arXiv:2608.25965cs.CVAug 2026

Manuscript Offprint

arXiv:2608.25965

Less Contouring, More Accuracy: Lesion-Guided ROI Deep Learning for Ovarian Ultrasound Classification

Mehran Ahmad, Ali Abbasian Ardakani, Afshin Mohammadi, Alisa Mohebbi, Gernot Kronreif, Sepideh Hatamikia

Abstract

Objective: The classification and malignancy risk assessment of ovarian lesions using transvaginal ultrasound are challenging because of overlapping imaging features and operator-dependent interpretation. This study compared deep learning (DL) and machine learning (ML)-based radiomics strategies to identify an approach that maintains high diagnostic performance while minimizing annotation burden.

Methods: Two retrospective ovarian ultrasound datasets were used: the Multi-Modality Ovarian Tumor Ultrasound (MMOTU) dataset for eight-class classification and the Ovarian Ultrasound Dataset (OUD) for binary classification. Four strategies were evaluated under a unified experimental protocol: global image-based DL, lesion-guided region-of-interest (ROI)-based DL, lesion contour-based DL, and lesion contour-based radiomics with conventional ML classifiers. Four DL architectures, MaxViT-Tiny, Swin Transformer, EfficientNet-B7, and ResNet18, were evaluated. For the radiomics strategy, quantitative features were extracted from mask-isolated lesion regions and classified using a radial basis function support vector machine (SVM), k-nearest neighbors (KNN), and an artificial neural network (ANN). For the lower-sample OUD dataset, ANOVA-based feature selection was applied to reduce the initial 215-dimensional feature space before classification. Bootstrap resampling was used for robust performance evaluation.

Results: The analysis included 507 patient cases across the MMOTU and OUD datasets. The lesion-guided ROI-based DL strategy achieved the strongest overall performance. MaxViT-Tiny achieved 93.10% accuracy with an AUC of 0.99 on MMOTU and 97.56% accuracy with an AUC of 0.99 on OUD. The lesion contour-based approach achieved comparable performance, with 91.81% accuracy and an AUC of 0.99 on MMOTU and 95.12% accuracy and an AUC of 0.99 on OUD, but required substantially greater annotation effort because of pixel-level contour delineation. Radiomics-based models showed competitive performance in the binary classification setting but were less effective for multiclass classification. Conclusion: Lesion-guided ROI-based DL provided the best balance between diagnostic performance and annotation burden for ovarian ultrasound classification. This strategy may offer a more practical and scalable approach for AI-assisted ovarian lesion assessment and clinical workflow integration. Prospective multicentre validation is required to confirm its broader generalizability and clinical utility.

Keywords: Ovarian ultrasound, Deep learning, Machine learning, Lesion-guided ROI, Ovarian ultrasound classification, Radiomics, Artificial intelligence

1 Introduction

Transvaginal sonography (TVS) serves as the primary imaging modality for the evaluation of ovarian masses, providing real-time, high-resolution visualization of lesion morphology and internal composition [1–3]. In clinical practice, TVS enables risk stratification through standardized systems such as the International Ovarian Tumor Analysis (IOTA) models and the Ovarian-Adnexal Reporting and Data System (ORADS), thereby supporting clinical management decisions [4, 5]. However, ultrasound interpretation remains highly operator-dependent, with substantial inter-observer variability arising from overlapping sonographic features between benign and malignant lesions and subtle distinctions among specific ovarian lesion etiologies [6, 7]. These limitations highlight the need for objective artificial intelligence (AI)-based adjunctive tools to improve diagnostic consistency and reduce subjectivity in radiological workflows.

Both DL and radiomics-based models applied to TVS have demonstrated considerable potential for assisting radiologists in ovarian lesion characterization and etiological classification. DL architectures can be integrated into clinical reporting workflows to provide rapid and objective probability estimates for malignancy and for specific diagnoses, such as serous cystadenoma, teratoma, or high-grade serous carcinoma. Such tools may help reduce inter-observer variability and support less experienced examiners in lesion triage, follow-up planning, and timely referral [8–13][8–13].

Radiomics-based approaches complement DL by providing quantitative and potentially interpretable imaging biomarkers derived from lesion texture, shape, and intensity characteristics. These features are typically extracted from segmented lesion regions and may be incorporated into existing O-RADS or IOTA-based workflows to refine risk stratification when visual characteristics overlap and to support etiological classification without requiring highly complex computational architectures [8,14–16][8, 14–16].

