Manuscript Offprint
arXiv:2610.09185One Frame, Full Heartbeat: ECG-Free 4D Cardiac Cine MRI Synthesis via Radial-Decomposed Flow Matching
Highlights
• ECG-free 4D cardiac cine MRI synthesis from a single ED 3D volume.
• Piecewise linear cardiac phase with a canonical template for fully blind inference.
- Radial Contraction Decomposition combines a physics prior with a learned residual and directly warps the real ED volume.
• Synthetic supervision retains 99.2% of real-supervision segmentation Dice.
• Best EF accuracy, only positive volume-curve , and best FID/FVD on ACDC and M&Ms.
One Frame, Full Heartbeat: ECG-Free 4D Cardiac Cine MRI Synthesis via Radial-Decomposed Flow Matching
Shiyi Wang , Ruochen Sun , Xiang Li , Peirong Liu and Fangxu Xing
Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, USA
Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
Center for Advanced Medical Computing and Analysis, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
ARTICLE INFO
Keywords:
Deep learning
Sequential image data generation
Flow matching
Deformation-based synthesis
Radial contraction
ABSTRACT
Cine cardiovascular magnetic resonance (CMR) captures the full cardiac cycle as a four-dimensional (4D) sequence, but standard acquisition depends on electrocardiogram (ECG) gating and repeated breath holds, which is difficult in uncooperative populations, resource-limited settings, and temporally corrupted datasets. Existing synthesis approaches prioritize visual realism, which alone does not establish accurate patient-specific ejection fraction (EF) or ventricular volumes. We present PhaseFlow3D, a generative framework that synthesizes a complete 4D cine sequence from a single end-diastolic (ED) three-dimensional (3D) volume without ECG dependency. To capture the asymmetric dynamics of systole and diastole, PhaseFlow3D encodes the cardiac cycle as a piecewise linear phase anchored at the ED and end-systolic (ES) time points; at inference, this phase is instantiated from a population-level canonical template, requiring no patient-specific temporal information. Conditioned on this phase, a rectified flow model synthesizes a cardiac motion trajectory in latent space. A Radial Contraction Decomposition then decodes each latent state into a 3D displacement field, combining a physics-informed radial component for centripetal myocardial contraction with an image-conditioned residual for rotation and out-of-plane motion. Every frame is generated by directly warping the ED volume, bypassing variational autoencoder decoding. On the combined ACDC and M&Ms benchmark, PhaseFlow3D achieves the best EF mean absolute error, the only positive left-ventricular volume-curve , and the best distributional quality among all compared methods, with ablations confirming the contribution of each component. Downstream evaluations further confirm the utility of the synthesized sequences and their displacement fields in segmentation, pathology classification, label propagation, and myocardial strain analysis.
1. Introduction
Cine cardiovascular magnetic resonance (CMR) imaging is the clinical gold standard for quantifying ventricular anatomy and function [1, 2], enabling precise physiological measurements throughout the complete cardiac cycle such as ejection fraction (EF), end-diastolic (ED) and end-systolic (ES) volumes, myocardial strains, etc. In standard clinical practice, a full four-dimensional (4D) CMR acquisition often requires electrocardiogram (ECG) gating and multi-breath-hold pulse sequences, a protocol unavailable in retrospective cohort studies, prohibitively costly in resource-limited settings, challenging for uncooperative population, and inapplicable when only isolated three-dimensional (3D) volumes survive archiving. Therefore, the problem of synthesizing a complete, physiologically coherent 4D cine CMR sequence from a single 3D volume is both clinically compelling and technically formidable: it demands recovering the full spatiotemporal trajectory of 3D myocardial deformation from purely spatial information, without any explicit temporal signal. Beyond restoring the missing temporal dimension, synthesizing the full sequence from a single volume would enable quantitative motion analysis from the recovered displacement field, support data augmentation for data-scarce downstream tasks such as segmentation and disease classification, and, since every generated sequence carries a known deformation field, provide ground-truth benchmarks for validating deformable registration algorithms.
Prior work provides several approaches to cardiac motion modeling and synthesis. Pairwise registration methods such as VoxelMorph [3] estimate deformations between observed images. Krebs et al. [4] additionally learn a
Corresponding author
swang103@mgh.harvard.edu (S. Wang); rsun6@mgh.harvard.edu (R. Sun); xli60@mgh.harvard.edu (X. Li); peirong@jhu.edu (P. Liu); fxing1@mgh.harvard.edu (F. Xing)
ORCID(s):
S. Wang et al.: Preprint submitted to Elsevier
Page 1 of 29 temporally regularized probabilistic motion model that supports motion simulation from an ED image. Temporal and regional motion modeling is also central to cardiac tracking methods such as GPTrack [5]; separate studies of learning-based registration identify limitations in cross-domain generalization [6]. Deformation-based generators such as DragNet [7] predict displacement fields autoregressively from a single frame. This removes the target-frame requirement, although recurrent predictions may accumulate error over long sequences. ECG-conditioned methods [8, 9] use ECG as a temporal conditioning signal, requiring an ECG input at inference that may be unavailable in retrospective or resource-limited settings. Video generators based on generative adversarial networks (GANs) [10] and diffusion models [11, 12] offer further synthesis strategies, as surveyed in [13]. Cardiac applications include physiological attribute editing [14], multimodal structural and motion conditioning [15], and ED semantic-map conditioning [16]. Conditional image leakage has also been identified as a source of insufficient motion in image-to-video diffusion [17], underscoring the need to evaluate dynamics alongside image appearance. Visual realism alone does not establish the accuracy of patient-specific EF or left-ventricular (LV) volumes. We therefore target single-volume 4D cine synthesis with explicit supervision of EF and the LV volume trajectory.
Our temporal conditioning strategy uses cardiac phase to explicitly align ED and ES across subjects. This compact representation accommodates the different durations of systole and diastole [18] without an ECG input. Exploiting this phase signal to synthesize a complete 3D volumetric cine sequence from a single ED volume, however, is not straightforward; it raises three challenges. First, the motion to be synthesized becomes a dense 3D displacement field, whose coordinated volumetric motion is not explicitly constrained by independent per-slice warps. Second, the computational and memory cost of jointly modeling voxels precludes naive 4D architectures. Third, physiological supervision must act on volumetric quantities (EDV, ESV, EF) rather than per-slice areas, and must do so without ever running a segmentation network on synthesized images.
We present PhaseFlow3D, a generative framework that synthesizes a complete 4D cine CMR sequence from a single ED 3D volume. At its core, an ECG-free cardiac phase drives a latent flow-matching architecture. The phase is piecewise linear with breakpoints at the known ED and ES timings, encoding each frame as . At inference, a population-level canonical template replaces the per-patient timing, enabling fully blind synthesis with no ECG, gating, or pathology label. Conditioned on this phase, a rectified flow model [19] is trained on straight interpolations between the ED anchor's latent features and the full-sequence latent features . At inference, we evaluate the velocity network once at the anchor and decode its output into the motion sequence. A D'-fold trick then folds the compressed depth axis into channels, so 4D reasoning runs at 3D computational cost. Each predicted latent velocity is decoded through a Radial Contraction Decomposition: a physics-informed radial component encodes centripetal LV contraction through an anatomy-derived direction field, ED anchoring, phase-conditioned temporal modulation, and anatomical localization, while an image-conditioned residual decoder synthesizes the remaining non-radial motion. The total displacement field warps the ED volume directly into every output frame. Output intensities are interpolated from the real scan, bypassing variational autoencoder (VAE) [20] decoding.
Our main contributions are:
-
An ECG-free cardiac phase for single-volume synthesis. A piecewise linear cardiac phase anchored only at ED and ES replaces the ECG signal, and a population-level canonical template supplies these timings at inference, enabling fully blind synthesis from a single ED volume.
-
Radial Contraction Decomposition. Cardiac motion is decomposed into a physics-informed radial component and a data-driven residual, and every frame is synthesized by warping the real ED volume, bypassing VAE decoding. To our knowledge, this is the first use of a radial decomposition as a structural prior in a generative synthesis framework.
• Physiological supervision without segmenting synthesized images. EF and volume-curve losses are computed by warping the ground-truth ED mask through the predicted displacement field, so segmentation runs only on real images and clinically relevant metrics supervise training without domain shift.
• Validated downstream utility. Five downstream experiments show utility beyond visualization: synthetic supervision can largely substitute for real supervision in segmentation and pathology classification, and the recovered displacement fields support label propagation and blind myocardial strain analysis.
The remainder of this paper is organized as follows. Section 2 reviews related work on cardiac motion synthesis. Section 3 details the proposed framework. Section 4 presents the experimental setup, comparisons with state-of-the-art
S. Wang et al.: Preprint submitted to Elsevier
Page 2 of 29 baselines, and ablation studies. Section 5 evaluates the utility of the synthesized sequences and their displacement fields in five downstream applications. Section 6 discusses the physiological findings and the limitations of the method, and Section 7 concludes the paper and outlines directions for future work.
2. Related Work
Cine CMR synthesis. Prior cine synthesis methods differ in their conditioning inputs and motion representations. VoxelMorph [3] estimates pairwise deformations, whereas the probabilistic motion model of Krebs et al. [4] also supports sampling motion from an ED image and computing LV volume curves from warped ED masks. Its normalized time input does not itself impose constant motion velocity. DragNet [7] predicts displacement fields autoregressively from a single frame without a target image or ECG input; recurrent prediction may accumulate error over long sequences. ECG-conditioned models [8, 9] use an ECG input to guide video generation. GANcMRI [14] explores physiological attribute control through latent-space prompting, while echocardiographic diffusion models use structural and motion conditions [15] or an ED semantic map [16]. CardioDiT [21] jointly models space and time in a latent diffusion transformer and evaluates volumetric cardiac function in unconditional 4D CMR generation; its reported experiments do not address conditioning on a single observed volume. PhaseFlow3D targets this conditional setting with explicit EF and volume-curve supervision and parallel, phase-conditioned deformation prediction. Section 4.1 describes our baseline adaptations.
Flow matching and video prediction. Flow matching [22] and rectified flow [19] learn continuous transport fields, with rectification providing a route toward efficient sampling. Straight training interpolations alone do not guarantee an exact single-step inference trajectory. Separately, SF-V [23] obtains single-forward-pass video generation by adversarially fine-tuning a pretrained video diffusion model. EchoLVFM [24] uses MeanFlow-based latent video generation conditioned on observed echocardiographic frames and a target EF. Its 2D ultrasound setting and EF-conditioned input differ from our single-volume CMR setting, which requires no target EF at inference. General-purpose video prediction models such as SimVP [25] and latent flow diffusion models (LFDM) [26] deliver strong pixel-level fidelity on natural videos. Their original formulations do not include cardiac EF or volume-curve supervision; our experiments evaluate their physiological accuracy when adapted to single-volume cardiac synthesis.
Diffeomorphic deformation in medical imaging. Scaling-and-squaring integration [27] provides a computationally efficient route to diffeomorphic transformations. VoxelMorph [3] established a learning-based framework for deformable registration. Dalca et al. [28] developed a probabilistic diffeomorphic registration model evaluated on 3D brain MRI, while earlier work incorporated incompressibility constraints for cardiac tissue tracking [29]. PhaseFlow3D uses velocity integration in its generative residual decoder. The residual is combined additively with a radial displacement, so the regularity of the total transformation is evaluated numerically rather than inferred solely from the residual parameterization.
Physics-informed cardiac motion priors. LV motion includes radial contraction, longitudinal shortening, and rotation [30]. We use a radial field defined relative to the LV centroid as a simplified anatomical prior rather than a complete biomechanical model. Prior registration methods incorporate tissue incompressibility through constrained deformation models: iLogDemons [29], for example, imposes a divergence-free velocity constraint. Tissue incompressibility does not imply a constant LV cavity volume. Our radial branch encodes an anatomy-derived direction within a generative decoder, while a learned residual represents rotation, shear, and out-of-plane motion.
3. Methodology
We leverage the generative nature of latent rectified flow matching [19], in combination with a physics-informed Radial Contraction Decomposition, to introduce PhaseFlow3D for 4D cine synthesis from a single ED volume. Here, the purpose of PhaseFlow3D is to predict a phase-conditioned latent velocity and decode it into a 3D displacement field , which warps the ED volume into each synthesized frame . The temporal structure comes from a piecewise linear cardiac phase with breakpoints at ED and ES, so that no ECG or per-patient temporal signal is required. Note that this phase can be instantiated either from ground-truth ED and ES landmarks or, for fully blind inference, from a population-level canonical template (Sec. 3.2). Details of the method are described in the following, including the task
S. Wang et al.: Preprint submitted to Elsevier
Page 3 of 29 formulation, the phase conditioning, the latent encoding, the phase-conditioned flow matching, the radial displacement decoding, and the network architecture and implementation (Sec. 3.8).
3.1. Problem Formulation
Let denote the single 3D ED CMR volume, with slices and in-plane resolution. The synthesized 4D cine sequence (frame index , with the number of frames in the cardiac cycle, each ) must be both perceptually realistic and physiologically faithful. This task is fundamentally underdetermined: a single ED volume does not uniquely specify the subsequent contraction trajectory. CMR functional assessment uses measurements across the cardiac cycle [31]; in echocardiography, video-based models likewise exploit temporal information for functional assessment [32]. We supply a piecewise linear cardiac phase as a temporal prior (Sec. 3.2), without assuming that it identifies a patient's unique true motion from the ED anatomy alone.
3.2. Piecewise Linear Cardiac Phase
Providing a temporally structured conditioning signal without ECG is the central obstacle to single-volume cine synthesis. We parameterize the cardiac cycle by a piecewise linear phase with breakpoints at the two physiologically meaningful landmarks of the cycle, ED and ES.
Phase definition. Let and denote the frame indices of end-diastole and end-systole, respectively. The cardiac phase is defined as
so that , , and . Each frame is then encoded as , a compact, periodicity-aware representation. During training, the ED and ES positions come from ground-truth annotations.
Why piecewise linear? Systole and diastole occupy different portions of the cardiac cycle, with durations that vary with physiological conditions [18]. A uniform linear phase uniformly spaces frames but does not explicitly align ES across subjects (Figure 1, top). The piecewise linear phase instead maps ES to by construction, allocating a fixed phase interval to each part of the cycle (Figure 1, bottom). This aligns temporal landmarks; the learned deformation model determines the motion velocity within each interval.
Canonical phase for fully blind inference. At inference, only the ED volume is available and is unknown. For each training subject , let the ES fraction be , the position of ES as a fraction of that subject's cycle length. We pre-compute the population-average fraction over the training subjects, and define the canonical phase template
The approximation error introduced by the canonical template is quantified in Sec. 4.4.
3.3. CineVAE3D: Per-Frame 3D Encoding
A pretrained, frozen CineVAE3D encoder constructs the latent space. Rather than encoding an entire sequence jointly,

