arXiv:2610.07824cs.LGOct 2026

Manuscript Offprint

arXiv:2610.07824

CANDLE: Cortical Null-Space Decomposition for Noninvasive Brain Source Imaging

Shuntaro Suzuki, Yuiga Wada, Komei Sugiura

ABSTRACT

Electrophysiological source imaging (ESI) aims to estimate cortical source activity from noninvasive electrophysiological measurements such as electroencephalogram (EEG). However, ESI is fundamentally ill-posed because source activity is substantially higher-dimensional than sensor observations, resulting in non-unique solutions. Recent learning-based approaches address this ambiguity by learning data-driven source priors, yet they often struggle to generalize across subject-specific cortical geometries. To address this, we propose CANDLE, a learning-based ESI model that estimates source activity on subject-specific cortical geometries. CANDLE learns a prior over the null space induced by the source-to-sensor mapping derived from T1-weighted MRI, restricting learning to unobservable source components while preserving geometric constraints. To train CANDLE, we develop a whole-brain simulator spanning over 1,100 subject-specific cortical geometries with source configurations derived from over 26,000 statistical brain maps. Trained exclusively on simulated data, CANDLE outperformed prior ESI methods on simulated source activity estimation and generalized to two empirical tasks: (i) intracranial stimulation localization from simultaneously recorded scalp EEG and (ii) epileptogenic zone estimation from presurgical interictal EEG. Our project page is available at https://candle-esi.pages.dev.

1 INTRODUCTION

Monitoring whole-brain neural activity at both high temporal and spatial resolution is central to a broad range of applications, from the diagnosis of neurological disorders (Cao et al., 2022) to the development of brain-computer interfaces (BCIs) (Suzuki et al., 2026; Jayalath & Jones, 2026). This motivates the development of neuroimaging techniques capable of faithfully capturing such neural dynamics. Functional magnetic resonance imaging (fMRI) provides high spatial but limited temporal resolution and measures neural activity indirectly, whereas invasive electrophysiological techniques such as electrocorticography (ECoG) and stereoelectroencephalography (SEEG) provide high-fidelity recordings at fine temporal scales but require neurosurgical implantation and offer spatially restricted coverage (He & Liu, 2008; Momi et al., 2025). Noninvasive electrophysiological modalities such as electroencephalography (EEG) and magnetoencephalography (MEG) therefore constitute a promising avenue for whole-brain monitoring at high temporal resolution (Feng et al., 2025). Nevertheless, EEG/MEG exhibit limited spatial resolution at the sensor level, owing to relatively sparse sensor sampling and substantial spatial mixing of neural signals (i.e., volume conduction and field spread) (Wens, 2023).

Electrophysiological source imaging (ESI), which seeks to recover cortical source activity from EEG/MEG signals, has been extensively studied as a means of overcoming this limitation (Sun et al., 2022; Wang et al., 2026). By reconstructing neural activity in cortical source space, ESI holds the promise of whole-brain monitoring with both high temporal and spatial resolution. The utility of ESI has further been suggested for applications such as presurgical localization of epileptogenic zones (Corona et al., 2023) and improved decoding in BCIs (Gideoni et al., 2024).

ESI, however, is a fundamentally ill-posed problem: the source activity to be estimated is substantially higher-dimensional than the observed EEG/MEG, and the solution is consequently non-unique. Conventional ESI methods (Van Veen et al., 1997; Dale et al., 2000) therefore typically require careful tuning of regularization schemes and source-space constraints for individual applications. This reliance on manual constraints not only limits the broad applicability of ESI but also

Figure

Figure 1: Overview of CANDLE. Given EEG X and the corresponding T1-weighted MRI G, a subject-specific lead-field matrix L is derived as an anatomical constraint. The denoising model fθf_{\theta} outputs denoised X, from which the range-space component is analytically recovered, while gγg_{\gamma} estimates the unobservable null-space component. Their combination yields the source estimate Y^\hat{Y}.

undermines reproducibility. To alleviate these limitations, learning-based ESI models (Hecker et al., 2021; Sun et al., 2022) have recently been proposed to learn data-driven priors over source activity.

Despite this progress, most learning-based ESI models are trained in a subject-aggregated common cortical space, such as fsaverage (Fischl et al., 1999), and therefore cannot explicitly account for inter-individual differences in cortical geometry. Indeed, Sun et al. (2023) reported that applying learning-based ESI models to a particular subject requires subject-specific post-training.

To address this limitation, we propose CANDLE 1^{1}, a learning-based ESI model that directly estimates source activity on subject-specific cortical geometries from EEG. CANDLE learns the null-space component (Schwab et al., 2019) of source activity induced by a T1-derived source-to-sensor mapping. This allows the model to capture a prior over source activity while preserving subject-specific geometric constraints. Furthermore, we introduce a whole-brain simulator tailored to training CANDLE. Because ground-truth source activity is unobservable in real recordings, learning-based ESI models are typically trained on data synthesized by whole-brain simulators (Schirner et al., 2022; Ziaemehr et al., 2025), and evaluated through sim-to-real validation on downstream tasks. Existing simulators, however, are not designed to jointly capture the anatomical variability and realistic source configurations required for training CANDLE. Our simulator addresses this gap by generating neurobiologically grounded source activity across diverse subject-specific cortical geometries.

Our contributions are summarized as follows:

• We propose CANDLE, a learning-based ESI model that incorporates subject-specific cortical geometry derived from each subject's T1-weighted MRI. CANDLE learns the null-space component of cortical source activity, thereby imposing a data-driven prior on the unobservable source subspace while preserving subject-specific geometric constraints.

• We develop a whole-brain simulator for training CANDLE that synthesizes realistic source activity across subject-specific cortical geometries from over 1,100 individuals and defines neurobiologically grounded source regions by clustering over 26,000 statistical brain maps.

• Without subject-specific tuning, CANDLE outperformed prior ESI methods on simulated source activity estimation and generalized to two relevant empirical tasks: (i) intracranial stimulation localization from simultaneously recorded scalp EEG and (ii) epileptogenic zone estimation from presurgical interictal EEG.

References (60)