arXiv:2610.10102cs.ETOct 2026

Manuscript Offprint

arXiv:2610.10102

Analytical Modeling of Open- and Closed-Loop Dispersive Molecular Communication Channels with Pulsatile Flow

Theofilos Symeonidis, Fardad Vakilipoor, Timo Jakumeit, Robert Schober, Nunzio Tuccitto, Maximilian Schäfer

Theofilos Symeonidis, Fardad Vakilipoor, Timo Jakumeit, Robert Schober, Nunzio Tuccitto, and Maximilian Schäfer

Abstract—Molecular communication (MC) is a communication paradigm in which information is conveyed through the release, propagation, and reception of molecules. Many envisioned healthcare applications of MC are expected to operate inside the human body, where the cardiovascular system (CVS) may serve as the physical propagation environment and molecular transport is governed by diffusion and blood flow. Although blood flow is inherently pulsatile, most analytical MC channel models assume steady flow. In this paper, we develop a time-variant analytical model for dispersive MC channels with pulsatile flow. We derive the straight-duct response as a Normal distribution with time-variant mean and variance, capturing the combined effects of diffusion and pulsatile flow, and extend it to closed-loop channels through a wrapped-Normal representation. The model is validated against three-dimensional (3D) particle-based simulations (PBSs) for synthetic and physiologically motivated velocity waveforms. We further derive a closed-form first-order approximation for the first-arrival peak time and introduce the nondimensional indicator SRxS_{Rx} for assessing the applicability of the reduced one-dimensional (1D) model.

Our results show that pulsatility has the strongest influence when molecular transport is predominantly advective and the temporal flow variations are not averaged out, whereas stronger diffusion and faster pulsations reduce its impact on the received signal. Moreover, a PBS-based parameter sweep supports SRx≥2S_{Rx} \geq 2 as a practical criterion for the applicability of the proposed analytical model. Finally, relating the analytical assumptions to representative blood-vessel classes shows that model applicability depends not only on the transport conditions but also on physiological properties such as vessel rigidity, geometric uniformity, and blood rheology.

Index Terms—Molecular communication, closed-loop channels, pulsatile flow, advection-diffusion, Aris-Taylor dispersion.

I. INTRODUCTION

Molecular communication (MC) is an emerging interdisciplinary research field that facilitates information transfer in biological environments. MC has a wide range of potential biomedical and healthcare applications, including health monitoring, early disease detection, and targeted treatment [2]–[4]. Most of these applications are expected to operate inside the human body, specifically in the cardiovascular system (CVS), which constitutes the physical propagation channel, where signaling molecules are transported assisted by blood flow [5], [6]. Therefore, the successful design of in-body MC systems requires meaningful models that account for all relevant effects arising in this environment.

While the above models provide important insight into flow-based molecular transport, practical in-body MC systems require descriptions that are both locally accurate within individual vessel segments and compatible with the continuously circulating nature of blood flow. Locally, molecule transport is governed by the combined effects of diffusion and flow, which determine the received signal for a given transmitter (Tx)-receiver (Rx) pair within a vessel segment. At longer time scales, circulation through the vascular network may introduce long-term memory, repeated molecule arrivals, and coupling between local propagation dynamics and the overall network structure [7].

Recent studies have started to investigate MC in closed-loop systems [7], [8]. These studies demonstrate that recirculation can lead to channel characteristics that differ substantially from those of non-recirculating systems, including extended delay spreads, persistent inter-symbol interference, and topology-dependent received signals. Experimental studies further confirm the presence of these effects in closed-loop testbeds [9], [10], while the results in [9] also show that complex vascular networks can be well approximated by an equivalent single closed-loop topology, thereby enabling a simplified representation of recirculating molecular transport. Together, these observations motivate the development of channel models that retain the local propagation behavior of vessel segments while being extensible to closed-loop topologies. The equivalent-loop representation, however, is a network-level abstraction and does not imply uniform local transport conditions throughout the vascular network. Individual vessel segments may differ substantially in size and flow pulsatility. Therefore, in addition to the closed-loop representation, we also consider the straight-duct response as a model for an individual link in a vascular network, where local pulsatile-flow effects can be studied independently of recirculation.

Another important feature of in-body transport is that blood flow is generally time-varying. In particular, flow in the CVS is inherently pulsatile due to the cardiac cycle. This physiological feature is well established in the hemodynamics and fluid mechanics literature [11], [12] and is further supported by in-vivo measurements and numerical studies that provide realistic time-variant blood-flow shapes [13], [14]. Nevertheless, most

This paper was presented in part at the ACM International Conference on Nanoscale Computing and Communication, 2026 [1], doi:10.1145/3818305.3830261.

T. Symeonidis, F. Vakilipoor, T. Jakumeit, R. Schober, and M. Schäfer are with the Institute for Digital Communications, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.

