arXiv:2610.08346cs.CVOct 2026Cited by 1 paper on PaperVantage

Manuscript Offprint

arXiv:2610.08346

PolarScale: A Physics-Grounded Benchmark for Radiometrically Consistent RGB-to-Stokes Estimation

Beibei Lin, Tingting Chen, Xin Zhang, Wenhao Zhao, Dongjun Li, Zifeng Yuan

Abstract

Polarization imaging provides physical cues beyond intensity imaging but typically requires specialized hardware. Recent methods infer polarization from RGB-like inputs, yet predict only normalized Stokes components or relative descriptors, from which the radiometric scale needed for full Stokes reconstruction has been divided out. We introduce PolarScale, a benchmark that makes this scale an explicit prediction and evaluation target. Built on existing trichromatic full-Stokes measurements, PolarScale takes the per-scene normalized total-intensity image s0s_0 (a scene-referred linear image, not a consumer sRGB photograph) and asks models to predict normalized Stokes components, AoLP/DoLP/DoCP, and a per-scene scale. Because the scale is divided out of the input, it is not physically identifiable; PolarScale therefore evaluates dataset-conditioned semantic scale estimation against a constant-scale control, together with angular, self-consistency, and physical-bound metrics. Across seven restoration-based and generative backbones and three prediction strategies, the strongest restoration models estimate the scale with 3.6–4.3% mean relative error versus 5.7% for the constant control and violate physical bounds on fewer than 0.25% of pixels, whereas two generative baselines collapse to a near-zero scale; explicit descriptor supervision improves descriptor accuracy (23.66 vs. 18.88 dB PSNR for MAE). Predicted full-Stokes representations improve diffuse/specular separation, material segmentation, and glare classification, although in diffuse/specular separation the learned scale performs only on par with the constant control.

1 Introduction

Polarization imaging captures scene properties by measuring the polarization state of light, which is not observable with conventional RGB sensing. This additional polarization information provides cues about physical surface characteristics such as birefringence, surface stress, and micro-scale roughness. As a result, polarization imaging has enabled progress in challenging vision tasks, including reflection separation [1, 2, 3], material recognition [4, 5, 6, 7, 8], and shadow removal [9], complementing RGB-based region understanding [10, 11] and semantic segmentation [12]. Beyond vision, polarization is also a key degree of freedom in photonic hardware, where the polarization state of lasers can encode binary spins for photonic Ising computing [13, 14, 15].

However, acquiring polarization data typically requires dedicated polarization-sensitive hardware such as integrated linear polarizers and retarders [16, 17], and even controlling polarization at the source requires careful device engineering, such as engineered mesa geometries and integrated metasurfaces in polarization-controlled lasers [18, 19]. These systems increase sensor cost, reduce spatial resolution due to multiplexed designs, complicate calibration, and are difficult to integrate into large-scale or mobile vision platforms. Recovering absolute, radiometrically scaled Stokes vectors is more demanding still, since it additionally requires radiometric calibration of the polarimetric

*Corresponding author: zfyuan@nus.edu.sg †Equal contribution.

40th Conference on Neural Information Processing Systems (NeurIPS 2026). Track on Evaluations and Datasets.

Conventional RGB-based Polarization Estimation

PolarScale: Radiometrically Consistent RGB-to-Stokes Estimation (Ours)

Figure

Full Stokes components: S1S_{1}, S2S_{2}, S3S_{3} Radiometric scale: σ\sigma

Scale-dependent: s1s_{1}, s2s_{2}, s3s_{3} Scale-independent: AoLP, DoLP, DoCP

Figure 1: Overview of PolarScale. Prior RGB-based methods [22, 21] predict normalized Stokes components or relative polarimetric descriptors, from which the radiometric scale has been divided out. PolarScale additionally predicts the per-scene radiometric scale σ\sigma and reconstructs the full Stokes components Sn=σsnS_n = \sigma s_n, making the scale an explicit evaluation target. The input is the normalized total-intensity image s0=S0/σs_0 = S_0 / \sigma (Section 3.2), not a consumer sRGB photograph.

system. In practical deployment scenarios, such as robotics, autonomous systems, consumer imaging, and wearable sensing [20], these constraints significantly limit the accessibility and scalability of polarization imaging.