Recent studies have further demonstrated the potential of AI for ovarian ultrasound diagnosis in both binary and multiclass classification settings. For binary diagnosis, a deep convolutional neural network (DCNN) trained on pelvic ultrasound data achieved an area under the receiver operating characteristic curve (AUC) of 0.911 [17]. Feature-fusion and decision-fusion strategies applied to multimodal ultrasound achieved an AUC of 0.93 with a sensitivity of 92% [18]. An ensemble of ten pretrained convolutional neural networks (CNNs) achieved an accuracy of 92.15% and specificity of 92.92%, outperforming individual models [19]. A CNN combined with a denoising convolutional autoencoder, achieved 97.2% accuracy for normal-versus-tumor classification and 90.12% accuracy for malignancy discrimination [20]. DenseNet achieved a test accuracy of 97.5% for benign-versus-malignant classification [21], while a Swin Transformer demonstrated expert-level performance on TVS, achieving an AUC of 0.92 [22].

The field has subsequently progressed toward multiclass ovarian lesion classification, which is more challenging but potentially more clinically informative because it aims to distinguish specific ovarian conditions rather than only separate benign from malignant lesions. The MMOTU benchmark was introduced with baseline results in which EfficientNetV2-M achieved a top-1 accuracy of 80.60% [23]. EfficientOvaNet, a dual-branch EfficientNet-B3 framework combining lesion ROI and global image features, achieved an accuracy of 91.9% [24]. However, performance across multiclass studies remains variable. A fine-tuned YOLOv8x reached only 70.6% mAP50 for eight-class classification [25], while ResNet18 achieved an accuracy of 76.2% and an F1-score of 78.2% on the three-class (OUD) dataset, comprising normal ovary, dominant follicle (DF), and polycystic ovary (PCO) images [26]. Collectively, these studies indicate that DL can achieve high performance in binary diagnosis, whereas multiclass recognition remains more sensitive to dataset size, class composition, lesion heterogeneity, and model design.

Despite these promising findings, several important gaps remain that directly affect the practical development and implementation of AI-assisted ovarian ultrasound analysis. Most existing studies have not systematically compared global image analysis with clinically practical lesion-focused annotation strategies, such as a rapidly defined rectangular ROI around the lesion versus detailed pixel-level contour delineation. Furthermore, previous studies [18–26][18–26] remain limited to a single-center dataset, and the assessment of a unified framework on different data from different centers and across different ovarian lesion types has not been explored. Moreover, in a busy center, the extra time needed for detailed contouring limits how easily these AI tools can be developed and adopted into routine practice. In routine clinical practice, ovarian lesion diagnosis relies predominantly on visual interpretation of ultrasound.

images, as illustrated in Fig. 1, which may be subjective, operator-dependent, and time-consuming.

Overcoming Challenges in Ovarian Ultrasound Diagnosis: The Role of AI

The Diagnostic Challenges (Manual Analysis)

Proposed AI-Assisted Diagnostic Framework

Figure

Data Centre 1:

8 Class Tumor

Classification

Data Centre 2:

Binary classification

Input Image

AI Predication

95 % Confidence

Interval

AI-ASSISTED CLINICAL DECISION SUPPORT

Empowering Ovarian ultrasound Diagnosis

AI Predication

Specific Type

Chocolate Cyst

95% CI

AI Predication

Specific Type

PCO

95% CI

Clinical and Technical Challenges:

Subjective and operator-dependent interpretation

Inter-observer variability

Visual overlap among ovarian lesion types

Increased complexity in multiclass classification

High clinician workload

Time-consuming

AI-Powered Solution Benefits:

✓ Consistent, Objective Analysis & Improved Diagnostic Consistency

✓ Precise Multiclass Discrimination

✓ Rapid Binary Classification

✓ Decision Support for Doctors

✓ Reduced Error Rates

✓ Reduced Inter-Observer Variability

Fig. 1 Clinical challenges in visual ovarian ultrasound interpretation and the role of AI-assisted diagnosis.

Therefore, the aim of this study was to compare four ultrasound-based AI strategies for ovarian lesion classification across binary and multiclass settings using two publicly available datasets. We performed a head-to-head evaluation of global image-based DL, lesion-guided ROI-based DL, lesion contour-based DL, and lesion contour-based radiomics combined with conventional ML classifiers. In particular, we investigated whether the less annotation-intensive lesion-guided ROI strategy could achieve diagnostic performance comparable to detailed contour-based approaches while substantially reducing annotation burden. Robust statistical evaluation with confidence intervals was additionally performed to assess the reliability of the observed performance differences and to identify a practical strategy for both malignancy-related discrimination and classification of specific ovarian conditions.

References (26)