arXiv:2610.12337cs.CVOct 2026

Manuscript Offprint

arXiv:2610.12337

ContiLNN: Mitigating Slice Sampling Discontinuity with Liquid Neural Networks for Medical Image Restoration

Jialei He, Enhe Liu, Sifan Song, Pengfei Jin, Jionglong Su, Hongbin Wang, Zhixiang Lu, Yanhao Huang, Anteng Cai, Zhengyong Jiang, Jiaman Ding, S. Kevin Zhou, Jinfeng Wang

Abstract

Anatomical continuity provides complementary information for medical image restoration, yet exploiting neighboring slices requires accounting for both local anatomy and variations in slice sampling. We introduce ContiLNN, which augments two-dimensional restoration networks with bidirectional closed-form continuous-time (Bi-CfC) modules to model cross-slice context through liquid neural dynamics while retaining in-plane feature extraction. Slice-index intervals modulate gates determined by local features and hidden states, allowing propagation to respond to sampling variations and anatomical context. Closed-form updates avoid iterative numerical integration. Alongside reconstruction supervision, cross-slice consistency aligns first- and second-order intensity differences with high-quality references to preserve anatomical variation. Distillation from a frozen two-dimensional backbone helps retain in-plane fidelity. Across five training seeds, ContiLNN improves mean peak signal-to-noise ratio (PSNR) by 0.1907, 1.0176 and 1.2482 dB over the two-dimensional baseline for CT denoising, MRI super-resolution and reduced-count PET restoration, respectively, while reducing root mean squared error in all three tasks. On the held-out CT patient, PSNR improves consistently, with a standard deviation of 0.0026 dB across seeds; gains are greater for MRI and PET. PET ablations support ordered propagation beyond additional pointwise capacity. Under contiguous training, Bi-CfC achieves higher fidelity than a bidirectional gated recurrent unit (Bi-GRU) with similar parameter counts and arithmetic costs across all tested sampling conditions, with lower measured latency and memory use. We also investigate the performance of both operators under sparse and irregular context using mixed-gap training. Experiments with fewer training patients and a second backbone further support data efficiency and backbone compatibility.

Keywords: Medical image restoration, 2.5D restoration, Liquid neural networks, Slice-axis modeling

arXiv:2610.12337v1

1. Introduction

Medical image restoration seeks to recover anatomical information from acquisitions constrained by radiation dose, scan duration or signal availability. Lower-dose CT reduces radiation exposure at the cost of increased noise (McCollough et al., 2017; Moen et al., 2021). In MRI, higher spatial resolution competes with acquisition time and signal-to-noise ratio, motivating super-resolution methods that recover structural detail from lower-resolution observations (Chatterjee et al., 2024). In PET, lower administered tracer activity can reduce radiation exposure, and shorter acquisitions can reduce scan burden; both reduce detected counts, increasing noise and making local uptake differences harder to distinguish (Jang et al., 2024; Luo et al., 2022). These tasks estimate high-quality (HQ) images from low-quality (LQ) inputs. Advances in convolutional, Transformer and state-space networks have substantially improved in-plane recovery, providing efficient backbones for a range of medical restoration tasks (Zamir et al., 2022; Yang et al., 2026a; Chan et al., 2026; Yang et al., 2024; Chen et al., 2026; Yang et al., 2026b).

The anatomical evidence in a volume extends beyond any individual slice. Adjacent images sample structures that evolve along the slice axis, yet independent two-dimensional (2D) processing does not explicitly retain this ordered relationship (Fig. 1A). The imbalance between in-plane and through-plane information is a recognized challenge in volumetric medical image modeling (Dong et al., 2022).

A relevant clinical application arises when only a subset of slices from an existing image series is available for retrospective restoration. The available slices may be regularly or irregularly spaced in the original index sequence, so adjacent inputs need not correspond to consecutive slices in the source series. Their original indices preserve this distinction. This setting motivates cross-slice feature propagation that uses neighboring anatomy while accounting for the index gaps between available

∗^{*}Corresponding authors.

Email address: Jf.Jacob.Wang@gmail.com (Jinfeng Wang)

1^{1}Jialei He and Enhe Liu contributed equally to this work.

Preprint submitted to Medical Image Analysis

October 9, 2026

(A) Slice-wise 2D restoration omits ordered context

Independently sampled 2D slices

Figure

CT volume reconstructed from ordered axial slices

Independent slice sampling omits ordered context.

