Oracle headroom without signal: null-calibrated evaluation of candidate selection for thermal heart rate estimation

Mohammad Rakibur Rahman, Nhi Nguyen, Sasan Sharifipour, Le Nguyen, Manuel Lage Cañellas, Miguel Bordallo López, Constantino Álvarez Casado

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

ABSTRACT

Camera-based physiological monitoring can produce multiple estimates from several facial regions, extraction methods, and processing settings. Signal quality indices aim to select reliable estimates without a physiological reference, and their potential is often assessed with an oracle that selects the estimate closest to the reference in each window. This retrospective selection can reward chance agreement. We model the effect with order statistics. For K independent candidates unrelated to the reference, the expected oracle error decreases approximately as 1/K. We analyze thermal heart rate estimation on 96 iBVP recordings with 168 candidates per 10 s window. The oracle achieves a mean absolute error of 0.91 bpm, compared with 10.74 bpm for the best fixed configuration, 18.03 bpm for the best quality index, and 8.61 bpm for a constant predictor. With K = 24, a forehead signal from another recording matches the correct one, with 4.62 against 4.61 bpm. Oracle evaluations should report candidate count, valid coverage, and matched null controls.

Index Terms— Thermal imaging, heart rate estimation, signal quality, oracle selection, order statistics

1. INTRODUCTION

Camera-based physiological monitoring increasingly combines several extraction routes, such as facial regions, motion signals, and learned models, with several rate estimators [1, 2, 3]. No route is best in every window, so quality-aware frameworks use signal quality indices (SQIs) to decide which candidate to trust. Their evaluation often includes an oracle that uses the reference to select the most accurate candidate in each window. In our video respiratory study, this oracle reduced the mean absolute error (MAE) on the OMuSense-23 dataset from 3.03 to 0.44 breaths/min, and the gap was attributed to imperfect quality prediction rather than to limited extractor diversity [1]. Such gaps are used to justify richer quality models and larger candidate banks. An inflated gap directs effort to headroom that does not exist, and a deployed selector may then report confident estimates from signals without physiological content.

That interpretation assumes that the oracle measures information in the candidates. The oracle also benefits from multiplicity. When K estimates lie in a plausible physiological range, one of them is likely to fall close to the reference even when none contains information on it. Related selection effects are established in model selection, circular analysis, and decoding studies that exceed theoretical chance by chance [4, 5, 6]. Rate estimation is particularly exposed, because every spectral peak estimator returns a frequency inside its passband. A band-limited candidate bank is therefore plausible by construction.

Thermal facial video provides a suitable test case. The cardiac pulse has been recovered from thermal images of superficial ves-

Figure

Fig. 1. Null-calibrated oracle evaluation. A thermal crop from iBVP (recording p02a, 72×7272 \times 72 pixels) with the six fixed regions of interest (ROIs) used here, and the learned model output, give seven signals. Each passes through 24 processing settings. Fixed and quality selection use signals only. The oracle also uses the reference. Matched null inputs pass through the same settings, so that oracle errors can be compared at equal candidate count K.

sels under controlled acquisition [7, 8], but the regional temperature averages gave weak cardiac agreement in our thermal monitoring study [9] and in the associated thesis [10]. A large oracle gain on such signals should be explained before it is read as headroom.

We formulate a null-calibrated oracle evaluation and apply it to thermal heart rate estimation on iBVP [11], as depicted in Figure 1. The contributions are as follows:

• An order statistic model of oracle error for candidates without information about the reference, with a closed form 1/K approximation that gives a reference curve of uninformed candidates for any band-limited bank.

• A measurement of oracle error against candidate count on 6,816 thermal windows with 168 candidates, compared with fixed, SQI, and constant predictors and with the model.

• A ladder of matched nulls at the same K, from white noise to a thermal signal of another recording, which separates cardiac correspondence from spectral and thermal dynamics, and a reporting protocol for oracle bounds.