Manuscript Offprint
arXiv:2610.05583TacGELLO: Tactile Contact Feedback for a 3D-Printed Teleoperation Leader
Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.
Abstract
Passive leader arms transmit an operator's motion without returning remote contact or load cues. TacGELLO uses the existing servos of a 3D-printed leader for tactile contact feedback at the gripper trigger and current-based load cues at the arm joints. AnySkin contact detection activates a trigger position hold, while changes in follower joint current adjust leader-servo output limits to command resistance during lifting.
Across six UR3 sessions with one operator, sent-command tracking error was 0.15–0.36° RMSE, with estimated trajectory lag of 82–98 ms. Tactile onset was logged in 60 of 62 segmented TacGELLO grasp intervals. Median commanded closure after tactile or width-based contact references was 0.7–2.1 mm with TacGELLO and 13.0–13.9 mm with the original interface. Separate lifting recordings showed arm-cue command activation.
Command dynamics and contact references differed between interfaces, preventing attribution of the closure difference to tactile feedback alone.
1 Introduction
Leader-arm interfaces map an operator's joint motion to a robot manipulator for teleoperation and demonstration collection. GELLO uses a low-cost, 3D-printed replica of the follower's kinematics [Wu et al., 2024]. ALOHA provides a related interface for bimanual manipulation [Zhao et al., 2023]. In their passive configurations, both transmit motion without returning remote contact forces. An operator grasping a fragile object must infer contact visually while controlling closure. UMI collects demonstrations with a handheld gripper that interacts directly with the object [Chi et al., 2024].

Figure 1: TacGELLO in use. The operator moves the 3D-printed leader and the UR3 follows it, here lifting a can with the tactile gripper. When the AnySkin fingertips detect contact, the leader's trigger servo holds the trigger, so the operator feels the grasp.
Force and tactile feedback have reduced applied forces and damaging errors in surgical studies [Wagner et al., 2007; King et al., 2009]. Assembly studies show that the benefit depends on the task and feedback quality [Wildenbeest et al., 2013]. In a door-opening imitation-learning task, haptic feedback during demonstration collection improved data quantity and downstream performance [Cuan et al., 2024]. These findings support investigating inexpensive feedback for leader arms. The effectiveness of a servo-based implementation still needs to be evaluated in its intended task.
FACTR combines leader-arm feedback from follower joint-torque estimates with gripper-current feedback at the trigger [Liu et al., 2025a]. Echo uses force-sensing resistors in the follower fingers to provide grip feedback on a UR teleoperation interface [Bazhenov et al., 2025]. AnySkin measures spatially distributed signals from fingertip deformation using magnetic sensing [Bhirangi et al., 2025b].
al., 2025]. We use these signals to detect contact and activate a trigger position hold, without estimating force in newtons. Our contribution concerns this contact signal and rendering mechanism; FACTR has already demonstrated combined arm and gripper feedback.
TacGELLO is a 3D-printed leader and tactile gripper for the Universal Robots UR3 (Fig. 2). It uses existing leader servos for two feedback channels: tactile contact feedback at the gripper trigger and current-based load feedback at the arm joints. Fingertip contact activates a capped hold on the trigger servo. The load-feedback channel maps changes in UR3 joint current to output limits on selected leader servos, commanding an arm-resistance cue during lifting without a dedicated arm force/torque sensor. This cue has not been calibrated as payload weight or rendered joint torque. We contribute:
-
A UR3 leader and two-finger tactile gripper that render fingertip contact through an existing trigger servo.
-
A current-based load-feedback channel that commands resistance at selected leader-arm joints from UR3 joint-current changes.
-
A characterization of sent-command tracking, selected software timings and exploratory fragile-object grasping behavior, with arm-load pilots.
The grasping sessions compare two complete interfaces with different command dynamics and contact references. They characterize the prototype, but cannot isolate the effect of tactile feedback.
2.1 Low-cost teleoperation interfaces
GELLO uses kinematically matched leader replicas built from hobby servos [Wu et al., 2024]. ALOHA and ALOHA 2 use backdrivable leader arms for bimanual puppeteering [Zhao et al., 2023; ALOHA 2 Team et al., 2024], and AirExo uses wearable exoskeletons [Fang et al., 2024]. Passive remote leaders transmit the operator's motion without reflecting follower contact forces. UMI replaces the leader arm with a handheld gripper [Chi et al., 2024]. Contact occurs locally at the device during demonstration collection, so it does not provide remote follower-force reflection.
