Manuscript Offprint

arXiv:2610.02497

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu, Phuc Nguyen, Jian Liu

TIANHAO WU, University of Georgia, United States

XU WU, University of Oklahoma, United States

AMIRMOHAMMAD RADMEHR, University of Massachusetts Amherst, United States

JIAWEI YU, University of Georgia, United States

YI WU, University of Oklahoma, United States

PHUC NGUYEN, University of Massachusetts Amherst, United States

JIAN LIU, University of Georgia, United States

The variability of Electromyography (EMG) signals across individuals, body regions, recording sessions, and sensing hardware creates a major barrier to developing general-purpose models for assistive devices and human-computer interaction. Although large time-series foundation models promise improved generalization, their substantial computational cost makes them difficult to deploy in real-time wearable settings. Moreover, EMG sensing introduces domain-specific constraints, such as characteristic frequency bands and the need for time-frequency representations, whereas existing foundation models typically operate on raw waveforms and therefore fail to capture these modality-specific properties. This paper introduces LITEEMG-FM, an efficient hybrid CNN-Transformer FM designed specifically for practical EMG signal processing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LITEEMG-FM learns robust representations that generalize across users and datasets while explicitly capturing EMG-specific signal characteristics. To demonstrate practical deployability, we implement a hierarchical wake-up architecture on a resource-constrained edge device, where a lightweight, always-on 1D-CNN gate filters rest and non-target activity, activating LITEEMG-FM only for valid gestures to reduce unnecessary computation. We further evaluate three deployment paradigms, including Full Inference Offloading, Split Inference, and Full On-Device Processing, to characterize trade-offs in latency, power consumption, and memory footprint. We conduct extensive experiments across diverse evaluation settings, and the results show that LITEEMG-FM consistently outperforms state-of-the-art time-series foundation models and supervised baselines, delivering superior reliability under zero-calibration cross-participant and data-scarce conditions. These results establish LITEEMG-FM as an effective, efficient, and deployable FM for next-generation EMG applications.

1 Introduction

Surface electromyography (sEMG), hereafter referred to as EMG, has emerged as a key sensing modality for mobile and wearable systems, enabling applications such as real-time prosthetic control, adaptive rehabilitation, silent-speech interfaces, and immersive augmented and virtual reality (AR/VR) interaction [1–5]. For these systems to operate reliably outside controlled laboratory settings, the underlying EMG models must generalize across users, body locations, recording sessions, and sensing hardware, while also meeting the strict latency, memory, and energy constraints of on-device inference. Recent commercial breakthroughs, such as Meta’s Neural Band [6], illustrate the transition of EMG from clinical laboratories to general-purpose human-computer interaction. However, for the broader landscape of wearable EMG, widespread adoption faces a critical gap for hardware constraints and model complexity. While the

Authors' Contact Information: Tianhao Wu, Tianhao.Wu1@uga.edu, University of Georgia, Athens, Georgia, United States; Xu Wu, xu.wu-1@ou.edu, Computer Science, University of Oklahoma, Norman, Oklahoma, United States; Amirmohammad Radmehr, aradmehr@umass.edu, Wireless and Sensor Systems Lab (WSSL), University of Massachusetts Amherst, Amherst, Massachusetts, United States; Jiawei Yu, University of Georgia, Athens, Georgia, United States; Yi Wu, University of Oklahoma, Norman, Oklahoma, United States; Phuc Nguyen, phuc@umass.edu, Manning College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, Massachusetts, United States; Jian Liu, jianliu@uga.edu, University of Georgia, Athens, Georgia, United States.

Wu et al.

Figure

Fig. 1. LITEEMG-FM: the first EMG foundation model explicitly designed to balance strong generalization with wearable deployment constraints.

sensors are capable, current deep learning models are either too computationally heavy for all-day battery life [7] or too brittle to generalize across diverse users without tedious per-user calibration [8, 9].

This lack of robustness stems from the high-dimensional variability of EMG signals. EMG signals exhibits substantial variability arising from electrode placement, skin impedance, muscle fatigue, and inter-subject physiological differences [10]. Such factors introduce pronounced nonstationarity across users, sessions, and sensing setups, causing conventional supervised models, typically trained on small, homogeneous datasets, to degrade rapidly when deployed in real-world conditions [11–13]. These challenges have motivated growing interest in time-series foundation models: large, self-supervised models pretrained on diverse datasets that aim to learn transferable representations capable of generalizing beyond narrow training distributions [14–16].

