arXiv:2608.25970cs.CVAug 2026

Manuscript Offprint

arXiv:2608.25970

PANDA - Prototype-Anchored Alignment for Partially Unpaired Multimodal Learning, with Applications to Alzheimers MRI and TCGA Pathology

Sheethal Bhat, Mahfuzur Rahman Chowdhury, Paula Andrea Perez-Toro, Stephan Wunderlich, Rose Dawn Bharat, Siming Bayer, Andreas Maier

Abstract

Multimodal medical prediction frequently contends with incomplete pairing: auxiliary modalities with complementary signal are available for only a subset of subjects (or none) and cannot be assumed at deployment. We introduce PANDA (Prototype-Anchored Data Alignment), a two-stage framework that transfers auxiliary information to a primary-modality model without auxiliary inputs at inference. Two-stage training first derives class-specific auxiliary prototypes from the shared embedding, then aligns the primary encoder to these frozen prototypes. Because supervision is defined at the class-prototype level, PANDA accommodates arbitrary pairing rates, including zero subject overlap.

We evaluate PANDA on two applications. On a 1,021-subject multi-scanner ADNI cohort, we perform AD/CN classification with three auxiliary modalities at distinct pairing rates: tabular scores (44.8%), FDG-PET (18.7%), and external handwriting kinematics (0% overlap). Relative to the same-backbone

MRI-only baseline, PANDA improves AUC on both encoders, with a larger gain on the weaker one: on a transfer-pretrained MedicalNet backbone it attains AUC 0.868±0.0200.868 \pm 0.020 (+7.9 pp over the MRI-only baseline) and reduces 1.5 T CN false positives by 25.2 pp, while on a stronger, fully trainable Conv5-FC3 backbone it reaches a SOTA AUC of 0.893. On TCGA-Lung survival prediction from whole-slide images, using RNA-seq as auxiliary data, PANDA improves over WSI-only on 2-year OS (AUC +3.5 pp) and Cox PH (C-index +9.0 pts). It also outperforms full-fusion training, which underperforms WSI-only. PANDA requires no RNA at inference; wide confidence intervals on this smaller cohort keep the gains below conventional significance. Overall, PANDA provides a deployment-oriented mechanism for leveraging incomplete auxiliary modalities to improve primary-modality prediction.

Keywords: PANDA, Alzheimer's disease, MRI classification, unpaired multimodal learning, prototype alignment, cross-domain generalisation.

1 Introduction

Multimodal learning has become a standard approach in the general medical domain for prediction tasks [1–3]; however, most existing methods either assume that all modalities are jointly observed for every subject or rely on imputation and generative modelling to synthesize unobserved modalities. In practical settings, this assumption is rarely met. Auxiliary measurements that carry complementary signal, such as additional imaging, molecular assays, clinical scores, or behavioural markers, are typically available for only a subset of subjects in a large cohort. Moreover, their availability varies from one modality to the next, and they are frequently absent altogether at deployment. Discarding unpaired subjects or imputing missing modalities, the latter either by generative synthesis [4–6] or by reconstructing missing-modality features through Bayesian meta-learning [7], are the usual responses, but both waste the large pool of primary-modality data that is available, either shrinking the training set or injecting errors during imputation.

In this study, we investigate how a classifier constrained to a single primary modality at inference time can nonetheless leverage auxiliary modalities that are only partially paired with the primary modality during training, if paired at all. To this end, we shift supervision from per-subject correspondences to class-level geometry [8, 9]: auxiliary modalities are used solely to define fixed class prototypes, and the primary-modality encoder is aligned to these prototypes using all subjects, whether paired or unpaired. We subsequently interpret this alignment in information-theoretic terms (Section 4.3): it maximizes a lower bound on the mutual information between the primary encoder and the auxiliary modalities, thereby providing insight into why reduced pairing density need not degrade performance.

The approach is developed for medical imaging and evaluated in depth on structural MRI Alzheimer's disease (AD) classification, the primary application, enabling analyses of scanner robustness and disease-severity structure. Structural MRI is a natural primary modality for the AD study because it is non-invasive, broadly available, and sensitive to the hippocampal and cortical atrophy that characterises disease progression [10–12]. In the MRI/AD setting, real-world deployment additionally entails two interrelated challenges that are rarely addressed jointly. Transfer is further demonstrated on a structurally unrelated second application: whole-slide-image cancer survival prediction with a genomic auxiliary modality [13, 14].

A first challenge is scanner heterogeneity. Clinical neuroimaging datasets are acquired across sites using scanners that differ in field strength (1.5 T vs. 3 T), manufacturer, and acquisition protocol. Such variability induces systematic image-level domain shifts that can degrade classification performance [15–17]. Scanner heterogeneity is frequently circumvented rather than addressed: evaluations are often restricted to a single field strength or protocol-matched cohorts, and head-to-head cross-scanner validation is uncommon, leaving scanner robustness insufficiently characterized [17–19]. In the ADNI [10] cohort, an MRI-only baseline performs substantially worse at 1.5 T than at 3 T, with elevated false-positive rates among 1.5 T control subjects. Although domain adaptation and harmonization methods can partially mitigate these shifts, they typically require scanner labels during training or paired acquisitions that are often unavailable in retrospective multi-site studies.