2.2 Force feedback and bilateral control
Classical bilateral teleoperation established the trade-off between transparency and stability [Lawrence, 1993; Hokayem and Spong, 2006]. Bilateral-control imitation learning uses observer-based force estimation to exchange position and force information, recording both for policy learning [Adachi et al., 2018; Buamanee et al., 2024; Kobayashi et al., 2025; Yamane et al., 2025]. FACTR provides compensated leader-arm feedback from follower external joint torques and gripper feedback from follower gripper current [Liu et al., 2025a]. FACTR 2 studies learned external-force estimation on commodity arms [Oh et al., 2026]. GELLO+F renders Franka external-torque estimates through current-controlled leader motors [Sujit et al., 2025]. Input-gated bilateral teleoperation is another approach for low-cost hardware [Kanai et al., 2025].
Table 1: Feedback source and presentation in selected interfaces. Local interaction in a handheld device differs from remote follower-force reflection.
| System | Signal and presentation |
|---|---|
| GELLO [Wu et al., 2024] | passive remote leader |
| ALOHA [Zhao et al., 2023] | passive remote leader |
| UMI [Chi et al., 2024] | handheld gripper; local mechanical interaction |
| Bi-ACT [Buamanee et al., 2024] | observer-based joint-force feedback |
| FACTR [Liu et al., 2025a] | external joint torque to arm; gripper current to trigger |
| GELLO+F [Sujit et al., 2025] | Franka external torque to current-controlled leader |
| Echo [Bazhenov et al., 2025] | finger force sensors to trigger; arm passive |
| TactAR [Xue et al., 2025] | tactile state as visual AR overlay |
| TacGELLO | tactile contact to trigger hold; joint-current change to arm cue |
Echo uses a force-sensing resistor in each follower finger and renders grip feedback at the leader trigger, with passive arm joints [Bazhenov et al., 2025]. Prometheus renders grip-force feedback in a handheld motion-capture controller [Satsevich et al., 2025]. TacGELLO uses magnetic fingertip contact sensing to activate a capped trigger hold, alongside a separate arm-current cue. We have not compared its effectiveness directly with these systems.
2.3 Tactile sensing and policy learning
AnySkin is a replaceable magnetic tactile skin consisting of a magnetized elastomer over five 3-axis magnetometers, with readings that respond to normal and shear deformation [Bhirangi et al., 2025]. It builds on ReSkin [Bhirangi et al., 2022]; eFlesh extends magnetic sensing to customizable 3D-printed geometries [Pattabiraman et al., 2025]. TactAR presents tactile state visually through augmented reality alongside Reactive Diffusion Policy [Xue et al., 2025]. DOGlove provides haptic feedback for dexterous hands [Zhang et al., 2025]. TacGELLO presents a contact event at the trigger of a parallel-jaw leader.

(a) Leader and follower

(b) UR3 and gripper

(c) Container grasp

(d) Bottle grasp
Figure 2: TacGELLO hardware and example grasps. (a) The 3D-printed leader in the foreground and the UR3 follower behind it. (b) The UR3 fitted with the two-finger gripper. (c,d) The gripper holding a cylindrical container and a water bottle. Each fingertip carries an AnySkin tactile sensor. The photographs are cropped for presentation and illustrate the hardware only; they are not used to score experimental outcomes.
Visual-tactile policies and human contact measurements have been used for fine-grained manipulation [Huang et al., 2024; Adeniji et al., 2025]. ForceMimic, FoAR and Adaptive Compliance Policy further motivate recording force-related information during demonstrations [Liu et al., 2025b; He et al., 2025; Hou et al., 2025]. These studies motivate future policy-learning experiments with TacGELLO. The present evaluation covers teleoperation only.
3 System Design
3.1 Hardware
The leader is a GELLO-style [Wu et al., 2024] 3D-printed, kinematically matched replica of the UR3, with six joint servos and a trigger servo, all STS3215 serial-bus actuators. We enable the leader servos with limited output to render the cues.
We designed a 3D-printed two-finger gripper for the UR3 (Fig. 2b–d). Two STS3215 serial-bus servos drive its printed linkage fingers through an ESP32 controller, over a commanded opening range of 0–130 mm. An AnySkin skin [Bhirangi et al., 2025] forms the contact pad of each fingertip, so the surface that grasps the object is also the surface that senses contact. Each sensor's magnetometers are read by its own Adafruit QT Py microcontroller, which streams the readings to the host over USB. AnySkin separates the replaceable skin from its sensing electronics, so a worn pad can be swapped without rewiring the gripper.
3.2 Teleoperation loop
The host PC reads leader joint angles, applies a fixed startup alignment offset and smooths the targets before streaming commands to the UR3 through the RTDE servoJ interface (Fig. 3). The median valid control interval in the grasping recordings is approximately 16.65 ms. The host maps trigger position to commanded gripper width and publishes a ROS command. A host-side TCP/Bluetooth bridge forwards motor commands to the ESP32, which drives the gripper servos over their serial bus. The AnySkin measurements return separately over USB. Section 4.2 reports the empirical trigger-to-width calibration for the two interfaces. We timestamp host events with a monotonic clock. RTDE supplies robot timestamps, but the two clocks are not synchronized, which limits the timing measurements.
