arXiv:2610.07515ProCut: Probabilistic Cutting Topology for Autonomous Electrosurgical Tissue Dissection
Xiao Liang, Fei Liu, Florian Richter, Genie Rubaiyat, Michael Yip
Abstract—Accurately modeling and tracking the deformation of soft tissue is critical for a wide range of interventional and surgical procedures. However, current methods struggle in scenarios involving topological changes—such as cutting and dissection—due to the inherent non-linearity and discontinuity introduced by explicit changes in connectivity. In this work, we present a novel, fully differentiable framework that enables robust estimation and modeling of topological changes during deformable tracking. Our method introduces a continuous, sigmoid-based formulation to smooth the otherwise discrete event of tissue cutting, making it amenable to gradient-based optimization within a differentiable Position-Based Dynamics (PBD) simulation. To account for uncertainty and improve robustness in the presence of noisy visual data, we incorporate Stein Variational Gradient Descent (SVGD) for particle-based probabilistic inference, generating multiple hypotheses for topological state estimation. Building on this foundation, we develop an autonomous dissection algorithm for thin-shell tissues that leverages topological updates to guide closed-loop cutting trajectory control. We evaluate our approach in both simulated and real-world electrosurgical environments, demonstrating significant improvements in topological estimation accuracy and dissection precision over existing methods. Our results highlight the potential of this framework to advance automation in soft-tissue surgical procedures by enabling reliable perception and control in the presence of complex structural changes.
I. INTRODUCTION
Modeling and tracking of deformable objects, such as soft tissue and human organs, play a crucial role in various interventional and surgical procedures [1]. The process includes capturing soft bodies deformation [2] and enabling understanding and prediction of physical behaviors of the deformable objects over time [3]. In interventional procedures with CT and MRI data, deformable tracking methods elevate the reliability of procedures such as radiation therapy [4] and image-guided biopsy [5]. In image-guided surgery, this technology assists surgeons by providing additional visual guidance [6], reducing their cognitive load. Recent efforts in surgical autonomy such as tissue manipulation [7], blood suction [8], and suturing [9], have also relied on deformable tracking algorithms applied to endoscopic image data, serving as crucial cues for the autonomous agents. Despite being broadly used, a significant limitation remains: existing deformable modeling and tracking methods struggle to handle tissue connectivity changes that is ubiquitous in surgery. This limitation poses a challenge for further advancement in bringing autonomy to surgery including accurate tissue visualization after dissections or even autonomy of tissue dissection itself.
Most prior methods in deformable tracking and modeling rely on visual inputs, whether optimization-based [10], [11]

Cautery Dissection
Topology Estimation
State Tracking
Fig. 1. Overview of our autonomous tissue dissection system. (Top) The robot performs electrosurgical dissection. (Bottom left) Our method estimates the cutting topology using probabilistic, gradient-based inference on a canonical reference frame. (Bottom right) The estimated topology enables accurate tracking of tissue deformation, providing critical feedback for precise dissection control.
or learning-based [12], [2], commonly incorporate spatial smoothness objectives to encourage physically plausible deformation estimation. However, these computer vision techniques do not explicitly consider topological changes leading to over-regularizing and inaccuracies in regions with topological changes. Other works integrate visual observations with physics-based modeling, including physics-based deformable registration [13] and real-to-sim state estimation [14]. These approaches are also limited by their underlying physics models, which are not designed to accommodate topological changes. Explicit estimation of topological changes has been explored through direct deletion of mesh edges based on a heuristic-strategy [15], [16] and learning approaches [17]. However, these approaches are limited in robustness due to their sensitivity to observation noise, reliance on handcrafted rules or training data, and reduced generalization ability to unseen topological variations.
To overcome these limitations, we propose ProCut, a differentiable formulation for tracking, modeling, and applying topological changes during tissue cutting tasks. Tissue cutting introduces a highly non-linear transformation, as it involves explicit removal of mesh connectivity. Our approach makes this non-linearity amenable to gradient-based optimization by smoothing the connectivity change using a sigmoid function. formulation is integrated into a differentiable physics simulator, Position-Based Dynamics (PBD), for deformable tracking and modeling [3]. Additionally, we incorporate the estimation of topological changes into a particle-based probabilistic estimation algorithm, Stein Variational Gradient Descent (SVGD), enabling multiple hypotheses to initialize the optimization process and providing uncertainty of the estimated topological change. Leveraging this fully differentiable framework, an autonomous dissection algorithm is devised that is tailored to thin-shell tissue, using topological updates as cues for closed-loop dissection trajectory control. In summary, the main contributions of this work are:
• A differentiable cutting topology model that represents tissue connectivity through a smooth, gradient-compatible formulation, enabling end-to-end optimization of dissection trajectories within a differentiable simulator.
