arXiv:2610.06177cs.AIOct 2026

Manuscript Offprint

arXiv:2610.06177

Auditable Clinical Timeline Reconstruction with Provenance-Aware Evidence Graphs

Judith Jeyafreeda Andrew

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Abstract

Longitudinal clinical evidence is spread across notes and can be revised as new results arrive. A system that reconstructs a patient timeline is auditable only if it keeps the mentions behind each answer, records how facts were revised, and declines to answer when the evidence is not in the text. This study builds and tests these three properties in a fully synthetic setting (1,000 patients, 3,353 notes, 2,220 clinical facts, 220 revision edges). Two provenance-aware Evidence Graph operators reduced the node-plus-edge count to 67% and 63% of the uncompressed graph (77% and 78% of its serialized size) while preserving every answer and mention link across 6,813 sampled query points, all of which were answerable by recency; a fixed-window baseline reached 58% of the size but returned no value for 53.4% of points and a wrong value for 1.2%, none flagged. Evidence-availability abstention was tested with two kinds of control. On controls carrying an explicit marker of omission, a BioClinicalBERT gate and a zero-shot large language model (LLM) gate both responded mainly to the marker: appending an omission notice to an otherwise unchanged note cut answering from 100% to 3.4% for BERT and from 58.9% to 0% for the LLM. Marker-free controls removed the temporal evidence with no notice, paired with a minimal rewrite by the same editor that preserved it. BERT abstained on 0 of 81 such notes while its accuracy on them fell from 93.8% to 59.3%; the drop occurred in all three relation classes and was not explained by the edit's reordering of event mentions. The LLM showed partial, marker-independent sensitivity: coverage fell from 75.6% to 27.7% on notes from which neither a cue filter nor the same model acting as judge could recover the relation. Against 482 gold evidence spans regenerated after paraphrasing, the LLM's cited spans reached recall 0.850 and precision 0.864 on answered notes, whereas BERT's evidence head, which received no span supervision, did not localize evidence (token-overlap recall 0.049 ungated, 0.006 gated). A temporally versioned provenance graph stored abstentions as typed, queryable edges with their reasons. The clean relation task admits a no-learning shortcut (0.651 accuracy), and all results describe implementation behaviour on synthetic data, not clinical performance or utility.

Keywords: temporal relation extraction; provenance; selective prediction; abstention; evidence graph; auditability; synthetic clinical text

1 Introduction

Longitudinal clinical information is spread across documents written at different times and for different purposes. A later culture result, imaging study, specialist assessment or treatment response can revise an earlier working diagnosis or treatment plan. A system that reports only the current answer hides this history: a reviewer cannot tell which mentions support the answer, when they were written, what they replaced, or whether the system had enough text to answer in the first place. Temporal relation extraction from clinical narratives remains difficult and depends on purpose-built annotated corpora [1].

Auditability is treated here as three concrete properties of a timeline-reconstruction pipeline. First, the compressed representation keeps revision history and mention links, so that an answer to “which fact was active on day dd” can be traced to the notes it came from. Second, the extractor declines to answer when the text does not contain the evidence, instead of returning a relation drawn from priors or surface regularities. Third, declines are stored in the same versioned graph as answers, with their reason, so that a withheld answer can be told apart from a missing value. The pipeline builds on provenance tracking from database theory [2] and on selective classification [3, 4].

This is a synthetic mechanism-validation study, not a clinical performance evaluation. A synthetic corpus gives what the three properties need and real corpora do not provide: a known revision structure, known injection sites for contradictions, and the ability to remove evidence from a note under control. An earlier version of the pipeline gave strong compression results but an evidence-span recall of 0.000 in every extraction configuration. That value traced back to an evaluation defect: gold spans had been recorded before the notes were paraphrased and were searched for by exact match, so the metric could not say whether the gates were finding the right evidence. Two independent checks were therefore added. Gold spans were regenerated against the paraphrased text, and the gates were scored on inputs from which the relation-bearing evidence had been removed, where the correct behaviour is to abstain. The way those evidence-unavailable inputs are built turned out to decide how far the results can be read. The first control set announces the removal with a fixed sentence, an appended notice or a mask token, so a gate can pass it by reading the announcement. A second, marker-free set removes the evidence silently and is paired with a minimal rewrite that keeps it (Sections 2.3 and 2.4).

The contributions are:

• Provenance-aware Evidence Graph operators that reduce representation size while preserving as-of queries and mention retention, evaluated against a fixed-window baseline and a generator-derived oracle, with size reported both as a node-plus-edge count and as serialized bytes.

  • An evidence-availability evaluation of two gate families, BioClinicalBERT and a zero-shot LLM, on marker-carrying and marker-free evidence-unavailable inputs, with metrics that separate clean coverage, abstention recall and answers given on unavailable evidence, and with each control paired with its clean note.

  • A temporally versioned provenance graph in which abstention is a first-class edge type, demonstrated on gated and ungated outputs of one model.

  • A documented list of failure modes: the invalid span-recall metric, gate over-abstention, an unattainable certification threshold, a template shortcut in the clean relation task, and explicit omission markers in the control inputs.

The study addresses three questions.

  1. Do provenance-aware graph operators preserve answers and mention retention under compression?

  2. Do evidence gates abstain when the evidence has been removed, both when the removal is announced and when it is not, and what does this cost on clean inputs?

  3. Can a temporally versioned provenance graph store abstentions as first-class, queryable edges alongside answers?

No claim is made about performance on real clinical records.