Despite this promise, existing time-series foundation models remain poorly suited for practical EMG sensing. First, most operate directly on raw time-domain waveforms (e.g., [17, 18]), neglecting EMG-specific characteristics such as modality-dependent frequency bands and transient muscle activation patterns. This design choice limits their ability to capture the nonstationary time-frequency structure which critical for fine-grained gesture recognition. Second, state-of-the-art time-series foundation models often contain hundreds of millions of parameters [19, 20], rendering them infeasible for real-time inference on mobile processors or microcontroller-class wearable devices. Third, these models are designed for broad, heterogeneous time-series domains, rather than addressing the unique noise properties, cross-body variability, and long-term nonstationarity inherent to EMG signals [21, 22]. Together, these limitations create a significant gap between the capabilities of current foundation models and the practical requirements of always-on mobile EMG systems: strong cross-domain generalization coupled with compute-aware deployability.

Motivated by the aforementioned gap, this paper introduces LITEEMG-FM, a compact, EMG-specific foundation model designed to jointly achieve strong cross-domain generalization and compute-aware deployability. Rather than relying on scale or domain-agnostic pretraining, LITEEMG-FM embeds inductive biases tailored to EMG physiology and sensing characteristics. Concretely, it transforms raw EMG signals into time-frequency spectrograms and adopts a two-stage architecture: a lightweight convolutional front-end that captures localized spectral activation patterns, followed by a compact Transformer that models long-range temporal dynamics. This design mirrors how muscle activity concentrates in characteristic frequency bands and evolves over time, enabling LITEEMG-FM to learn transferable, EMG-specific representations without the overhead of large, generic time-series foundations. As a result, LITEEMG-FM bridges robustness and efficiency, delivering state-of-the-art performance while remaining suitable for deployment on resource-constrained wearable hardware.

We pretrain LITEEMG-FM on 16 heterogeneous EMG datasets spanning both upper- and lower-limb activities, explicitly targeting the learning of representations that generalize across users, sensing locations, and recording conditions. We evaluate the pretrained model on five downstream tasks designed to stress generalization, including cross-user transfer, zero-calibration deployment, and data-scarce adaptation. Despite containing only ~8M parameters, LITEEMG-FM consistently outperforms conventional supervised models and modern time-series foundation models across all these settings. Notably, LITEEMG-FM surpasses large-scale time-series foundation models such as MOMENT-Large [17] (~385M parameters) and Brant [18] (~508M parameters) in every evaluation scenario, despite being over an order of magnitude smaller. These results demonstrate that EMG-specific pretraining and architectural inductive biases enable stronger and more reliable generalization than simply scaling model capacity. However, strong representational performance alone is insufficient for practical EMG systems, which must also operate under tight constraints on latency, power, and memory in real-world wearable deployments.

Moving beyond architectural considerations, we focus on system-level efficiency and deployment flexibility that determine practical viability. Figure 1 provides a high-level overview of deployment options for foundation models in EMG sensing systems. In typical settings, a wearable EMG device operates in conjunction with a nearby computing node, such as a smartphone, local edge server, or cloud backend, enabling flexible partitioning of sensing, feature extraction, and inference across devices. To support real-world deployment on resource-constrained hardware (e.g., ESP32-S3), we introduce a system-aware deployment framework centered on two key strategies. First, to reduce energy waste during inactivity, we implement a hierarchical wake-up architecture. A lightweight, always-on 1D-CNN binary activity detector processes raw EMG signals locally, filtering out rest intervals and non-target movements. By operating on raw data, this detector bypasses the computational overhead of time-frequency conversion, triggering the main foundation model only upon detecting valid gestural intent. Second, recognizing that optimal deployment depends on varying battery and network conditions, we systematically analyze three distinct inference deployment paradigms: (1) Full Inference Offloading, where the wearable streams raw EMG signals to a host that executes the entire inference pipeline; (2) Split Inference, where the wearable runs the CNN encoder to extract compact embeddings, which are transmitted to a host for Transformer inference; and (3) Full On-Device Processing, where both CNN and Transformer components run entirely on the wearable. By theoretically modeling and quantitatively measuring the trade-offs between latency, power, and memory for each scenario, we provide actionable guidelines for deploying EMG foundation models across the continuum of edge-cloud computing. In summary, this paper makes the following contributions:

• An Efficient and Deployable EMG foundation model: We introduce LITEEMG-FM, the first EMG foundation model explicitly designed to balance strong generalization with wearable deployment constraints. LITEEMG-FM is a compact 8M-parameter CNN-Transformer that leverages EMG-specific time-frequency representations, enabling robust cross-domain generalization while remaining deployable on microcontroller-class hardware, a capability absent in prior EMG and time-series foundation models.