• A probabilistic topology estimator based on SVGD that maintains a distribution over cutting curves from visual observations, providing calibrated uncertainty estimates to guide closed-loop dissection under deformation and observation noise.
• An autonomous electrosurgical dissection pipeline integrating the above components into a real-time perception-planning-control loop, validated in both simulation and on ex-vivo tissue, and demonstrating recovery from topology estimation errors without replanning from scratch.
Autonomous Cutting and Dissection. [27] proposed a vision-based closed-loop controller to ensure accurate knife cutting depth along a predefined trajectory. [28], [29] developed reinforcement learning algorithms to simultaneously perform tensioning and cutting on surgical gauze pads. Electrosurgical dissection is more often used in tissue dissection in robotic surgeries. For instance, [30] experimented with a near-infrared marking method for electrosurgery on porcine tongue samples. [31] introduced a suction gripper to retract tissue, facilitating electrocautery procedures. Similarly, [32] focused on dissection assistance that helps reveal the surgical site during electrocautery procedures. [33] proposed a framework that leverages semantic segmentation and key-point detection for electrocautery along tissue boundaries. Furthermore, [34] designed a reinforcement learning-based approach to control a cautery tool to remove tissue attachments. While these methods demonstrate progress in automating Electrosurgical dissection tasks, they are largely constrained to controlled environments and do not account for real-world challenges such as noise, disturbances, and changing tissue topology.
III. PRELIMINARIES
ProCut builds off previous work in differentiable simulation for tissue modeling and tracking [3]. Let be a mesh of a thin-shell soft tissue where is a set of vertices in , and set contains all triangle faces of the mesh. Each triangle face contains three vertices . We denote as our forward simulation step where is the applied control to the tissue, defines the stiffness of the thin-shell soft tissue, and is the surface point cloud observation of the real tissue.
We use a quasi-static Extended Position-based Dynamics (XPBD) simulation to model thin-shell soft tissues. The simulator is based on geometric constraints which directly update the position of the thin-shell soft tissue through constraint satisfaction. The two geometric constraints used in this work are distance to simulate springs and an observational real-to-sim constraints. The distance constraints is defined as
is the connectivity graph of the mesh. It contains all pairs of vertices that are connected by an edge, as well as all pairs of non-neighboring vertices of two adjacent triangle faces for simulating pseudo bending constraints [35]. Every distance constraint is associated with a stiffness value . Note that we adopts a variable stiffness formulation which is useful to model the non-linear dissection effects later. The real-to-sim constraint enforces similarity between mesh vertices and the current observed point cloud. It is defined by the chamfer distance between mesh vertices and the tissue point cloud
(2)
Algorithm 1: Autonomous Tissue Dissection
Input : Planned cutting path , Initial and tensioning grasping point
1 Grasp tissue at and move to tensioning position
2
3
4 for in do
// Execute a dissection action
5
6
7 if then
8 Move tooltip to
9 for in do
10
11 and localMeshSurface( )
12 Move relative with zigzag pattern, keep orientationR
13 // Estimate cutting outcome
14
15
16
17 // Update cutting plan
18 if then
19 Cutting end point of
20
This constraint encourages the similarity between the simulation and the visual observation.
In our simulation, we also incorporate a robotic gripper which grasps and directly controls a portion of the thin-shell soft tissue. The gripper's position, , is assumed to stay grasping to the same location the entire time series. Therefore, we search for the k-th nearest vertices in closest to and apply a displacement is force equal to to those vertices every time simulation timestep. Putting it all together, our forward simulation step is solved for with the following optimization problem:
where finds the k nearest vertices. Our simulator solves the optimization problem iteratively using Gauss-Seidal method. For convenience later, we introduce a variant of our simulation step that solves Eq. 3 but without terms. We directly differentiate through the optimization iterations to solve for any partial derivatives, , , , providing a differentiable simulator.

(a)
(b)
Fig. 2. Key representations that enable differentiable optimization of the cutting topology. (a). A mesh representing tissue that is manipulated and cut by a robot. (b). In the tissue's canonical mesh representation M, a cutting curve S affects the constraint stiffness of its surrounding mesh edges. Edges that are closer to the curve will have smaller stiffness to achieve similar effect as if the edges are cut.
IV. METHODS
We parameterize a cut as S, and integrate it into our simulation to satisfying geometric constraints that makes the mesh behaves like real soft tissues. Furthermore, we ensure the cut is end-to-end differentiable, i.e. can be computed, hence integrating topological changes in a differentiable manner. We leverage the differentiability of the topological changes into our real-to-sim framework for tissue which ultimately leads to an algorithm that solves two optimization problems simultaneously from observed point cloud: one that estimates the mesh state, and another that estimates the posterior probability of the cut. Alg. 2 gives an overview of the estimation algorithm. We present an autonomous algorithm summarized in Alg. 1 that utilizes the estimation results for doing feedback control.
