arXiv:2610.10180cs.ROOct 2026

Manuscript Offprint

arXiv:2610.10180

Design of a Fully Actuated 4-DOF Robotic Finger With Joint-Specific Hybrid Remote Actuation

Hyojae Kang, Hyun-mok Jung, Joonho Lee, Dongil Park, Hyunmin Do, Jongwoo Park, Jeongdo Ahn

Abstract

This paper presents a fully actuated 4-DOF robotic finger using a joint-specific hybrid remote-actuation architecture. The metacarpophalangeal (MCP) joint is driven by two coordinated rigid-link transmission sets, whereas the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints are independently actuated by closed-loop wire transmissions incorporating circular rolling-contact joints (RCJs). A larger transmission radius is used at the PIP joint than at the DIP joint. The RCJ wire geometry maintains the total wire-loop length during joint rotation, and the DIP wire routing is designed so that PIP motion does not affect its differential actuation for a fixed MCP configuration. The distal wire transmission, MCP linkage, and fingertip kinematics are analytically modeled. In experiments, the transmission behavior was quantitatively evaluated from the ball-screw displacements measured using ArUco-marker tracking. MCP actuation produced measurable displacements of the PIP and DIP transmission units, whereas isolated PIP and DIP actuation with the MCP fixed supported the intended mechanical decoupling between the distal transmissions. The mean peak fingertip forces under isolated MCP, PIP, and DIP actuation were 21.28 N, 9.22 N, and 5.75 N, respectively. The resulting finger postures were also examined using objects of different geometries and sizes.

1 Introduction

Robotic hands require multiple controllable degrees of freedom (DoFs) to generate diverse finger postures for grasping and manipulation [1]. Fully or highly actuated hands preserve joint-level controllability by assigning independent actuation to multiple finger DoFs [2,3]. However, increasing the number of actuated joints also increases the number of actuators and transmission components. Packaging these components within the hand is especially restrictive in multi-DoF fingers because the available installation volume decreases toward the distal phalanges, while distal actuator placement increases the mass and structural volume carried by the finger.

Remote actuation separates actuator placement from joint location. Rigid-linkage transmission provides deterministic kinematics and direct force transmission, whereas tendon- or wire-driven transmission provides greater routing flexibility through confined structures [4–7]. Their complementary characteristics have motivated hybrid linkage-tendon architectures [8–11]. However, the appropriate transmission type can differ according to joint location and mechanical function. For a proximal multi-DoF joint such as the metacarpophalangeal (MCP) joint, a rigid-link transmission can transmit the motion of multiple proximal actuators to a multi-DoF joint while avoiding additional tendon-routing elements around the finger base. In contrast, flexible transmission is advantageous for serial distal joints because it allows actuation to be remotely located without placing actuators within the phalanges.

Extending wire transmission to multiple serial joints introduces additional requirements. Bidirectional actuation requires either passive restoration or opposing agonist-antagonist transmission paths because a wire transmits tensile force only while tensioned [12–17]. In addition, a wire driving a distal joint must traverse moving proximal joints, and configuration-dependent changes in routing length can generate unintended interjoint coupling. Recent studies have addressed these issues using antagonistic remote transmission and joint-centered routing [18–20]. A fully actuated multi-DoF finger therefore requires both independent actuation inputs and a transmission arrangement that accommodates the different mechanical requirements of the proximal and distal joints while avoiding unintended coupling between the distal joints.

This paper presents a fully actuated 4-DOF robotic finger based on a joint-specific hybrid remote-actuation architecture, combining rigid-link transmission for the 2-DOF MCP joint with independent closed-loop wire trans-

0^{0}This manuscript has been submitted for possible publication. This work was supported by the Industrial Strategic Technology Development Program (00443339) funded by the Ministry of Trade, Industry & Energy (MOTIE, Korea).

missions for the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints using circular rolling-contact joints (RCJs). This architecture retains independent actuation of all four DoFs without placing actuators in the distal finger links, while the distal wire routing prevents differential coupling between the PIP and DIP transmissions for a fixed MCP configuration. Experiments quantify the MCP-induced displacement of the distal transmission units and evaluate the mechanical decoupling between the PIP and DIP transmissions for a fixed MCP configuration, together with the fingertip force and object-interaction behavior of the fabricated finger.

The main contributions are:

  • A joint-specific hybrid remote-actuation architecture for a fully actuated 4-DOF finger, combining two coordinated rigid-link transmission sets at the 2-DOF MCP joint with remote wire transmissions at the serial PIP and DIP joints.

  • A closed-loop RCJ wire transmission that maintains bidirectional actuation and provides mechanical decoupling between the PIP and DIP transmissions for a fixed MCP configuration.

The remainder of this paper is organized as follows. Section II reviews robotic finger actuation architectures relevant to the proposed mechanism. Section III presents the mechanical design, and Section IV provides the kinematic and transmission analyses. Section V experimentally evaluates joint motion, fingertip force, and representative object interaction. Section VI concludes the paper.

References (34)