arXiv:2610.09579cs.CVOct 2026

Manuscript Offprint

arXiv:2610.09579

Gradient-Based Trajectory Optimisation over Continuous Poses for Sparse-View Cone-Beam CT

Linda-Sophie Schneider, Simon Wittl, Gabriel Herl, Andreas Maier

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Linda-Sophie Schneider, Simon Wittl, Gabriel Herl and Andreas Maier

Abstract—Trajectory optimisation for cone-beam computed tomography (CT) determines which information sparse-view scans acquire. Fixed candidate pools prevent off-grid refinement and require new object-specific precomputation for each acquisition manifold. We make every source pose an individual continuous variable and move all poses jointly by gradient ascent on the scanner's kinematic manifold. The objective combines soft-Tuy plane coverage, continuous View Covariance Loss, and an analytic attenuation-aware ray-bundle penalty. The same optimiser handles circular, limited C-arm, two-axis, and free-sphere parametrisations. On a Defrise flange, continuous selection recovers laminar defects invisible to a circular orbit, matches discrete swap search on the free sphere at the sparser budget, and leads at the denser one, with the same objective evaluated in every arm. A moderate elevation band already recovers most of the free-sphere gain at the defects, so the same optimiser transfers to bounded scanner envelopes. Photon noise preserves the ordering on the flange and compresses it on a dense fuel nozzle. Sparse-prescan planning benefits from matching prescan and planned acquisition manifolds. Selection takes seconds rather than minutes without an object-specific reconstruction basis. Prescan-planned poses were executed on a robot CT bench and reconstructed in a common frame, demonstrating feasibility but no consistent metric gain over uniform band sampling. Continuous pose optimisation incorporates attenuation and scanner constraints directly into sparse-view acquisition design.

Index Terms—Trajectory optimisation, cone-beam computed tomography, sparse-view CT, view selection, differentiable optimisation, optimal experimental design, robotic CT, industrial CT.

I. INTRODUCTION

Trajectory optimisation for computed tomography (CT) decides where the X-ray source is placed before a scan is acquired. Robot-based and multi-axis systems reach almost any pose on a two-dimensional manifold, so a trajectory is given by the poses themselves rather than by a curve through them [1], [2]. The problem becomes acute under a sparse view budget, in industrial non-destructive evaluation with long acquisition times and in interventional imaging with strict dose and acquisition-speed constraints [3], [4]. Reconstruction from few projections has been studied extensively, with analytical, iterative, and learning-based approaches [5]–[10]. Optimal source placement remains much less settled.

A natural geometric anchor is Tuy completeness [11], which guarantees exact cone-beam reconstruction if every plane through the region of interest intersects the source path. Discrete coverage scores use this condition by sampling plane normals on the sphere [12], [13], later augmented with attenuation-based validity constraints [1], [14]. Our prior work sharpens the resulting discrete selection problem with a soft coverage score, termed soft-Tuy in the following, together with complexity results and certified small-instance optima [15]. Whereas coverage scores reason purely geometrically, the View Covariance Loss Swap Search (VCLS) of Lin et al. [16] selects views by minimising a closed-form surrogate of reconstruction error and performs strongly on simulated and measured cone-beam data. Both select from a fixed discrete candidate pool, the soft-Tuy approach from arbitrary but predefined geometries, VCLS in its published implementation from a circular candidate set, although the VCL criterion itself admits arbitrary view parameters, and it additionally requires an object-specific quadratic precompute and does not model photon starvation.

A fixed pool limits the geometry to the positions it already contains, refining it only enlarges a selection problem that is already NP-complete [15], and every new acquisition manifold needs a new pool. A pool-free search alone does not resolve this. Linde et al. [17] optimise three global orbit parameters by derivative-free differential evolution, so all views move together and none can be steered towards a direction that only a single defect requires. Making each view free instead yields 3k unknowns, the sample count of a population-based search grows with that dimension, and every sample costs a full objective evaluation on the volume. What is missing is a search direction that costs one objective evaluation per step instead of one per sampled perturbation, and an analytic gradient delivers exactly that.

We remove both restrictions by making every source pose an individual continuous variable of a differentiable objective. This matters when views must be refined off-grid, when the acquisition manifold is richer than a circular orbit, and when planning should account for the attenuation the object imposes on each direction.

The objective combines three differentiable terms on the source positions. The soft-Tuy surrogate, a sampled centre-point plane-coverage score, promotes angular coverage. An analytic bundle term penalises, under a monochromatic Beer-Lambert transmission model, the directions along which the transmitted intensity is lowest. A continuous extension of the VCL information criterion of Lin et al. [16] rewards views that carry reconstruction-relevant information in the noise-free case. Coverage sees only geometry, the bundle term sees only the attenuation along its rays, and the information term assumes noise-free data. One shared objective puts all three

L.-S. Schneider and A. Maier are with the Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Germany. Correspondence to linda-sophie.schneider@fau.de.

S. Wittl and G. Herl are with the Deggendorf Institute of Technology, Germany.

into the same gradient step.

All results in this paper start the optimiser from the greedy soft-Tuy selector of [15], a geometric initialisation that needs no precompute, and refine the source poses on an idealised differentiable kinematic manifold. We realise this with four standard models, namely the single-axis circle, the limited C-arm, the two-axis gantry, and the free sphere.

This paper makes four contributions.

  • A gradient-based framework for trajectory optimisation. Every source pose is a continuous variable on an idealised kinematic manifold, so the refinement stage needs no candidate pool.

  • A differentiable objective that puts geometric coverage, attenuation, and reconstruction information into one gradient step. The absorption term has an analytic gradient and needs no step-size calibration.

  • A matched comparison against the discrete state of the art. On the free sphere our selector reaches its image quality without any object-specific precompute, so it selects in seconds where the discrete pipeline needs minutes and its margin grows with the reconstruction grid.

  • A measured robot-based study. Pose sets planned from a prescan are acquired on a custom bench and reconstructed in a common reference frame.

All proofs, the algorithm listing, and extended tables and analyses appear in the supplementary material. The code is available on GitHub.

References (53)