3.3 Fingertip channel: contact at the trigger
Each AnySkin fingertip contains five 3-axis magnetometers. Contact detection compares field magnitudes with an empty-gripper baseline that varies with gripper configuration, without estimating force in newtons. We record each fingertip's five field magnitudes, baseline values, grouped deviations and controller contact flag, with a detection margin of 20 sensor units. The grouped deviations keep the first and last magnetometer differences and the maximum of the three middle differences. The controller contact flag drives the trigger hold and defines contact onset in the analysis. Because the flag also reflects gripper operation and release, a threshold applied independently to the stored deviations would define a different contact reference.
On contact, the existing trigger servo holds its measured position to provide a contact-resistance cue. The experimental setup specified an output limit of 150 raw servo units. The gripper controller writes a position tar-

Figure 3: Experimental system architecture. Black: command path. Blue: signals used for feedback. Feedback commands act through the leader's own servos, by holding the trigger and adjusting joint servo output limits. The AnySkin USB streams are separate from the ESP32 motor-control link. No dedicated arm force/torque sensor or additional leader actuator is used.
get and enables servo output, then releases the hold when the trigger moves toward open or contact clears. It also attempts release when contact messages become stale. Output-limit readback was not recorded, so the cap was not independently verified. Resisting torque and the force needed to override the hold were not calibrated. The cue conveys contact onset, with no graded grip-force estimate.
3.4 Arm channel: current-driven resistance cue
Measured UR3 shoulder, elbow and first-wrist joint currents are compared with an empty-arm baseline. The arm cue uses position-lag control with limited servo output. Changes in follower current adjust the output limits of the corresponding leader servos to command resistance during lifting. Section 4.3 gives the settings for each load condition. Posture and motion also affect current, so this signal is not a calibrated weight estimate. We evaluate cue-command activation; rendered joint torque has not been measured.
3.5 Operating limits
The teleoperation code limits joint-command steps and checks encoder ranges. Leader-servo output limits have not been calibrated as physical torque or manual-override force. Cue release after host failure or communication loss has not been tested. We tested non-ferromagnetic objects because ferromagnetic material can affect magnetic sensing.
3.6 Adapting the interface
Adapting the fingertip cue requires a compatible follower-gripper interface. The arm cue also needs a joint mapping, appropriate current or torque measurements and control settings for that follower. A kinematic leader replica must match the new arm. We have not evaluated portability beyond the UR3.
4 Experiments
We recorded (E1) joint-command tracking and selected software timings, (E2) fragile-object grasping with two gripper interfaces, and (E3) arm-current cue activation during lifting. One author operated the leader throughout. We collected system logs without subjective ratings.
4.1 E1: Command tracking and timing
We compare sent follower joint commands with measured UR3 angles across the six E2 grasping sessions, using the host-observed sample associations. The sent commands include leader offset alignment and smoothing. This measures follower command tracking; the complete error between raw leader measurements and follower motion is outside this measurement.
We pool samples across all six sessions to compute same-time RMSE. For each joint-session with at least of cumulative commanded travel, we linearly interpolate both angle trajectories onto a 2 ms grid and take first differences. We estimate lag as the nonnegative shift below 400 ms that maximizes the normalized dot product of those differences, then report the median lag and median aligned RMSE over qualifying sessions. The 2 ms interpolation grid does not give physical timestamp accuracy at that scale. The robot and host clocks are not synchronized.
For each software stage, we take the median of available session medians: six sessions for arm stages and the three TacGELLO sessions for gripper stages. Effective recording rate is the median, across sessions, of sample count divided by recording duration. We also report the median midpoint of 634 host-observed motion-response brackets for displacement. Transport, polling and continuous command streaming prevent assigning this statistic to the latency of an individual command.
4.2 E2: Fragile-object grasping
The operator repeatedly grasped and released a potato chip, an empty paper cup and a thin-walled plastic bottle. Each object was replaced between grasps. For each object type, we recorded one TacGELLO session with direct trigger-to-width commands and tactile trigger hold, and one original-interface session with feedback off and rate-limited commands. TacGELLO was recorded first
Table 2: Segmented intervals and available contact references. T: tactile onset; W: width fallback; -: no reference.
| Object | Interface | Total | T | W | - |
|---|---|---|---|---|---|
| Chip | TacGELLO | 19 | 18 | 1 | 0 |
| Original | 23 | 0 | 21 | 2 | |
| Cup | TacGELLO | 20 | 19 | 1 | 0 |
| Original | 17 | 0 | 14 | 3 | |
| Bottle | TacGELLO | 23 | 23 | 0 | 0 |
| Original | 25 | 0 | 21 | 4 |
for the chip and bottle; the original interface was first for the cup. Conditions were not randomized or blinded.
