Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements ( r=0.68–0.90r = 0.68–0.90, p<0.001p < 0.001, and RMSE = 4.18–6.49°), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates ( r=0.85–0.87r = 0.85–0.87, p<0.001p < 0.001, and RMSE = 2.13–2.19 Nkg −1^{-1}). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury.

Introduction

Three-dimensional gait analysis provides a quantitative description of walking that helps distinguish primary neuromotor deficits from compensatory strategies such as hip hiking, circumduction and trunk lean, and it links movement patterns to joint loading, falls, and secondary injury 1,2^{1,2}. In routine clinical practice, however, observational assessment often cannot determine whether a deviation is a cause or a consequence of weakness, spasticity, pain, or balance limitation, and similar outward patterns can reflect different underlying mechanisms 3,4^{3,4}. Clinical 3D gait analysis addresses this ambiguity by combining kinematics with external loading (GRFs and CoP) across the gait cycle, enabling clinically interpretable joint-angle and joint-moment estimates that can guide rehabilitation, orthoses, and surgery, and that can support longitudinal outcomes assessment when gait speed changes are difficult to anticipate 1,5,6^{1,5,6}. In spinal cord injury (SCI), where impairment ranges from subtle interlimb asymmetry to profound paresis with assistive device use, quantitative gait analysis can reveal locomotor function beyond broad clinical scales, sensitively capture change over time, and help characterize strategy-level differences among individuals walking at similar speeds 7,8^{7,8}. Conventionally, this is performed with multicamera, marker-based motion capture (MoCap) and force plates 3,5^{3,5}. Despite its clinical utility and integration with musculoskeletal toolchains such as OpenSim 9^{9}, MoCap is expensive, labor intensive, and operator dependent, which limits frequent assessment and broader clinical deployment 1,4,6^{1,4,6}. Moreover, soft-tissue artifacts and marker-placement variability can introduce nontrivial joint-angle errors, with downstream impacts on derived joint moments 10−14^{10-14}.

Over the past decade, several approaches have been developed for higher-fidelity 3D kinematics extraction by pairing 2D detection with multi-camera calibration and triangulation, as implemented in commercial systems (Theia3D) and open-source workflows such as OpenCap and Pose2Sim 15−17^{15-17}. Across studies, these multi-view keypoint pipelines show encouraging agreement with MoCap for many spatiotemporal outcomes and for several sagittal-plane joint-angle waveforms, whereas the agreement is less consistent for distal joints, non-sagittal-plane rotations, and patient cohorts 14,18−24^{14,18-24}. This has supported

Figure

Figure 1. Monocular markerless gait analysis workflow and downstream clinical inference used in this study. (1) Synchronized monocular sagittal-plane video and force-plate GRF acquisition. (2) Video preprocessing with 2D pose estimation and body segmentation. (3) Monocular 3D human-mesh recovery (HMR) with body-model constraints for robust occlusion. (4) Extraction of virtual markers from the 3D mesh (head, shoulders, ASIS, hip, knee, ankle, heel, and toe). (5) Participant-specific OpenSim model scaling/alignment to enable kinematics and GRF prediction. (6) Inverse kinematics (IK) yields joint-angle waveforms; kinematics-based prediction of vertical GRFs (pGRFs) provides kinetic estimates; performance is summarized by IK accuracy (correlation with MB) and pGRF error (RMSE, N/kg). (7) Graph-based conditional-dependence analysis links principal components of kinematic/GRF features to clinical outcomes (SCIM, AIS, injury category/subcategory, and etiology), with Markov blankets highlighting conditionally relevant associations. (8) Two-stage unsupervised clustering: speed stratification (slow/medium/fast) followed by within-stratum mechanics subclustering to identify coordination/compensatory strategies. (9) Results dashboard for clinicians (kinematic waveforms, predicted GRFs, summary metrics, and clustering/graph insights) to support interpretation and rehabilitation planning. (10) Patient-facing visual feedback and a personalized rehabilitation plan close the loop between quantitative gait assessment, clinician guidance, and rehabilitation planning.

semi-markerless gait analysis for clinical outcomes assessment, where video provides 3D kinematics while GRFs are still measured using force plates so that inverse dynamics can be retained and the clinical implications of kinematic error for joint moments and loading can be quantified 1,22,25−27^{1,22,25-27}.

To reduce reliance on multi-camera infrastructure and enable more accessible deployment in clinical settings, a large body of work targets 3D pose estimation from fewer views, including monocular video. 2D-to-3D lifting maps 2D keypoints to 3D joint coordinates under learned kinematic and anthropometric priors 28^{28}. For gait, temporal models further exploit motion continuity to stabilize trajectories, reduce frame-to-frame jitter, and partially resolve depth ambiguity in the presence of self-occlusion 29^{29}. Despite rapid progress, monocular 3D poses remain limited by scale ambiguity, out-of-plane rotations, and viewpoint-dependent occlusions, leading to keypoint noise and occasional mistracking that abruptly shift joints, yielding anatomically implausible configurations such as extreme limb angles and inconsistent limb lengths compared with those of multi-camera approaches 30^{30}. These are exacerbated in real-world gait videos with assistive devices and atypical postures 31^{31}.