Piecewise Linear Phase (ours)

Figure 1: Uniform linear phase (top) scatters ES across values; the piecewise linear phase (bottom) aligns ES at by construction across pathological types.
S. Wang et al.: Preprint submitted to Elsevier
Page 4 of 29
CineVAE3D encodes each 3D frame independently:
where is the number of latent channels and are the compressed depth and in-plane sizes, so the full-sequence latent is . The encoder uses true 3D convolutions with per-frame 2D spatial attention at the bottleneck. The anchor latent is built from the ED volume repeated times with a small additive perturbation:
where denotes expansion along the temporal dimension. This division of labor is deliberate: the VAE specializes in spatial representation, while all temporal dynamics of the transport from to are delegated to the flow-matching model.
3.4. Phase-Conditioned Latent Flow Matching
We formulate 4D cine synthesis as conditional transport in the shared latent space using rectified flow [19].
Rectified flow. Given a uniformly distributed flow time , the interpolated latent feature at is . Differentiating with respect to gives the ground-truth feature velocity , which is constant along each sampled training interpolation. A VelocityUNet4D is trained to predict this velocity, conditioned on the flow time and the phase tokens :
where is our proposed per-frame phase embedding produced by a small multilayer perceptron (MLP; the PhaseProjector) from and injected at every resolution level via cross-attention [33], enabling spatially adaptive phase conditioning. The global condition for adaptive group normalization (AdaGN) [34] is taken as the temporal mean of .
VelocityUNet4D and the -fold trick. The second obstacle to single-volume cine synthesis is computational: naive 4D convolutions over the full latent grid are prohibitively expensive in both memory and compute. We resolve this by exploiting the fact that the VAE has already compressed the depth axis to only slices, which is shallow enough to fold into the channel dimension without inflating the network. Folding the depth slices into the channel dimension turns the 4D problem into a 3D one over , with the depth slices mixed through the channel weights. The folded tensor is processed by a 3D U-Net backbone and unfolded back to the 4D latent after each resolution level. All attention blocks thus operate without modification, and full 4D reasoning is achieved at the cost of a 3D network. To enable cross-frame reasoning, each resolution level incorporates a temporal attention block that exchanges information across all T frames simultaneously, allowing the model to synthesize temporally coherent motion rather than processing each frame independently. At inference, we evaluate the velocity network once at the ED-conditioned anchor: , and decode its output directly into the motion sequence without iterative ordinary differential equation (ODE) integration. This single-evaluation scheme is an inference design choice evaluated in our experiments; the constant target velocity on training interpolations does not imply that the learned field is constant along its inference trajectories.
3.5. Radial Contraction Decomposition
The predicted latent velocity must be decoded into a physiologically meaningful 3D displacement field. Instead of an unconstrained decoder, we decompose the displacement into two complementary components:
where the radial component provides a simplified prior for LV contraction and the residual models additional motion. Throughout, denotes the backward sampling map used by the spatial transformer (Sec. 3.6): the output voxel at location draws its intensity from location in the ED volume. Under this convention, a sampling displacement directed away from the LV centroid retrieves intensities from larger radii, so the rendered tissue moves toward the centroid.
S. Wang et al.: Preprint submitted to Elsevier
Page 5 of 29
Radial component (physics-informed prior). Radial contraction is one component of the complex LV motion, alongside longitudinal shortening and rotation [30]. We approximate this component with a unit direction field defined relative to the LV centroid. We define the radial direction field as
where is a voxel coordinate, is the LV centroid, is a small constant that prevents division by zero, and is a dilated binary LV mask that confines the radial field to the cardiac region. The radial displacement at frame is then
where is a patient-specific global amplitude derived from the ED image features via global average pooling, with the sigmoid function and an upper bound on the radial amplitude; is a spatially adaptive modulation map weighting the radial contribution across myocardial regions; and is a temporal activation curve, where peak_norm rescales it to unit peak so that at ED and at the systolic peak. This branch incorporates four design properties: (1) a radial direction prior: for nonnegative , the sampling displacement points away from the centroid, which renders centripetal tissue motion under the backward-sampling convention; (2) ED identity: enforces ; (3) continuous temporal modulation through the phase-conditioned sigmoid-MLP parameterization; and (4) spatial localization: confines radial motion to the cardiac region.
Residual component. The residual is decoded from by an ImageConditionedDeformDecoder3D, whose upsampling layers receive skip-connected multi-scale features of the ED volume from a lightweight ImageEncoder3D:
Scaling-and-squaring integration [27] with K steps approximates the flow of a stationary velocity field, providing a diffeomorphic parameterization in the continuous setting. Finite-step integration and discrete interpolation do not give an unconditional guarantee of positive Jacobian determinants. Moreover, adding the radial displacement does not preserve such a guarantee for the total field. We therefore assess its folding rate empirically in Sec. 4.5. Throughout, denotes the Jacobian of the coordinate transformation , namely , rather than the derivative of the displacement alone. The skip connections ground the residual in patient anatomy: the decoder observes the actual ventricular boundaries when synthesizing non-radial motion such as rotation, shear, and out-of-plane deformation.
Residual regularization. To discourage the residual from canceling the radial component, we penalize its projection onto the radial direction:
encouraging the radial head to account for radial contraction.
3.6. Warp-Based 4D Synthesis
Given the total displacement , each output frame is synthesized by directly warping the ED volume:
where warp is a differentiable 3D spatial transformer with trilinear grid sampling [35], evaluating at every output voxel . The map therefore sends frame-t coordinates to ED coordinates. Forward tissue motion corresponds to the inverse of this map, a distinction the strain analysis accounts for by inverting the deformation gradient (Sec. 5.4). Every synthesized voxel is an interpolation of the real ED volume, and no VAE decoder participates in the output synthesis path. This anchors image appearance to the observed anatomy and requires temporal variation to be expressed through a displacement field. It does not eliminate interpolation error or guarantee anatomically correct motion; the physiological losses and deformation regularization constrain the predicted fields. The effect of replacing this warp-based synthesis with VAE decoding is evaluated in Sec. 4.3 (A1).
S. Wang et al.: Preprint submitted to Elsevier
Page 6 of 29
3.7. Training Objectives
PhaseFlow3D is trained end-to-end with a composite objective that combines a core flow-matching term in the latent space, an image-space fidelity term, and a set of physiological and anatomical constraints. Each component is described below, and the terms are weighted into a single total loss.
Flow matching loss. The standard rectified flow matching objective, evaluated in latent space:
where E denotes the expectation over the flow time and the sampled training latent pair .
Local normalized cross-correlation. An image-space registration loss between each warped ED volume and the corresponding ground-truth frame , robust to intensity offsets:
computed over local windows on each 2D slice of the volume.
Deformation regularization. The bending energy [36] penalizes second-order spatial derivatives of the displacement field, extended to 3D:
The folding loss penalizes topology violations only, without forcing the Jacobian determinant toward unity, as this would contradict the physiological volume change of the LV cavity:
where denotes the spatial mean, so that only folded voxels with a negative Jacobian determinant are penalized, and is computed via 3D finite differences.
ED identity loss. The displacement at the ED frame must vanish:
where is the binary LV mask at ED, Dice is the soft Dice overlap, and is the norm, jointly penalizing mask misalignment and non-zero displacement at ED.
ES endpoint supervision. Explicit supervision at the end-systolic frame anchors the contraction magnitude:
where 1 – Dice is the soft Dice term evaluated at ES, is the end-systolic LV volume, and , are scalar weights. Predicted volumes and EF are obtained by warping the ground-truth ED segmentation mask through the predicted displacement field, so that no segmentation network ever runs on generated images.
Volume curve loss. Dense temporal supervision over the full LV volume trajectory:
where is the per-frame normalized volume error, is computed between the predicted and ground-truth volume curves, penalizes amplitude mismatch, and penalizes systematic volume offset. The predicted volume at frame is obtained by warping the frozen SegUNet's soft ED mask through ; ground-truth volumes come from SegUNet applied to real frames. During training, the frozen SegUNet thus processes only real CMR images, so domain shift is avoided and gradients remain reliable, flowing through the differentiable warp back to the velocity network.
Therefore, the total loss combines flow-matching, image-space, and physiological terms:
where each is a scalar weight balancing the corresponding term.
S. Wang et al.: Preprint submitted to Elsevier
Page 7 of 29