Both feedback and command dynamics change between conditions. During closing samples, median command deviation from the common nominal trigger-to-width target was 16–27 mm for the original interface and approximately 0.1 mm for TacGELLO. Median original-interface closing speeds were 41–44 mm/s. These checks describe the recorded command behavior, without establishing identical mapping calibration across conditions.
Segmentation and contact references. We segment consecutive samples whose commanded width falls below 0.8 times the session's 95th-percentile commanded width, retaining runs with a first-to-last-sample duration exceeding 0.5 s. Thresholds were 104.0 mm for all TacGELLO sessions and 99.8, 101.9 and 101.7 mm for the original chip, cup and bottle sessions. Table 2 gives interval counts. Grasp success was not independently verified.
For each interval, we use the first logged tactile onset from 0.5 s before its start to its end. If no tactile onset is available, we use the first commanded-width sample in that window at or below the median commanded width at all tactile onsets in the corresponding TacGELLO session: 61.3, 87.2 and 92.4 mm for chip, cup and bottle. This width fallback applies to both original sessions and two TacGELLO intervals. Nine original-interface intervals never reach the reference and lack contact-dependent outcomes. Original-interface tactile data were not logged, so the width reference is a proxy rather than measured physical contact.
Outcome definitions. We compute commanded closure after the contact reference as the nonnegative difference between width at the reference and minimum commanded width from that reference to 0.2 s after the segment end. This is a command change; physical aperture and force are unmeasured. Trigger rotation uses the minimum valid encoder value from 1.5 s before the segment start to its end, relative to a common engagement reference of 3924.712 counts. Samples at or below 3000 counts are rejected as wrap artifacts. We use 360/4096 degrees per count.
Finger-servo closure is the average of the two servos' individual maximum closing rotations relative to their fully open references, using samples from 1.5 s before the segment start to 0.5 s after its end. The two extrema need not occur simultaneously. Open references are medians while commanded width is at least 129.5 mm. One original bottle interval lacks the necessary finger samples. These encoder measures are not calibrated grip force or damage.
Five steady-state trigger-to-width fits have slopes of 0.234–0.237 mm/count. The original bottle fit is anomalous: 0.123 mm/count with 12.43 mm residual RMSE. We therefore cannot establish equal empirical calibration. Trigger results retain the common reference above, with this limitation.
We report medians, quartiles and Cliff's , where negative indicates smaller TacGELLO values. Repeated intervals share an operator and session. With one session per object-condition, per-grasp significance tests cannot establish a causal or population-level feedback effect, so we use descriptive summaries.
4.3 E3: Arm-current feedback during lifting
We performed preliminary lifting tests to record changes in UR3 joint current and the corresponding resistance commands generated for the leader arm.
Two conditions were tested. In the first, the operator alternated between a 20 g toy can and a 600 mL water bottle, performing two grasps with each object. A 1200 mL water bottle was tested separately.
The toy-can and 600 mL bottle condition used a 0.1 A deadband, a 0.24 A current range and gain 0.6 applied to a cap of 40, giving a maximum commanded output limit of 24 raw servo units. The 1200 mL bottle condition used a 0.20 A current range and a cap of 40 raw units; its gain was not recorded. Results are analyzed separately because the controller settings differed.
We recorded follower joint currents, the empty-arm baseline, commanded leader-servo output limits and the feedback-active flag. A cue-activation interval is a continuous period during which this flag is active. The first condition contained three such intervals and the 1200 mL condition contained seven.
For each interval, we calculate the median signed shoulder-current change relative to the empty-arm baseline using valid active samples. The interval includes its start and excludes the cue-inactive sample at its end.
These measurements characterize feedback-command activation. Rendered joint torque and operator perception were not measured. Results are reported in Sec. 5.3.

Figure 4: Sent joint commands and measured UR3 angles. (a) Three joints during the selected 20 s window with the most commanded travel. (b) Zoom on the fastest motion of the most active joint in that window. The displayed command has already undergone leader offset alignment and smoothing.
5 Results
5.1 E1: Command tracking and timing
Same-time sent-command tracking error was 0.15–0.36° RMSE. After alignment by an estimated 82–98 ms trajectory lag, residual RMSE was 0.014–0.028° (Fig. 4, Table 3). Alignment measures agreement between interpolated command and measured trajectories. Physical leader accuracy has not been established at that scale. Median valid consecutive control intervals were approximately 16.65 ms, and the median recording-level rate was 57.6 Hz.