• Large-Scale Heterogeneous EMG Pretraining Corpus: We curate and unify 16 diverse EMG datasets 1^{1} spanning both upper-limb (hand gestures) and lower-limb (locomotion) activities, representing the first comprehensive multi-domain EMG benchmark for foundation model training. We demonstrate that pretraining on this heterogeneous corpus enables robust representations that transfer effectively across users, body regions, and sensing configurations.

1^{1}All unified EMG datasets, preprocessing scripts, and pretrained LITEEMG-FM model will be released publicly upon paper acceptance.

Wu et al.

• Generalization over Scale: Accuracy, Efficiency, and Robustness: Across five downstream tasks, LITEEMG-FM consistently outperforms supervised baselines and state-of-the-art time-series foundation models under supervised fine-tuning, zero-calibration cross-participant evaluation, and extreme data scarcity (5% labels). Despite being orders of magnitude smaller, LITEEMG-FM achieves up to 24-29% higher accuracy than large foundation models and up to 58% gains over supervised baselines, demonstrating the advantages of EMG-specific design over brute-force scaling.

• System-Aware Deployment Framework with Practical Guidelines: We propose a system-aware deployment framework that combines a hierarchical wake-up strategy with an analysis of three inference paradigms across heterogeneous execution platforms: Full Inference Offloading, Split Inference, and Full On-Device Processing. Through theoretical modeling and measurements on ESP32-S3 hardware, we characterize latency, power, and memory trade-offs, providing actionable guidance for EMG deployment under varying battery and network conditions.

References (87)

