arXiv:2610.07416cs.HCOct 2026

Manuscript Offprint

arXiv:2610.07416

Knit-Structure Effects on Electromechanical Metrics and Their Correlation with Joint-Angle Estimation Error in Knitted Strain Sensors

Annika Eloranta, Zhuchenyang Liu, Iiro Naulapaa, Iida Arvola, Yao Zhang, Anna-Mari Leppisaari, Lulu Xu, Yu Xiao

Annika Eloranta 1^{1}, Zhuchenyang Liu 1^{1}, Iiro Naulapää 1^{1}, Iida Arvola 1^{1}, Yao Zhang 1^{1}, Anna-Mari Leppisaari 1^{1}, Lulu Xu 2^{2}, Yu Xiao 1^{1}

1^{1}Aalto University, Espoo, Finland 2^{2}Loughborough University, Loughborough, UK

Abstract—Knitted resistive strain sensors show strong promise for joint motion sensing in sports and rehabilitation, but the linkage between sensor design and in situ performance remains unclear. We investigate how knit structure and machine settings (e.g., stitch size) shape electromechanical properties and which metrics predict sensing performance during bending. Sensors spanning seven common knit structures at two stitch sizes were fabricated, characterized under uniaxial cyclic tension, and evaluated on a joint-emulating bending rig. Joint-angle estimation was assessed with machine-learning models, and correlations with electromechanical metrics were analyzed. Experimental results show that, among six common metrics, gauge factor and baseline resistance are largely set by knit structure, while working range, linear range, hysteresis, and cyclic stability vary only modestly across designs. Gauge factor correlates negatively and baseline resistance positively with joint-angle estimation error—mainly in lower-sensitivity designs—whereas the other metrics have weak or no predictive value. These results support using uniaxial tensile tests to screen out weak designs, while underscoring the need for joint-relevant evaluation and application-specific metrics to identify top performers.

Index Terms—knitted strain sensors; knit structure; tensile testing; joint angle estimation

I. INTRODUCTION

Human motion sensing is a key technology for applications such as rehabilitation, sports training, ergonomics, and human–computer interaction [1], [2]. Body motion is well described by joint angles because movement primarily consists of rotations of body segments about anatomical joints, providing an interpretable and comparable representation across tasks and subjects [3]. Knitted resistive strain sensors, which are stretchable and easy to integrate into textiles, can measure joint angles and their changes [4], [5], making them well suited to interpretable body-motion analysis.

Knit structure plays a central role in knitted strain sensor design: it sets the baseline deformation modes, governs how strain localizes and distributes, and shapes the evolution of conductive contacts during stretch. Consequently, the choice of structure, together with yarn selection and placement, directly influences electromechanical properties. Several studies have measured the electromechanical metrics listed in Table I for different knit structures (see Table II). However, heterogeneous test protocols and metric definitions, together with the limited set of structures evaluated, mean we still lack a systematic comparison across commonly used knit structures, yarn placements, and key machine settings (e.g., stitch size). Moreover, sensors are often selected based on metrics from uniaxial tensile tests, yet it remains unclear whether these metrics reliably predict body-motion sensing performance, such as joint angle estimation error.

This work aims to answer two research questions (RQs): RQ1: How do knit structure and machine settings like stitch size influence the electromechanical characteristics of knitted resistive strain sensors? RQ2: Which electromechanical metrics from uniaxial tensile tests reliably predict joint angle estimation error for flexion-extension (bending) motions? We use bending motions as case studies, because they are common in functional tasks, provide a clear strain-to-angle mapping, and permit controlled, single-degree-of-freedom evaluation of design effects.

To address RQ1, we fabricated sensor samples spanning seven knit structures commonly used in knitwear, each produced at two stitch sizes (14 designs total). We characterized their behavior via uniaxial cyclic tensile tests at three loading rates. We standardize sensor dimensions and yarn placement to ensure comparability. We then mounted the sensors on an elbow-emulating robot to assess how these electromechanical metrics translate to a joint-like setup. For RQ2, we trained machine-learning models to estimate joint angles from sensor signals and empirically analyzed the correlation between electromechanical metrics and joint-angle estimation error.

Below, we outline the key findings, which inform selection criteria for sensor designs suitable for motion analysis.

• Gauge factor (sensitivity) and baseline resistance are driven primarily by differences between knit structures; within-design manufacturing variability is comparatively small. Specifically, these metrics vary 8−25×8-25\times more across designs than across replicates. In contrast, working range, linear range, hysteresis, and cyclic stability vary at most 3×3\times more across designs than within one, offering limited discrimination.

• A one-step change in stitch size primarily tunes baseline resistance, with little effect on gauge factor.

  • While tensile tests are useful for screening out weak designs, they are insufficient for selecting the best performers in joint-motion sensing. Of six metrics (Table

I), only gauge factor and baseline resistance show any correlation with joint-angle estimation error, and only within the less-sensitive half of designs. The other metrics have weak or no predictive value.

For reproducibility, we will release the sensor designs, collected measurements, and the designs of the testing tools.

References (19)