Median session-level leader-read and read-to-servoJ-return durations were 1.40 and 0.29 ms. These timings cover selected arm-command execution stages, leaving complete end-to-end latency unmeasured. The median host-observed motion-bracket midpoint was 56.6 ms, with median lower and upper endpoints of 48.3 and 65.0 ms. This midpoint is not an upper bound on an isolated command's response. Gripper message-receipt-to-send and send-to-acknowledgement stage medians were 13.4 and 10.1 ms. The logs cannot separate the contributions of controller dynamics, smoothing, transport and sampling to trajectory lag. Contact-to-trigger actuation latency was also unmeasured.
Table 3: Sent-command tracking over six sessions. Same-time RMSE pools samples; lag and aligned RMSE are medians over eligible joint-sessions (n). Software rows use available session medians: six for arm stages and three for gripper stages.
| Joint | Same-time RMSE (°) | Lag (ms) | Aligned RMSE (°) | n |
|---|---|---|---|---|
| Base | 0.18 | 84 | 0.014 | 3 |
| Shoulder | 0.19 | 98 | 0.017 | 3 |
| Elbow | 0.36 | 98 | 0.028 | 5 |
| Wrist 1 | 0.27 | 98 | 0.028 | 4 |
| Wrist 2 | 0.15 | 84 | 0.023 | 5 |
| Wrist 3 | 0.16 | 82 | 0.017 | 5 |
| Effective recording rate | 57.6 Hz | |||
| Leader read | 1.40 ms | |||
| Read end → servoJ return | 0.29 ms | |||
| Gripper receive → send | 13.4 ms | |||
| Gripper send → ACK | 10.1 ms | |||
| Motion-bracket midpoint (n=634) | 56.6 ms | |||
5.2 E2: Fragile-object grasping
Contact registration and hold behavior. We found logged tactile onset within the association window for 60 of 62 segmented TacGELLO intervals. The other two used width references in Table 4. The cup's first interval began already below the segmentation threshold. Without independent contact labels, we cannot classify it as a confirmed missed contact. One additional tactile-onset event occurred outside segmentation windows. Its status as a physical contact or false positive is unverified.
In 59 of the 60 tactile-referenced intervals, subsequent commanded closure was below 5 mm. The exception was a chip interval with 35.9 mm of subsequent commanded closure and duration 17.6 s. We retain this interval in the results; its cause is unknown from the logs. Across all 62 TacGELLO intervals, including the two width fallbacks, median commanded closure after the reference was 0.7, 2.1 and 0.7 mm for chip, cup and bottle.
Comparison of the complete interfaces. Original-interface median commanded closure after its width reference was 13.0, 13.5 and 13.9 mm. Peak trigger rotation and finger-servo closure were also larger in the original sessions (Table 4). These are measurements of commands and encoder motion. Grip force, object deformation, damage and successful lifting were not directly measured.
In the representative trace, the original command trails the trigger and TacGELLO holds near the tactile reference (Fig. 5). Command dynamics, contact references and session conditions differ between interfaces. The reported effect sizes describe those recordings, so the reduction cannot be attributed to tactile feedback alone.
Table 4: Exploratory grasp outcomes: median [Q1, Q3]. Original: feedback off, rate-limited commands; TacGELLO: tactile hold, direct commands. Outcome-specific sample sizes are given in each row. is Cliff's delta for TacGELLO minus original. Commanded closure uses different contact references across conditions.
| Object | Measure | Original | n | TacGELLO | n | δ |
|---|---|---|---|---|---|---|
| Chip | Commanded closure (mm) | 13.0 [8.0, 24.3] | 21 | 0.7 [0.0, 1.5] | 19 | -0.77 |
| Trigger rotation (°) | 31.0 [28.7, 35.9] | 23 | 26.6 [25.8, 27.9] | 19 | -0.62 | |
| Finger-servo closure (°) | 27.2 [26.0, 31.7] | 23 | 23.4 [23.0, 24.2] | 19 | -0.81 | |
| Cup | Commanded closure (mm) | 13.5 [6.7, 19.0] | 14 | 2.1 [1.4, 2.9] | 20 | -0.88 |
| Trigger rotation (°) | 20.0 [18.2, 23.0] | 17 | 16.9 [15.8, 18.3] | 20 | -0.49 | |
| Finger-servo closure (°) | 17.3 [15.6, 19.8] | 17 | 12.7 [11.7, 13.3] | 20 | -0.76 | |
| Bottle | Commanded closure (mm) | 13.9 [6.8, 27.6] | 21 | 0.7 [0.0, 1.4] | 23 | -0.90 |
| Trigger rotation (°) | 17.7 [15.3, 20.8] | 25 | 14.2 [13.6, 16.9] | 23 | -0.41 | |
| Finger-servo closure (°) | 15.7 [13.3, 18.7] | 24 | 11.6 [10.5, 13.7] | 23 | -0.67 |
5.3 E3: Arm-current feedback during lifting
We summarize the recorded shoulder-current changes and leader-servo output-limit commands for the two E3 conditions. These measurements characterize feedback-command activation; rendered joint torque and operator perception were not measured.