A. Canonical Representation and Cutting Mechanism
Our framework relies on a simple intuition that tissue dissection outcome can be modeled by reducing the regional distance constraints stiffness at the dissected area. For example, an edge has a zero stiffness value if it is “dissected” so its distance constraint no longer needs to be satisfied in Eqn. 3. We parameterize outcomes of a cut as a curve that lies on the manifold of the canonical mesh , as illustrated in Fig 2. The cutting curve affects the stiffness parameters such that edges that are close to the curve have smaller stiffness, and have larger stiffness values otherwise.
Canonical representation: We choose a mesh's planar parametrization as its canocial representation. Specifically, we use the Least-squared Conformal Mapping (LSCM) planar parameterization technique to construct a canonical representations. At time , let be the LSCM parameterization that maps 3D mesh vertices to 2D planar coordinates . Given points on the canonical 2D domain, we define an inverse map that retrieves the corresponding point on the deformed mesh at time , based on its barycentric coordinates within the triangle it lies in. The inverse mapping is defined as:
where are the vertex indices of the triangle in which lies, and are computed as
Cutting mechanism: We define a cutting curve on the canonical mesh and model the spatially-varying stiffness as a function of distance to this curve. For each distance constraint pair , the stiffness is defined as:
where is a distance function to a curve which is a part of the cut. denotes a sigmoid function, and are tunable hyper-parameters controlling the decay of stiffness. This formulation supports multiple cutting curves on the same tissue by selecting the minimum stiffness from each curve. Given a set , the final stiffness is
Our formulation based on reducing the stiffness associated with a cutting region to is fully differentiable, i.e. exists. Therefore, the full gradient for the differentiable simulation is be computed via chain rule, where is computed in the same manner as our prior work [36].
Curve Parameterization: We explore both linear and quadratic Bézier to parametrize the cutting curve. A linear Bézier curve is represented with two control points , with path . The minimum distance from a point , its minimal distance to curve to this line segment is
For quadratic Bézier curves defined by three control points , the path is:
(9)
Though an analytical distance function exists, we found it numerically unstable during back-propagation in practice. Instead, we approximate its distance function by discretizing quadratic Bézier curve into line segments and composing their distance functions together:
(10)
where n is the number of line segments that we tune. This approximation not only stabilizes optimization but also enables
Algorithm 2: Cutting Curves Estimation
Input : Mesh state , cutting curve prior , previous cutting curves S, gripper position u, iteration I, number of particles N.
1
2
3 for i in [1, ..., I] do
4
// SVGD update step
5
6
// Update mesh states
7 for j in [1, ..., N] do
8
9
10
11
12 return
use of higher-degree curves. In practice, we leverage both linear and quadratic representations by first bootstrapping the estimation with a linear curve and then refining it to a quadratic curve after a set number of iterations.
B. Cutting Curve Estimation
We estimate the curve parameters, S, from point cloud data in a probabilistic fashion. The posterior over cutting curve parameters and the surface tissue observation can be computed from Bayes' rule where the is the prior distribution over the cutting curves. The likelihood term is computed the physics model that maps cutting parameters to expected observations. Specifically, we model the observation likelihood with a forward simulation based on a known previous tissue state , leading to a predicted hidden state . The likelihood becomes:
The observation model represents the likelihood of a surface point cloud given a simulated mesh state. Inspired by [37], we consider mesh vertices as centroids of a Gaussian Mixture Model (GMM), and surface point cloud as data generated by the GMM. The density function is
(12)
In the above equation, individual effect of GMM centroids become smaller when two points are further apart. Therefore, for computation efficiency, we further approximate it to only consider the K-nearest GMM centroids
Finally, the observation model is computed .
We use a set of particles to represent the posterior distribution of cutting curves due to their flexibility in capturing a wide range of distributions rather than a parametric model. To update the particles and solve for the distribution, we use Stein Variation Gradient Descent (SVGD). It has the following update rule
(14)
represents a Radial Basis Function (RBF) kernel applied to the flattened curve parameters .
The mesh state is updated iteratively during Bayesian optimization by simulating tissue states in parallel with across particles and selecting the one that best satisfies the real-to-sim constraint in Eq. 2. To prevent exponential growth in particle count as new cutting curves are added to S, we maintain a fixed number of particles by greedily selecting the best one using the same heuristic. Each new particle set inherits prior knowledge and focuses on representing the most recent cutting curve.
C. Autonomous Tissue Dissection
We develop an autonomous dissection algorithm for thin-shell tissue, outlined in Alg. 1, which leverages cutting curve estimation to guide robot actions that closely follow the target trajectory while respecting tissue deformation
Given a goal trajectory on the canonical mesh , each robot action dissects a segment between two waypoints. After performing an action, a new cutting curve is estimated (line 13-15). Let be a known starting point, or an estimated ending point of a previous cutting curve, the estimation algorithm uses a prior for initialization:
where linear and quad are chosen depending on the curve representation. The estimated cutting curve facilitates more accurate tissue tracking and a controller updates future actions using the new curve's endpoint to reduce trajectory deviation. (line 16-17).