Figure 2: PhaseFlow3D encodes the ED 3D volume into a latent anchor , predicts a phase-conditioned latent velocity via rectified flow matching, and decodes a 3D displacement field through a Radial Contraction Decomposition. The displacement field directly warps the ED volume to synthesize the full 4D cine sequence.
3.8. Network architecture and implementation
As Figure 2 illustrates, PhaseFlow3D consists of six components that transport the single ED volume into the full 4D cine sequence:
-
CineVAE3D encoder ( , frozen): a per-frame 3D VAE that maps each frame (1, D, H, W) to a latent (4, , h, w) = (4, 4, 16, 16). It encodes the ED volume into the anchor latent (Eq. (4)), using 3D convolutions with per-frame 2D spatial attention at the bottleneck.
-
PhaseProjector: a small MLP that maps each phase code to a per-frame embedding . The embedding is injected at every resolution level through cross-attention.
• VelocityUNet4D ( ): a 3D U-Net (base channels 128, multipliers [1,2]) that predicts the latent velocity (Eq. (5)). It combines temporal attention across frames, per-frame spatial attention, AdaGN residual blocks, and phase cross-attention ( , ). The D'-fold trick folds the depth axis into channels, so full 4D reasoning runs at the cost of a 3D network.
-
RadialContractionHead: the physics-informed head that produces the radial displacement (Eq. (8)). A GlobalNet pools the ED features into the patient amplitude , a LocalNet outputs the spatial modulation map , and a TemporalNet outputs the activation curve .
-
ImageEncoder3D and ImageConditionedDeformDecoder3D: the data-driven pathway that decodes the residual displacement (Eq. (9)). A lightweight ImageEncoder3D (channels [16, 32, 64]) supplies multi-scale skip features of the ED volume to the transposed-convolution decoder, and a ScalingSquaring3D layer (K = 7) integrates the residual velocity field.
-
SpatialTransformer3D: a differentiable warp with trilinear sampling that deforms the ED volume by the total field to synthesize each frame (Eq. (11)).
The full framework is implemented in Python and PyTorch. A frozen 2D SegUNet supplies segmentation masks for the physiological losses during training only, and never processes generated images. Complete layer specifications and hyperparameters are given in Appendix B.
4. Experiments and Results
4.1. Experiment Setup
Datasets. We trained and evaluated on two publicly available cardiac CMR datasets, which are ACDC and M&Ms. ACDC [37] contains 150 subjects from five pathological groups: normal control (NOR), dilated cardiomyopathy (DCM), hypertrophic cardiomyopathy (HCM), prior myocardial infarction (MINF), and abnormal right ventricle (ARV), with 30 subjects per group. Each subject includes a cine CMR sequence with ED/ES annotation. We split the dataset into 105 training subjects, 15 validation subjects, and 30 test subjects in a stratified manner, with the five
S. Wang et al.: Preprint submitted to Elsevier
Page 8 of 29 pathological groups evenly distributed across all splits. M&Ms [38] is the Multi-Centre, Multi-Vendor & Multi-Disease dataset acquired on four scanner vendors across multiple clinical centres; we retained the challenge split assignments for the included cases, using 150 labeled training, 34 validation, and 136 testing subjects. The model was trained jointly on the ACDC and M&Ms training subjects (255 subjects in total) and evaluated on the combined ACDC and M&Ms test sets. All volumes were resampled to D = 16 slices, H = W = 128 in-plane, T = 30 frames per cycle, and normalized to .
Implementation. CineVAE3D was pretrained for 100 epochs with a learning rate of and KL weight of , and frozen during flow training. The frozen SegUNet is a standard 2D U-Net [39] trained on ACDC segmentation annotations for the LV, right ventricle (RV), and myocardium, used for ED/ES mask extraction and volume-curve computation; during training it was never exposed to generated images. The network architecture and its layer dimensions are specified in Sec. 3.8, with full details in Appendix B. At inference, the canonical phase template with population-average ES fraction was used (Sec. 3.2).
Training. PhaseFlow3D was trained in two progressive stages. The full two-stage schedule took approximately 29 hours on a single NVIDIA RTX A6000 GPU. Jointly optimizing all components from scratch is unstable, because the flow-matching network can learn spurious shortcuts before the radial head has established a correct contraction prior. In Stage 1 (50 epochs), only the RadialContractionHead and PhaseProjector were trainable, while the velocity network and deformation decoder stayed frozen. The loss was restricted to the physiology terms ( ), so the radial head learned the correct contraction direction and amplitude before any image-level gradient biased the temporal curve. In Stage 2 (100 epochs), the VelocityUNet4D, ImageEncoder3D, and deformation decoder were unfrozen, and all terms of Eq. (19) were active with physiology-biased weights. The best checkpoint (epoch 60) was used in all experiments. Both stages used AdamW [40] with of 0.9, of 0.999 and weight decay of , learning rate with cosine annealing to , batch size 1, and mixed-precision training.
Evaluation metrics. We organized evaluation into two categories:
- Image and video quality: Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure [41] (SSIM), Learned Perceptual Image Patch Similarity [42] (LPIPS), Fréchet Inception Distance [43] (FID), and Fréchet Video Distance (FVD) [44], computed on full synthesized sequences to measure temporal distributional quality.
• Physiological fidelity: Ejection Fraction Mean Absolute Error (EF MAE), Volume Curve Pearson Correlation (Vol Corr), Volume Coefficient of Determination (Vol ), Volume Mean Absolute Error (Vol MAE).
Formal definitions and the motivation for each metric are given in Appendix D.
4.2. Comparison to Baselines
In this experiment, we evaluated the model performance on the combined ACDC and M&Ms test set, which spans five pathology groups and multiple scanner vendors. Table 1 shows the performance of the proposed model (PhaseFlow3D) compared with seven other state-of-the-art techniques on the test sequences in terms of image and video quality (PSNR, SSIM, LPIPS, FID, and FVD) and physiological fidelity (EF MAE, Vol Corr, Vol , and Vol MAE). All seven baselines were retrained on this split under identical data conditions, while ECG-conditioned methods [8, 9] and registration methods [3] were excluded, as the former require an ECG input that violates our ECG-free setting and the latter require a target frame at inference rather than synthesizing from a single ED volume. DragNet, a published method in the ECG-free, single-frame setting, was reproduced in its native 2D modality because our whole-volume 3D adaptation collapsed the predicted displacement toward zero when the static background dominates the reconstruction loss; we therefore ran the unmodified 2D model one short-axis slice at a time and resampled the stacked volumes to the shared frame count T, placing it in the same evaluation harness as every other method under a like-for-like comparison.
The results indicate that PhaseFlow3D reproduces cardiac physiology far more faithfully than the competing methods. Its EF MAE of 12.85% roughly halved that of the best competing method (27.03%), and it was the only model to reach a positive Vol (0.05); every baseline stayed strongly negative, from -0.58 down to -37.80, which reveals a systematic failure to recover the ventricular volume trajectory. Even the variant that regresses the frame intensities directly from the same ED volume and phase input incurred more than twice our EF error (30.14%), indicating that the gain came from explicit physiological grounding rather than from the phase conditioning alone.
S. Wang et al.: Preprint submitted to Elsevier
Page 9 of 29
Table 1
Main results on the combined ACDC and M&Ms test set. Best in bold, second-best underlined. Baselines are evaluated with image-based EF (SegUNet on generated frames), whereas PhaseFlow3D uses warped ED masks; EF under unified measurement protocols is cross-validated in Appendix D (Table 4); “—” denotes inapplicable metrics.
| Method | Image & Video Quality | Physiological Fidelity | |||||||
|---|---|---|---|---|---|---|---|---|---|
| PSNR↑ | SSIM↑ | LPIPS↓ | FID↓ | FVD↓ | EF MAE↓ | Vol Corr↑ | Vol ↑ | Vol MAE↓ | |
| ConvLSTM [45] | 19.16 | 0.426 | 0.474 | 292.0 | 23.31 | — | — | -37.80 | 0.734 |
| GAN-cMRI [14] | 22.64 | 0.542 | 0.409 | 185.8 | 19.70 | 39.35% | 0.308 | -32.91 | 0.673 |
| LFDM [26] | 28.50 | 0.800 | 0.200 | 82.53 | 11.24 | 29.83% | -5.547 | 0.221 | |
| CVAE | 33.01 | 0.899 | 0.066 | 27.95 | 4.141 | 32.39% | 0.781 | -0.582 | 0.179 |
| DragNet [7] | 35.61 | 0.928 | 0.030 | 5.450 | 1.690 | 37.77% | 0.757 | -0.484 | |
| SimVP [25] | 0.920 | 0.023 | 6.080 | 1.700 | % | 0.644 | -0.711 | 0.187 | |
| Direct Reg | 30.14% | 0.590 | -0.892 | 0.194 | |||||
| PhaseFlow3D (Ours) | 34.97 | 0.928 | 0.017 | 2.020 | 0.683 | 12.85% | 0.845 | 0.054 | 0.110 |
This advantage carried over to whole-sequence quality. PhaseFlow3D achieved the best FID (2.02) and FVD (0.68), improving video-level coherence over the strongest baseline (1.04) by roughly one third, even though a few methods reached marginally higher per-frame PSNR (36.37 dB against our 34.97 dB). The different PSNR and distributional-quality rankings are consistent with the distinction between distortion and perceptual distribution matching discussed by Blau and Michaeli [46]. The EF and LV volume-curve differences are separate empirical findings of our cardiac experiments, rather than consequences of that theory.
Statistical significance. To confirm that these physiological improvements reflect genuine gains rather than point-estimate artifacts, we applied the paired Wilcoxon signed-rank test on the per-patient physiological metrics (n=166, pairing by patient) against all seven baselines and the trivial static null (ED Repeat). Table 2 reports the resulting p-values; each cell is a p-value rather than a performance score, so a smaller value is stronger evidence in favour of PhaseFlow3D, and in every significant cell the per-patient means favour PhaseFlow3D. PhaseFlow3D was significantly better than every baseline on EF MAE, Vol , and Vol MAE, with p-values ranging from down to . The single non-significant cell was Vol Corr against LFDM (p=0.84): LFDM tracks when the ventricle contracts but, as its negative (-5.55) shows, not by how much, which is precisely the failure mode the volume-curve supervision is designed to correct. Three cells are undefined and omitted: Vol Corr for ED Repeat, whose constant zero-variance volume curve leaves Pearson correlation undefined, and EF MAE/Vol Corr for ConvLSTM, whose generated frames contain no LV cavity for the segmentation network to detect, matching the dashes in Table 1; for GAN-cMRI, EF MAE and Vol Corr are computed over the n=128 patients with a detectable LV cavity.
While Table 1 reports cohort means, Figure 3 shows the full per-patient distribution of every metric across all 166 test subjects. PhaseFlow3D attained the highest median and the tightest spread, confirming that its advantage is consistent rather than driven by a few easy cases.
Table 2
Paired Wilcoxon signed-rank test (n=166 patients) against all baselines. Every cell is a p-value; smaller means stronger evidence that PhaseFlow3D is better, and in every significant cell the per-patient means favour PhaseFlow3D. Bold = significant at α=0.05. The only non-significant cell is Vol Corr vs. LFDM; “—” marks undefined comparisons (constant or empty predicted volume curves).
| Metric | Wilcoxon p (PhaseFlow3D vs.) | |||||||
|---|---|---|---|---|---|---|---|---|
| ED Rep. | ConvLSTM | GAN-cMRI | LFDM | CVAE | DragNet | SimVP | Dir. Reg. | |
| EF MAE | — | |||||||
| Vol Corr | — | — | 0.84 | |||||
| Vol | ||||||||
| Vol MAE | ||||||||
S. Wang et al.: Preprint submitted to Elsevier
Page 10 of 29



