Abstract

In clinical practice, agreement among independent experts is treated as evidence of reliability, and multi-round consensus has become a core mechanism of agentic medical question-answering systems. When such a system must decide whether to trust its own answer, the prevailing signal is again agreement, now among the sampled answers. But agreement is a fragile proxy for correctness. A system can be unanimously wrong, returning the same incorrect answer on every sample, and on these questions agreement-based signals carry no information. The cause is that these signals read only the final state of the consensus and discard how it was reached. Agreement that was reached by resolving disagreement with evidence looks identical, at the end, to agreement that was present from the first sample because every sample shares one misconception. ProbeGuard is a certified abstention framework that bases the abstention decision on how the consensus formed. All of its components are computed from the system's execution log. Process features trace agreement trajectories, minority persistence, and retrieval saturation. For unanimous votes, rationale semantic entropy checks whether the reasons behind the vote cohere, and an active probe retrieves counter-evidence and measures whether the consensus survives. A stratified Learn-then-Test calibration then converts these scores into a distribution-free bound on selective risk. This lets the system separate unanimous votes that are backed by knowledge from those that are not, and answer only where its error rate is provably controlled. We evaluate ProbeGuard on three medical QA benchmarks and a hard-frontier reference, with a published multi-round agentic RAG substrate, against six abstention baselines. On MedQA, 13.4% of unanimous votes are wrong, and no agreement-based signal can flag them. Process signals raise the discrimination of correct from incorrect consensus from chance to 0.696 AUROC. The certified rule answers six in ten unanimous-layer questions at an observed selective risk of 9.0%, and nine in ten once in-domain calibration data accumulate. Code: https://github.com/wangxiaoyang0412/probeguard.

1 Introduction

Language models now encode substantial clinical knowledge [Singhal et al., 2023] and are moving into clinical question answering, where their answers increasingly inform triage, guideline lookup, and decision support. In these settings the failure that matters most is a confidently wrong answer. In a randomized trial, physicians exposed to erroneous LLM suggestions lost 14 percentage points of diagnostic accuracy, despite prior AI-literacy training and voluntary consultation [Qazi et al., 2026]; an answer delivered without any signal of doubt propagates directly into downstream decisions. The model itself cannot be trusted to raise that signal: frontier models almost never abstain when they should, and reasoning-oriented training makes abstention worse [Kirichenko et al., 2025]. A deployed system therefore needs reliable abstention, so that the questions it cannot answer are routed to a clinician [Machcha et al., 2026, Li et al., 2024b].

Preprint.

Figure

(a) Snapshot-based abstention

(b) ProbeGuard (Ours)

Figure 1: Two unanimous consensuses are indistinguishable to snapshot-based abstention (a), yet one is knowledge-backed and one is inherited from a shared misconception. ProbeGuard (b) checks whether the rationales behind a unanimous vote support one another and stress-tests the consensus with retrieved counter-evidence, answering only where selective risk is certifiably bounded.

The dominant abstention signals estimate confidence from a single round of samples: the model's verbalized certainty [Kadavath et al., 2022, Tian et al., 2023, Xiong et al., 2024b], or the agreement among independently sampled answers [Wang et al., 2023, Manakul et al., 2023, Kuhn et al., 2023]. Agreement scores have even been calibrated into conformal abstention rules directly [Yadkori et al., 2024]. Moving these signals to a modern multi-round consensus system [Wu et al., 2026] exposes their limits. Agreement can be inherited from a shared training-data error, in which case a model gives the same wrong answer eight times. Multi-round systems stop deliberating as soon as agreement is reached, so the terminal vote is 1 for every converged question. And on the questions where the system is unanimously wrong, no vote-based signal can raise an alarm. On our substrate, 59% of MedQA questions reach first-round unanimity, and 13.4% of those unanimous votes are wrong; on expert-level questions the rate rises to 79.0% (Figure 1).

These signals discard the formation process. Consider a panel of physicians who end up agreeing. All of them may have known the answer from the start, or all of them may share one misconception. A forced vote can also produce agreement, and so can a discussion in which they disagreed until one of them found the evidence that settled the question. The final tally is identical in each case, and the differences lie only in the record of the discussion. Multi-round consensus systems write this record to their execution logs, including which candidates disagreed, for how many rounds, which documents were retrieved, and whether the vote changed afterward. Yet prior work discards the trajectory once the answer is produced [Wu et al., 2026, Manczak et al., 2025]. When the vote is unanimous from the start, the trajectory is trivial and the check moves one level down, to the rationales. The reasons behind the vote can be checked for coherence, which extends semantic entropy [Farquhar et al., 2024] from answers to rationales, and the consensus can be tested directly by supplying opposing evidence.

Present work. We introduce ProbeGuard, which turns consensus formation into a certified abstention decision. Process features computed from the execution log trace how the vote evolved; for unanimous votes, rationale semantic entropy and an active counter-evidence probe read the evidence behind the vote; and Learn-then-Test calibration [Angelopoulos et al., 2022, 2024] within process strata yields a selective-risk bound that holds without distributional assumptions, where existing medical abstention methods provide heuristic scores [Dang et al., 2025, Shankar et al., 2025]. Every multi-round system already writes this log, and because the scores are training-free, the entire calibration set can be spent on threshold selection, and the thresholds it returns carry a guarantee a deployment can act on.

We make four contributions. (1) To our knowledge, we give the first abstention decision derived from how multi-round consensus forms, with a distribution-free selective-risk guarantee, in place of snapshot-based confidence assessment. (2) We instrument the execution log with trajectory features at zero additional inference cost, extend semantic entropy from answers to the concluding claims of rationales, and introduce an active counter-evidence probe whose keep rate measures whether a unanimous vote survives opposing evidence. (3) On questions where all N=8 candidates agree

Table 1: Comparison of abstention approaches for medical QA. External resources, scoring signals, and risk guarantees are reported for each method.

MethodExternal resourceAbstention scoreRisk guarantee
KnowGuardmedical knowledge graphevidence sufficiency✕
Energy-based scoringseparately trained scorerenergy✕
Conformal abstentionnoneanswer agreementglobal
ProbeGuard (ours)noneconsensus formationper-stratum

immediately, every vote-based signal is constant, yet 100 of 746 such votes on MedQA are wrong. We measure this failure mode across four benchmarks and three backbones. (4) The process score separates correct from incorrect consensus at 0.696 AUROC on MedQA, where terminal agreement scores 0.512, and at 0.704 on MMLU-Pro medicine. Wrong consensus flips under counter-evidence at 14.0–26.5%, against 3.3–5.5% for correct consensus. Stratified Learn-then-Test calibration answers 0.553 of the unanimous layer at 9.0% observed risk ( α=0.15\alpha=0.15 , 50 splits).