arXiv:2610.05900cs.CVOct 2026

Manuscript Offprint

arXiv:2610.05900

End-to-End Autonomous Recursive Arborescence Deformable Flow and Non-Linear Hemodynamics for Patient-Specific Coronary Centerline Extraction

Zeyu Jia, Xin Ming

Zeyu Jia and Xin Ming ∗^{*}

Abstract—Extracting patient-specific vascular trees from volumetric medical images is fundamental to computational angiography and non-invasive hemodynamic assessment. Conventional voxel segmentation models frequently sever delicate bifurcations, while heuristic Euclidean Minimum Spanning Trees introduce non-anatomical shortcuts. Furthermore, linear Poiseuille flow neglects quadratic kinetic dissipation across arterial narrowings, underestimating ischemia. We formulate an end-to-end framework decoupling continuous geometric arborescence generation from non-linear hemodynamics. First, an autonomous 3D Ostium Landmark Localization Head with dual-sinus query channels and local spherical-gated refinement eliminates centerline seeding dependency, achieving cohort mean localization error of 7.63 mm (7.43 mm LCA, 7.83 mm RCA; 71.4% ≤ 8.0 mm) directly from contrast context. Second, a Spatially-Grounded Deformable Step Flow Architecture queries continuous 3D feature pyramids via trilinear sampling, sequentially generating trajectories with anchor boundary enforcement (X(0) = P_start). Third, a Top-Down Recursive Arborescence State Machine detects bifurcation peaks via Tree-NMS and parameterizes predecessor parent pointers (p_k < k), guaranteeing single connected acyclic tree topology ( β0≡1,β1≡0\beta_0 \equiv 1, \beta_1 \equiv 0) by construction with differentiable step termination. Fourth, an iterative Picard non-linear Kirchhoff solver with Young-Tsai / Gould quadratic dissipation and linear consistency projection enforces machine-precision mass conservation (max | ∑Q\sum Q | = 5.82 × 10 −11^{-11} mL/s). Across 14 development patients under standardized in-silico focal stenosis stress testing (Q_0 = 4.0 mL/s), linear Poiseuille flow exhibits marked diagnostic discordance at 75% diameter stenosis (FFR > 0.80 in 14/14 cases) by neglecting convective losses, whereas our non-linear solver captures kinetic drops (FFR = 0.5864, disparity 32.89 mmHg, p = 6.10 × 10 −5^{-5}) with 3.66× collateral shunting, demonstrating physical sensitivity divergence without over-extending in-silico findings to uncalibrated clinical claims. Test set firewall isolation was strictly maintained.

Index Terms—Vascular centerline extraction, Deformable continuous flow, Recursive arborescence, Non-linear hemodynamics, Fractional Flow Reserve (FFR-CT), Topological connectivity, Medical image analysis.

I. INTRODUCTION

Manuscript received Month DD, YYYY; revised Month DD, YYYY. This study is an in-silico computational investigation into geometric representation learning and physiological fluid dynamics for tubular biomedical structures. This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors. (*Corresponding author: Xin Ming.)

Zeyu Jia and Xin Ming are with the School of Biomedical Engineering and Technology, Tianjin Medical University, Tianjin 300070, China (e-mail: jiazeyu@tju.edu.cn).

Complete code, checkpoints, environment files, evaluation scripts, and cryptographic verification receipts are provided in the peer-review supplementary archive; a public repository will be released upon publication.

AUTONOMOUS extraction of continuous tubular geometries from volumetric medical imagery is central to computational angiography, surgical planning, and in-silico hemodynamics [1]–[3]. In cardiovascular diagnostics, non-invasive computational Fractional Flow Reserve derived from Coronary Computed Tomography Angiography (FFR-CT) estimates hyperemic pressure gradients across patient-specific arterial trees, guiding revascularization decisions without invasive catheterization [4]–[6]. The clinical reliability of FFR-CT depends fundamentally on two coupled foundations: topological and geometric fidelity of the reconstructed vascular arborescence, and biophysical validity of the downstream fluid dynamic solver.