Figure 3: Per-patient distribution of image quality (PSNR, SSIM, LPIPS) and physiological fidelity (EF MAE, Vol Corr, Vol ) on the combined ACDC and M&Ms test set (). Each box spans the interquartile range with the median line and 5–95th percentile whiskers. PhaseFlow3D (orange) is compared against the eight baselines (blue); empty slots mark metrics that are undefined for a given method, matching the dashes in Table 1. Vol uses a symmetric-log axis to resolve both the high-performing methods near one and the collapsed baselines.
4.3. Ablation Study
To quantify the contribution of each proposed component, we removed them one at a time and retrained the model under otherwise identical settings. Table 3 reports the outcome: every removal produced a distinct failure mode rather than a uniform degradation, confirming that the components are complementary rather than redundant.
Table 3
Ablation study on the combined ACDC and M&Ms test set. Best in bold, second-best underlined.
| Variant | Image & Video Quality | Physiological Fidelity | |||||||
|---|---|---|---|---|---|---|---|---|---|
| PSNR↑ | SSIM↑ | LPIPS↓ | FID↓ | FVD↓ | EF MAE↓ | Vol Corr↑ | Vol ↑ | Vol MAE↓ | |
| A1: w/o deform decoder | 35.37 | 0.929 | 0.012 | 1.949 | 0.724 | 55.33% | — | -1.766 | 0.250 |
| A2: w/o radial head | 34.48 | 0.924 | 0.017 | 2.155 | 0.765 | 15.00% | 0.851 | -0.244 | 0.114 |
| A3: radial only (w/o residual) | 33.14 | 0.922 | 0.020 | 3.098 | 1.058 | 18.48% | 0.823 | -0.415 | 0.132 |
| A4: w/o vol curve loss | 34.33 | 0.924 | 0.020 | 3.063 | 0.998 | 14.66% | 0.785 | -0.643 | 0.143 |
| A5: linear phase | 34.91 | 0.927 | 0.017 | 1.853 | 0.697 | 12.60% | 0.741 | -0.198 | 0.126 |
| Full model | 34.97 | 0.927 | 0.017 | 2.020 | 0.683 | 12.85% | 0.845 | 0.054 | 0.110 |
S. Wang et al.: Preprint submitted to Elsevier
Page 11 of 29
A1: w/o deformation decoder. Without the deformation pipeline, synthesis falls back to pure VAE decoding, . Per-frame metrics remain nominally strong (PSNR 35.37 dB, LPIPS 0.012), yet EF MAE collapses to 55.33% and Vol Corr becomes undefined: the generated frames contain essentially no ventricular contraction, equivalent to predicting a static ED volume. Image-based evaluation (running SegUNet on the generated frames) likewise yields ~55% EF MAE, confirming that no cardiac motion is produced. The displacement field is thus the sole mechanism through which cardiac motion is encoded, and the prerequisite for applying any physiological loss.
A2: w/o radial head. Leaving all displacement to the data-driven residual degrades EF MAE from 12.85% to 15.00% and inverts Vol from 0.05 to -0.24. The physics-informed prior contributes accuracy that the residual cannot recover on its own: without the radial prior, contraction amplitude and its temporal curve become unreliable.
A3: radial only. Conversely, removing the residual costs image quality: PSNR drops to 33.14 dB and FVD rises to 1.06. A purely radial field cannot represent rotation, twist, or out-of-plane motion. The two components are complementary: the radial part carries the physics, the residual carries everything else.
A4: w/o volume curve loss. Image quality is largely preserved (PSNR 34.33 dB) but EF MAE rises to 14.66% and Vol Corr falls to 0.78: the ES endpoint terms alone anchor two points of the trajectory but cannot constrain its full temporal course. Dense volume-curve supervision is necessary for the complete systolic–diastolic cycle.
A5: linear phase. Replacing the piecewise phase with uniform leaves EF MAE essentially unchanged (12.60% vs. 12.85%) but substantially degrades Vol Corr (0.74 vs. 0.84) and Vol (-0.20 vs. 0.05). The piecewise phase therefore contributes chiefly to volume-curve shape: it lets the conditioning distinguish the rapid systolic descent from the slower diastolic recovery, reproducing the asymmetric trajectory that a uniform encoding cannot.
4.4. Phase Template Validation
The canonical phase template (Sec. 3.2) replaces patient-specific ES timing with a single population-average ES fraction . We quantified the approximation this introduces, using the individual ED and ES timings of the 255 training subjects.
Empirical phase templates. Figure 4 shows the mean piecewise phase templates of each ACDC pathology group and of the pooled M&Ms cohort, together with the uniform linear baseline and the canonical template ( ) used at blind inference. The empirical ES fractions differed systematically across groups: NOR subjects completed systole earliest ( ), followed by HCM ( ) and MINF ( ), whereas ARV ( ) and in particular DCM ( ) exhibited a prolonged systole, consistent with impaired contractility in dilated cardiomyopathy. The pooled M&Ms cohort ( ) and the overall training population ( , n = 255) were both well approximated by the canonical value of 0.38, which lay within a third of a standard deviation of the population mean.
Intra-group consistency. To quantify how well a population-level template approximates individual patient phase curves, we measured the per-frame root mean squared error (RMSE) of each training subject's piecewise phase relative to three candidates: the canonical template used at blind inference; the group-mean template , an oracle that requires the pathology label; and the uniform linear phase . Pooled over all 255 training subjects, the canonical template achieved a mean RMSE of 3.8% of the full cardiac cycle against 6.2% for the linear phase, a 1.6× overall reduction; the largest gains occurred in HCM (2.71% vs. 6.93%, 2.6×) and NOR (3.31% vs. 7.65%, 2.3×), with M&Ms at 3.10% vs. 5.74% (1.9×). The two exceptions were instructive: for ARV the two templates were nearly equivalent (8.21% vs. 8.69%), and for DCM, whose delayed ES timing (0.456) happens to lie close to the linear midpoint, the linear phase was marginally closer (4.93% vs. 5.72%). The group-mean oracle improved only slightly over the canonical template in every group (Figure 5), indicating that a single population-level template captures most of the attainable benefit without requiring any pathology label at inference.
4.5. Deformation Regularity Evaluation
Scaling-and-squaring parameterizes the residual through velocity integration, while the folding penalty discourages negative Jacobian determinants in the total transformation (Sec. 3.7). We evaluate the total field empirically because its additive construction does not guarantee a fold-free transformation. The Jacobian of the coordinate transformation
S. Wang et al.: Preprint submitted to Elsevier
Page 12 of 29

Figure 4: Group-mean piecewise phase templates (coloured; ACDC pathology groups and pooled M&Ms) vs. the canonical template used at inference (black) and the uniform linear baseline (grey dashed). Each template reaches (ES) at the group-mean ES fraction, encoding pathology-specific systole–diastole timing.

Figure 5: Per-frame phase RMSE (% of cycle) of the canonical template (solid blue), the group-mean oracle template (dotted green), and the uniform linear baseline (grey dashed), per ACDC pathology group and for the pooled M&Ms cohort. Shaded region: error saved by the canonical template over the linear baseline.
Id + is a matrix,
which we computed via central finite differences at every voxel of every generated volume on the test set.
Figure 6 shows the empirical distribution of over all 166 test patients (30 frames voxels each, evaluations in total). The fraction of voxels with (folding voxels) was 0.0005% on average and below 0.002% for every individual patient; topology violations were confined to a few isolated voxels per volume and never formed coherent folded regions. The mean determinant was . Determinants below and above unity indicate local contraction and expansion, respectively; these whole-volume statistics do not isolate myocardial tissue or establish tissue incompressibility. Per-group statistics (Figure 6, right) were consistent across the five ACDC pathology groups and the M&Ms cohort ( between 0.990 and 0.992 in every group), supporting similar measured deformation regularity across the evaluated cardiac morphologies and acquisition sites.
S. Wang et al.: Preprint submitted to Elsevier
Page 13 of 29