The alternating toy-can and 600 mL bottle condition contained three cue-activation intervals. Median signed shoulder-current changes relative to the empty-arm baseline were 0.528, 0.407 and 0.138 A, calculated from 123, 73 and 141 active samples, respectively. Peak commanded output limits were 24, 24 and 14 raw units. The configured maximum was reached in two intervals. Individual intervals were not reliably associated with the toy can or bottle, so these values are reported at the recording level.
The separate recording associated with the nominal 1200 mL bottle condition contained seven cue-activation intervals, comprising 286 active samples (Table 5). Median signed shoulder-current changes ranged from 0.110 to 0.572 A. Peak commanded output limits ranged from 4 to 40 raw units, reaching the configured cap in one interval.
The intervals identify periods of controller activity and do not establish the number of successful lifts. Bottle volume and total payload mass were not independently verified. Different controller settings and uncontrolled posture also prevent a matched comparison between payloads. The results therefore demonstrate recorded feedback-command activation without establishing load-proportional resistance or perceptible weight feedback.
6 Discussion and Limitations
TacGELLO uses existing leader servos to command fingertip-contact and arm-load cues. The grasping recordings showed lower commanded closure with TacGELLO, but feedback, command dynamics and contact references changed together. One operator performed one session per object-condition without randomized ordering. The original bottle calibration anomaly adds uncertainty to trigger comparisons. These differences prevent attributing the observed reduction to tactile feedback alone.
Table 5: Logged cue activations associated with the nominal 1200 mL bottle condition. n counts valid active samples. is the median signed shoulder-current change relative to the empty-arm baseline. Peak limits are logged output-limit commands in raw servo units.
| Cue | n | ΔI (A) | Peak limit |
|---|---|---|---|
| 1 | 38 | 0.572 | 27 |
| 2 | 25 | 0.287 | 10 |
| 3 | 134 | 0.280 | 40 |
| 4 | 29 | 0.422 | 29 |
| 5 | 25 | 0.144 | 10 |
| 6 | 9 | 0.110 | 5 |
| 7 | 26 | 0.158 | 4 |
The measurements characterize commands and encoder motion. Physical-contact accuracy, grasp outcomes, rendered joint torque and operator perception were not independently evaluated. Joint current also depends on posture and motion, and the load tests used different controller settings without independently verified payload masses. The arm results therefore support feedback-command activation, while load-proportional rendering remains unverified. Similarly, estimated trajectory lag does not measure complete contact-to-trigger latency.
A matched comparison should keep command dynamics and contact measurement identical while varying the trigger hold across randomized trials with additional operators. A contact-stop condition without trigger resistance would help distinguish automatic stopping from the contribution of the operator cue. Arm-feedback validation requires known masses at controlled poses, torque

Figure 5: Representative chip intervals selected near each interface's median minimum commanded width, with pre-window commanded width at least 125 mm and segment duration under 6 s. Traces are aligned to 0.6 s before each segmented interval. The TacGELLO marker is logged tactile onset; the original-interface marker is its width-based contact reference. The AnySkin trace is the norm of baseline-relative logged field magnitudes and has no force calibration.
calibration and operator assessments. Complete reproduction also requires the detector filtering settings and experimental arm-controller source. Evaluation remains limited to the tested UR3 setup and non-ferromagnetic objects.
7 Conclusion
We built TacGELLO to return fingertip contact to a 3D-printed UR3 leader through its existing trigger servo. A separate channel uses follower joint-current changes to provide an arm-resistance cue. Recordings from one operator characterize sent-command tracking and show lower commanded closure in a preliminary comparison with the original gripper interface. Command dynamics, contact references and session conditions also differed, leaving the effect of tactile feedback unresolved. A matched comparison with independent contact and grasp outcomes, together with calibration of the rendered cues, is needed to evaluate the mechanism's effectiveness.

Figure 6: Per-interval command and encoder measurements for the original interface (grey) and TacGELLO (blue). Contact-dependent values use tactile onset where available and a width reference otherwise, including two TacGELLO fallbacks. Conditions also differ in command dynamics. Points include the large chip outlier.
References
[Adachi et al., 2018] Tsuyoshi Adachi, Kazuki Fujimoto, Sho Sakaino, and Toshiaki Tsuji. Imitation learning for object manipulation based on position/force information using bilateral control. In IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2018.
[Adeniji et al., 2025] Ademi Adeniji, Zhuoran Chen, Vincent Liu, Venkatesh Pattabiraman, Raunaq Bhirangi, Siddhant Haldar, Pieter Abbeel, and Lerrel Pinto. Feel the force: Contact-driven learning from humans, 2025. arXiv:2506.01944.