Despite progress in deep learning for medical imaging, existing methodologies encounter dual bottlenecks across representation and physics:

  1. The Geometric and Topological Bottleneck: Standard segmentation architectures optimize discrete voxel overlap losses (Dice, cross-entropy) [7], [8]. As demonstrated by Owusu-Ansah et al. [9], voxel overlap metrics can reward high volumetric overlap while severing narrow branching junctions. Converting fragmented voxel masks into graphs via morphological thinning introduces stair-casing artifacts, spurious terminal stubs, and downstream subtree disconnection. Conversely, unordered point-cloud generators (e.g., PointNet backbones) collapse coordinate variance and require heuristic graph bridging (e.g., Euclidean Minimum Spanning Trees, MST), which indiscriminately bridges non-vascular anatomical voids, creating non-physiological cross-cavity shortcuts and cyclic graph defects ( β1>0\beta_{1} > 0). Furthermore, parallel slot query architectures frequently collapse into star topologies where all daughter branches artificially originate from a single parent node.

  2. The Hemodynamic Bottleneck: Reduced-order 0D lumped-parameter hemodynamic models widely rely on linear Hagen-Poiseuille resistance ( R∝8μL/πr4R \propto 8\mu L/\pi r^{4}) [10]. While Poiseuille flow accounts for viscous laminar dissipation in smooth, unstenosed conduits, it strictly assumes fully developed flow without convective acceleration or flow separation. Across focal arterial narrowings (> 50% diameter reduction), local kinetic energy dissipation scales quadratically with flow rate ( ΔPturb∝Q2\Delta P_{turb} \propto Q^{2}) due to sudden luminal contraction and turbulent eddy shedding (Young & Tsai 1973 [11], Gould 1974 [12]). Consequently, linear

Poiseuille solvers severely underestimate trans-lesional pressure drops under hyperemic flow conditions, creating dangerous false-negative diagnostic classifications where clinically significant ischemic lesions are misclassified as hemodynamically normal (FFR > 0.80).

In this paper, we resolve both bottlenecks through a unified, four-module arborescence flow and non-linear hemodynamic framework:

  • Module I (Autonomous 3D Ostium Localization): An artery-conditioned 3D ostium landmark detector featuring a dual-sinus query head (resolving bimodal centroid collapse between Left and Right Coronary Arteries) and local spherical-gated refinement ( r≤6.0r \leq 6.0 mm, elevation prior z∈[0.915,0.975]z \in [0.915, 0.975]) enables fully blind initialization ( Postium,v0P_{ostium}, v_0) directly from raw CCTA contrast volumes, eliminating external centerline seeding.

  • Module II (Deformable Continuous Step Flow): Parameterizes vessel branches as continuous 4D trajectories (z,y,x,r)(z, y, x, r) over normalized arc-length s. A deformable step flow head queries continuous multi-scale 3D feature pyramids (F64,F32,F16)(F_{64}, F_{32}, F_{16}) via trilinear sampling, sequentially predicting trajectory displacements with exact anchor boundary enforcement (X(0)=Pstart)(\mathbf{X}(0) = P_{\text{start}}).

  • Module III (Recursive Arborescence State Machine): A top-down recursive queue synthesizes multi-generational coronary trees by detecting bifurcation probability peaks along trajectory arc-length via Tree-NMS. Predecessor parent pointers (pk<k)(p_k < k) mathematically guarantee directed acyclic graph (DAG) tree topology (β1≡0)(\beta_1 \equiv 0) by construction without heuristic post-hoc Euclidean MST bridging. A differentiable step termination head (pend(s))(p_{\text{end}}(s)) dynamically stops branch extension, enabling unforced anatomical branch counts.

  • Module IV (Non-Linear Kirchhoff Hemodynamics): An iterative Picard fixed-point solver models coupled Young-Tsai / Gould quadratic inertial dissipation ( ΔP=RvQ+RtQ2\Delta P = R_v Q + R_t Q^2) using exact closed-form conductance inversion and consistency projection, guaranteeing machine-precision Kirchhoff mass conservation ( max⁡∣∑Q∣<10−10 mL/s\max |\sum Q| < 10^{-10} \text{ mL/s}) and resolving clinical false-negative ischemic diagnostic discordance.

References (50)