arXiv:2610.09376cs.CVOct 2026

Manuscript Offprint

arXiv:2610.09376

Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI Synthesis

Yejee Shin, Geonhui Son, Jinglu Wang, Minwoo Jung, Yan Lu, Dosik Hwang

Yejee Shin ∗1^{*1}, Geonhui Son ∗†1,2^{*†1,2}, Jinglu Wang 2^{2}, Minwoo Jung 1^{1}, Yan Lu ‡2^{\ddagger2}, and Dosik Hwang ‡1,3^{\ddagger1,3}

1^{1} Yonsei University

2^{2} Microsoft Research Asia

3^{3} Korea Institute of Science and Technology

Abstract. Acquiring a complete set of magnetic resonance imaging (MRI) contrasts is time-intensive and uncomfortable for patients, despite the diagnostic value of multi-contrast imaging. This motivates synthesizing missing contrasts from those already acquired, which is an inherently 3D problem requiring anatomical coherence across axial, sagittal, and coronal planes. However, fully 3D generative models are often impractical under computational resources that scale cubically with volume size. We propose a unified Multi-Plane Autoregressive Diffusion (MPAD), a latent diffusion framework that achieves full-volume 3D synthesis using efficient plane-wise 2D operations while preserving volumetric coherence. A 3D autoencoder first compresses MRI scans into an isotropic 3D latent representation. A 2D diffusion model is then trained to reconstruct masked latent slices of the target contrast, conditioned on both source-contrast slices and unmasked target-contrast slices. During inference, we introduce plane-wise autoregressive synthesis with inter-plane priors. Slices are generated autoregressively in random order within one plane orientation to maintain intra-plane continuity, then propagated as conditioning priors to orthogonal plane orientations to enforce inter-plane consistency. Compared to 3D latent diffusion baselines, MPAD reduces training and inference FLOPs by 7×7\times and 3×3\times, respectively, while also lowering inference time and peak memory consumption. Experiments on multiple datasets demonstrate that MPAD achieves superior performance, generating high-fidelity 3D volumes and supporting one-to-many translation within a single unified model.

Keywords: Multi-contrast MRI · Synthesis · Diffusion Model

1 Introduction

Magnetic resonance imaging (MRI) examinations routinely acquire multiple contrasts, each emphasizing different tissue characteristics and pathological cues.

  • Equal contribution.

†^{\dagger} Work done during internship at Microsoft Research Asia.

‡^{\ddagger} Corresponding authors.

Y. Shin et al.

Figure

Fig. 1: Overview of the proposed 3D multi-contrast MR image translation framework. Given a source-contrast (e.g., T1), the model synthesizes a target contrast (e.g., T2 or PD) in latent space using a Multi-modal Conditioning Encoder (MCE) and a 2D diffusion model with plane-wise autoregressive synthesis. Bottom: Training FLOPs per iteration (GFLOPs), inference FLOPs per volume (TFLOPs), inference time, peak memory, and PSNR averaged across all translation tasks on the ADNI dataset.

However, collecting all contrasts for every subject increases acquisition time, elevates patient discomfort, and burdens scanner throughput; prolonged scans also heighten susceptibility to motion artifacts that degrade image quality [20,35,37]. The challenge is particularly severe for 3D volumetric acquisitions, which require substantially longer scan times due to their increased spatial coverage. This motivates the task of multi-contrast MR image synthesis, which aims to infer missing contrasts from acquired ones, enabling faster scans and more standardized imaging workflows.

Early work predominantly treated multi-contrast synthesis as a 2D image-to-image translation problem, learning mappings between contrasts such as T1-weighted to T2-weighted images. Generative adversarial networks (GANs) [11] and variational autoencoders (VAEs) [17] have been applied to convert slices between contrasts [7, 13, 14, 18, 29, 39]. Although effective in 2D applications, these methods lack modeling of 3D volumetric coherence, resulting in inter-plane inconsistencies and anatomical distortions that hinder their direct application to 3D data.

For 3D multi-contrast MR image synthesis, recent studies improve comprehensive spatial continuity by employing fully volumetric 3D generative architectures, including 3D GAN and 3D diffusion models [3,26]. Although these models better capture anatomical structure, their computational and memory requirements grow cubically with volume size. This limits scalability, especially when a single model is expected to synthesize multiple target contrasts. Latent diffusion frameworks [27] partly mitigate this by performing generation in a compressed latent space rather than directly in the high-dimensional image space. Nevertheless, less, even with latent compression, 3D latent diffusion models face substantial practical constraints, including limited computational efficiency, prolonged inference time, and challenges in maintaining synthesis fidelity across multiple contrasts, all of which are critical considerations for real-world clinical applications.

In this paper, we aim to achieve efficient 3D multi-contrast MR image synthesis using a 2D diffusion model. We propose a unified multi-plane autoregressive diffusion (MPAD) synthesis framework that enables efficient slice-wise generation while preserving 3D anatomical consistency. First, we encode MR volumes into an isotropic latent representation with a 3D autoencoder, which allows for consistent slicing along any anatomical plane orientation. Then, a 2D diffusion model is trained to reconstruct masked target-contrast slices conditioned on the source-contrast slices, unmasked target-contrast slices, and a text embedding specifying the desired target modality. By operating on 2D latent slices instead of full 3D volumes, our formulation avoids the cubic computational scaling of volumetric diffusion while reducing cost and preserving volumetric conditioning.

At inference, MPAD performs volumetric synthesis through a novel multi-plane autoregressive strategy that generates 2D slices across orthogonal planes, enforcing global 3D structural coherence. Within each plane orientation, slices are generated autoregressively in random order to maintain intra-plane continuity. Crucially, when transitioning to an orthogonal plane orientation, the previously synthesized volume serves as a conditioning prior (inter-plane prior inference), progressively enriching the anatomical context and ensuring inter-plane consistency.

This plane-wise autoregressive strategy achieves substantial computational savings. As shown in Fig. 1, MPAD reduces training FLOPs by 7×7\times and inference FLOPs by 3×3\times compared to 3D latent diffusion baselines, while also significantly reducing inference time and peak memory consumption. These improvements enable larger batch sizes, and practical deployment on standard GPUs. Beyond these computational benefits, MPAD also achieves superior reconstruction quality compared to 3D baselines. In summary, our contributions are as follows:

– We introduce a novel framework that reformulates 3D multi-contrast MR image synthesis as an efficient 2D masked-slice prediction task, overcoming the computational limits of 3D models.

– We propose a multi-plane autoregressive inference scheme that builds global 3D consistency from 2D operations using inter-plane priors.

– We demonstrate state-of-the-art efficiency and quality across multiple datasets, achieving 7×7\times and 3×3\times FLOP reductions in training and inference, significantly reduced inference time and peak memory, while improving synthesis fidelity.

References (39)