One Frame, Full Heartbeat: ECG-Free Cardiac Cine MRI Synthesis via Phase-Conditioned Flow Matching

Shiyi Wang, Ruochen Sun, Peirong Liu, Xiang Li, Fangxu Xing

Abstract

Cine cardiovascular magnetic resonance (CMR) analysis relies on multi-frame sequences capturing the full cardiac cycle. However, standard multi-frame acquisition depends heavily on electrocardiogram (ECG) gating and repeated breath-holds, posing challenges in uncooperative populations, resource-limited settings, and temporally corrupted datasets. Existing methods that synthesize full cardiac sequences either rely on explicit ECG signals to parameterize myocardium function, or employ deformable registration without physiological constraints, failing to faithfully reproduce clinically relevant dynamic metrics such as ejection fraction (EF) and ventricular contraction magnitude. We present PhaseFlow, a unified generative framework that overcomes both limitations. PhaseFlow estimates a non-linear cardiac phase signal directly from the input sequence via a segmentation-derived left-ventricular (LV) area curve, capturing the asymmetric dynamics of systole and diastole without any ECG dependency. At inference, this phase signal is provided by a pathology-specific template, informing phase-specific frame generation. A rectified flow model conditioned on the phase and slice position synthesizes the full cardiac motion trajectory in the latent space, decoded into a diffeomorphic displacement field that warps end-diastole pixel intensities directly, eliminating the reconstruction blur often accompanying the variational autoencoder. On the ACDC benchmark, PhaseFlow achieves superior physiological fidelity and image realism, with best LV volume curve R2R^{2}, structural similarity (SSIM) and generative quality (FID) among all baselines. Ablation studies confirm that each proposed component contributes measurably to the overall performance.

1 Introduction

Cine cardiovascular magnetic resonance (CMR) imaging is the clinical gold standard for quantifying ventricular anatomy and function, enabling precise physiological measurements throughout the complete cardiac cycle such as ejection fraction (EF), end-diastolic (ED) and end-systolic (ES) volumes, myocardial strains, etc. (Bernard et al. 2018). In standard clinical practice, a full CMR acquisition often requires electrocardiogram (ECG) gating and multi-breath-hold pulse sequences, a protocol unavailable in retrospective cohort studies, prohibitively costly in resource-limited settings, challenging for uncooperative population, and inapplicable when only isolated frames survive archiving. Therefore, for any specific population with consistent cardiac functional patterns, the problem of synthesizing a complete, physiologically coherent CMR sequence from any specific frame (e.g., the ED frame where the myocardium expands the most) is both clinically compelling and technically formidable: it demands recovering the full spatiotemporal trajectory of the myocardium from purely spatial information, without any explicit temporal signal.

Prior works have attempted this challenge from three directions, each with distinct limitations. Registration-based methods (Zakeri et al. 2023; Krebs et al. 2021) warp a reference frame via a predicted displacement field, but treat the frame index as a linear phase proxy, erasing the asymmetric velocity profiles of systole and diastole (Yang et al. 2024) and generalizing poorly under domain shift (Jena et al. 2024). ECG-conditioned methods (Li et al. 2025; Fang et al. 2026) restore temporal coherence but hard-depend on concurrent ECG acquisition, precisely the signal prone to absence in retrospective or resource-limited settings. Generative models, namely generative adversarial networks (GANs) (Goodfellow et al. 2014; Vukadinovic et al. 2023) and diffusion models (Ho, Jain, and Abbeel 2020; Song et al. 2021; Zhou et al. 2024; Phi et al. 2024; Algethami, Iqbal, and Ullah 2025), optimize pixel-level realism without physiological supervision and thus consistently fail to reproduce clinically relevant quantities such as EF and left-ventricular (LV) volumes (Li et al. 2025); conditional image leakage (Zhao et al. 2024) further drives them toward near-static predictions at inference.

We observe that all three paradigms overlook a key signal that is inherently latent in the CMR sequence itself: the nonlinear cardiac phase, recoverable from the per-frame LV area curve without any ECG dependency. Cardiac dynamics are intrinsically asymmetric: systole and diastole span different fractions of the cycle and proceed at markedly different velocities (Fukuta and Little 2008), and the area swept by the LV myocardium across frames encodes the true temporal dynamics, capturing the velocity asymmetry that a uniform frame-index assumption fails to. Beyond this intra-subject asymmetry, different pathological conditions also alter the characteristics of the phase trajectory in systematic ways (Zheng, Delingette, and Ayache 2019; Atehortúa et al. 2022): the rel-

∗^{*}Corresponding author.

ative timing and velocity balance of systole and diastole shift consistently across disease phenotypes, making the phase curve itself a pathology-level signature. At inference, when only one single frame is available and no sequence-derived phase can be computed, a pathology-specific template can replace this estimate, preserving ECG independence while encoding disease-level motion priors.

We present PhaseFlow, a generative framework that synthesizes full cardiac CMR sequences from a single frame by placing an ECG-free nonlinear phase at the center of a latent flow-matching architecture. In this application, we choose the ED frame as the anchor frame to generate the whole cine sequence. A frozen segmentation network derives the cardiac phase ϕt\phi_t at time t from the per-frame LV area curve, encoding each frame as pt=[sin⁡ϕt,cos⁡ϕt]\mathbf{p}_t = [\sin \phi_t, \cos \phi_t], a compact, periodicity-aware representation sensitive to the asymmetric contraction velocity that the linear phase assumption misses. A rectified flow model (Liu, Gong, and Liu 2023) then transports the ED anchor's latent features z0\mathbf{z}_0 toward the full-sequence's latent features z1\mathbf{z}_1 along a straight conditional trajectory, jointly conditioned on the cardiac phase and slice position, with single-step inference supported natively by a rectified-flow objective (Zhang et al. 2024). The predicted latent velocity is decoded by a deformation decoder into a diffeomorphic displacement field via scaling-and-squaring integration (Arsigny et al. 2006), warping ED pixel intensities directly, bypassing the variational autoencoder (VAE) (Kingma and Welling 2014) decoding phase and preserving sharpness that VAE reconstruction would otherwise blur. Training is further guided by a VolumeCurveLoss that differentiably supervises the synthesized LV volume trajectory by applying the frozen segmentation network exclusively to real CMR frames, providing physiologically grounded gradient signal without inducing the domain-shift artifacts that arise when segmentors encounter generated images.

Our main contributions are:

• ECG-free nonlinear phase estimation. A segmentation-based LV area curve yields a physiologically interpretable cardiac phase signal capturing the asymmetric dynamics of systole and diastole, with no ECG hardware required at training or inference.

• Phase-conditioned latent flow matching. A rectified flow model conditioned on cardiac phase and slice position synthesizes the complete cardiac motion trajectory in latent space via single-step inference.

• Deformation-decoded pixel synthesis. A diffeomorphic deformation decoder converts the predicted latent velocity into a per-frame displacement that warps ED pixel intensities directly, eliminating VAE reconstruction blur.