We uses velocity control to execute each robot action (line 5-12). To compute velocities, a segment is further interpolated into smaller way-points . These are mapped to the deformed mesh using Eq. 4, and end-effector velocities are computed as differences between consecutive waypoints Then,

Ground truth
Known cut
&
Estimated
Fig. 3. Comparison of topology estimation results from three methods. WB roughly predicts the location and shape but lacks accuracy due to wrong optical flow prediction. HB is highly sensitive to observation noise, leading to many outliers. In contrast, our method achieves accurate topology estimation and enables the most realistic tissue state tracking.
the robot’s end-effector velocities in Cartesian’s space is calculated as differences between every two smaller way-points. To ensure robust dissection, we add motion along the tissue’s normal direction, producing a zig-zag pattern, and constrain the tool tip to point against the surface normal. Throughout the whole cutting process, the grasping point remains fixed at a predefined tensioning position .
V. EXPERIMENTS & RESULTS
The performance of the proposed method is tested in an electrosurgery scenario where a real thinshell tissue is dissected by an cautery spatula within the da Vinci Research Kit (DVRK) [38]. We evaluate the proposed cutting curve estimation and feedback control algorithm separately. Additional studies are done in simulated environment to analyze the proposed dissection pipeline.
A. Baselines and Metrics
The proposed method’s estimation accuracy is compared against two adapted previous methods. They are (1). WB: a image warping-based baseline inspired by [17] that warps a hand-labeled incision mask to the reference frame with optical flow predicted from [39]. A quadratic Bézier curve is found using least-square fitting to the warped mask. (2). HB: a heuristic-based incision detection method similar to [15]. It removes a mesh edge if it stretches more than a certain ratio threshold over the average of its neighbors during registration to point clouds.
TABLE I CUT ESTIMATION ACCURACY OF COMPARISON METHODS IN TERMS OF INTERSECTION-OVER-UNION (IOU) BETWEEN DILATED PREDICTION AND DILATED GROUND TRUTH CUT.
| WB | HB | ProCut (Ours) | |
|---|---|---|---|
| Accuracy (IoU) | 0.54 ± 0.23 | 0.25 ± 0.08 | 0.68 ± 0.11 |

Fig. 4. Ablation results of comparing variants of our method initialized with different noise level. Data of Init indicates initialization errors. Gradient-descent method (GD-LQ) is sensitive to initialization. Estimation with linear representation (SVGD-L) leads to lower accuracy, whereas quadratic representation alone (SVGD-Q) is accurate but not robust to larger initialization error. Combining SVGD with a linear to quadratic refinement strategy (SVGD-LQ) achieves good accuracy and robustness.
Cutting topology estimation accuracy is evaluated using an Intersection over Union (IoU) metric
where are set of edges that are removed by estimation methods and manually labeled ground truth cutting curves. We also dilate the both edge sets to reflect the cases when two curves roughly matches but has small intersection. For dissection trajectory accuracy, we compute the error as the Euclidean distance between corresponding positions sampled at uniform arc-length intervals along the desired trajectory and labeled resultant trajectory in canonical frame.
B. Estimation Performance
Accuracy of comparison methods are estimating the dissect curve on a thin-shell tissue in an ex-vivo setting. In the experiments, a gripper tool retracts the pre-dissected tissue following a pre-defined trajectory to deform it. Note that, only in these experiments, the tissue is dissected before retraction so that ground truth cutting curves can be labeled.
Table. I shows an overall accuracy of comparison methods on 5 different test cases involve real chicken skin tissue. As our method relies on an initialization, we report its performance by averaging 10 experiments where uniform initialization noise of is added by perturbing the start and end points of the ground-truth curve. Overall, our method has on average the highest cutting topology estimation accuracy. This advantage is primarily attributed to the robustness of the gradient-based probabilistic estimation framework. Fig. 3 illustrates representative results from the comparison methods. WB depends heavily on the accuracy of optical flow predictions and tends to fail when there are large pixel displacements. HB is capable of capturing both the position and shape of topological changes but is prone to generating outliers due to its sensitivity to observation noise. In contrast, the proposed approach constrains the topology to a curve representation, enabling it to estimate topological changes robustly even in the presence of noise.

Fig. 5. Comparison of results from open-loop and the proposed method in simulation. (a)~(c) cases have target cutting patterns of line, arc, and snake shape shown as the boundaries of two colors. The 1st row shows dissection error over time of 10 repetitions. The open loop method doesn't execute trajectory accurately and couldn't separate completely due to errors. The proposed method is able to follow desired pattern accurately.
