arXiv:2610.09383cs.CVOct 2026

Manuscript Offprint

arXiv:2610.09383

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo

Abstract

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction. Code and models are publicly available at: https://github.com/G2304138H/PPCAR-Net.

Keywords: 3D coronary artery reconstruction; Sparse-view reconstruction; Learning-based medical image reconstruction; Structured anatomical representation; X-ray coronary angiography; Vascular modelling.

1 Introduction

X-ray coronary angiography is fundamental for diagnosing coronary artery disease and guiding intervention. Each angiogram, however, represents a two-dimensional projection of inherently three-dimensional coronary anatomy. Foreshortening and vessel overlap can obscure spatial relationships between branches. In clinical practice, simultaneous biplane acquisitions are uncommon, and complementary monoplane views are generally acquired sequentially. Consequently, cardiologists must mentally integrate multiple views to infer three-dimensional vessel geometry (Klein et al., 1998). Conventional 3D quantitative coronary angiography partially automates this process by reconstructing anatomy from two calibrated, phase-matched projections through cross-view vessel correspondence and triangulation (Tu et al., 2010). However, sparse projections, overlapping branches, and foreshortening can make these correspondences ambiguous. We therefore investigate whether population-level patterns of coronary anatomy learned across training cases can support a plausible branch-structured 3D hypothesis when the projection evidence is ambiguous.

Existing learning-based methods commonly represent coronary arteries using neural fields, Gaussian primitives, or voxel volumes, rather than directly producing ordered coronary centrelines

Table 1: Comparison of learning-based coronary artery reconstruction methods. Per-case runtime is the complete time required to reconstruct one 3D artery from two input views, including vascular-graph extraction when applicable.

MethodNumber of input viewsOutput representationOutputPer-case runtime ↓
3D volumeConnected centrelineRadius
Iyer et al. (2023)2 or 3Dense centreline points and radii✓✓✓-
NeRF-CA (Maas et al., 2025)≥ 4Novel 2D views✕✕✕-
NerT-CA (Maas et al., 2026)≥ 3Novel 2D views✕✕✕-
SDF-CAR (Reda et al., 2026)23D implicit SDF field✓✕✕45 min
3DGR-CAR (Fu et al., 2024)≥ 23D Gaussian primitives✓✕✕63.7 s
DeepCA (Wang et al., 2025b)23D voxel✓✕✕2.69 s
AutoCAR (Zhu et al., 2025)23D voxel✓✕✕3.76 s
PPCAR-Net (ours)≥ 1B-spline centreline curves and dense radii✓✓✓121 ms

and lumen radii. Extracting vascular graphs from volumetric outputs can introduce errors that compromise downstream analysis and interpretation. We instead adopt the dense centreline-and-radius representation (Iyer et al., 2023) as the model's native output. We parameterise each dense branch centreline as a continuous cubic B-spline to ensure connectivity within each branch, while retaining dense radius values for localised radius variation. We refer to this branch-structured B-spline centreline-and-radius representation as vessel code. It is directly interpretable and editable, without requiring vascular-graph extraction from a volumetric prediction.

We propose PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that predicts vessel code through a coarse-to-fine process. Given a variable number of 2D coronary masks and their acquisition directions, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch existence, B-spline control points, and dense radius profiles. It infers a plausible branch-structured 3D hypothesis: the branch-existence predictions determine the number of active branches, the B-spline control points describe their trajectories, and the dense-radius predictions provide approximate radius profiles. Projection-guided geometry and radius refiners then sample local 2D evidence and apply learned residual corrections to the centreline geometry and radii. This feed-forward design empirically improves reconstruction accuracy without per-case optimisation, enabling sub-second inference. We train and evaluate using simulated angiographic masks generated from the ImageCAS CT angiography dataset (Zeng et al., 2023). Qualitative examples on diseased ASOCA anatomy (Gharleghi et al., 2023) and preprocessed real X-ray angiography explore anatomical and image-domain transfer, respectively. Table 1 compares the capabilities of our approach with representative learning-based methods.

The contributions of this work are:

  • We demonstrate that integrating a coronary anatomical prior learned across the training cohort with projection-guided corrections based on case-specific evidence reconstructs accurate, anatomically structured 3D coronary arteries from sparse views, without explicit point correspondence or per-case optimisation. These results suggest that learned anatomical priors provide useful constraints under ambiguity from sparse X-ray angiographic views.

  • PPCAR-Net, supported by branch-subset augmentation during training, achieves the best RCA structural and centreline reconstruction metrics among evaluated methods, with competitive volumetric accuracy and robust branch prediction. This is accomplished with sub-second inference, demonstrating both high accuracy and real-time capability.

  • We enhance the explicit branch-structured centreline-and-radius representation by incorporating a smooth cubic B-spline parameterisation of dense polyline centrelines. This adaptation leads to more coherent and accurate vessel geometry reconstructions compared to dense point predictions, while maintaining interpretability and intra-branch continuity.

References (17)