(B) Liquid neural dynamics along the slice axis

Backward liquid state update

h⃗t=Φ(et,h⃗t−1,δt),δt=gt/K(t≥1)\vec{h}_t = \Phi(e_t, \vec{h}_{t-1}, \delta_t), \quad \delta_t = g_t / K (t \geq 1)

br=Φ(eK−1−r,br−1,δK−1−r),h‾t=bK−1−tb_r = \Phi(e_{K-1-r}, b_{r-1}, \delta_{K-1-r}), \quad \overline{h}_t = b_{K-1-t}

Bidirectional liquid dynamics propagate slice-axis context

ordered window positions t

e; per-slice feature

h; liquid hidden state

(C) Restoration with ordered slice sequences

Input / LG sequence

xt=[xt0,…,xtK,t]x_t = [x_{t_0}, \ldots, x_{t_K}, t]

Restored sequence

yt=b⃗t0,…,ytK,ty_t = \vec{b}_{t_0}, \ldots, y_{t_K}, t

All slices restored with slice-axis context

Figure 1: Ordered-slice restoration with ContiLNN. (A) Independent 2D processing. (B) Bidirectional liquid propagation. (C) One restored output per observed slice. Original slice indices iti_t identify the KK inputs xitx_{i_t} and outputs y^it\widehat{y}_{i_t}; tt denotes window position. The direction-specific closed-form continuous-time (CfC) update Φ\Phi propagates states hth_t using features ete_t and normalized intervals δt\delta_t derived from gaps gtg_t. The backward traversal state brb_r is realigned to the original order; interval conventions and alignment are defined in Eqs. 4 and 10.

observations, with a restored output retained at each supplied position.

Local 2.5D modeling combines in-plane feature extraction with information from neighboring slices. Three-dimensional (3D) restoration networks instead model context through volumetric feature maps, as in convolutional models for MRI super-resolution (Chatterjee et al., 2024) and Spach Transformer for PET denoising (Jang et al., 2024). Storage for these feature maps scales with their spatial extent and channel width. Neighboring CT slices have also been incorporated into convolutional encoder-decoders (Shan et al., 2018). Adjacent-slice supervision and multi-view inference provide further ways to use through-plane information (Zhang et al., 2021; Chen et al., 2025). These approaches establish several roles for local anatomical context. ContiLNN represents this context as an evolving sequence of feature states, with an explicit slice-index interval and a restored output at every supplied position.

Liquid neural networks provide a continuous-time model of input-dependent state evolution (Hasani et al., 2021). Closed-form continuous-time networks (CfCs) approximate this evolution through interval-dependent updates without repeated numerical integration (Hasani et al., 2022). Their explicit interval input is particularly relevant when the separation between observations varies. For medical image restoration, we propagate states in slice order and condition each update on a normalized slice-index interval. Forward and backward states then communicate information between preceding and following observations (Fig. 1B). This links the anatomical ordering of the input to the dynamics used to refine its features.

Here we introduce ContiLNN, which augments 2D restoration backbones with bidirectional liquid dynamics along the slice axis. Each local sequence retains the correspondence between its input slices and restored outputs (Fig. 1C). Bidirectional CfC (Bi-CfC) modules propagate context at selected levels of the feature hierarchy, while two complementary regularizers guide the resulting images: cross-slice consistency preserves first- and second-order intensity changes in the HQ sequence, and distillation from a frozen 2D backbone retains agreement with its in-plane estimates. We develop this design on Restore-RWKV (Yang et al., 2026a) and apply it to DAS-Mamba (Chan et al., 2026) to examine compatibility with a second backbone.

Our contributions are threefold:

  1. Liquid dynamics for medical image restoration. We introduce ContiLNN to propagate anatomical information across ordered slices through bidirectional liquid dynamics. Slice-index intervals condition the closed-form updates, allowing state propagation to respond to sampling changes.

  2. Augmentation of 2D restoration backbones. Bi-CfC modules refine selected feature pathways while retaining the backbone’s in-plane blocks. Cross-slice intensity consistency and 2D backbone distillation jointly preserve reference anatomical variation and in-plane fidelity.

  3. Evaluation across modalities and sampling settings. CT, MRI and PET experiments assess restoration quality. Case-level analyses, comparisons of two operators under regular, sparse and irregular sampling, limited-patient training, backbone studies and ablations assess sampling adaptation, data efficiency and backbone compatibility.

References (44)