Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation

Onur Selim Kilic, Afra Nawar, Cem Okan Yaldiz, Michael J. Cho, Ahmet Rasim Emirdagi, Demet Tangolar, Amirali Aghazadeh, Amit J. Shah, Omer T. Inan

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Onur Selim Kilic

Georgia Tech

okilic3@gatech.edu

Afra Nawar

Georgia Tech

anawar3@gatech.edu

Cem Okan Yaldiz

Georgia Tech

cyaldiz3@gatech.edu

Michael J. Cho

Georgia Tech

mcho314@gatech.edu

Ahmet Rasim Emirdagi

Georgia Tech

aemirdagi3@gatech.edu

Demet Tangolar

Georgia Tech

dtangolar3@gatech.edu

Amirali Aghazadeh

Georgia Tech

amiralia@gatech.edu

Amit J. Shah

Emory University

ajshah3@emory.edu

Omer T. Inan

Georgia Tech

oinan3@gatech.edu

Abstract

Paired translation between quasiperiodic physiological waveforms (i.e., recovering a target oscillatory signal from the source) is central to the interpretation of cardiovascular signals derived from wearables placed at different body locations. This source-to-target mapping in these problems carries inherent geometric structure: the phase wraps around the cycle and must be treated as a circular variable, the amplitude remains strictly positive, and the beat-to-beat alignment can drift unpredictably across cycles and subjects. While deep neural networks have been used for phase estimation and complex-valued signal modeling, prior work does not explicitly learn phase transport between paired signals. Consequently, neither endpoint-supervised regression nor the standard affine path used in flow matching accounts for this phase–amplitude structure. We introduce cylindrical geodesic flow matching for paired cardiovascular waveform translation. We show that the standard affine path used in flow matching distorts intermediate amplitude and instantaneous frequency when interpolating between quasiperiodic signals; replacing it with a closed-form geodesic on the phase–amplitude cylinder eliminates these artifacts and converts each training pair into dense, geometry-consistent velocity supervision. On zero-shot photoplethysmography and limited-support seismocardiography adaptation benchmarks, our method consistently outperforms interpolation baselines and matches or exceeds direct supervised prediction, reducing Hilbert Transform, L2L_{2}, and Dynamic Time Warping distance by up to ∼15%\sim15\% over the strongest competing baseline. These results suggest that bridge geometry is a critical inductive bias for flow matching on oscillatory signal translation.

1 Introduction

Oscillatory physiological signals such as the photoplethysmogram (PPG) or seismocardiogram (SCG) are commonly used in wearable cardiovascular monitoring [6, 24, 17, 7, 11, 19, 12, 20, 14, 53]. Their morphology, however, depends strongly on measurement location: PPG waveforms vary substantially across body sites [15, 28, 42, 37, 54], and SCG recordings vary across chest placements and subjects [39, 40, 18, 1, 2, 59, 48, 38, 26, 36, 45]. Many algorithms and reference standards are calibrated on canonical sensing locations, such as sternal SCG and finger PPG, where mechanical and vascular

40th Conference on Neural Information Processing Systems (NeurIPS 2026).

biomarkers are most reliably expressed. As wearables move toward more convenient but morphologically distinct sensing sites, accurate recovery of target-site morphology is necessary to preserve compatibility with validated diagnostic pipelines and support reliable downstream cardiovascular inference. Location-to-location waveform translation is therefore a natural paired problem: given a source signal at one site, recover the corresponding waveform (i.e., target) at another.

This translation is difficult because physiological waveforms are quasiperiodic, that is, they exhibit repeating oscillatory structure whose phase, amplitude, and timing vary across cycles, subjects, and sensing locations. As a result, the source-to-target relationship is not a simple sample-by-sample transformation: phase is circular, amplitude is strictly positive, and inter-cycle alignment can drift unpredictably.