We evaluate the robustness of our method under varying initialization noise levels, with uniform noise of , , and . As shown in Fig. 4, our method (SVGD-LQ) maintains high IoUs of 0.68, 0.67, and 0.62, respectively. Ablation results confirm that combining SVGD with linear-to-quadratic refinement improves accuracy over linear-only (SVGD-L), and SVGD offers greater robustness to large initialization errors compared to gradient descent (GD-LQ) and using only a quadratic representation (SVGD-Q).
C. Autonomous Dissection Experiments
We evaluate the proposed autonomous dissection algorithm in thin-shell tissue cutting task in both simulated and real-world scenarios. In both scenarios, a human operator command a desired cutting pattern either on the canonical space or on the image space. One tissue gripper retracts a thin-shell tissue in a pre-defined direction to tension it for ease of dissection, and a electrical cautery spatula executes the cutting trajectory. We assume that the robot produces error due to imperfect mechanical properties and inaccurate calibration [40], which likely results in deviation of cutting trajectory without a proper feedback mechanism.
Simulation Results: We simulate robot kinematic error by a zero-mean Gaussian noise in robot end-effector position. A calibration error is introduced by a residual transformation to the robot base. Observation noise is added to perturb every points in surface point

Fig. 6. This figures shows an example flow of robot autonomous dissection using the proposed method. The robot utilizes the proposed method's tissue tracking capability to perform eauteryelectrosurgical dissection. It inevitably makes error due to motion noise and calibration error. Our topology estimation method identifies the dissection error and updates the dissection plan. This process can be repeated until the dissection trajectory is met or when the estimated error is small enough. In this procedure, tissue retraction is tele-operated.
TABLE II RESULTS OF REAL TISSUE DISSECTION. Succ, Recov, Seg-Fail, Est-Fail INDICATES SUCCESSFUL DISSECTION, ESTIMATION ENABLED RECOVERY, FAILURE DUE TO IMAGE SEGMENTATION, AND ESTIMATION FAILURE.
| # Trials | Succ | Recov | Seg-Fail | Est-Fail |
|---|---|---|---|---|
| 10 | 50% | 20% | 20% | 10% |
cloud. We set in the simulated experiments. We designed three dissection patterns with increasing level of complexities, they are Line, Arc, and Snake. Results of comparing an open-loop method and the proposed close-loop dissection algorithm is shown in Fig. 5. The open-loop method is implemented from Alg. 1 by removing its topology estimation and trajectory update. It deviates significantly from the desired trajectory and doesn't complete the dissection task due to noise and error. In comparison, our method is able to correct its dissection trajectory once it deviates from the desired one through estimation of cutting topology and tissue state, maintaining a lower dissection error over time. Experiments for each dissection patterns are repeated for 10 times.
Real tissue Experiments: In the real tissue dissection experiments, the robot autonomously dissect a piece of thin-shell chicken skin. The autonomous dissection process is shown in Fig. 6. Each trial began with a human operator annotating the desired dissection path on an endoscopic image. Then they grasp and retract the skin tissue to create tension around the dissection area through tele-operation. During autonomous execution, our method continuously tracks the tissue's pose to guide each cutting action, and after every dissection step it predicts the resulting cutting curve, detects any deviation from the plan, and updates the subsequent trajectory accordingly. The real-world experiments is repeated for 10 times and the results are shown in Table. II A trial was deemed successful if the skin was cleanly separated into two pieces along the annotated path. Our system achieved a success rate. Additionally in trials, the proposed estimation algorithm is able to detect that the tissue is not fully dissected, potentially enabling further dissection actions to fix the error. The remaining of trials failed outright, with attributable to large image-segmentation errors and to inaccuracies in the cut-curve estimation. In each experiment, a dissection target consists of two linear segments on a chicken skin tissue, with total length of around 5 centimeters.
D. Implementation Details
The proposed method is implemented in PyTorch and tested on a machine with RTX 3090 GPU. The tissue mesh contains 1000 and 2000 vertices in the real and simulated experiment respectively. All estimation experiments have 30 SVGD particles, and is ran for 200 steps. Dissection experiments have 10 SVGD particles and is ran for 100 steps. Linear representation is used for first half of the total steps and quadratic representation is used for refinement. An estimation step in a real dissection experiment takes around 0.3s. The algorithm updates tissue state after every five topology estimation steps. Point cloud reconstruction of the tissue surface is achieved by using existing semantic segmentation [41], [42] and stereo disparity estimation [43] techniques.