To overcome these barriers, recent methods infer polarization information directly from RGB-like images using neural networks [21, 22]. However, these approaches predict normalized Stokes components or relative polarimetric descriptors (Figure 1), from which the radiometric scale has been divided out. Such outputs describe relative polarimetric structure but cannot be turned into absolute Stokes vectors, which radiance-level applications require. For example, polarization-based diffuse/specular separation attributes the polarized radiance to the specular component [23, 24, 1], and glare depends on the amount of polarized light reaching the sensor rather than on the fraction of light that is polarized. Whether such absolute quantities can be estimated from intensity images has not yet been measured.

In this work, we introduce PolarScale, a benchmark that makes the radiometric scale an explicit prediction and evaluation target. PolarScale is built on the trichromatic full-Stokes measurements of the Spectral-Polarization dataset [16]. Its input is the normalized total-intensity image s0=S0/σs_0 = S_0/\sigma, a scene-referred linear intensity image rather than a consumer sRGB photograph; we keep the name “RGB-to-Stokes” established by [22] for continuity. Models predict the normalized Stokes components {s1,s2,s3}\{s_1, s_2, s_3\}, the descriptors AoLP, DoLP, and DoCP, and the per-scene scale σ\sigma, from which the full Stokes components follow as Sn=σsnS_n = \sigma s_n. Because σ\sigma is divided out of the input, it cannot be recovered by physical inversion; as in metric monocular depth estimation, it can only be inferred from scene content. PolarScale therefore measures dataset-conditioned semantic scale estimation, and, like diagnostic benchmarks that isolate specific failure modes rather than report only aggregate scores [25], we evaluate it accordingly: scale errors are scored against a constant-scale control, and wrap-aware angular, Stokes self-consistency, and physical-bound metrics complement standard image-quality scores.

Benchmarking seven restoration-based and generative backbones under three prediction strategies (direct, joint, and decoupled), we find that the strongest restoration models estimate the scale better than the constant control and nearly satisfy physical bounds, whereas two generative baselines collapse to a near-zero scale, and that full-Stokes PSNR is a poor measure of scale recovery. Three downstream probes show that predicted full-Stokes representations are useful, while scale-attribution controls show that the contribution of the learned scale itself is mixed, identifying scale accuracy as the open problem PolarScale is designed to track.

Our main contributions are summarized as follows:

Table 1: PolarScale compared with related resources. PolarScale re-uses the measurements of [16]; it differs in what is predicted and evaluated.

ResourcePrediction targetRadiometric scale evaluated?
Jeon et al. [16]N/A (physical acquisition, no prediction task)N/A
Lin et al. [22]normalized Stokes s1s_1, s2s_2, s3s_3No (scale divided out)
PolarAnything [21]relative descriptors (AoLP, DoLP)No (scale-invariant by definition)
PolarScale (ours)s1−s3s_1-s_3, AoLP/DoLP/DoCP, and σ→S1−S3\sigma \rightarrow S_1-S_3Yes (explicit target, with constant-σ\sigma control)
  • Task reformulation: PolarScale makes the radiometric scale an explicit prediction and evaluation target of RGB-to-Stokes estimation, and states its input modality and identifiability scope explicitly.

  • Physics-aware evaluation protocol: we score scale estimation against a constant-scale control and add wrap-aware AoLP angular error, Stokes self-consistency, and physical-bound violation metrics. All of them ship in a standalone benchmark package with the preprocessed splits, scale values, derived targets, evaluation scripts, and a datasheet.

  • Benchmark analysis and design guidance: we evaluate seven restoration-based and generative backbones under three prediction strategies, showing that explicit descriptor supervision and decoupled decoding help, and characterizing failure modes such as scale collapse.

  • Downstream validation: we show that predicted full-Stokes representations benefit three downstream tasks, and use scale-attribution controls to separate the contribution of the learned scale from that of the normalized polarization structure.

References (67)