arXiv:2610.06095cs.LGOct 2026

Manuscript Offprint

arXiv:2610.06095

Lossy Compression of PDE Training Inputs: Field Reconstruction Error Does Not Order the Cost to a Trained Operator

Huy Hoang Le

Abstract

Operator-learning benchmarks are stored at full precision and have grown to terabyte scale. Rate-distortion theory says how many bits the stored field needs, while a practitioner needs to know how accurate an operator trained on the compressed data will be. We show that the first does not determine the second, and measure why, compressing the input fields while targets and test inputs stay at full precision. A solution operator attenuates a perturbation of its input. Pushing a compressed field through a surrogate already trained at full precision measures how much of the perturbation that surrogate transmits. The fraction is consistent with the smoothing behaviour of the underlying equation, and it spans more than two orders of magnitude across PDE families. Field reconstruction error is computed before the attenuation and cannot see it. For operators trained with mean squared error it inverts 36 of 104 cost comparisons across datasets, where a probe built from the same forward passes inverts 12. Two families that PDEBench stores with identical initial conditions differ threefold downstream at identical field error. Under the relative- L2L^{2} objective of the reference recipe the separation narrows, while the ordering of the family-level median transmission factors is unchanged. After one full-precision training run, the probe evaluates an entire rate curve by forward passes alone. It ranks datasets and rates consistently across the codecs and architectures we test, while its magnitude does not transfer between them.

Keywords: operator learning, lossy compression, rate-distortion, scientific benchmarks, data quality

1 Introduction

Benchmarks for operator learning, such as PDEBench (Takamoto et al., 2022) and The Well (Ohana et al., 2024), are distributed as full-precision arrays and have grown to terabyte scale. The fields they contain are solutions of partial differential equations, so they are smooth or piecewise smooth and highly redundant, and compressing them looks like an easy saving.

For the stored field alone the question has a clean answer. Treating the dataset as a sample of a pushforward measure and applying rate-distortion theory to its covariance gives the number of bits per sample required to hold the field to a given accuracy. The PDE fixes the relevant spectrum through the smoothing order of its solution operator, and Section 2 verifies that this framework is accurate on the data used here.

The difficulty is that the framework describes the field, which is not what a practitioner cares about. What matters is the accuracy of the operator trained on the compressed data, and nothing in the framework relates the two. If field fidelity determines downstream accuracy, a tolerance can be chosen in advance from the dataset, as any tolerance set from field statistics assumes. If it does not, no theory of the field can answer the practical question.

©2026 Le Huy Hoang.

There is a reason to expect that it does not, and it is older than operator learning. Preserving an observation so as to preserve a downstream functional of it is the indirect source coding problem (Wolf and Ziv, 1970), in which the two distortions coincide only for a map that preserves the metric. A solution operator generally does not, so two datasets stored to the same field error can hand their operators perturbations of very different size. Section 2 makes this precise, and Section 4 measures the attenuation, which spans more than two orders of magnitude across PDE families. A tolerance set too tight leaves the archive larger than it needs to be, one set too loose leaves every model trained from it worse than its users can tell, and neither failure announces itself.

Figure 1 fixes the two quantities and where each is measured. Panel (a) follows one dataset through the pipeline: a full-precision array is compressed at some rate, an operator is trained on the compressed copy, and that operator is evaluated on full-precision inputs. Field reconstruction error lies entirely before training and is what rate-distortion theory predicts; downstream cost lies entirely after it and involves a training run; nothing forces the first to determine the second, and Section 4 shows it does not. Panel (b) is the alternative of Section 5: instead of training a model for every candidate rate, push the compressed input through one model already trained at full precision and measure how far its output moves.

(a) what is measured, and where

Figure

The paper measures whether the field error determines the downstream cost.

(b) the probe: one model already trained, then forward passes only

Figure

T is how far the output moves. No model is trained on A^\hat{A} to obtain it, so a whole rate curve costs one training run rather than one run per rate.

Figure 1: The two quantities the paper compares, and the probe that connects them. (a) Field error is measured before training, downstream cost after it. (b) The probe uses forward passes through one model trained at full precision, so an entire rate curve costs that single training run and no training on compressed data.

This paper measures the relationship. Our contributions are stated narrowly, in the form in which the measurements support them.

  1. A measurement of what a trained operator transmits. Pushing a compressed field through a surrogate already trained at full precision, and comparing the displacement at the output with the perturbation that went in, gives the fraction that surrogate transmits. The fraction is measured on the learned operator rather than on the true solution operator. The ordering of its family-level medians is consistent with the smoothing of each equation and is unchanged across three training objectives, and the fraction itself spans more than two orders of magnitude across our families. Measuring it needs no training beyond the one full-precision model and no baseline error, and it is what field error is computed too early to see (Section 4).

  2. The transmitted error provides a more reliable cross-family ordering of downstream cost than field error. We trained on compressed data at 16 configurations, all on one quantiser and with mean squared error. Across those points, field error inverts 36 of 104 across-family comparisons and a probe built from the transmitted error inverts 12, and the separation persists when any one family is removed. Retraining the same cells under two forms of relative L2L^{2} separates what is stable from what is not (Table 9). The ordering of the family-level median transmission factors is unchanged, and the probe never inverts the majority of comparisons between two families. Field error's misordering, in contrast, depends on the objective: it falls to 20 inversions against the probe's 11 under the reference objective, short of the twofold margin we pre-registered. Within a dataset field error remains reliable (Sections 4 and 5).

  3. What this buys a curator, and where it fails. The probe nominates a candidate rate for a small number of training runs to validate; checked against training, the nominated rate errs in both directions, by up to a factor of two in stored bits. Its ranking of datasets and rates holds across the three architectures and three codecs we test, while its magnitude is specific to each (Sections 5 and 6).

  4. A storage budget is not always better spent on samples. Walking a fixed budget from many coarsely stored fields to few precise ones, keeping the full training pool is the worst configuration on advection at a quarter of a bit per value and among the best on reaction-diffusion (Section 8).

  5. Negative results, reported. Seven candidate explanations are refuted, each with the measurement that refutes it, and a defect in our own quantiser changed a number we had attributed to the data. Of 38 bars pre-registered before the runs that scored them, 15 were missed, including both bars that required the separation to survive a change of training objective (Sections 9, 10 and 14).

The thesis these results support is that transmission is the more stable object. The ordering of the family-level median transmission factors survives every change of training objective we made, while the strength of the relationship between field error and downstream cost changes with it. This concerns anyone choosing a storage format for a simulation benchmark or setting a compression tolerance from field statistics.

References (23)