Robust Surgical Robotic Instrument Tracking via Sequential Multi-Cue Fusion and Sim-to-Real Self-Training

Hanyang Hu, Zekai Liang, Florian Richter, Michael C. Yip

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Hanyang Hu 1^{1}, Zekai Liang 1^{1}, Florian Richter 1^{1}, Michael C. Yip 1^{1}, Senior Member, IEEE

Abstract—Efficient and robust tracking of surgical robotic instruments is important for robot-assisted minimally invasive surgery, yet remains challenging due to the complexity of surgical scenes and the unconventional geometry of surgical instruments. Keypoint-based approaches are efficient, but their performance depends on reliable feature detection. Improving these detectors with real-world supervision is difficult because accurate real-world annotations are costly to obtain at scale. To address this limitation, we introduce a tracker-guided self-training framework that adapts a model pretrained on synthetic images to unlabeled real-world videos. Given measured robot joint states, an uncertainty-aware EKF recursively corrects the instrument pose and the observable joint angles by comparing projected model features with detected keypoints, shaft boundaries, and mask-derived cues. An RTS smoother subsequently refines the resulting trajectory, which is projected into pseudolabels for fine-tuning the feature detector without laborious pose annotations. Experiments on real-world videos demonstrate consistent improvements from self-training across all evaluated keypoint metrics, and the resulting model outperforms prior approaches in both accuracy and runtime. The code and data will be released upon publication.

I. INTRODUCTION

Robot-assisted minimally invasive surgery (RMIS) has gained increasing attention for improving surgical safety and efficiency while reducing surgeon fatigue. Accurate, low-latency estimation of articulated instrument pose relative to the endoscopic camera is a fundamental perception capability in RMIS. Reliable pose feedback supports downstream tasks including visual servoing [1], augmented-reality guidance [2], and autonomous tissue manipulation [3].

Modern approaches to markerless surgical robotic instrument pose estimation generally follow one of two paradigms: keypoint detection with PnP-based pose reconstruction [4]–[7], or instrument segmentation followed by iterative render-and-match optimization [8]–[11]. Given the computational complexity of rendering-based optimization methods, keypoint-based pose estimation methods are generally better suited to real-time robot control due to their fast inference speed. However, their accuracy depends heavily on reliable visual feature detection, which is prone to suboptimal endoscopic imaging conditions.

Compared with general robotics, the scarcity of accurately annotated real-world data makes improving feature detection robustness for surgical robots particularly challenging. Prior work has explored synthetic data generation with photo-realistic rendering to alleviate the scarcity of annotated

Synthetic Pretrained

Ours (Self-Trained)

Figure

Fig. 1: Self-training improves sim-to-real feature detection. Pretrained and self-trained models are compared on unseen real-world images with diverse orientations, distractions, and occlusions. Circles and dashed white lines denote manually labeled ground truth; plus signs and solid yellow lines denote model predictions. A tracker-guided self-training framework enables a synthetically pretrained model to bridge the gap to challenging, real-world scenes without tedious human labeling.

real-world data [5], [7]. Although these approaches have demonstrated promising feasibility and performance gains, a substantial sim-to-real gap remains. Synthetic data alone is often insufficient to achieve the robustness required for reliable deployment in real-world applications.

To address the scarcity of annotated real-world data in surgical robotics, we present a self-training framework for surgical instrument pose reconstruction that enables sim-to-real transfer using unlabeled real-world images. During adaptation, a distribution-aware Extended Kalman Filter (EKF) [12], followed by a Rauch-Tung-Striebel (RTS) smoother [13], aggregates observations across unlabeled real-world trajectories to obtain robust and temporally consistent pose estimates. These estimates are then projected back into the image space to generate pseudo-labels, which provide supervision for adapting the model to the target domain without requiring ground-truth annotations (Fig. 1).

The main contributions of this work are as follows:

  1. A self-training framework that leverages unlabeled real-world images to improve the accuracy and robustness of surgical robotic instrument feature detection.

  2. An efficient, distribution-aware EKF that fuses complementary keypoints, shaft edges, and mask-derived observations for robust instrument pose tracking.

1^{1}Department of Electrical and Computer Engineering, University of California San Diego, La Jolla, CA 92093 USA. {hanyang-hu, z9liang, frichter, yip}@ucsd.edu

Figure

Fig. 2: Overview of the proposed self-training framework. A query-based multitask model predicts keypoint heatmaps, shaft edge heatmaps, and instrument masks from RGB video, which are decoded into geometric observations with associated uncertainty. Sequential multi-cue fusion combines these observations with robot kinematics to obtain smoothed pose trajectories, using an initial base-to-camera transform TbcT_b^c estimated by differentiable rendering [8]. An EKF propagates the instrument state between frames and updates it using the current frame's observations, while a backward RTS smoother refines these pose estimates to produce a smoothed pose trajectory. Pseudo-label generation projects and renders the smoothed instrument configurations into feature labels for sim-to-real adaptation.

  1. A pose-to-feature pseudo-labeling strategy that converts smoothed trajectories into feature annotations with consistency-based sample weighting.

References (36)