A second challenge is incomplete multimodal coverage. Alongside MRI, clinical cohorts routinely collect auxiliary measurements, including neuropsychological scores (MMSE, CDR, FAQ), FDG-PET, and digital biomarkers, each of which provides complementary disease-relevant information. However, complete modality coverage is often unavailable at the subject level, and the paired subsets vary across modalities. In ADNI [10], cognitive scores and FDG-PET are each available for only a fraction of subjects. Moreover, some biomarker sources (e.g., digital handwriting kinematic assessments) are collected in entirely separate cohorts with no subject overlap. Standard multimodal fusion methods either require complete pairing at both training and inference [2, 3] or impute missing modalities [4, 5]; both are impractical at deployment and can introduce imputation-induced inductive bias.

These considerations motivate the hypothesis that, despite heterogeneity in raw feature space, the modalities encode a shared disease-discriminative structure, such that AD-versus-CN class separation is relatively modality-invariant. Consequently, the class geometry induced by an auxiliary modality can serve as a supervisory target for the primary-modality encoder. Aligning the primary encoder to this shared class-level geometry, rather than to per-subject correspondences, allows auxiliary modalities to shape the MRI representation for all subjects, whether paired or unpaired.

Specifically, this work introduces PANDA (Prototype-Anchored Data Alignment) 1^{1}, a two-stage framework illustrated in Fig. 2. In Stage 1, the MRI encoder and the auxiliary encoders are trained jointly on the available paired data to form a shared embedding, from which the auxiliary class prototypes are computed and then fixed (Fig. 2, top). In Stage 2, the MRI encoder is trained on all subjects to align with these fixed prototypes (middle). At inference time, the auxiliary encoders are discarded and each scan is classified from MRI alone (bottom). This formulation accommodates three qualitatively different pairing regimes within a single training procedure: subject-level

1^{1}A preliminary version of this work was presented in abstract form at BAIOSPHERE MEDICAL 2026 [20].

tabular pairing (44.8%), partial PET pairing (18.7%), and an external handwriting-kinematics prototype with no ADNI [10] overlap (0%).

On the ADNI [10] AD/CN cohort, the full model substantially outperforms an MRI-only baseline. When the same prototype alignment is applied on a stronger, fully-trainable encoder, it attains the highest overall performance on this cohort (AUC 0.893), surpassing the strongest unimodal baseline (see Section 6.4). A scanner-stratified analysis indicates that tabular alignment primarily reduces false-positive rates at 1.5 T, whereas PET alignment improves discrimination at 3 T. A pairing-rate ablation yields a notable result: the joint Tab+PET anchor does not degrade as pairing is reduced, indicating that full pairing is unnecessary. In addition, a zero-shot analysis on held-out MCI subjects shows that an MRI-only baseline does not reliably preserve the ordinal severity continuum, whereas the joint prototype-aligned model does. A simple linear severity head, trained only on graded CN/AD scores and never on MCI, further exposes an explicit monotone CN→AD severity axis without reducing AUC. Finally, cross-domain validation on TCGA-Lung (whole-slide images with RNA-seq) indicates that the mechanism is not neuroimaging-specific, with directionally consistent gains that the smaller cohort leaves below significance. Thus, the main contributions of this paper are:

  1. A framework for partially unpaired multimodal learning in medical imaging. PANDA is a two-stage, prototype-anchored alignment framework that enables a primary-modality classifier to leverage auxiliary modalities across pairing regimes (subject-level, partial, or external-cohort with zero overlap) within a single training procedure, while requiring only the primary modality at inference. We demonstrate the framework on two medical-imaging domains—brain MRI (AD/CN classification) and lung-pathology whole-slide imaging (survival)—and scope the claim to these settings rather than asserting generality beyond the domains evaluated here.

  2. Full pairing is not required. A pairing-rate ablation showing that sparse heterogeneous pairing matches full pairing (within seed noise) for the joint anchor, with a mechanistic explanation based on class-prototype separation, a finding with direct implications for how multimodal cohorts are best collected.

  3. Alzheimer's classification (primary application). A systematic scanner-stratified evaluation on ADNI [10] showing that different auxiliary modalities target different sources of scanner bias (clinical-score prototypes reduce 1.5 T false positives while PET prototypes improve 3 T discrimination), and a zero-shot analysis on held-out MCI subjects showing that the joint prototype-aligned model preserves a monotone CN→AD severity ordering that a single-modality baseline does not. A severity-head extension makes this axis explicit using graded CN/AD scores only; MCI never contributes a training gradient and binary AUC is unchanged.

  4. Cancer survival (second, cross-domain application). Validation on TCGA-Lung showing that the same prototype-transfer mechanism carries from 3D neuroimaging to gigapixel whole-slide imaging, exceeding full-fusion joint training despite using no RNA at inference.

References (48)