Figure 6: det(Jφ) distribution of the composed 3D displacement field (radial and scaling-and-squaring residual, K = 7) on the ACDC+M&Ms test set. Left: global histogram (log scale); red dashed: fold boundary (det = 0). Right: per-group mean±std. Folding voxels are 0.0005% on average (< 0.002% per patient), indicating a low measured folding rate.
Figure 7 shows the spatial counterpart for a representative HCM subject: the displacement magnitude stays localized to the myocardium, and falls below one in the contracting wall while remaining strictly positive throughout, so the recovered deformation is both physiologically directed and free of folding.
4.6. Qualitative Results
Figure 8 shows synthesized frames and predicted displacement fields for representative MINF and NOR patients. PhaseFlow3D produced sharp, anatomically coherent frames across the full cardiac cycle, with clearly visible myocardial thickening during systole and chamber expansion during diastole; the VAE-decoded variant exhibited the characteristic blur of VAE reconstruction, particularly at fine anatomical boundaries. The displacement magnitude maps show smooth, anatomically localized deformation concentrated around the myocardium, consistent with the spatial localization enforced by the radial head's dilated mask. Figure 9 maps the per-pixel absolute reconstruction error for three representative subjects across the cardiac cycle. The error stays near zero over the static background and concentrates in a thin band at the myocardial boundary, peaking around ES where motion is largest.
Figure 10 compares predicted and ground-truth LV volume curves. PhaseFlow3D captured the pathology-specific contraction patterns: normal hearts showed the expected 55–70% EF, DCM patients exhibited reduced contraction, and HCM patients showed preserved but hypertrophic dynamics. The piecewise phase conditioning correctly reproduced the asymmetric systole/diastole velocity profile, visible as a steep systolic descent followed by a shallower diastolic recovery. Per-pathology qualitative results across all five ACDC groups are provided in Appendix G.
5. Downstream Applications
The preceding section established that PhaseFlow3D synthesizes sequences that are faithful in image quality and physiology. This section asks whether the synthesized sequences and their displacement fields are useful. We evaluate four applications: substituting synthetic supervision for real supervision in segmentation and in pathology classification, propagating segmentation labels through the recovered displacement field, and deriving myocardial strain from the generated motion. A fifth, auxiliary experiment measures perceptual realism with a learned discriminator. In all experiments the generator is frozen and inference is blind: a single real ED volume and the canonical phase template, with no ES image, ECG, or pathology label. Unless stated otherwise, results are reported as mean ± standard deviation over three random seeds, which reflects seed variability rather than a confidence interval. Protocol details and full per-fraction tables are given in Appendix H.
S. Wang et al.: Preprint submitted to Elsevier
Page 14 of 29

Figure 7: Spatial view of deformation regularity for a representative HCM subject (patient036, mid-ventricular slice) at six frames across the cardiac cycle. Rows: ground-truth cine, PhaseFlow3D generation, displacement magnitude , and Jacobian determinant . The deformation is localized to the myocardium; (blue) marks local contraction and > 1 (red) local expansion, and it stays strictly positive everywhere, confirming a fold-free diffeomorphic mapping.
5.1. Synthetic Supervision for Segmentation
We first test whether a synthesized training sample can stand in for a real one. With the training budget fixed, an increasing fraction of the real supervision for a 2D segmentation U-Net (LV and myocardium) is replaced by synthetic supervision, and the network is always evaluated on the real ACDC test ED and ES frames. Pipeline A performs phase-aligned substitution: a patient's real ES image and annotation are replaced by the synthesized ES frame and the ED mask warped to ES. Pipeline B substitutes real ED and ES slices with synthesized intermediate-phase slices carrying pseudo-labels at a fixed total slice budget.
Figure 11 shows the resulting Dice over the substitution fraction. Under pipeline A, Dice moves from with all-real supervision to with fully synthetic supervision, a retention of 99.2%, and up to 75% substitution the curve stays within the seed-noise band of the all-real baseline. Pipeline B retains 96.9% under full substitution, with a mild decline appearing only beyond 75%. These results indicate that a synthesized ES supervision unit is nearly interchangeable with a real one.
5.2. Synthetic Supervision for Pathology Classification
The same substitution protocol is applied to five-class pathology classification on ACDC. A random forest [47] receives five geometric features in physical units (LV volume, myocardial mass, mean wall thickness, LV sphericity, and the mass-to-volume ratio) computed from segmentation masks of the 45 generator-unseen ACDC patients. Real training samples use the real ED and ES masks; synthetic training samples use the ED mask warped to intermediate synthesized phases. Evaluation always uses real features, with patient-stratified five-fold cross-validation.
Figure 12 shows the degradation curve. Balanced accuracy is with all-real training and when a quarter of the training samples are synthetic, a drop of about two points. Under full substitution it falls to , a retention of 72.7% that remains more than the chance level of 0.2. Synthetic geometry therefore carries most, though not all, of the class-discriminative signal, and moderate substitution is nearly free.
S. Wang et al.: Preprint submitted to Elsevier
Page 15 of 29
MINF
NOR

Figure 8: Qualitative comparison (MINF and NOR, mid-ventricular slice). Rows 1–3: ground truth, the VAE-decoded variant (A1), and PhaseFlow3D at ED, mid-systole, ES, and mid-diastole. Row 4: predicted displacement magnitude . PhaseFlow3D produces sharp, anatomically coherent frames; the VAE-decoded variant exhibits characteristic reconstruction blur.

Figure 9: Per-pixel absolute reconstruction error |Gen – GT| for three representative subjects (rows) across six frames spanning the cardiac cycle (columns), on the mid-ventricular slice. The error stays near zero over the static background and concentrates in a thin band at the myocardial boundary, peaking around ES where motion is largest.
5.3. Label Propagation Through the Displacement Field
The displacement field itself can transfer annotations. We warp each ACDC test patient’s real ED annotation to ES through the recovered displacement field and score it against the real ES annotation. Two references bound the task: a no-motion floor that reuses the ED mask as the ES prediction, and classical Demons registration [48], an oracle upper bound because it registers the real ED image to the real ES image, which our blind setting never observes.
S. Wang et al.: Preprint submitted to Elsevier
Page 16 of 29

LV Volume Curves by Pathology
Figure 10: LV volume curves (% of ED volume). Ground-truth (solid) vs. PhaseFlow3D-predicted (dashed) trajectories for one representative patient per ACDC pathology group.

Figure 11: Segmentation substitution. Test Dice (LV and myocardium mean, 3-seed mean) vs. the fraction of real supervision replaced by synthetic supervision, for phase-aligned substitution (pipeline A, blue) and full-cycle substitution (pipeline B, red). Dashed lines: each pipeline's all-real baseline. Right edge: retention, the ratio of fully synthetic to all-real Dice.
Figure 13 reports LV Dice on the 30 test patients. Our propagation reaches , recovering most of the interval between the floor and the two-frame oracle while using no ES information. In the NOR and ARV groups the blind propagation even exceeds the oracle. Myocardium Dice is lower (0.572 vs. 0.700 for Demons; Table 9), as expected for a thin structure under an LV-centric prior.
5.4. Myocardial Strain Analysis
Motion analysis is a core promised use of the recovered displacement field. We compute global circumferential strain (GCS) at peak systole, identified as the synthesized frame of minimum warped LV volume, from the Green–Lagrange strain tensor of the displacement field averaged over the warped myocardium (Appendix H). The analysis covers all 166 combined test patients and remains fully blind, so any group structure must arise from the single ED volume alone.
Figure 14 shows the per-patient GCS. The ACDC groups separate according to expected contractile function: NOR shows the strongest contraction , MINF and ARV are intermediate and , HCM is reduced , and DCM is weakest ; a Kruskal–Wallis test across the five groups gives , . The pooled M&Ms cohort falls between NOR and the diseased groups, consistent with its mixed composition. Strain magnitudes are smaller than clinically reported values, in line with the residual under-contraction quantified by the EF analysis in Sec. 4, so we interpret this experiment as validating group separation and ordering rather than absolute strain values.
S. Wang et al.: Preprint submitted to Elsevier
Page 17 of 29

Figure 12: Classification substitution. Balanced accuracy and macro-F1 (3-seed mean ± std) vs. the fraction of real geometry samples replaced by synthetic ones. Dashed line: all-real balanced accuracy; dotted line: 5-class chance. Right edge: balanced-accuracy retention.

Figure 13: Label propagation. LV Dice of the ED annotation warped to ES, per ACDC pathology group and pooled (All), for the no-motion floor, our blind single-frame propagation, and the Demons two-frame oracle that sees the real ES image. Bars: patient mean; error bars: patient std.
5.5. Perceptual Realism
As an auxiliary check, we train a small convolutional neural network (CNN) discriminator to separate real cine slices from synthesized ones, where an area under the receiver operating characteristic (ROC) curve (AUC) near 0.5 means the two are hard to distinguish. The discriminator sees intermediate-phase slices of the 45 generator-unseen ACDC patients (1350 slices per arm) under patient-level five-fold cross-validation; no tuning is performed in either direction.
The discriminator attains an AUC of (Figure 15), leaving only mild residual separability above the chance level of 0.5. Per-phase AUC peaks in the mid-systolic third (0.718) and falls to 0.574 late in the cycle, consistent with the mild under-contraction around ES noted above being the main residual cue. Because real frames pass through the same temporal resampling as the synthesis grid, any residual preprocessing difference can only assist the discriminator, so this AUC is a conservative upper bound on the separability attributable to synthesis.
S. Wang et al.: Preprint submitted to Elsevier
Page 18 of 29

Figure 14: Peak-systolic GCS from the synthesized motion, by ACDC pathology group (blue) and for the pooled M&Ms cohort (grey). Bars: group mean; error bars: patient standard deviation. The Kruskal–Wallis test is computed across the five ACDC groups.

