arXiv:2610.08482cs.CVOct 2026

Manuscript Offprint

arXiv:2610.08482

Knee3DVLM: Dual-Sequence Full-Volume Vision-Language Modeling for Comprehensive Knee MRI Assessment

Maryam Baizhigitova, Andrew Seohwan Yu, Po-Hao Chen, Naveen Subhas, Sixu Chen, Xinxin Wang, Kunio Nakamura, Richard Lartey, Xiaojuan Li, Mingrui Yang

Maryam Baizhigitova 1,2^{1,2}, Andrew Seohwan Yu 1,3^{1,3}, Po-Hao Chen 3^{3}, Naveen Subhas 1^{1}, Sixu Chen 1,4^{1,4}, Xinxin Wang 2,3^{2,3}, Kunio Nakamura 1^{1}, Richard Lartey 1^{1}, Xiaojuan Li 1,3^{1,3}, Mingrui Yang 1^{1}

1^{1}Cleveland Clinic, Cleveland, OH 44106, USA

2^{2}Cleveland State University, Cleveland, OH 44115, USA

3^{3}Case Western Reserve University, Cleveland, OH 44106, USA

4^{4}Kent State University, Kent, OH 44242, USA

Vision-language models (VLMs) are increasingly being applied to three-dimensional medical imaging, with recent systems supporting report generation, visual question answering, localization, and segmentation [1,2]. Their application to knee MRI remains limited, particularly for interpreting the complementary sequences used in clinical practice. The closest existing approach, 3DReasonKnee, processes a single dual-echo steady-state (DESS) series [3], whereas radiologists integrate high-resolution DESS morphology with fluid-sensitive turbo spin-echo (TSE) signal. To address this clinical gap, we introduce Knee3DVLM, a sequence-aware VLM that uses full-volume DESS and TSE inputs to predict 57 anatomically resolved binary diagnostic targets derived from the MRI Osteoarthritis Knee Score (MOAKS) for structured reporting. Three configurations—Knee3DVLM-DESS, Knee3DVLM-TSE, and the fused dual-sequence Knee3DVLM—were evaluated using subject-disjoint Osteoarthritis Initiative partitions [4,5]. In a held-out test cohort of 1,074 examinations, we observed clinically coherent sequence-specific differences: DESS performed better for cartilage and osteophyte abnormalities, whereas fluid-sensitive TSE performed better for bone marrow lesions, meniscal abnormalities, ACL abnormalities, effusion-synovitis, and Hoffa-synovitis. The fused Knee3DVLM achieved 72.98% average accuracy, 71.17% balanced accuracy, 78.96% mean ROC-AUC, and 78.74% macro ROC-AUC, achieving the highest value among the three configurations on every reported aggregate endpoint. In a secondary multi-class analysis aligned with the released 3DReasonKnee cohort, Knee3DVLM achieved numerically higher accuracy than the strongest reported 3DReasonKnee configuration, Qwen2.5VL-3B, in all five pathology categories. These findings support dual-sequence full-volume modeling that more closely reflects clinical multisquence knee MRI interpretation.

Keywords: knee MRI; vision-language model; 3D imaging; multimodal fusion; DESS; TSE; MOAKS; osteoarthritis

1 Introduction

Knee osteoarthritis is a highly prevalent joint disease assessed across the entire joint using complementary imaging planes and pulse sequences rather than a single view. In routine interpretation, fluid-sensitive turbo spin-echo (TSE) images commonly serve as the initial survey because they depict meniscal, cruciate ligament, and marrow abnormalities, as well as joint effusion, periarticular cysts, and bursae. Contemporary European Society of Musculoskeletal Radiology recommendations similarly emphasize multiplanar fluid-sensitive imaging and systematic evaluation of every joint structure [6]. This sequence emphasis is also reflected in the OAI knee protocol: the first diagnostic acquisition after localization is coronal intermediate-weighted TSE, while sagittal fat-suppressed TSE provides the protocol's distinctive sensitivity to bone marrow abnormalities and subchondral cysts [5]. DESS supplies complementary thin-section, high-resolution depiction of cartilage morphology and osseous surfaces [7,8], but is relatively insensitive to marrow edema-like signal compared with fluid-sensitive TSE [9,5]. Radiologists therefore reconcile TSE and DESS findings across the whole joint; a DESS-only model cannot fully reproduce this multi-sequence workflow.

Medical VLMs first demonstrated broad visual question answering and generative capabilities on predominantly two-dimensional biomedical figures, radiographs, and other planar images [10,11]. More recent systems have extended image-language alignment to volumetric CT and MRI for report generation, question answering, localization, and segmentation [1,2]. Applied to knee MRI specifically, however, progress remains narrow: existing 3D VLMs generally process a single image series and are benchmarked on isolated diagnostic questions rather than comprehensive, multi-sequence whole-joint assessment.

The closest existing system, 3DReasonKnee, narrows this gap only partially: it introduced regional questions with localization, reasoning traces, and structured MOAKS severity assessments, but operates on DESS alone [3]. More general 3D VLM benchmarks such as M3D-LaMed [1] and Med3DVLM [2] demonstrate efficient full-volume encoding and language grounding but emphasize CT or single-series inputs and do not test clinically motivated sequence complementarity.

We close this gap with Knee3DVLM, a sequence-aware framework for full-volume knee MRI interpretation. Throughout this paper, Knee3DVLM denotes our paired, dual-sequence model; the single-sequence ablations are denoted Knee3DVLM-DESS and Knee3DVLM-TSE. Knee3DVLM makes three contributions:

  1. Sequence-preserving dual-volume architecture. Knee3DVLM uses independent full-volume DESS and TSE encoders and stream-specific tokenizers, retains acquisition identity through learned modality embeddings, and performs token-level fusion before projection into the language space. This design integrates complementary contrasts without collapsing them at the image or encoder-input level.

  2. Sequence-specific and dual-sequence evaluation. To examine how DESS and fluid-sensitive TSE affect VLM performance, we compared DESS-only, TSE-only, and fused DESS-TSE configurations on the primary 57-target binary task. This analysis tests whether sequence-specific performance follows clinically coherent tissue contrasts and whether combining both sequences improves overall performance.

  3. Category-wise comparison with 3DReasonKnee. As a secondary benchmark analysis, we aligned the original OAI data with the released 3DReasonKnee subject, visit, and knee-side identifiers and compared category-wise exact-grade average accuracy using the metric reported in that study (Table 5).