  • Electromyography monitoring systems in rehabilitation: A review of clinical applications, wearable devices and signal acquisition methodologies
  • Emg-driven control in lower limb prostheses: A topic-based systematic review
  • Silent speech interfaces for speech restoration: A review
  • Force-aware interface via electromyography for natural vr/ar interaction
  • A review on emg/eeg based control scheme of upper limb rehabilitation robots for stroke patients
  • A generic non-invasive neuromotor interface for human-computer interaction
  • Hardware-software co-design architecture for real-time emg feature processing in fpga-based prosthetic systems
  • emg2qwerty: A large dataset with baselines for touch typing using surface electromyography
  • Emg-based multi-user hand gesture classification via unsupervised transfer learning using unknown calibration gestures
  • Gesture recognition by instantaneous surface emg images
  • Long short-term memory (lstm) recurrent neural network for muscle activity detection
  • Reducing noise, artifacts and interference in single-channel emg signals: a review
  • Detecting domain shifts in myoelectric activations: Challenges and opportunities in stream learning (opens arXiv in a new tab)
  • On the Opportunities and Risks of Foundation Models
  • Large-scale training of foundation models for wearable biosignals (opens arXiv in a new tab)
  • Moment: A family of open time-series foundation models (opens arXiv in a new tab)
  • Brant: Foundation model for intracranial neural signal
  • Time-LLM: Time Series Forecasting by Reprogramming Large Language Models
  • Power general time series analysis by pretrained lm
  • Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use
  • Deep learning for electromyographic hand gesture signal classification using transfer learning
  • Muscleio: Muscle-based input and output for casual notifications
  • A framework for hand gesture recognition based on accelerometer and emg sensors
  • Hand gesture recognition using compact cnn via surface electromyography signals
  • Waveformer: A lightweight transformer model for semg-based gesture recognition (opens arXiv in a new tab)
  • A multi-stream convolutional neural network for semg-based gesture recognition in muscle-computer interface
  • Temporal dilation of deep lstm for agile decoding of semg: Application in prediction of upper-limb motor intention in neurorobotics
  • Lstm recurrent neural network for hand gesture recognition using emg signals
  • Surface emg-based hand gesture recognition via hybrid and dilated deep neural network architectures for neurorobotic prostheses
  • A novel attention-based hybrid cnn-rnn architecture for semg-based gesture recognition
  • semg-based gesture recognition with convolution neural networks
  • Advances in neural information processing systems, 33:1877–1901, 2020
  • Bert: Pre-training of deep bidirectional transformers for language understanding
  • IEEE/ACM Transactions on Audio, Speech, and Language Processing, 32:2884–2899, 2024
  • Learning the language of time series (opens arXiv in a new tab)
  • Towards foundation models for time series forecasting
  • Towards customizable foundation models for human activity recognition with wearable devices
  • A decoder-only foundation model for time-series forecasting
  • Ecgbert: Understanding hidden language of ecgs with self-supervised representation learning (opens arXiv in a new tab)
  • Neuro-gpt: Towards a foundation model for eeg
  • Biot: Biosignal transformer for cross-data learning in the wild
  • Gpt-ppg: a gpt-based foundation model for photoplethysmography signals
  • A Time Series is Worth 64 Words: Long-term Forecasting with Transformers
  • Emg pattern recognition in the era of big data and deep learning
  • Techniques of emg signal analysis: detection, processing, classification and applications
  • Neuronal coordination of arm and leg movements during human locomotion
  • Time-frequency representations of brain oscillations: which one is better? Frontiers in Neuroinformatics, 16:871904, 2022
  • Time-frequency representation and convolutional neural network-based emotion recognition
  • Electromyography data for non-invasive naturally-controlled robotic hand prostheses
  • Resolving the limb position effect in myoelectric pattern recognition
  • The extraction of neural information from the surface emg for the control of upper-limb prostheses: emerging avenues and challenges
  • Innervation zones of the upper and lower limb muscles estimated by using multichannel surface emg
  • Long-term activity in upper-and lower-limb muscles of humans
  • The optimal controller delay for myoelectric prostheses
  • Challenges and direction (opens arXiv in a new tab)
  • Sentence-level energy optimizations for latency-aware multi-task nlp inference
  • Tiny deep learning on iot devices
  • Surface emg decoding for hand gestures based on spectrogram and cnn-lstm
  • Emg based hand gesture recognition using deep learning
  • Short latency hand movement classification based on surface emg spectrogram with pca
  • An efficient polyphase filter-based resampling method for unifying the prfs in sar data
  • Standardizing emg pipelines for muscle synergy analysis: A large-scale evaluation of filtering, normalization and criteria
  • An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
  • Coatnet: Marrying convolution and attention for all data sizes
  • Early convolutions help transformers see better
  • MobileViT: Light-weight, General-purpose, and Mobile-friendly Vision Transformer
  • Crossl: Cross-modal self-supervised learning for time-series through latent masking
  • Frequency-aware masked autoencoders for multimodal pretraining on biosignals (opens arXiv in a new tab)
  • Decoupled Weight Decay Regularization
  • Comparison of six electromyography acquisition setups on hand movement classification tasks
  • Improved prosthetic hand control with concurrent use of myoelectric and inertial measurements
  • Repeatability of grasp recognition for robotic hand prosthesis control based on semg data
  • Effect of user practice on prosthetic finger control with an intuitive myoelectric decoder
  • Gesture recognition and biometrics electromyogram (grabmyo) (opens the publisher in a new tab)
  • Capg-myo: a muscle-computer interface supporting user-defined gesture recognition
  • Processing emg signals using reservoir computing on an event-based neuromorphic system
  • Developing a practical application of the isometric squat and surface electromyography
  • Classification of gait muscle activation patterns according to knee injury history using a support vector machine approach
  • High-density emg, imu, kinetic, and kinematic open-source data for comprehensive locomotion activities
  • Surface electromyogram, kinematic, and kinetic dataset of lower limb walking for movement intent recognition
  • RV Schulte et al. Roessingh research & development-myleg database for activity prediction (mypredict). 4tu. ResearchData https://doi.org/10.4121/20418720, 2023. (opens the publisher in a new tab)
  • Building the ninapro database: A resource for the biorobotics community
  • Multi-day dataset of forearm and wrist electromyogram for hand gesture recognition and biometrics
  • Optimization-free test-time adaptation for cross-person activity recognition
  • Quantization and training of neural networks for efficient integer-arithmetic-only inference
  • Squeeze-and-excitation networks
  • Embedded machine learning for tinyml systems