Figure 15: Perceptual realism. Left: pooled out-of-fold ROC of the real-vs-synthetic discriminator (3-seed mean, shaded band: seed std); the dotted diagonal is chance. Right: AUC by cycle third; mid-systole carries most of the residual separability.
6. Discussion
Physiological fidelity and design priors. In our comparisons, SimVP and Direct Reg reach higher PSNR yet have larger EF errors and lower volume-curve than PhaseFlow3D. This is an empirical finding about physiological accuracy. The perception–distortion trade-off [46] concerns image distortion and distributional quality, and does not by itself predict errors in cardiac function. The metric families answer different questions: PSNR measures how closely a specific ground-truth sequence is reproduced, FID and FVD measure whether the generated distribution matches the real one, and EF and volume metrics measure whether the synthesized heart beats correctly. That PhaseFlow3D more than halves the EF error of the strongest baseline while conceding only a modest amount of PSNR indicates that task-specific physiological metrics, rather than pixel accuracy, should drive the evaluation of cardiac synthesis. This physiological fidelity follows from our design priors. The Radial Contraction Decomposition is the component whose removal costs the most physiological accuracy (A2), whereas the residual is the component whose removal costs the most image quality (A3), so the decomposition cleanly separates the two responsibilities. Beyond accuracy, the radial head offers two practical benefits. Its global amplitude is a directly interpretable, patient-specific readout of contraction magnitude, shaped by the EF loss during training. Because the radial direction field is computed analytically from the LV centroid, the prior also transfers across patients and scanner vendors without any additional learning. A
S. Wang et al.: Preprint submitted to Elsevier
Page 19 of 29 second prior, the piecewise cardiac phase, governs how the model is conditioned at inference. Its canonical template makes inference fully blind: a single 3D ED volume suffices, with no ECG, gating, pathology label, or segmentation inference at deployment. Ablation A5 confirms that this asymmetric parameterization is what preserves the volume-curve shape, which a uniform phase fails to recover despite matching comparable EF accuracy. The population-level template closely approximates individual ES timing (Sec. 4.4), suggesting that the temporal approximation is useful for the synthesis task on the evaluated cohorts; clinical utility requires separate validation.
Utility and applications. Because inference requires only a single ED volume and no ECG, and because every synthesized frame is accompanied by an explicit displacement field, PhaseFlow3D is useful beyond visualization, and Sec. 5 quantifies this utility directly. The recovered displacement field supports quantitative cardiac motion analysis over the full cycle, recovering the expected ordering of contractile function across pathology groups from a single ED volume, and the synthesis of a complete sequence from one frame offers a route to recovering missing frames when only an isolated reference volume survives in retrospective archives. Synthesized sequences can also substitute for real supervision in downstream segmentation and disease classification, where paired cine data are scarce, with near-lossless retention for phase-aligned segmentation supervision and moderate cost for classification. Finally, since each synthetic sequence carries a known ground-truth deformation field, the generated data can serve as a benchmark for validating deformable registration algorithms and for in-silico trials that require a moving cardiac model with known motion.
Limitations. The EF MAE remains 12.85 percentage points, indicating substantial residual error in patient-specific functional prediction. Published inter-modality agreement limits [1] are not directly comparable with this MAE and do not establish clinical equivalence. Dedicated reproducibility studies and validation on larger, more diverse cine CMR cohorts remain necessary. A single ED volume and a canonical phase also cannot uniquely determine a patient's true contraction trajectory; generated dynamics remain model-based predictions rather than observed measurements. All experiments use ECG-gated cine acquisitions resampled to D = 16 slices; very thick or thin slabs may require adapting the depth compression, and extension to free-breathing acquisitions or to anchor frames other than ED remains future work. Finally, pathologies with pronounced non-radial motion, such as severe apical rotation in HCM, stress the residual pathway and warrant dedicated study.
7. Conclusion
In this paper, we developed PhaseFlow3D, a generative framework for synthesizing 4D cine CMR sequences from a single ED volume without any ECG dependency. The model is generative and can efficiently produce physiologically faithful cardiac motion for a large number of subjects. Compared with conventional cine synthesis and registration techniques, the proposed model generates more physiologically accurate ventricular dynamics while requiring only a single 3D volume at inference. In terms of physiological fidelity, it attains the best EF accuracy and the most faithful LV volume-curve reconstruction among all compared methods. Besides, the proposed framework synthesises high temporal resolution cardiac motion sequences together with their underlying displacement fields, which can be applicable for cardiac motion analysis, for recovering missing frames when only a single reference volume survives, for data augmentation in downstream segmentation and disease classification, and for validating deformable registration algorithms and enabling in-silico trials where a synthetic sequence with a known deformation field is required. Our future work will focus on extending this model to free-breathing acquisitions and to anchor frames other than ED. Besides, we will validate the framework on larger and more diverse cine CMR cohorts toward clinical deployment.
A. Excluded Baselines
We detail why three otherwise-natural families of baselines were excluded from the main comparison.
Registration methods. Registration-based methods such as VoxelMorph [3] address a different task: aligning two observed images. In that formulation, a target frame is required at inference and is unavailable in our single-ED-volume setting.
ECG-conditioned methods. ECG-conditioned approaches [8, 9] require an ECG input at inference, which violates our ECG-free setting and would make a direct comparison unfair in either direction.
S. Wang et al.: Preprint submitted to Elsevier
Page 20 of 29
EchoLVFM. EchoLVFM [24] has a publicly available implementation and uses MeanFlow-based generation conditioned on observed echocardiographic frames and a target EF. A direct comparison would require adaptation from 2D ultrasound to 3D-volume CMR sequences and a harmonized conditioning protocol: providing a target EF would add information unavailable to PhaseFlow3D at inference, while removing it would change EchoLVFM's reported setup.
B. Implementation Details
CineVAE3D. A true 3D VAE with per-frame encoding: input per frame, latent . The encoder downsamples over four levels: the first two halve depth and in-plane resolution together, whereas the third halves only the in-plane resolution, with 3D spatial attention applied at the two coarsest levels. The temporal dimension is handled externally by per-frame encoding; the flow model performs all temporal reasoning. Pretrained for 100 epochs (lr = , KL weight , 4 frames sampled per volume per step), then frozen.
VelocityUNet4D. D'-fold trick: input before each level, unfolded back after. 3D U-Net backbone: base channels 128, multipliers , two residual blocks per level. AdaGN: the flow time is encoded via a sinusoidal embedding and MLP, added to the temporal-mean phase embedding as the global condition. Phase cross-attention: , , per frame, at both levels. The output convolution is zero-initialized.
ImageEncoder3D. A lightweight 3D CNN (3 levels, channels [16, 32, 64]) processing ; its multi-scale feature maps are injected as skip connections into the deformation decoder at matching resolutions.
ImageConditionedDeformDecoder3D. 3D transposed convolutions (three upsampling steps) from (4, 4, 16, 16) to (3, 16, 128, 128), with ImageEncoder3D skip features concatenated after each step and a learnable output scale initialized to 10.0.
RadialContractionHead. GlobalNet: GAP(f) → Linear(64) → SiLU → Linear(1) → σ → . LocalNet: a small 3D convolutional upsampler (a convolution, two transposed-convolution upsampling stages, and a final convolution with sigmoid), mean-normalized within the dilated LV ROI so that it only modulates the spatial distribution of contraction. TemporalNet: Linear( ) → SiLU → Linear(64, 1) per frame, peak-normalized with ED subtraction.
SpatialTransformer3D. Differentiable 3D warping via trilinear grid sampling with border padding; the ED volume is broadcast to T frames and each per-frame displacement is applied independently.
Training details. Stage 1: 50 epochs, physiology-only losses. Stage 2: 100 epochs, all losses, checkpoint selected by validation EF MAE. Both stages: AdamW ( , , weight decay ), cosine annealing from lr = to , batch size 1, AMP mixed precision. for construction; scaling-and-squaring steps.
C. Data Preprocessing
We describe the full preprocessing pipeline applied to the ACDC and M&Ms cine CMR studies. One offline stage fixes the patient-level splits; a per-sample transform is then applied on the fly inside the Dataset. Algorithm 1 gives the exact sequence of operations.
No intensity augmentation, cropping, or registration is applied; the only spatial operations are an isotropic in-plane resize and a center depth pad/crop. Intensity normalization is performed per patient so that all frames share one intensity range, preserving relative temporal contrast. The stratified ACDC split and the M&Ms subset partitions are reused unchanged across all models (main and baselines) to ensure an identical evaluation protocol.
D. Evaluation Metrics
We formally define the metrics used in the main paper and state the motivation for each. Let and denote the generated and ground-truth frame at time ( ), with voxel intensities rescaled to .
S. Wang et al.: Preprint submitted to Elsevier
Page 21 of 29
Algorithm 1 Preprocessing (per patient; 3D volume sequence)
1: Offline (once): ACDC: collect all 150 patients, read pathology Group from each Info.cfg, stratified split by group into train/val/test = 105/15/30 with seed 42 → split.json. M&Ms: retain the challenge split assignments for the included cases (Labeled Training/Validation/Testing = 150/34/136).
2: Per sample (one patient):
3: Load 4D NIfTI (H, W, Z, ); read ED/ES frame indices (ACDC: Info.cfg; M&Ms: challenge metadata).
4: M&Ms only: circularly shift the time axis so that ED becomes frame 0 (ACDC sequences already start at ED); remap segmentation labels to the ACDC convention.
5: Reorder to ( , 1, Z, H, W).
6: Spatial: bilinear resize each slice to .
7: Depth: center pad (zeros) or center crop .
8: Temporal: linear resample frames; rescale the ES index accordingly.
9: Intensity: per-patient min-max normalize the resampled sequence to (a single range shared by all frames of the sequence).
10: Phase: piecewise linear (ED = 0 → ES = → last frame = ) from the ED/ES indices, resampled to T; encode as .
11: Masks: binary LV cavity masks at ED and ES (label 3), nearest-neighbor resized and depth-padded/cropped identically to the image volume.
12: return (cine, , , es_idx, , ).
Image and video quality.
- PSNR (dB), averaged over frames: PSNR = 10 log₁₀(1/MSE( , )). Motivation: standard pixel-level fidelity measure; penalizes reconstruction error directly.
• SSIM [41]: SSIM = . Motivation: captures structural/luminance/contrast agreement, correlating better with perceived quality than PSNR for anatomical structure.
• LPIPS [42]: distance between deep features of and . Motivation: perceptual similarity that is sensitive to texture realism, which pixel metrics miss.
• FID [43]: over Inception features of real and generated frames. Motivation: measures distributional realism of the generated frames as a set, complementing per-frame metrics.
• FVD [44]: the same Fréchet distance computed over I3D video features of complete sequences. Motivation: sensitive to temporal coherence and motion statistics that frame-level metrics cannot capture.
