Manuscript Offprint

arXiv:2610.08109

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor

Anam Hashmi 1,2^{1,2} ID^{ID}, Mayug Maniparambil 2^{2} ID^{ID}, Julia Dietlmeier 2^{2} ID^{ID}, Kathleen M. Curran 3^{3} ID^{ID}, and Noel E. O'Connor 2,4^{2,4} ID^{ID}

1^{1} Research Ireland Centre for Research Training in Machine Learning, Ireland

2^{2} Dublin City University, Ireland

anam.hashmi2@mail.dcu.ie, mayug.maniparambil2@mail.dcu.ie,

Julia.Dietlmeier@dcu.ie, Noel.OConnor@dcu.ie

3^{3} University College Dublin, Ireland

kathleen.curran@ucd.ie

4^{4} Rinn Artificial Intelligence, Ireland

Abstract. Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction. Code is publicly available at: github.com/Hashmi360/BeyondScratch-CMR.

Keywords: Cardiac MRI Reconstruction · Data-Efficient Learning · Foundation Models · Low-Rank Adaptation

1 Introduction

Cardiovascular disease remains the leading cause of mortality worldwide, motivating the need for accurate, non-invasive imaging tools for early diagnosis and

A. Hashmi et al.

clinical decision-making [14, 42]. Cardiac magnetic resonance imaging (CMR) is widely considered a reference standard for assessing cardiac anatomy, function, and pathology, offering high-resolution soft-tissue contrast without ionizing radiation [9, 28, 42]. However, MRI acquisition is intrinsically slow because measurements are collected sequentially in k-space [43]. Long scan times increase patient discomfort, limit scanner throughput, and make acquisitions more vulnerable to motion artifacts, which is particularly challenging in cardiac imaging [43]. Accelerated MRI addresses this limitation by undersampling k-space to reduce acquisition time [43, 45], but reconstructing diagnostic-quality images from incomplete measurements is a severely ill-posed inverse problem, requiring strong priors to suppress aliasing artifacts while preserving anatomical detail [10, 14, 26].

Classical reconstruction methods incorporate handcrafted priors, such as sparsity and compressed sensing, to regularize the recovery of images from undersampled data [6,16,27]. In contrast, deep learning methods learn reconstruction priors directly from data and have substantially improved both reconstruction quality and computational efficiency in accelerated MRI [10,16,26,45]. Existing approaches operate in the image domain, k-space domain, or hybrid image-k-space formulations [10,12,19,26,35,43,46]. Among these, image-domain models remain attractive due to their efficiency, simplicity, and strong empirical performance [16,26]. CNN- and transformer-based architectures, in particular, have shown strong capacity to learn anatomical image priors and recover high-fidelity reconstructions from undersampled acquisitions [10,16,26].

Despite these advances, deep learning-based MRI reconstruction models remain highly data-dependent and often degrade under domain shift caused by changes in scanner hardware, acquisition protocols, anatomy, or pathology [23, 26]. This limits their reliability in practical clinical deployment, where large, standardized training datasets are difficult to obtain. These challenges motivate a shift from increasingly specialized reconstruction architectures toward more transferable learning paradigms [18, 23].

Given the success of transfer learning in computer vision, a central question arises for MRI reconstruction: can representations learned from large-scale visual pretraining transfer effectively to this domain, or is task-specific training still necessary? Although vision foundation models have shown strong transferability across diverse vision tasks, their role in MRI reconstruction remains underexplored. Recent studies have incorporated foundation models into reconstruction pipelines with promising results [13,14]; however, additional reconstruction modules make it difficult to isolate the contribution of the pre-trained representations themselves. Moreover, comparisons with architecturally matched transformers trained from scratch are largely missing, leaving unclear whether foundation models provide inherently stronger priors or whether similar performance can be achieved through MRI-specific training alone. This question also extends to adaptation: while parameter-efficient fine-tuning methods such as LoRA [44,48] are effective in downstream vision tasks, their value for MRI reconstruction, particularly under low-data and cross-dataset generalization, remains insufficiently studied.

To address these questions, we study the role of pretrained visual representations in cardiac MRI reconstruction. We incorporate three vision foundation models, CLIP [32], BiomedCLIP [47], and DINOv2 [30]-into the encoder of a transformer-based reconstruction framework, UNETR [15]. This enables a systematic empirical comparison between three representation learning paradigms: (i) training transformer encoders from scratch, (ii) using frozen pretrained representations, and (iii) adapting pretrained representations via parameter-efficient fine-tuning. Through experiments spanning multiple acceleration factors, low-data regimes, and cross-dataset generalization settings, we evaluate when and how pretrained representations benefit MRI reconstruction.

Our findings show that pretrained foundation model encoders consistently outperform transformers trained from scratch, demonstrating the value of transferable visual priors for reconstruction. While parameter-efficient adaptation can yield additional improvements, its benefits depend on the target dataset and amount of available supervision. Notably, pretraining provides the largest gains in low-data settings, whereas adaptation becomes increasingly beneficial as more MRI training data become available. Together, these results offer new insights into representation transfer for MRI reconstruction and challenge the common practice of learning transformer representations entirely from scratch.

The main contributions of this work are as follows:

– We present, to the best of our knowledge, the first systematic study of representation transfer for cardiac MRI reconstruction, providing a systematic empirical comparison of scratch-trained transformers, frozen vision foundation models, and parameter-efficiently adapted foundation models within a unified reconstruction framework. Our findings shift the focus from learning reconstruction representations from scratch toward adapting transferable visual priors acquired through large-scale pretraining.

– We investigate parameter-efficient adaptation for MRI reconstruction through LoRA, revealing how the relative benefits of pretraining and adaptation evolve across different supervision levels and training-data regimes.

– We show that pretrained vision foundation models consistently yield superior reconstruction quality and stronger cross-dataset generalization than transformers trained from scratch, highlighting the value of transferable visual priors for robust accelerated cardiac MRI reconstruction.

References (48)