[ALOHA 2 Team et al., 2024] ALOHA 2 Team, Jorge Aldaco, Travis Armstrong, Robert Baruch, Jeff Bingham, Sanky Chan, Kenneth Draper, Debidatta Dwibedi, Chelsea Finn, Pete Florence, Spencer Goodrich, Wayne Gramlich, Torr Hage, Alexander Herzog, Jonathan Hoech, Thinh Nguyen, Ian Storz, Baruch Tabanpour, Leila Takayama, Jonathan Tompson, Ayzaan Wahid, Ted Wahrburg, Sichun Xu, Sergey Yaroshenko, Kevin Zakka, and Tony Z. Zhao. ALOHA 2: An enhanced low-cost hardware for bi-manual teleoperation, 2024. arXiv:2405.02292.
[Bazhenov et al., 2025] Artem Bazhenov, Sergei Satsevich, Sergei Egorov, Farit Khabibullin, and Dzmitry
Tsetserukou. Echo: An open-source, low-cost teleoperation system with force feedback for dataset collection in robot learning, 2025. arXiv:2504.07939.
[Bhirangi et al., 2022] Raunaq Bhirangi, Tess Hellebrekers, Carmel Majidi, and Abhinav Gupta. ReSkin: Versatile, replaceable, lasting tactile skins. In Proceedings of the 5th Conference on Robot Learning, volume 164 of Proceedings of Machine Learning Research, pages 587–597, 2022. arXiv:2111.00071.
[Bhirangi et al., 2025] Raunaq Bhirangi, Venkatesh Pattabiraman, Enes Erciyes, Yifeng Cao, Tess Hellebrekers, and Lerrel Pinto. AnySkin: Plug-and-play skin sensing for robotic touch. In IEEE International Conference on Robotics and Automation (ICRA), 2025. arXiv:2409.08276.
[Buamanee et al., 2024] Thanpimon Buamanee, Masato Kobayashi, Yuki Uranishi, and Haruo Takemura. BiACT: Bilateral control-based imitation learning via action chunking with transformer. In IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM), 2024. arXiv:2401.17698.
[Chi et al., 2024] Cheng Chi, Zhenjia Xu, Chuer Pan, Eric Cousineau, Benjamin Burchfiel, Siyuan Feng, Russ Tedrake, and Shuran Song. Universal manipulation interface: In-the-wild robot teaching without in-the-wild robots. In Robotics: Science and Systems (RSS), 2024. arXiv:2402.10329.
[Cuan et al., 2024] Catie Cuan, Allison Okamura, and Mohi Khansari. Leveraging haptic feedback to improve data quality and quantity for deep imitation learning models. IEEE Transactions on Haptics, 17(4):984–991, 2024. arXiv:2211.03020.
[Fang et al., 2024] Hongjie Fang, Hao-Shu Fang, Yiming Wang, Jieji Ren, Jingjing Chen, Ruo Zhang, Weiming Wang, and Cewu Lu. AirExo: Low-cost exoskeletons for learning whole-arm manipulation in the wild. In IEEE International Conference on Robotics and Automation (ICRA), 2024. arXiv:2309.14975.
[He et al., 2025] Zihao He, Hongjie Fang, Jingjing Chen, Hao-Shu Fang, and Cewu Lu. FoAR: Force-aware reactive policy for contact-rich robotic manipulation. IEEE Robotics and Automation Letters, 2025. arXiv:2411.15753.
[Hokayem and Spong, 2006] Peter F. Hokayem and Mark W. Spong. Bilateral teleoperation: An historical survey. Automatica, 42(12):2035–2057, 2006.
[Hou et al., 2025] Yifan Hou, Zeyi Liu, Cheng Chi, Eric Cousineau, Naveen Kuppuswamy, Siyuan Feng, Benjamin Burchfiel, and Shuran Song. Adaptive compliance policy: Learning approximate compliance for
diffusion guided control. In IEEE International Conference on Robotics and Automation (ICRA), 2025. arXiv:2410.09309.
[Huang et al., 2024] Binghao Huang, Yixuan Wang, Xinyi Yang, Yiyue Luo, and Yunzhu Li. 3D-ViTac: Learning fine-grained manipulation with visuo-tactile sensing. In Conference on Robot Learning (CoRL), 2024. arXiv:2410.24091.
[Kanai et al., 2025] Yoshiki Kanai, Akira Kanazawa, Hideyuki Ichiwara, Hiroshi Ito, Naoaki Noguchi, and Tetsuya Ogata. Input-gated bilateral teleoperation: An easy-to-implement force feedback teleoperation method for low-cost hardware, 2025. arXiv:2509.08226.