Physiological fidelity. Let and be the ground-truth and predicted LV cavity volume at frame . Under the primary protocol reported in Table 1, for PhaseFlow3D is obtained by warping the ED segmentation mask through the predicted displacement field, so the segmentation network is never applied to generated frames; for every baseline, is obtained by segmenting the generated frames with the same frozen SegUNet.
• EF MAE (%): absolute error of ejection fraction EF = . Motivation: EF is the primary clinical index of cardiac function; a direct measure of physiological correctness.
• Vol Corr: Pearson correlation between and . Motivation: tests whether the shape of the volume–time trajectory is reproduced, independent of scale.
• Vol : coefficient of determination . Motivation: penalizes both bias and variance of the volume curve; negative values expose predictions worse than the mean.
• Vol MAE: mean absolute per-frame volume error, normalized by ED volume. Motivation: a scale-aware complement to the correlation-based measures.
S. Wang et al.: Preprint submitted to Elsevier
Page 22 of 29
Cross-protocol validation of EF. The primary protocol measures PhaseFlow3D and the baselines through different pathways, whose error sources differ. To verify that this asymmetry does not drive the ranking in Table 1, we recomputed the EF MAE on the same 166 test patients under two unified protocols (Table 4). Under the image-based protocol, the generated frames of every method, including ours, are segmented by the same frozen SegUNet, and the reference EF is derived from the expert annotations. Both unified protocols take the annotations as the reference, which keeps the reference independent of the segmentation network that enters the predicted volumes. In Table 1, the baseline EF is instead referenced against the SegUNet volume curve measured on the real frames, because the per-frame volume metrics require a reference at every frame whereas the annotations exist only at ED and ES; this accounts for the small offsets between the two tables. Under the mask-propagation protocol, the ED annotation is warped through each method's own displacement field, following exactly the transformation that produced its frames. The latter protocol is defined only for methods that expose a displacement field in image space; among the baselines, only DragNet does, through its autoregressive spatial-transformer warps. Direct Reg regresses voxel intensities and exposes no displacement field. LFDM displaces only its latent grid and reaches image space through a learned decoder, so no pixel-space field exists to propagate. The remaining baselines synthesize intensities without an explicit motion representation.
Table 4 EF MAE (% , patient mean ± std, n=166) under the two unified measurement protocols, both referenced against the expert annotations. “—”: the method exposes no pixel-space displacement field, so mask propagation is undefined. ConvLSTM is omitted because its EF is undefined under either protocol (cf. Table 1). For GAN-cMRI, 38 cases whose generated frames yield an empty LV cavity are excluded (n=128).
| Method | Image-based | Mask propagation |
|---|---|---|
| GAN-cMRI [14] | 38.68 ± 18.07 | — |
| LFDM [26] | 29.67 ± 15.76 | — |
| CVAE | 31.70 ± 18.55 | — |
| DragNet [7] | 36.49 ± 16.43 | 37.73 ± 16.80 |
| SimVP [25] | 26.22 ± 18.08 | — |
| Direct Reg | 29.71 ± 17.66 | — |
| PhaseFlow3D (Ours) | 14.55 ± 12.53 | 12.85 ± 11.03 |
Three observations follow. First, under the unified image-based protocol PhaseFlow3D attains an EF MAE of 14.55% against 26.22% for the best baseline, so the advantage in Table 1 is not an artefact of the measurement pathway. Second, for DragNet, the one baseline that admits both protocols, the two pathways closely agree (37.73% versus 36.49%), confirming that its EF error reflects under-estimated motion rather than segmentation error on generated frames. Third, applied to real frames and compared against the expert annotations, the segmentation network alone incurs an EF MAE of 5.48% ± 5.33%, which bounds the measurement noise shared by all image-based entries and lies well below every inter-method gap. For completeness, referencing the segmenter's volumes on real frames instead of the annotations changes the image-based EF MAE of PhaseFlow3D from 14.55% to 14.34%.
E. Metric Variability
All reported numbers are obtained from a single training run under fixed seed 42; to characterize the distribution of performance beyond point estimates, Table 5 reports both the per-patient mean ± standard deviation and the median with interquartile range (IQR) of PhaseFlow3D over the joint ACDC+M&Ms test set (n=166 patients). Image-quality metrics are tightly concentrated (e.g. SSIM 0.927 ± 0.012). The physiological metrics are more dispersed and heavy-tailed: because Vol is unbounded below, a small number of outlier patients pull its mean toward zero and inflate its standard deviation, so the median and IQR (Vol median 0.567, IQR [-0.058, 0.797]) give a more representative summary. This spread reflects genuine between-patient variation in cardiac motion and pathology severity rather than estimator noise.
S. Wang et al.: Preprint submitted to Elsevier
Page 23 of 29
Table 5 Per-patient dispersion of PhaseFlow3D on the joint ACDC+M&Ms test set ( patients), reported as mean standard deviation and as median with interquartile range.
| Metric | Mean Std | Median [IQR] |
|---|---|---|
| Image quality | ||
| PSNR (dB) | ||
| SSIM | ||
| LPIPS | ||
| Physiological fidelity | ||
| EF MAE (%) | ||
| Vol Corr | ||
| Vol | ||
| Vol MAE | ||
F. Latent Scale and Anchor Perturbation
The anchor noise scale in the anchor latent construction (with ) is only meaningful relative to the scale of the latent space itself. We therefore measure the empirical statistics of the frozen CineVAE3D latents over the ACDC+M&Ms training and validation splits (Table 6). Latents are taken as the posterior mode , matching the training configuration; the full sequence latent has dimension .
Table 6 Empirical latent statistics ( = per-element standard deviation, averaged over patients). The two splits agree closely, indicating the latent scale is a stable property of the frozen encoder rather than a split artifact.
| Quantity | Train () | Val () |
|---|---|---|
| of | 0.800 | 0.794 |
| of anchor | 0.798 | 0.793 |
| of | 0.131 | 0.122 |
| 12.5% | 12.6% | |
| 76.6% | 82.1% |
Geometry of the perturbation. At the vector level the anchor noise is not small relative to the motion signal. On the validation split the transport distance is , the noise norm is (matching the theoretical ), and the perturbed and clean transport directions differ by . Two observations explain why a perturbation of this magnitude is nevertheless benign. First, the component of the noise along the motion direction is negligible. Its projection onto is , i.e. of the transport distance, matching the prediction that for isotropic this projection follows independently of ). The noise therefore introduces no appreciable bias in the transport length along the motion direction. Second, the large orthogonal component changes the start point but not the supervision target. The perturbed anchor is itself the input to the velocity network, and the endpoint is held fixed, so each noise draw defines a valid training pair from a different start point to the same target. The noise thus acts as an augmentation of the anchor rather than as unobservable corruption: the network is trained to transport the entire cone of perturbed anchors to the same , and at inference it observes the noisy anchor it must compensate for. On this basis is a safe choice. The training split gives consistent values , projection , angle ).
G. Extended Qualitative Results
Figure 16 presents representative generated cine sequences for one patient from each ACDC pathology group (mid-ventricular slice). Each group occupies two rows: the top row shows the ground-truth sequence and the bottom
S. Wang et al.: Preprint submitted to Elsevier
Page 24 of 29 row shows the PhaseFlow3D synthesis, at six evenly-spaced frames spanning the full cardiac cycle. The leftmost frame (ED, ) is the only input to the model at inference time; all subsequent frames are synthesized from the canonical phase template and the predicted 3D displacement field.
PhaseFlow3D faithfully captures the characteristic motion signatures of each pathology: normal wall-thickening in NOR, large-cavity contraction in DCM, asymmetric septal hypertrophy in HCM, regional wall-motion abnormality in MINF, and preserved right ventricular dynamics in ARV.
H. Downstream Experiment Protocols and Full Results
This appendix records the protocols and complete per-fraction results of the downstream experiments in Sec. 5. All experiments use the frozen main checkpoint under blind canonical-phase inference. Substitution experiments use seeds and report the seed mean standard deviation.
Segmentation substitution (Sec. 5.1). The segmentation network is a 2D U-Net trained for 40 epochs per configuration on ACDC training patients, with classes LV and myocardium and the RV mapped to an ignore label in synthetic pseudo-labels. In pipeline A the substitution unit is a patient's ES supervision pair (image and annotation), replaced by the synthesized ES frame and the real ED annotation warped to ES. In pipeline B the real pool holds ED and ES slices while the synthetic pool holds eight intermediate synthesized phases per patient with warped pseudo-labels, and substitution proceeds at a fixed total slice budget. Evaluation uses the real ACDC test ED and ES frames in every configuration. Table 7 lists the full curves.
Table 7
Segmentation substitution: test Dice (LV and myocardium mean, 3-seed mean std) at each synthetic supervision fraction.
| Synthetic fraction | Pipeline A | Pipeline B |
|---|---|---|
| 0% | ||
| 25% | ||
| 50% | ||
| 75% | ||
| 90% | ||
| 100% | ||
| Retention | 99.2% | 96.9% |
Classification substitution (Sec. 5.2). The classifier is a random forest with 400 trees under patient-stratified five-fold cross-validation; a patient's samples never cross folds, and test folds always use features from the real ED and ES annotations, aggregated per patient by the mean predicted probability. Real training samples contribute two feature vectors per patient (ED and ES); synthetic samples contribute eight, one per intermediate synthesized phase, computed from the warped ED annotation. All five features are computed in physical units from the voxel spacing. Table 8 lists the full curves.
Table 8
Classification substitution: five-class balanced accuracy and macro-F1 (3-seed mean std) at each synthetic substitution fraction.
| Synthetic fraction | Balanced accuracy | Macro-F1 |
|---|---|---|
| 0% | ||
| 25% | ||
| 50% | ||
| 75% | ||
| 90% | ||
| 100% |
S. Wang et al.: Preprint submitted to Elsevier
Page 25 of 29
Label propagation (Sec. 5.3). The experiment is deterministic (no training, no seeds). Our arm warps the multiclass ED annotation through the recovered displacement field to the canonical ES frame with nearest-neighbour interpolation. The Demons oracle runs fast symmetric-forces Demons registration [48] for 50 iterations from the real ED image to the real ES image after histogram matching, then applies the resulting field to the ED annotation. Table 9 reports both structures.
Table 9
Label propagation on the ACDC test set (n=30): Dice of the ED annotation warped to ES (patient mean std) per structure and arm.
| Structure | No-motion floor | Ours (single-frame) | Demons (oracle) |
|---|---|---|---|
| LV | |||
| Myocardium |
Strain analysis (Sec. 5.4). For each patient, the peak-systolic frame is the synthesized frame of minimum warped LV volume. Because the network predicts the backward sampling map (Eq. (11)), the identity plus the spatial gradient of the displacement at is the inverse deformation gradient, evaluated at frame- coordinates. This matrix is inverted at each voxel to obtain the forward deformation gradient, from which the Green–Lagrange strain tensor is computed. The tensor is projected per slice onto the circumferential direction defined relative to the LV centroid, and GCS is the robust mean over the warped myocardium with strain magnitudes above 1 excluded as numerical outliers. Radial and longitudinal projections are computed but not reported, for the reasons given in Sec. 5.4.
Realism discriminator (Sec. 5.5). The discriminator is a four-block strided CNN trained for eight epochs with learning rate and batch size 64 on slices. Per patient and arm, six intermediate-phase frames (excluding ED) and five LV-containing slices enter the pools, giving 1350 slices per arm over the 45 patients. Folds are split at the patient level, so a patient's real and synthetic slices share a fold, and the reported AUC is computed on pooled out-of-fold predictions.
S. Wang et al.: Preprint submitted to Elsevier
Page 26 of 29

