Abstract—Large longitudinal cohorts often contain wrist accelerometry without optical heart-rate sensing, motivating recovery of cardiac information from motion signals already collected during sleep. We present SeqSmoother, a Transformer-based temporal corrector for sleep heart-rate (HR) estimation from wrist accelerometry. SeqSmoother combines spectral descriptors with an intermediate Nightbeat-derived frequency anchor and a physics-motivated sub-harmonic feature designed to identify harmonic frequency lock-on. All inference-time features are derived from wrist accelerometry, while ECG is used only to construct reference HR labels and training-label quality weights. We evaluate SeqSmoother using 13 participant-disjoint held-out folds and compare it with the official Nightbeat implementation under a matched 60-s window and 15-s step protocol. Across all out-of-fold predictions, SeqSmoother achieved a participant-macro MAE of 1.60 bpm. On Nightbeat-retained matched intervals, Nightbeat achieved lower absolute error than SeqSmoother (0.615 versus 1.091 bpm), while SeqSmoother provided estimates over a larger portion of the eligible recording; Nightbeat produced final estimates for 72.85% of the SeqSmoother-eligible out-of-fold grid. Separately, the proposed sub-harmonic ratio achieved an AUROC of 0.972 for identifying reference-defined harmonic lock-on candidates. These findings reveal an accuracy–availability trade-off between learned temporal modeling and quality-gated signal processing while providing empirical support for a physics-informed approach to identifying frequency-tracking failures in accelerometer-based sleep HR estimation.

Index Terms—heart rate estimation, ballistocardiogram, accelerometer, deep learning, sleep monitoring, wearable sensors, harmonic lock-on.

I. INTRODUCTION

Wrist-worn accelerometers are widely used in large longitudinal health studies to record physical activity and sleep. The U.K. Biobank [1], for example, collected week-long wrist accelerometry from roughly 100,000 participants. Such cohorts often contain rich longitudinal health records but no continuous optical heart-rate (HR) channel. Recovering HR from accelerometry already available in these cohorts could therefore provide an additional physiological signal for future retrospective analyses, provided that the reconstruction method is first validated against a suitable cardiac reference.

The mechanical recoil of each heartbeat produces the ballistocardiogram (BCG), a vibration measurable by accelerometers [2], [3]. At the wrist, this signal can be overwhelmed by voluntary motion, whereas sleep provides longer periods with relatively little movement [4], [5]. Earlier wrist approaches either relied on movement-free periods or required stronger external reference information [5], [6]. More recently, Nightbeat [7] combined frequency-domain tracking, motion-artifact rejection, and fixed temporal post-processing to obtain strong HR estimation on uncontrolled at-home sleep recordings.

Nightbeat therefore provides a demanding signal-processing (SP) baseline. Rather than asking whether a learned model should replace such a pipeline, we investigate whether learned temporal modeling can provide complementary behavior. We present SeqSmoother, a Transformer-based temporal corrector that uses a Nightbeat-derived frequency estimate as an anchor together with spectral and temporal information from wrist accelerometry. SeqSmoother also incorporates a physics-motivated sub-harmonic ratio designed to identify frequency-tracker lock-on near twice the true cardiac fundamental.

The evaluation treats the participant as the independent statistical unit. SeqSmoother is evaluated on 13 participant-disjoint held-out folds, and the official Nightbeat implementation is re-evaluated under a matched 60-s/15-s temporal protocol. The results show that Nightbeat achieves lower absolute error on intervals retained by its quality-control pipeline, whereas SeqSmoother provides predictions over a broader portion of the eligible recording. Separately, we evaluate the proposed sub-harmonic ratio against reference-defined harmonic lock-on events. We therefore interpret the findings as an accuracy–availability trade-off between learned temporal modeling and quality-gated signal processing, together with empirical support for a physics-informed diagnostic of frequency-tracking failures.

Contributions. This paper makes three contributions:

  1. We develop SeqSmoother, a Transformer-based temporal corrector for accelerometer-only sleep HR estimation that combines a Nightbeat-derived frequency anchor with spectral and temporal features from wrist accelerometry.

  2. We introduce a physics-motivated sub-harmonic ratio η1/2\eta_{1/2} for identifying harmonic frequency lock-on and empirically validate it using a pooled reference-based diagnostic, achieving an AUROC of 0.972 across 337 candidate lock-on windows from 7 held-out participants.

  3. We provide a participant-level matched comparison between SeqSmoother and the official Nightbeat implementation, including participant bootstrap uncertainty, paired testing, within-participant-centered correlation, and explicit alignment, retention, and prediction-availability analysis.