arXiv:2610.06221cs.CVOct 2026

Manuscript Offprint

arXiv:2610.06221

Frequency-Decoupled Diffusion Guidance for Non-Blind Image Deblurring

Sihan Wang, Jinshu Huang, Haibin Su, Yunhua Xue

Abstract

Pretrained diffusion models provide powerful image priors for training-free posterior sampling in image restoration. To guide this sampling process, frequency-aware methods progressively incorporate measurement information across frequency bands, facilitating coarse-to-fine reconstruction. However, existing methods typically do not explicitly separate frequency activation from degradation-induced attenuation, leaving attenuation differences among inactive frequencies insufficiently modeled. In this work, we propose frequency-decoupled posterior guidance to separate frequency activation from attenuation-aware spectral regularization. Specifically, a progressive low-to-high frequency schedule determines the active measurement band, while a kernel-derived attenuation map defines a selective spectral prior over inactive components. To stabilize the sampling process, we also introduce a local trajectory regularizer that suppresses spatially irregular state-to-clean deviations. For a fixed endpoint energy, we provide a KL-regularized path-space interpretation. In practice, we construct time-dependent guidance through local energy corrections using a Tweedie plug-in approximation. Experiments on natural-image benchmarks demonstrate strong PSNR and SSIM performance across challenging non-blind deblurring settings, even at higher measurement noise levels.

1 INTRODUCTION

Image restoration aims to recover a clean image from incomplete or corrupted measurements. A broad class of restoration tasks takes the form

y=Ax0+n,n∼N(0,σy2Im),(1)\mathrm{y}=\mathrm{A}\mathrm{x}_{0}+\mathrm{n},\qquad\mathrm{n}\sim\mathcal{N}\big(0,\sigma_{\mathrm{y}}^{2}\mathrm{I}_{m}\big), \tag{1}

where x0∈Rdx_0 \in \mathbb{R}^d is the unknown image, y∈Rmy \in \mathbb{R}^m is the observation, and A:Rd→RmA : \mathbb{R}^d \to \mathbb{R}^m is a known linear operator. Recovering x0x_0 is generally ill-posed because operator A may attenuate or discard part of the image information. Effective restoration must therefore balance measurement fidelity with image priors.

Classical methods design the prior through handcrafted regularizers, while more recent approaches use learned denoisers or energy models (Rudin et al., 1992; Cai et al., 2012; Glowinski et al., 2017; Su and Huang, 2026; Roth and Black, 2005; Venkatakrishnan et al., 2013; Dong et al., 2015). Diffusion models provide an expressive alternative by learning the score fields of progressively perturbed data distributions (Ho et al., 2020; Song et al., 2021; Huang et al., 2026). Conditional diffusion models can learn a direct degraded-to-clean mapping, but typically require paired data and task-specific training (Saharia et al., 2022; Whang et al., 2022). Zero-shot methods instead combine a pretrained unconditional diffusion model with the known forward operator at inference time (Kawar et al., 2022; Song et al., 2023; Wang et al., 2023; Chung et al., 2023; Zhu et al., 2023). This decoupling of the image prior from the observation model enables one pretrained model to address multiple inverse problems without retraining.

Despite this flexibility, existing zero-shot methods commonly enforce measurement consistency through spatial residuals, pseudoinverse projections, or likelihood gradients (Kawar et al., 2022; Wang et al., 2023; Chung et al., 2023; Meng and Kabashima, 2025). For natural images, diffusion denoising often recovers coarse structure before fine detail (Falck et al., 2025). This behavior has motivated frequency-aware

†^{\dagger}Equal contribution (wangsihan@mail.nankai.edu.cn; huangjsh@mail.nankai.edu.cn).

∗^{*}Corresponding author.

guidance, which progressively incorporates measurement information across frequency bands. FGPS follows this principle by gradually exposing measurement frequencies (Thaker et al., 2025); noise-conditioned posterior continuation further couples frequency activation to the diffusion noise level (Tian et al., 2026). However, existing frequency-aware methods typically do not explicitly separate frequency activation from degradation-induced attenuation, leaving attenuation differences among inactive frequencies insufficiently modeled. This distinction matters for directional or frequency-selective blur, where frequencies at similar spatial scales can have substantially different responses.

Motivated by these observations, we propose frequency-decoupled posterior guidance for non-blind image deblurring. By decoupling frequency activation from attenuation-aware regularization, our approach enables more precise incorporation of measurement information, effectively preventing highly attenuated or noisy frequencies from corrupting the update direction. Meanwhile, it better models inactive components by preventing the diffusion prior from introducing hallucination artifacts in spectral regions where measurement data is absent or severely degraded. Additionally, we introduce a local trajectory-stabilization regularizer that penalizes spatially irregular state-to-clean deviations, thereby promoting stable and spatially coherent sampling. Our main contributions are summarized as follows:

  • We introduce frequency-decoupled diffusion guidance for non-blind image deblurring. It is realized via a progressive schedule that determines which measurement frequencies are active at each reverse step, along with a kernel-derived attenuation map that defines a selective spectral prior over inactive components.

  • We formulate these components in a time-dependent guidance energy and derive practical stepwise corrections using a Tweedie plug-in approximation. To stabilize the updates, we introduce a local trajectory regularizer that suppresses spatially irregular state-to-clean deviations. For a fixed endpoint energy, we also provide a KL/Gibbs path-space interpretation.

  • We evaluate the proposed framework on natural-image benchmarks across challenging non-blind deblurring settings. The method achieves strong PSNR and SSIM performance and remains robust as measurement noise increases. Controlled ablations clarify the roles of the individual components and identify trajectory stabilization as a key contributor to the observed improvements.