Figure 16: Per-pathology qualitative results (one representative patient per group). Top row: ground truth; bottom row: PhaseFlow3D synthesis. ED frame (t = 0, leftmost) is the sole model input.
S. Wang et al.: Preprint submitted to Elsevier
Page 27 of 29
CRediT authorship contribution statement
Shiyi Wang: Conceptualization, Methodology, Software, Validation, Writing - Original draft. Ruochen Sun: Data Curation. Xiang Li: Formal analysis. Peirong Liu: Writing - Review & Editing. Fangxu Xing: Supervision.
References
[1] N. G. Bellenger, M. I. Burgess, S. G. Ray, A. Lahiri, A. J. S. Coats, J. G. F. Cleland, D. J. Pennell, Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance. Are they interchangeable?, European Heart Journal 21 (2000) 1387–1396.
[2] F. Grothues, G. C. Smith, J. C. C. Moon, N. G. Bellenger, P. Collins, H. U. Klein, D. J. Pennell, Comparison of interstudy reproducibility of cardiovascular magnetic resonance with two-dimensional echocardiography in normal subjects and in patients with heart failure or left ventricular hypertrophy, The American Journal of Cardiology 90 (2002) 29–34.
[3] G. Balakrishnan, A. Zhao, M. R. Sabuncu, J. Guttag, A. V. Dalca, VoxelMorph: A learning framework for deformable medical image registration, IEEE Transactions on Medical Imaging 38 (2019) 1788–1800.
[4] J. Krebs, T. Mansi, N. Ayache, H. Delingette, Probabilistic motion modeling from medical image sequences: Application to cardiac cine-MRI, in: Statistical Atlases and Computational Models of the Heart (STACOM), MICCAI Workshop, Springer, 2019.
[5] J. Yang, Y. Lin, B. Pu, X. Li, Bidirectional recurrence for cardiac motion tracking with Gaussian process latent coding, in: Advances in Neural Information Processing Systems, volume 37, 2024.
[6] R. Jena, D. Sethi, P. Chaudhari, J. C. Gee, Deep learning in medical image registration: Magic or mirage?, in: Advances in Neural Information Processing Systems, volume 37, 2024.
[7] A. Zakeri, A. Hokmabadi, N. Bi, I. Wijesinghe, M. G. Nix, S. E. Petersen, A. F. Frangi, Z. A. Taylor, A. Gooya, DragNet: Learning-based deformable registration for realistic cardiac MR sequence generation from a single frame, Medical Image Analysis 83 (2023) 102678.
[8] Y. Li, S. Kim, Z. Wu, H. Jiang, Y. Pan, P. Jin, S. Song, Y. Shi, T. Liu, Q. Li, X. Li, ECHOPulse: ECG controlled echocardiograms video generation, in: International Conference on Learning Representations, 2025.
[9] X. Fang, Z. Ding, G. Nie, J. Cai, Y. Xiao, B. Liu, J. Jin, H. Wang, S. Huang, T. Chen, et al., ECGFlowCMR: Pretraining with ECG-generated cine CMR helps cardiac disease classification and phenotype prediction, arXiv preprint arXiv:2601.20904 (2026).
[10] I. Goodfellow, J. Pouget-Abadie, M. Mirza, B. Xu, D. Warde-Farley, S. Ozair, A. Courville, Y. Bengio, Generative adversarial nets, in: Advances in Neural Information Processing Systems, volume 27, 2014.
[11] J. Ho, A. Jain, P. Abbeel, Denoising diffusion probabilistic models, in: Advances in Neural Information Processing Systems, volume 33, 2020, pp. 6840–6851.
[12] Y. Song, J. Sohl-Dickstein, D. P. Kingma, A. Kumar, S. Ermon, B. Poole, Score-based generative modeling through stochastic differential equations, in: International Conference on Learning Representations, 2021.
[13] N. Algethami, T. Iqbal, I. Ullah, Generative AI for biomedical video synthesis: A review, Artificial Intelligence Review 58 (2025) 392.
[14] M. Vukadinovic, A. C. Kwan, D. Li, D. Ouyang, GANcMRI: Cardiac magnetic resonance video generation and physiologic guidance using latent space prompting, in: Machine Learning for Health (ML4H), volume 225 of Proceedings of Machine Learning Research, PMLR, 2023, pp. 594–606. URL: https://proceedings.mlr.press/v225/vukadinovic23a.html.
[15] X. Zhou, Y. Huang, W. Xue, H. Dou, J. Cheng, H. Zhou, D. Ni, HeartBeat: Towards controllable echocardiography video synthesis with multimodal conditions-guided diffusion models, in: Medical Image Computing and Computer-Assisted Intervention (MICCAI), volume 15007 of Lecture Notes in Computer Science, Springer Nature Switzerland, 2024, pp. 361–371. doi:10.1007/978-3-031-72104-5_35.
[16] N. V. Phi, T. M. Duc, P. H. Hieu, T. Q. Long, Echocardiography video synthesis from end diastolic semantic map via diffusion model, in: IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), 2024.
[17] M. Zhao, H. Zhu, C. Xiang, K. Zheng, C. Li, J. Zhu, Identifying and solving conditional image leakage in image-to-video diffusion model, in: Advances in Neural Information Processing Systems, volume 37, 2024.
[18] H. Fukuta, W. C. Little, The cardiac cycle and the physiologic basis of left ventricular contraction, ejection, relaxation, and filling, Heart Failure Clinics 4 (2008) 1–11.
[19] X. Liu, C. Gong, Q. Liu, Flow straight and fast: Learning to generate and transfer data with rectified flow, in: International Conference on Learning Representations, 2023.
[20] D. P. Kingma, M. Welling, Auto-encoding variational Bayes, in: International Conference on Learning Representations, 2014.
[21] M. Seyfarth, S. K. Müller, A. Ghanaat, I. Ayx, F. Fastenrath, P. Wild, A. Hertel, T. Papavassiliu, S. U. H. Dar, S. Engelhardt, CardioDiT: Latent diffusion transformers for 4D cardiac MRI synthesis, in: Medical Image Computing and Computer-Assisted Intervention (MICCAI), volume 16890 of Lecture Notes in Computer Science, Springer, 2026.
[22] Y. Lipman, R. T. Q. Chen, H. Ben-Hamu, M. Nickel, M. Le, Flow matching for generative modeling, in: International Conference on Learning Representations, 2023.
[23] Z. Zhang, Y. Li, Y. Wu, Y. Xu, A. Kag, I. Skorokhodov, W. Menapace, A. Siarohin, J. Cao, D. Metaxas, S. Tulyakov, J. Ren, SF-V: Single forward video generation model, in: Advances in Neural Information Processing Systems, volume 37, 2024.
[24] E. Oladokun, S. Thomas, J. Šprem, V. Grau, EchoLVFM: One-step video generation via latent flow matching for echocardiogram synthesis, arXiv preprint arXiv:2603.13967 (2026).
[25] Z. Gao, C. Tan, L. Wu, S. Z. Li, SimVP: Simpler yet better video prediction, in: IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 2022, pp. 3170–3180.
[26] H. Ni, C. Shi, K. Li, S. X. Huang, M. R. Min, Conditional image-to-video generation with latent flow diffusion models, in: IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 2023, pp. 18444–18455.
S. Wang et al.: Preprint submitted to Elsevier
Page 28 of 29
[27] V. Arsigny, O. Commowick, X. Pennec, N. Ayache, A log-Euclidean framework for statistics on diffeomorphisms, in: International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI), Springer, 2006, pp. 924–931.
[28] A. V. Dalca, G. Balakrishnan, J. Guttag, M. R. Sabuncu, Unsupervised learning for fast probabilistic diffeomorphic registration, in: International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI), 2018, pp. 729–738.
[29] T. Mansi, X. Pennec, M. Sermesant, H. Delingette, N. Ayache, iLogDemons: A demons-based registration algorithm for tracking incompressible elastic biological tissues, International Journal of Computer Vision 92 (2011) 92–111.
[30] P. P. Sengupta, J. Korinek, M. Belohlavek, J. Narula, M. A. Vannan, A. Jahangir, B. K. Khandheria, Left ventricular structure and function: Basic science for cardiac imaging, Journal of the American College of Cardiology 48 (2006) 1988–2001.
[31] M. Jiang, M. Lu, S. Zhao, Cardiac functional assessment by magnetic resonance imaging, Cardiology Discovery 4 (2024) 284–299.
[32] D. Ouyang, B. He, A. Ghorbani, N. Yuan, J. Ebinger, C. P. Langlotz, P. A. Heidenreich, R. A. Harrington, D. H. Liang, E. A. Ashley, et al., Video-based AI for beat-to-beat assessment of cardiac function, Nature 580 (2020) 252–256.
[33] A. Vaswani, N. Shazeer, N. Parmar, J. Uszkoreit, L. Jones, A. N. Gomez, Ł. Kaiser, I. Polosukhin, Attention is all you need, in: Advances in Neural Information Processing Systems, volume 30, 2017.
[34] P. Dhariwal, A. Nichol, Diffusion models beat GANs on image synthesis, in: Advances in Neural Information Processing Systems, volume 34, 2021, pp. 8780–8794.
[35] M. Jaderberg, K. Simonyan, A. Zisserman, K. Kavukcuoglu, Spatial transformer networks, in: Advances in Neural Information Processing Systems, volume 28, 2015.
[36] D. Rueckert, L. I. Sonoda, C. Hayes, D. L. G. Hill, M. O. Leach, D. J. Hawkes, Nonrigid registration using free-form deformations: Application to breast MR images, IEEE Transactions on Medical Imaging 18 (1999) 712–721.
[37] O. Bernard, A. Lalande, C. Zotti, F. Cervenansky, X. Yang, P.-A. Heng, I. Cetin, K. Lekadir, O. Camara, M. Á. González Ballester, et al., Deep learning techniques for automatic MRI cardiac multi-structures segmentation and diagnosis: Is the problem solved?, IEEE Transactions on Medical Imaging 37 (2018) 2514–2525.
[38] V. M. Campello, P. Gkontra, C. Izquierdo, C. Martín-Isla, A. Sojoudi, P. M. Full, K. Maier-Hein, Y. Zhang, Z. He, J. Ma, et al., Multi-centre, multi-vendor and multi-disease cardiac segmentation: The M&Ms challenge, IEEE Transactions on Medical Imaging 40 (2021) 3543–3554.
[39] O. Ronneberger, P. Fischer, T. Brox, U-Net: Convolutional networks for biomedical image segmentation, in: International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI), Springer, 2015, pp. 234–241.
[40] I. Loshchilov, F. Hutter, Decoupled weight decay regularization, in: International Conference on Learning Representations, 2019.
[41] Z. Wang, A. C. Bovik, H. R. Sheikh, E. P. Simoncelli, Image quality assessment: From error visibility to structural similarity, IEEE Transactions on Image Processing 13 (2004) 600–612.
[42] R. Zhang, P. Isola, A. A. Efros, E. Shechtman, O. Wang, The unreasonable effectiveness of deep features as a perceptual metric, in: IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 2018, pp. 586–595.
[43] M. Heusel, H. Ramsauer, T. Unterthiner, B. Nessler, S. Hochreiter, GANs trained by a two time-scale update rule converge to a local Nash equilibrium, in: Advances in Neural Information Processing Systems, volume 30, 2017.
[44] T. Unterthiner, S. van Steenkiste, K. Kurach, R. Marinier, M. Michalski, S. Gelly, Towards accurate generative models of video: A new metric & challenges, arXiv preprint arXiv:1812.01717v2 (2019).
[45] X. Shi, Z. Chen, H. Wang, D.-Y. Yeung, W.-k. Wong, W.-c. Woo, Convolutional LSTM network: A machine learning approach for precipitation nowcasting, in: Advances in Neural Information Processing Systems, volume 28, 2015.
[46] Y. Blau, T. Michaeli, The perception-distortion tradeoff, in: IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR), 2018, pp. 6228–6237.
[47] L. Breiman, Random forests, Machine Learning 45 (2001) 5–32.
[48] J.-P. Thirion, Image matching as a diffusion process: An analogy with Maxwell's demons, Medical Image Analysis 2 (1998) 243–260.
S. Wang et al.: Preprint submitted to Elsevier
Page 29 of 29