E. Limitations
While ProCut demonstrates robust closed-loop dissection on thin-shell tissue, several limitations remain. First, our simulation models the mechanical effects of cutting through localized stiffness relaxation but does not capture the thermal and electrical physics of electrosurgery; consequently, the impact of power settings, duty cycle, and carbonization on cut quality is not predicted by the simulator and must be tuned empirically. Second, our real-tissue evaluation is limited to thin, homogeneous samples (chicken skin); extension to multilayer or heterogeneous tissues, such as fascia over fat or vessel-laden membranes, would require modeling layer-wise stiffness and depth-aware cut termination, which we leave to future work. Finally, tissue tensioning is currently established once before cutting and held fixed; adaptive retensioning [16] in response to topology changes can be added to improve the dissection outcome.
VI. Conclusion
In this work, we presented ProCut, a novel framework that integrates differentiable physics and probabilistic inference to enable robust estimation of dissection topology in autonomous electrocautery procedures. By introducing a differentiable representation of cutting curves within a Position-based Dynamics (PBD) simulation and leveraging Stein Variational Gradient Descent (SVGD) for particle-based inference, our method effectively models and updates tissue topology. Our method achieves superior accuracy in both simulation and real-world surgical settings, outperforming prior techniques in terms of robustness and precision. We developed an autonomous dissection pipeline for thin-shell tissues that tightly couples cutting estimation with closed-loop feedback control. The system is capable of tracking and adapting to evolving tissue states, improving the reliability of robotic tissue dissection.
While our approach has been demonstrated on thin-shell tissues, the core idea of integrating differentiable physics with probabilistic inference for topology estimation is broadly applicable. By adapting the underlying topology representation, this framework can be extended to other scenarios, such as [32] and deformable attachments [44]. Additionally, the estimation algorithm can be enhanced to detect finer-grained topological changes and operate at higher update frequencies. This could be achieved through the use of dense visual tracking techniques [45] and more sophisticated GPU acceleration [46].
Our method lays the foundation for more advanced autonomous dissection and tissue manipulation tasks. Future work includes integrating our estimation framework with adaptive control policies and extending it to broader surgical scenarios. Ultimately, this approach has the potential to significantly enhance the precision and reliability of autonomous surgical procedures.
REFERENCES
[1] A. Schmidt, O. Mohareri, S. DiMaio, M. C. Yip, and S. E. Salcudean, "Tracking and mapping in medical computer vision: A review," Medical Image Analysis, p. 103131, 2024.
[2] S. Gong, Y. Long, K. Chen, J. Liu, Y. Xiao, A. Cheng, Z. Wang, and Q. Dou, “Self-supervised cyclic diffeomorphic mapping for soft tissue deformation recovery in robotic surgery scenes,” IEEE Transactions on Medical Imaging, 2024.
[3] X. Liang, F. Liu, Y. Zhang, Y. Li, S. Lin, and M. Yip, “Real-to-sim deformable object manipulation: Optimizing physics models with residual mappings for robotic surgery,” in 2024 IEEE International Conference on Robotics and Automation (ICRA). IEEE, 2024, pp. 15471–15477.
[4] J. D. Tascón-Vidarte, L. B. Stick, M. Josipovic, S. Risum, J. Jomier, K. Erleben, I. R. Vogelius, and S. Darkner, “Accuracy and consistency of intensity-based deformable image registration in 4dct for tumor motion estimation in liver radiotherapy planning,” PLOS ONE, vol. 17, no. 7, pp. 1–15, 07 2022. [Online]. Available: https://doi.org/10.1371/journal.pone.0271064
[5] K. Nakamura, K. Matsumoto, C. Inoue, E. Matsusue, and S. Fujii, "Computed tomography-guided lung biopsy: a review of techniques for reducing the incidence of complications," Interventional Radiology, vol. 6, no. 3, pp. 83–92, 2021.
[6] S. Bernhardt, S. A. Nicolau, L. Soler, and C. Doignon, “The status of augmented reality in laparoscopic surgery as of 2016,” Medical image analysis, vol. 37, pp. 66–90, 2017.
[7] J. Hu, D. Jones, M. R. Dogar, and P. Valdastri, “Occlusion-robust autonomous robotic manipulation of human soft tissues with 3-d surface feedback,” IEEE Transactions on Robotics, vol. 40, pp. 624–638, 2023.
[8] F. Richter, S. Shen, F. Liu, J. Huang, E. K. Funk, R. K. Orosco, and M. C. Yip, “Autonomous robotic suction to clear the surgical field for hemostasis using image-based blood flow detection,” IEEE Robotics and Automation Letters, vol. 6, no. 2, pp. 1383–1390, 2021.
[9] M. Kam, H. Saeidi, M. H. Hsieh, J. U. Kang, and A. Krieger, “A confidence-based supervised-autonomous control strategy for robotic vaginal cuff closure,” in 2021 IEEE international conference on robotics and automation (ICRA). IEEE, 2021, pp. 12261–12267.