Direct supervised regression optimizes the prediction target but provides only sparse supervision. Each paired example contributes a single source-to-target residual, and the model must discover the underlying phase–amplitude geometry entirely from data. This is especially limiting when paired examples are scarce or cross-location alignment is ambiguous.

Conditional flow matching [27, 55] offers a complementary perspective. Each paired example generates supervision along an entire interpolating bridge, decomposing a difficult global transformation into a family of local velocity-regression problems [50]. Recent work has begun to apply advances in flow-matching to clinical and physiological time series, including irregular clinical trajectory modeling [56], electrocardiogram (ECG) synthesis [5], and PPG-conditioned vital-sign reconstruction [51].

Cross Location Translation

Figure

Figure 1: Cylindrical geodesic flow matching converts each source–target pair into dense velocity supervision along a geometry-aware bridge on the phase–amplitude cylinder, rather than relying on a single endpoint residual.

Figure 1 illustrates this training view. Instead of learning from a single endpoint residual, the model receives dense supervision along the bridge between paired signals. Here, for example, “non-standard” may refer to a less-explored body location, such as the clavicle for SCG signals, whereas “standard” refers to a well-established location, such as the sternum. The resulting dense supervision yields a more favorable optimization landscape, but only if the bridge itself respects signal geometry. The standard affine path used in existing physiological flow-matching models cuts across the natural phase–amplitude structure of quasiperiodic signals, producing intermediate states with distorted amplitude and spurious instantaneous frequency, which can ultimately degrade the translated waveform.

To address this geometric mismatch, we introduce cylindrical geodesic flow matching. Specifically, we represent each signal sample by its instantaneous phase ϕ\phi and amplitude aa as (cos⁡ϕ,sin⁡ϕ,a)∈S1×R>0(\cos \phi, \sin \phi, a) \in S^1 \times \mathbb{R}_{>0}, where S1S^1 denotes the unit circle. This embedding removes the discontinuity at phase wrapping while keeping amplitude explicit. On this cylinder, we then replace the standard affine interpolation path with a closed-form geodesic that respects phase periodicity by construction, eliminates the amplitude and frequency distortions inherent to the affine path, and yields an oracle vector field aligned with the phase–amplitude geometry of the task. We further parameterize the learned vector field intrinsically. Instead of predicting an unconstrained vector in R3\mathbb{R}^3, the model predicts phase and amplitude velocities, which are mapped to a tangent vector on the cylinder; combined with a per-step projection, this keeps the numerical trajectory on the manifold throughout integration.

The cylindrical representation, geodesic interpolation, and intrinsic tangent parameterization define a geometry-aware training framework for quasiperiodic waveform translation. These components address complementary aspects of the phase–amplitude structure, from endpoint representation and bridge construction to the learned dynamics along the path. On zero-shot PPG and limited-support SCG benchmarks, we demonstrate that the resulting framework consistently outperforms interpolation baselines and matches or exceeds direct supervised prediction across all reported metrics. Therefore, our main contributions are:

  • A cylindrical manifold representation (cos⁡ϕ,sin⁡ϕ,a)∈S1×R>0(\cos \phi, \sin \phi, a) \in S^1 \times \mathbb{R}_{>0} for physiological signals that eliminates phase-wrap discontinuities and preserves positive-amplitude structure. To our knowledge, no prior work explicitly learns phase transport between paired signals. Our formulation enables stable, direct learning of cross-signal phase–amplitude correspondences on the appropriate product manifold.

• A closed-form geodesic path and oracle velocity field on the cylinder for conditional flow matching, converting each training pair into dense, geometry-consistent supervision.

• Theoretical results showing that the standard affine path fails to preserve the phase–amplitude geometry of quasiperiodic cardiovascular signals, inducing amplitude shrinkage and instantaneous-frequency warping that can lead to lower quality translated signals, whereas the cylindrical geodesic preserves this geometry.

• Empirical validation across a range of settings, demonstrating that cylindrical geodesic flow matching outperforms competing methods.