Building upon these pose estimation advances, computer vision models have also shifted from sparse joints to dense, person-specific body reconstructions via human mesh recovery (HMR) and parametric models such as SMPL, originally developed for graphics and virtual avatar creation 32−35^{32-35}. With respect to biomechanics, meshes are appealing because they provide temporally consistent surface correspondences that can, in principle, be mapped to anatomically motivated virtual markers and used to drive musculoskeletal modeling toolchains. Recent “in-the-wild” monocular biomechanics pipelines such as OpenCap Monocular combine single-view video with learned body-model priors and optimization/smoothing to recover kinematics without a dedicated multi-camera lab setup 36^{36}. Complementary directions integrate stronger foreground/part segmentation and video object tracking (segmentation-driven capture such as SAM4DCap) 37^{37} to improve robustness under occlusion, truncation, and complex backgrounds, which are common in clinical gait recordings with assistive devices. In practice,

2/53 however, mesh-to-skeleton conventions, virtual-marker definitions, and model-scaling procedures are not yet standardized, and mesh-based monocular gait pipelines remain under-validated for atypical or neurological gait, which limits confidence for clinical interpretation 36,38−40^{36,38-40}. A scope comparison of representative systems and their support for OpenSim, GRFs/kinetics, clinical phenotyping, and SCI evaluation is provided in Supplementary Table S1.

Even with accurate kinematics, real-world biomechanics remain constrained by the need for force instrumentation. Standard inverse dynamics require the GRFs and center-of-pressure (CoP) to compute joint moments, which are central to clinically interpretable estimates of joint loading; however, force plates are expensive, spatially restrictive, and difficult to deploy in remote clinics or homes. To mitigate this bottleneck, GRF estimation from motion has been studied in several settings, including multi-camera (multi-view) markerless capture, where 3D kinematics are well constrained 41^{41}, as well as pipelines that use marker-based or markerless kinematics as the input to learning- or optimization-based GRF predictors 36,42,43^{36,42,43}. In these controlled configurations, the agreement with force-plate measurements can be strong, supporting the feasibility of GRF prediction from kinematics 41−43^{41-43}. However, these successes have typically not been extensively validated across diverse populations for GRF estimation, and the corresponding fully markerless inverse-dynamics pipeline, with joint moments computed from predicted GRFs/CoP, has not been broadly validated beyond the datasets and conditions used for model development.

The existing approaches have several clinically important limitations that impede their translation to monocular “in-the-wild” gait analysis. Many GRF/CoP predictors have been developed and validated under controlled conditions, and robustness under clinically relevant domain shifts, including viewpoint, clothing, background clutter, assistive devices, atypical postures, and altered foot-ground contact mechanics, remains insufficiently characterized. More broadly, the field has not yet converged on a rigorously validated end-to-end pipeline that jointly yields fully markerless monocular kinematics together with sufficiently accurate 3D GRFs for clinical populations. In addition, evidence remains limited on how HMR model choice affects mesh fidelity in specific pathologies and how reconstructions should be standardized through virtual-marker definitions and model scaling to produce trustworthy downstream kinematic and kinetic outputs. Critically, to our knowledge, no prior work has combined such a fully monocular, fully markerless kinematics–kinetics pipeline with a comprehensive, pathology-focused biomechanical analysis in SCI, including clinically interpretable biomechanical biomarkers that stratify individuals into mechanistically distinct subgroups.

In this study, we demonstrate and validate a monocular, calibration-free markerless pipeline for comprehensive gait assessment in individuals with spinal cord injury (SCI), bridging the gap between computer-vision body recovery and clinical neurorehabilitation (Figure 1). Clinically, it is difficult to anticipate who will improve in walking speed, in part because individuals can achieve similar speeds using different coordination and compensation strategies; therefore, an actionable clinical question is whether we can identify reproducible biomechanical patterns within and between groups, and then determine which of these patterns are plausible targets for intervention (i.e., which mechanisms to treat and which features to monitor as therapy outcomes) 6,8^{6,8}. Our work establishes three primary contributions, including a comprehensive benchmark of five state-of-the-art 3D human mesh recovery models on our pathological walking dataset, SCAI SCI Gait (N = 239), and demonstrates that parametric whole-body constraints prevent anatomically implausible limb deformations during pathological asymmetry and occlusion. We quantify the physical limits of kinematics-to-force prediction (GaitDynamics) in service of scalable clinical kinetics, and we apply conditional-dependence graphical models to discover minimal Markov blankets of functional recovery and employ speed-disentangled clustering to uncover latent mechanical phenotypes that are masked by conventional clinical examinations.