arXiv:2610.07438cs.HCOct 2026

Manuscript Offprint

arXiv:2610.07438

Artifact removal improves electrodermal waveforms but not downstream classification in a virtual-reality balance task

Haochen Chai, Qixu Zhu, Siyao Li, Fangfang Jiang

Abstract

Artifact removal routinely precedes the classification of electrodermal activity (EDA), on the assumption that a cleaner signal supports a better decision. We tested this assumption in a virtual-reality (VR) balance-disturbance task. A residual gating network was trained on a benchmark with expert-corrected EDA, frozen, and applied to VR recordings, where raw and gated signals were classified by five published time-series methods under identical leave-one-participant-out evaluation. On the benchmark the gate detected artifacts well (median record AUROC 0.94) and reduced error inside artifact regions by 17.8%. In the VR task it did not improve classification. Changes in balanced accuracy ranged from -1.35 to +0.93 percentage points, no classifier improved and two lost accuracy, and all five were equivalent to raw input within ±3.32 points. The benefit was lost between waveform and decision. The correction that lowered waveform error also reduced skin conductance response detection in all 43 benchmark records. Processing left 92.8% of predictions unchanged, and the predictions it did change were corrected and corrupted at similar rates. The VR recordings also carried little contamination (an estimated 4.6% of samples), and even perfect localization of deliberately injected artifacts recovered only 3.3 points in the most sensitive classifier. A pooled association between artifact level and accuracy (11.3 points) disappeared within participants (0.1 points), showing how differences between people can make cleaning look useful. Preprocessing should be judged by the decision it supports, against an unprocessed arm. Keywords: electrodermal activity; artifact removal; virtual reality; equivalence testing; preprocessing evaluation; negative result

1 Introduction

Physiological sensing lets an immersive virtual-reality (VR) system follow how its user is responding without interrupting the interaction. Electrodermal activity (EDA) suits this role. It is inexpensive to record with wearable sensors and tracks sympathetic arousal through tonic skin conductance and transient skin conductance responses (SCRs) [1–3]. It is also easily disturbed by movement, because pressure and shifts at the electrode produce deflections that resemble responses [4, 5]. Applied pipelines therefore remove artifacts before inference, and the step is seldom questioned. We ask whether it improves the decision the system is built to make.

There is good reason to doubt that it does. A balance disturbance changes movement and physiology at the same moment, so a correction that removes motion-related variation can also remove information that separates one user state from another. More fundamentally, an artifact handler is trained and scored on how closely it reproduces a clean waveform, whereas a classifier relies on whatever features separate its classes, and nothing guarantees that the two objectives agree.

Processing choices are known to shape EDA results. Multiverse analyses of SCR quantification give different effect estimates under different pipelines [6, 7], filtering changes sensitivity [8], and the choice of model inversion changes predictive validity [9, 10]. Studies that compare processed with unprocessed signals on the same task are few and point in different directions, one reporting a benefit [11] and another a small loss [12]. In EEG, automated cleaning has rarely increased condition effects [13], and component-based artifact rejection did not improve deep-network decoding in three brain–computer interface tasks [14]. In applied EDA work the comparison is usually absent. Of 13 studies in a documented sample that removed EDA artifacts before a downstream task, 2 compared processed and unprocessed signals with the same model and protocol (section 2.7); in the others, the benefit of cleaning was taken for granted.

We tested artifact removal against the task it is meant to serve. A continuous residual gate was trained on a public benchmark with expert-corrected EDA [15, 16], frozen, and transferred to a VR balance-disturbance corpus [17], where raw and gated signals were classified by five published time-series methods under identical participant-disjoint folds. The gate performed well on the benchmark and gave no benefit in VR. Because the benchmark supplies expert references and the VR corpus supplies task labels, we could follow the expected benefit from contamination to decision and show where it was lost: in event preservation, in the direction of feature changes, in decisions that did not change, and in the small amount of contamination there was to remove. We also show that a pooled association between artifact level and accuracy, the kind of evidence often used to justify cleaning, reflects differences between participants rather than a benefit of cleaning.

References (34)