployments, however, contain motion interference from a person turning over, walking slowly, or a moving pet. Such co-occurring activity is a recognized failure mode in wireless human sensing [6]. When the motion is slow, its frequency falls inside the respiration band (0.1–0.5 Hz); when it is also strong, both signal-to-noise weighting and frequency separation break down, because the interferer is indistinguishable from breathing by power or by frequency.

A natural response is to learn the fusion front-end. Deep models operating directly on CSI have become the workhorse of wireless sensing, from cross-domain gesture recognition [7] to CSI recovery and prediction [8]. Their known weakness is domain shift, as accuracy degrades on unseen subjects, geometries, and environments [7]. Test-time adaptation (TTA) offers a remedy by adapting the model at deployment without labels [9], [10], but its standard objectives are designed for classification, not waveform recovery.

Our approach exploits the spatial diversity of distributed antennas. BeamNet learns complex weights that can null interference through phase cancellation, unlike nonnegative scalar fusion. Label-free test-time adaptation refines these weights for each recording. The key question is which adaptation criterion distinguishes breathing from an in-band interferer: we use agreement across antenna subsets, rather than spectral concentration or dominant variance.

The main contributions of this paper are summarized as follows:

• We study respiration sensing on a cell-free massive-MIMO base station with eight distributed access points (APs), where strong in-band motion interference defeats hand-crafted fusion. The sensing pipeline maps onto standard O-RAN components, with range-gating at the O-RAN distributed unit (O-DU), adaptation as a near-real-time (near-RT) RIC xApp, and one-time calibration as a non-real-time (non-RT) rApp.

• We combine supervised BeamNet training with label-free SR-TTA. SR-TTA adapts the combiner per recording by maximizing consistency across random antenna subsets under an out-of-band spectral veto, without ground truth or an interferer detector, and we explain why frequency and subspace criteria cannot match it.

• Experiments show that the proposed front-end recovers respiration where SSIR-WAC collapses (absolute Pearson correlation ∣ρ∣|\rho| from 0.67 to 0.95, respiration-rate error from 5.8 to 0.8 bpm), repairs severe cross-domain shift on real recordings (failures 47%→7%47\% \rightarrow 7\%), and improves with the number of distributed APs while the frequency

Figure

Coverage area: distributed access points (APs) acting as O-RUs

Fig. 1. Considered scenario and proposed O-RAN embedding. Bottom: eight distributed APs surround a seated subject, and a second moving body adds an in-band interferer. Top: the pipeline mapped onto O-RAN, with range-gating (1) at the O-DU, BeamNet (2) and SR-TTA (3) as a near-RT RIC xApp, and one-time calibration as a non-RT rApp feeding the exposed respiration service.

baseline plateaus.