[10] S. Lin, A. J. Miao, J. Lu, S. Yu, Z.-Y. Chiu, F. Richter, and M. C. Yip, “Semantic-super: A semantic-aware surgical perception framework for endoscopic tissue identification, reconstruction, and tracking,” in 2023 IEEE International Conference on Robotics and Automation (ICRA), 2023, pp. 4739–4746.
[11] S. Saha, Z. Liang, S. Lin, J. Lu, M. Yip, and S. Liu, “Based: Bundle-adjusting surgical endoscopic dynamic video reconstruction using neural radiance fields,” arXiv preprint arXiv:2309.15329, 2023.
[12] X. Liang, S. Lin, F. Liu, D. Schreiber, and M. Yip, “Orrn: An ode-based recursive registration network for deformable respiratory motion estimation with lung 4dct images,” IEEE Transactions on Biomedical Engineering, vol. 70, no. 12, pp. 3265–3276, 2023.
[13] R. Werner, J. Ehrhardt, R. Schmidt, and H. Handels, “Patient-specific finite element modeling of respiratory lung motion using 4d ct image data,” Medical physics, vol. 36, no. 5, pp. 1500–1511, 2009.
[14] P. Sundaresan, R. Antonova, and J. Bohg, “Diffcloud: Real-to-sim from point clouds with differentiable simulation and rendering of deformable objects,” 2022.
[15] C. J. Paulus, N. Haouchine, S.-H. Kong, R. V. Soares, D. Cazier, and S. Cotin, “Handling topological changes during elastic registration: Application to augmented reality in laparoscopic surgery,” International journal of computer assisted radiology and surgery, vol. 12, pp. 461–470, 2017.
[16] C.-P. Wang, C. Chen, X. Liang, S. Atar, F. Richter, and M. Yip, "Feedback matters: Augmenting autonomous dissection with visual and topological feedback," arXiv preprint arXiv:2510.04074, 2025.
[17] T. François, L. Calvet, C. Sève-d'Erceville, N. Bourdel, and A. Bartoli, "Image-based incision detection for topological intraoperative 3d model update in augmented reality assisted laparoscopic surgery," in Medical Image Computing and Computer Assisted Intervention–MICCAI 2021: 24th International Conference, Strasbourg, France, September 27–October 1, 2021, Proceedings, Part IV 24. Springer, 2021, pp. 647–656.
[18] M. Haiderbhai and L. A. Kahrs, “Simulating surgical robot cutting of thin deformable materials using a rope grid structure,” IEEE Transactions on Medical Robotics and Bionics, vol. 6, no. 4, pp. 1401–1404, 2024.
[19] P. Yu, Z. Zhao, R. Wang, and J. Pan, “Real-time soft body dissection simulation with parallelized graph-based shape matching on gpu,” Computer Methods and Programs in Biomedicine, vol. 250, p. 108171, 2024.
[20] I. Berndt, R. Torchelsen, and A. Maciel, “Efficient surgical cutting with position-based dynamics,” IEEE computer graphics and applications, vol. 37, no. 3, pp. 24–31, 2017.
[21] W. Wu and P. A. Heng, “An improved scheme of an interactive finite element model for 3d soft-tissue cutting and deformation,” The Visual Computer, vol. 21, pp. 707–716, 2005.
[22] P. M. Scheikl, B. Gyenes, R. Younis, C. Haas, G. Neumann, M. Wagner, and F. Mathis-Ullrich, “Lapgym-an open source framework for reinforcement learning in robot-assisted laparoscopic surgery,” Journal of Machine Learning Research, vol. 24, no. 368, pp. 1–42, 2023.
[23] P. Schegg, E. Ménager, E. Khairallah, D. Marchal, J. Dequidt, P. Preux, and C. Duriez, “Sofagym: An open platform for reinforcement learning based on soft robot simulations,” Soft Robotics, vol. 10, no. 2, pp. 410–430, 2023.
[24] Z. Xu, Z. Xian, X. Lin, C. Chi, Z. Huang, C. Gan, and S. Song, "Roboninja: Learning an adaptive cutting policy for multi-material objects," arXiv preprint arXiv:2302.11553, 2023.
[25] C. C. Beltran-Hernandez, N. Erbetti, and M. Hamaya, “Sliceit!–a dual simulator framework for learning robot food slicing,” arXiv preprint arXiv:2404.02569, 2024.
[26] E. Heiden, M. Macklin, Y. Narang, D. Fox, A. Garg, and F. Ramos, "Disect: A differentiable simulation engine for autonomous robotic cutting," arXiv preprint arXiv:2105.12244, 2021.
[27] L. Han, H. Wang, Z. Liu, W. Chen, and X. Zhang, “Vision-based cutting control of deformable objects with surface tracking,” IEEE/ASME Transactions on Mechatronics, vol. 26, no. 4, pp. 2016–2026, 2021.