[King et al., 2009] Chih-Hung King, M. O. Culjat, M. L. Franco, C. E. Lewis, E. P. Dutson, W. S. Grundfest, and J. W. Bisley. Tactile feedback induces reduced grasping force in robot-assisted surgery. IEEE Transactions on Haptics, 2(2):103–110, 2009.
[Kobayashi et al., 2025] Takumi Kobayashi, Masato Kobayashi, Thanpimon Buamanee, and Yuki Uranishi. Bi-LAT: Bilateral control-based imitation learning via natural language and action chunking with transformers, 2025. arXiv:2504.01301.
[Lawrence, 1993] Dale A. Lawrence. Stability and transparency in bilateral teleoperation. IEEE Transactions on Robotics and Automation, 9(5):624–637, 1993.
[Liu et al., 2025a] Jason Jingzhou Liu, Yulong Li, Kenneth Shaw, Tony Tao, Ruslan Salakhutdinov, and Deepak Pathak. FACTR: Force-attending curriculum training for contact-rich policy learning. In Robotics: Science and Systems (RSS), 2025. arXiv:2502.17432.
[Liu et al., 2025b] Wenhai Liu, Junbo Wang, Yiming Wang, Weiming Wang, and Cewu Lu. ForceMimic: Force-centric imitation learning with force-motion capture system for contact-rich manipulation. In IEEE International Conference on Robotics and Automation (ICRA), 2025. arXiv:2410.07554.
[Oh et al., 2026] Steven Oh, Jason Jingzhou Liu, Tony Tao, Philip Han, Kenneth Shaw, Satoshi Funabashi, Ruslan Salakhutdinov, and Deepak Pathak. FACTR 2: Learning external force sensing for commodity robot arms improves policy learning, 2026. arXiv:2606.12406.
[Pattabiraman et al., 2025] Venkatesh Pattabiraman, Zizhou Huang, Daniele Panozzo, Denis Zorin, Lerrel Pinto, and Raunaq Bhirangi. eFlesh: Highly customizable magnetic touch sensing using cut-cell microstructures, 2025. arXiv:2506.09994.
[Satsevich et al., 2025] S. Satsevich, A. Bazhenov, S. Egorov, A. Erkhov, M. Gromakov, A. Fedoseev, and D. Tsetserukou. Prometheus: Universal, open-source mocap-based teleoperation system with force feedback for dataset collection in robot learning, 2025. arXiv:2510.01023.
[Sujit et al., 2025] Shivakanth Sujit, Luca Nunziante, Dan Ogawa Lillrank, Rousslan Fernand Julien Dossa, and Kai Arulkumaran. Improving low-cost teleoperation: Augmenting GELLO with force. In IEEE/SICE International Symposium on System Integration (SII), 2025. arXiv:2507.13602.
[Wagner et al., 2007] Christopher R. Wagner, Nicholas Stylopoulos, Patrick G. Jackson, and Robert D. Howe. The benefit of force feedback in surgery: Examination of blunt dissection. Presence: Teleoperators and Virtual Environments, 16(3):252–262, 2007.
[Wildenbeest et al., 2013] J. G. W. Wildenbeest, D. A. Abbink, C. J. M. Heemskerk, F. C. T. van der Helm, and H. Boessenkool. The impact of haptic feedback quality on the performance of teleoperated assembly tasks. IEEE Transactions on Haptics, 6(2):242–252, 2013.
[Wu et al., 2024] Philipp Wu, Yide Shentu, Zhongke Yi, Xingyu Lin, and Pieter Abbeel. GELLO: A general, low-cost, and intuitive teleoperation framework for robot manipulators. In IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS), 2024. arXiv:2309.13037.
[Xue et al., 2025] Han Xue, Jieji Ren, Wendi Chen, Gu Zhang, Yuan Fang, Guoying Gu, Huazhe Xu, and Cewu Lu. Reactive diffusion policy: Slow-fast visual-tactile policy learning for contact-rich manipulation. In Robotics: Science and Systems (RSS), 2025. arXiv:2503.02881.
[Yamane et al., 2025] Koki Yamane, Yunhan Li, Masashi Konosu, Koki Inami, Junji Oaki, Sho Sakaino, and Toshiaki Tsuji. Fast bilateral teleoperation and imitation learning using sensorless force control via accurate dynamics model, 2025. arXiv:2507.06174v1.
[Zhang et al., 2025] Han Zhang, Songbo Hu, Zhecheng Yuan, and Huazhe Xu. DOGlove: Dexterous manipulation with a low-cost open-source haptic force feedback glove. In Robotics: Science and Systems (RSS), 2025. arXiv:2502.07730.
[Zhao et al., 2023] Tony Z. Zhao, Vikash Kumar, Sergey Levine, and Chelsea Finn. Learning fine-grained bimanual manipulation with low-cost hardware. In Robotics: Science and Systems (RSS), 2023. arXiv:2304.13705.