N. Tuccitto is with the University of Catania, Catania, Italy.

analytical MC channel models for flow-driven or closed-loop transport assume steady flow conditions [7]–[10].

A small number of MC studies have adopted pulsatile flow models and demonstrated their influence on molecule transport and channel responses. In [2], an analytical network-based model for drug-particle propagation in the CVS under pulsatile blood flow is developed, combining a cardiovascular network model with a drug propagation network model to characterize the received particle concentration at a target site. However, the resulting network-based formulation is highly complex and does not yield a compact closed-form channel impulse response (CIR), limiting its tractability for communication-theoretic analysis. In [15], nanoparticle propagation with pulsatile flow is investigated using particle-based simulations (PBSs), revealing significant deviations compared to the steady-flow case. However, the study does not provide an analytical channel model, neglects diffusive transport, and is tailored to a specific physiological scenario, limiting its general applicability. In [16], analytical CIRs for non-Newtonian flow in a plaque-obstructed vessel are derived and complemented by detailed computational fluid dynamics simulations incorporating pulsatile flow effects. However, the study relies on numerical simulations, while the analytical models are shown to provide only rough approximations of the actual flow behavior and do not constitute a unified analytical description of pulsatile MC channels. In [17], an analytical channel model for the first-hitting-time under time-variant drift is derived. However, the model is restricted to one-dimensional propagation and focuses on first-hitting-time statistics for absorbing Rxs. Moreover, pulsatile flow is represented via a spatially uniform time-variant drift and approximations are used to obtain a tractable expression, limiting its applicability to realistic flow conditions. In addition, none of the above works provides an analytical model that combines pulsatile-flow-induced dispersion with a closed-loop channel topology.

Motivated by these observations, we propose a time-variant analytical MC channel model for pulsatile flow in the dispersive regime [18]. The model builds on recent results in [19], which show that pulsatile flow described by a Womersley velocity profile [20] can be reduced to an effective one-dimensional (1D) advection-diffusion equation with time-variant velocity and diffusion coefficient under suitable model assumptions. Based on this description, we derive the CIR for a straight MC channel with pulsatile flow, and then extend it to closed-loop systems. Unlike existing models, the resulting analytical model can both describe the received signal within an individual vessel segment and account for the possible recirculation of molecules in closed-loop MC systems. The main contributions of this paper can be summarized as follows:

  • We develop a time-variant dispersive 1D transport model for molecule propagation with pulsatile flow by combining Womersley flow with Aris-Taylor dispersion. The resulting model captures both the time-variant mean displacement and the effective dispersion induced by the interplay of diffusion and pulsatile flow.

  • We derive the CIR for impulsive molecule release in a straight duct with diffusion and pulsatile flow. The resulting expression is a Normal distribution with time-variant mean and variance, which are obtained in closed form based on the effective time-variant velocity and diffusion coefficient, respectively.

  • We extend the straight-duct solution to closed-loop MC channels by imposing periodic boundary conditions, yielding an analytical CIR for MC systems with diffusion and pulsatile flow that accounts for molecule recirculation.

  • We investigate the influence of pulsation on the first-arrival peak time, and derive a closed-form first-order approximation for the direct first-arrival peak time and evaluate its accuracy.

  • We validate the proposed analytical models by comparison to three-dimensional (3D) PBSs for synthetic and physiologically motivated velocity waveforms. Moreover, we compare the results of the proposed time-variant models with corresponding steady-flow models to investigate the effect of pulsation on the received signal.

  • We analyze the model applicability over a broad parameter range and introduce an Rx-distance-based nondimensional indicator SRxS_{Rx}, which summarizes the conditions under which the proposed model is expected to be accurate. Based on this indicator, we discuss the applicability of the proposed model to representative blood-vessel classes.

This paper substantially extends the preliminary conference version [1] in several directions. Building on the straight-duct derivation and closed-loop expression introduced there, this paper provides more detailed derivations, and places greater emphasis on the local straight-duct Rx response. We further derive a closed-form first-order approximation for the first-arrival peak time for MC systems with pulsatile flow. In addition, we introduce a regime analysis based on a nondimensional admissibility indicator and relate the resulting model assumptions to representative blood-vessel classes.

The remainder of this paper is organized as follows. In Section II, we introduce the physical channel model, starting from the underlying 3D transport formulation, and derive the effective 1D dispersive model. Section III derives the corresponding MC channel model, first for a straight duct and then for a closed-loop channel, and develops a first-order approximation for the first-arrival peak time. Section IV introduces the considered velocity waveforms and the 3D PBS setup, validates the direct Rx response for synthetic and physiologically motivated pulsatile flow scenarios, and evaluates the accuracy of the first-arrival peak-time approximation. Section V analyzes the parameter regimes in which the proposed model is applicable, introduces the nondimensional indicator SRxS_{Rx}, and discusses the implications of the model assumptions for representative blood-vessel classes. Finally, Section VI concludes the paper.

References (42)