[28] N. D. Nguyen, T. Nguyen, S. Nahavandi, A. Bhatti, and G. Guest, "Manipulating soft tissues by deep reinforcement learning for autonomous robotic surgery," in 2019 IEEE International Systems Conference (SysCon). IEEE, 2019, pp. 1–7.
[29] A. A. Shahkoo and A. A. Abin, “Autonomous tissue manipulation via surgical robot using deep reinforcement learning and evolutionary algorithm,” IEEE Transactions on Medical Robotics and Bionics, vol. 5, no. 1, pp. 30–41, 2023.
[30] H. Saeidi, J. Ge, M. Kam, J. Opfermann, S. Leonard, A. Joshi, and A. Krieger, “Supervised autonomous electrosurgery via biocompatible near-infrared tissue tracking techniques,” IEEE transactions on medical robotics and bionics, vol. 1, no. 4, pp. 228–236, 2019.
[31] J. Ge, H. Saeidi, M. Kam, J. Opfermann, and A. Krieger, “Supervised autonomous electrosurgery for soft tissue resection,” in 2021 IEEE 21st International Conference on Bioinformatics and Bioengineering (BIBE). IEEE, 2021, pp. 1–7.
[32] X. Liang, C.-P. Wang, N. U. Shinde, F. Liu, F. Richter, and M. Yip, "Medic: Autonomous surgical robotic assistance to maximizing exposure for dissection and cautery," arXiv preprint arXiv:2409.14287, 2024.
[33] K.-H. Oh, L. Borgioli, M. Zefran, L. Chen, and P. C. Giulianotti, "A framework for automated dissection along tissue boundary," arXiv preprint arXiv:2310.09669, 2023.
[34] Z. Karimi, S.-H. Ho, B. Thach, A. Kuntz, and D. S. Brown, “Reward learning from suboptimal demonstrations with applications in surgical electrocautery,” arXiv preprint arXiv:2404.07185, 2024.
[35] Y. Zhang, F. Liu, X. Liang, and M. Yip, “Achieving autonomous cloth manipulation with optimal control via differentiable physics-aware regularization and safety constraints,” arXiv preprint arXiv:2309.11655, 2023.
[36] X. Liang, F. Liu, Y. Zhang, Y. Li, S. Lin, and M. Yip, “Real-to-sim deformable object manipulation: Optimizing physics models with residual mappings for robotic surgery,” 2023.
[37] A. Myronenko and X. Song, “Point set registration: Coherent point drift,” IEEE Transactions on Pattern Analysis and Machine Intelligence, vol. 32, no. 12, pp. 2262–2275, 2010.
[38] P. Kazanzides, Z. Chen, A. Deguet, G. S. Fischer, R. H. Taylor, and S. P. DiMaio, “An open-source research kit for the da vinci® surgical system,” in 2014 IEEE International Conference on Robotics and Automation (ICRA), 2014, pp. 6434–6439.
[39] Z. Teed and J. Deng, “Raft: Recurrent all-pairs field transforms for optical flow,” in Computer Vision–ECCV 2020: 16th European Conference, Glasgow, UK, August 23–28, 2020, Proceedings, Part II 16. Springer, 2020, pp. 402–419.
[40] Z. Liang, Z.-Y. Chiu, F. Richter, and M. C. Yip, “Differentiable rendering-based pose estimation for surgical robotic instruments,” arXiv preprint arXiv:2503.05953, 2025.
[41] A. Kirillov, E. Mintun, N. Ravi, H. Mao, C. Rolland, L. Gustafson, T. Xiao, S. Whitehead, A. C. Berg, W.-Y. Lo, P. Dollár, and R. Girshick, "Segment anything," arXiv:2304.02643, 2023.
[42] H. K. Cheng, S. W. Oh, B. Price, J.-Y. Lee, and A. Schwing, “Putting the object back into video object segmentation,” in Proceedings of the IEEE/CVF Conference on Computer Vision and Pattern Recognition, 2024, pp. 3151–3161.
[43] L. Lipson, Z. Teed, and J. Deng, “Raft-stereo: Multilevel recurrent field transforms for stereo matching,” in International Conference on 3D Vision (3DV), 2021.
[44] X. Liang, Y. Zhang, F. Liu, F. Richter, and M. Yip, “Autopeel: Adhesion-aware safe peeling trajectory optimization for robotic wound care,” arXiv preprint arXiv:2409.14282, 2024.
[45] N. Karaev, I. Rocco, B. Graham, N. Neverova, A. Vedaldi, and C. Rupprecht, “Cotracker: It is better to track together,” in European Conference on Computer Vision. Springer, 2024, pp. 18–35.
[46] M. Macklin, “Warp: A high-performance python framework for gpu simulation and graphics,” https://github.com/nvidia/warp, March 2022, nVIDIA GPU Technology Conference (GTC).