Deformable CT-US Registration via Anatomy-Aware Implicit Neural Representations

Agnieszka Lach, Magdalena Wysocki, Feng Li, Mohammad Farid Azampour, Benjamin D. Killeen, Felix Ginzinger, Mathias Braun, Philipp Steininger, Heinz Deutschmann, Nassir Navab

Agnieszka Lach1,2^{1,2}, Magdalena Wysocki2^{2}, Feng Li2^{2}, Mohammad Farid Azampour2^{2}, Benjamin D. Killeen2^{2}, Felix Ginzinger1^{1}, Mathias Braun1^{1}, Philipp Steininger1^{1}, Heinz Deutschmann1^{1}, and Nassir Navab2^{2}

1^{1} medPhoton GmbH, Salzburg, Austria

2^{2} Computer Aided Medical Procedures, Technical University of Munich, Munich, Germany

agnieszka.lach@tum.de

Abstract. Slice-to-volume registration between ultrasound (US) and preoperative computed tomography (CT) imaging would enhance many minimally invasive interventions, for example by locating soft tissue structures intra-operatively that are discernible in CT. While optical tracking enables initial rigid registration, contact from the probe induces soft tissue deformations that inhibit accurate alignment. In this work, we introduce a deformable CT-ultrasound registration framework that incorporates anatomical priors derived from CT to improve registration under deformation. Rigid registration is first established using a robot-assisted optical tracking system, after which a deformable transformation is estimated using a sinusoidal implicit neural representation (SIREN) optimized per frame. Tissue stiffness is approximated from CT-based HU values and used as spatially varying regularization, suppressing deformation in rigid structures such as bone while allowing more flexibility in soft tissue. Two additional constraints capture the physics of probe contact: a contact-zone displacement prior that drives the displacement field to compress tissue below the probe face, and a fan-geometry regularization term based on beam direction and convex transducer field of view. Model parameters are optimized with a normalized gradient field (NGF). The proposed approach improves alignment over rigid initialisation by 17% and outperforms classical deformable baselines while maintaining near-zero topological folding.

Keywords: Deformable · Minimally invasive · Computer-assisted

1 Introduction

Tracked intra-operative ultrasound (US) provides real-time, quantitative information about soft tissue dynamics, enabling high precision guidance for interventional procedures [12]. To overcome US-specific limitations such as acoustic shadowing and shallow penetration, there is growing interest in combining US with preoperative and intra-operative computed tomography (CT) imaging [8, 9, 11, 17], thereby accessing 3D anatomical context dynamically. However, even with accurate rigid co-registration, e.g., via optical tracking, spatial

A. Lach et al.

Figure

(a) Patient Registered to CT

(b) Probe-induced Deformation

Figure

(c) Uniform Stiffness Deformation Model

(d) Anatomy-aware Deformation Model

Fig. 1. To enable precise anatomical alignment between tracked ultrasound and CT (a), it is necessary to account for probe-induced soft-tissue deformation (b). Existing methods are failing to incorporate anatomical constraints, allowing for non-physically plausible deformations (c) (exaggerated for visual clarity). We propose a deformable registration framework that incorporates known physical constraints and anatomical priors to constrain the deformation field, improving alignment while maintaining physical plausibility (d).

misalignment persists due to probe-induced soft-tissue deformation during US acquisition. Strong contact between the probe and soft tissue is necessary to achieve sufficient image quality, but the resulting pressure introduces spatial inconsistencies between the US and CT volumes, as shown in Fig. 1a-b. This prevents precise anatomical alignment for high precision interventions such as liver tumor ablation or biopsy [17]. While electromagnetic tracking can estimate deformation directly [17], it introduces significant complexity to clinical workflows and may be susceptible to interference from metallic objects. Thus, there is a need for deformable registration methods that reconcile tracked US with CT volumes while accounting for probe-induced tissue deformation.

Existing methods lack anatomy-aware constraints and thus risk non-physically plausible deformations (Fig. 1c): physical priors are either impractical—e.g. Geng et al. [3] require contact-force sensors unavailable in CT-US—or, in recent learning-based work, only folded into the training objective of convolutional [1, 5] or implicit neural representation (INR) [13, 16] models. INRs offer a compelling per-pair alternative to amortized learning, motivating our anatomy-constrained INR formulation.

Here, we propose a CT-US registration framework that incorporates known physical constraints and anatomical priors into an INR of deformation. Our primary contribution is the method which uses three anatomy-aware loss terms tailored to the CT-US slice to volume probe-contact setting, which are integrated with a NGF-based multi-modal similarity metric and Jacobian regularization [16]. First, we encode tissue stiffness as a spatially varying regularization term derived from CT-based segmentation without requiring any finite-element solver. Second, we introduce a contact-zone displacement prior that enforces

Figure

Ultrasound

CT

(a)

Speckle

Denoising

Displacement Field

US Overlay on Deformed CT

(b) Lmat\mathcal{L}_{\mathrm{mat}}

(c) Lcon\mathcal{L}_{\mathrm{con}}

(d) Lfan\mathcal{L}_{\mathrm{fan}}

Fig. 2. Proposed non-rigid CT volume to US slice registration pipeline. The workflow transitions from initial rigid alignment to a displacement field estimation. The deformation is governed by three novel regularization terms: (a) Lmat\mathcal{L}_{mat} for material stiffness preservation, (b) Lcon\mathcal{L}_{con} for contact-zone interface modeling, and (c) Lfan\mathcal{L}_{fan} for FOV-constrained spatial smoothing.

the physics of probe-induced surface compression by penalizing residual tissue in the crescent region between the probe face and the US fan arc. Finally, we tailor the optimization strategy to the fan-shaped, partial field of view of a convex transducer through beam-aligned directional regularization and an angular-tapered boundary weight that attenuates displacement toward the lateral fan horns where beam quality is weakest. We evaluate our approach on two datasets of robot-assisted US-CT acquisitions of abdominal phantoms, demonstrating superior alignment compared to both rigid initialization (up to 17% lower TRE) and classical deformable baselines.