arXiv:2610.07885cs.LGOct 2026

Manuscript Offprint

arXiv:2610.07885

Label-Efficient Deep Learning for ECG Delineation: A Multi-Dataset Benchmark against Widely Used Delineation Tools

Jeonghwa Lim, Minje Park, Yeongyeon Na, Yujin Eom, Soyeon Lim, Young Ho Lee, Yu Jeong Kim, Sunghoon Joo, Ki Hong Lee

Jeonghwa Lim*, Minje Park*, Yeongyeon Na, Yujin Eom, Soyeon Lim, Young Ho Lee, Yu Jeong Kim, Sunghoon Joo†, and Ki Hong Lee‡

Abstract—Electrocardiogram (ECG) delineation, the identification of waveform boundaries, is a foundational step that translates raw ECG signals into clinically interpretable measurements. Deep learning has advanced this task but remains dependent on costly expert annotations. Label-efficient strategies such as self-supervised pretraining and semi-supervised learning are expected to ease this burden, yet it remains unclear whether they yield reliable delineation and whether the deep models they produce outperform the delineation tools used in practice. We address this in two stages. First, comparing self-supervised objectives with supervised or semi-supervised fine-tuning across one internal and four external datasets, we find that pretraining helps but the objective matters, and that the value of semi-supervised fine-tuning depends on the pretraining objective. Second, we benchmark the selected deep learning model against widely used open-source (NeuroKit2, Prominence, ECGdeli) and commercial (CalECG) tools using three complementary metrics. The model ranks best on every metric and dataset, outperforming the strongest tool by a clear margin on the rhythm-diverse set (mIoU 71.3 vs. 54.8%; averaged point-wise sensitivity 92.6 vs. 76.4%), and degrades the least from sinus to arrhythmia. A rhythm-stratified and point-wise analysis further characterizes the distinctive behavior of each tool, yielding practical guidance for tool selection. These results provide systematic, multi-dataset evidence that self-supervised pretraining is effective for ECG delineation and

enables a label-efficiently trained deep learning model to outperform widely used delineation tools by leveraging abundant unlabeled data. This supports adopting such models in diverse, real-world clinical settings.

Index Terms—Electrocardiography, Semantic segmentation, Electrocardiogram delineation, Label-efficient learning, Self-supervised learning, Semisupervised learning, Benchmarking

I. INTRODUCTION

A N Electrocardiogram (ECG) delineation, the segmentation of the ECG signal into its component P wave, QRS complex, and T wave, forms the basis for deriving clinically essential measurements such as the PR interval, QRS duration, and QT interval [1]. These intervals are fundamental to the diagnosis and monitoring of a wide range of cardiac conditions, including conduction abnormalities, arrhythmias, and other electrophysiologic disorders such as QT prolongation [2]. Accordingly, accurate and reliable ECG delineation is essential, as it directly affects the quality of downstream clinical decision-making [3]. Yet achieving robust, generalizable ECG delineation remains challenging, owing to substantial morphological variability and signal-quality degradation across patients and recording conditions [4], [5].

Automated delineation has followed two broad approaches: rule-based signal processing and deep learning. Rule-based methods are interpretable, lightweight, and widely deployed, but their accuracy tends to degrade on morphologically atypical beats and under residual noise, such as baseline wander and muscle artifacts, that distorts the waveform features on which they rely [4], [5]. Recently, deep learning has been increasingly applied to delineation, learning waveform morphology directly from data and achieving improved accuracy [6]–[8]. The key limitation of deep learning, however, is a reliance on large volumes of expert-annotated data: precise delineation labels are costly and time-consuming to obtain, which constrains the practical scalability of fully supervised training.

This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: RS-2023-00265466).

  • Both authors contributed equally to this research.

J. Lim, M. Park, and Y. Na are with VUNO Inc., Seoul, South Korea (e-mail: {jeonghwa.lim, minje.park, yeongyeon}@vuno.co).

Y. Eom is with the Department of AI Mobility Engineering, Ajou University, Suwon, South Korea (e-mail: eomyj2@ajou.ac.kr).

S. Lim is with C&Thoth Co., Ltd., Seoul, South Korea (e-mail: sylim@cnthoth.com).

Y. H. Lee is with the Department of Biomedical Sciences, Chonnam National University Graduate School, and the Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, South Korea (e-mail: onuri205dev@gmail.com).

Y, J, Kim is with the Department of Cardiovascular Medicine, Chonnam National University Hospital, Gwangju, South Korea (e-mail: rmfls925@gmail.com).

†^{\dagger} Corresponding author. S. Joo is with VUNO Inc., Seoul, South Korea (e-mail: sunghoon.joo@vuno.co).

Label-efficient deep learning [9] can be a promising approach to mitigate the annotation bottleneck. Semi-supervised learning combines a limited labeled set with abundant unlabeled data, improving over supervised training on the labeled subset alone [10]. Self-supervised pretraining, which learns transferable representations from large-scale unlabeled data

‡^{\ddagger} Corresponding author. K. H. Lee is with the Department of Cardiovascular Medicine, Chonnam National University Hospital, and the Department of Internal Medicine, Chonnam National University Medical School, Gwangju, South Korea (e-mail: drgood2@naver.com).

IEEE TRANSACTIONS AND JOURNALS TEMPLATE

Stage 1. Label-Efficient Deep Learning

Figure

Stage 2. Benchmarking Against Rule-Based Tools

Figure

Fig. 1. Study overview. Stage 1 pretrains an encoder on unlabeled ECG data with self-supervised learning (e.g., Masked Autoencoder) and fine-tunes it with a segmentation decoder (e.g., FCN) under supervised and semi-supervised learning (e.g., Mean Teacher). Stage 2 benchmarks the resulting model against existing delineation tools on multiple datasets using three complementary metrics: mIoU, measurement error on the PR, QRS, and QT intervals, and fiducial point localization accuracy.

before task-specific fine-tuning, has driven progress across various domains [11], [12], including ECG tasks such as arrhythmia detection and disease screening [13]–[15]. The effectiveness of label-efficient learning for ECG delineation, however, remains unexamined on two fronts. First, ECG delineation is a dense prediction task at the level of individual time points, unlike the record-level classification tasks where pretraining has proven effective [16]. It is therefore unclear whether self-supervised pretraining helps at all, how different pretraining objectives compare, and how the choice of objective interacts with supervised versus semi-supervised fine-tuning. Second, setting aside how these models are trained, label-efficient learning approaches have, to our knowledge, never been directly benchmarked against the open-source and commercial tools currently used in research and clinical practice.

We address these questions in two stages, illustrated in Fig. 1. In the first stage, we compare several pretraining objectives, each followed by supervised or semi-supervised fine-tuning, to assess the effect of self-supervised pretraining and the fine-tuning strategy on delineation performance. In the second stage, we benchmark the model selected in the first stage against established open-source and commercial tools.

Our contributions are summarized as follows:

• We provide systematic, multi-dataset evidence that self-supervised pretraining benefits ECG delineation.

• We present the first benchmark of label-efficiently trained deep learning models against multiple open-source libraries as well as a commercial package, with rhythm-stratified analysis across diverse external datasets.

• We characterize the distinctive behavior of each tool across datasets, and show that the deep learning model achieves the best overall performance while remaining robust under arrhythmia.

References (50)