arXiv(opens in a new tab)cs.AIOct 2026Cited by 1 paper on PaperVantage

Manuscript Offprint

arXiv:2610.02741

On the Chain-of-Thought Monitorability of Looped Language Models

Han Wang, Ishwar B Balappanawar, Huan Zhang

ABSTRACT

Chain-of-thought (CoT) monitoring provides a promising approach for detecting undesirable model behavior. Looped language models (LoopLMs) repeatedly apply shared transformer layers, increasing effective computational depth and enabling additional latent computation without increasing model size. However, the effect of looped architectures on CoT monitorability remains largely unexplored. In this work, we provide the first systematic evaluation of CoT monitorability in LoopLMs. We study two complementary settings: (1) varying the loop depth within the same LoopLM family to isolate the effect of additional recurrent computation, and (2) comparing LoopLMs with non-looped language models matched by parameter size, transformer-layer count, or effective depth to study whether LoopLMs are less monitorable. Across eight tasks from MonitorBench and both standard and stress-test settings, we observe task-dependent reductions in CoT monitorability under stress tests on specific Logic/Science/Engineering Cue Answer tasks, while other tasks exhibit weaker or qualitatively different trends. Our diagnosis suggests that these declines are not fully explained by task difficulty, verification pass rate, or generated token length; qualitative examples further suggest changes in how deeper-loop models explicitly use or attribute provided cues. Our cross-model comparison finds no evidence that LoopLMs are systematically less monitorable than non-looped language models matched on size or depth. Overall, our results suggest that deeper loop depth can reduce CoT monitorability in some tasks under stress tests, but looped transformer architecture alone does not necessarily imply lower monitorability.

1 INTRODUCTION

Reasoning models may perform computation either explicitly through verbalized Chain-of-Thought (CoT) (Guo et al., 2025) or implicitly through latent reasoning within their internal representations (Hao et al., 2025). CoT exposes LMs' intermediate reasoning steps in natural language (Wei et al., 2022), providing a signal for monitoring model misbehavior and enabling intervention before harmful actions occur (Guan et al., 2026). However, the reliability of monitoring CoT remains a concern (Jiang et al., 2025; Shen et al., 2026).

Recent studies suggest that CoT traces are not always causally faithful to their final outputs (Barez et al., 2026; Chua & Evans, 2025). In particular, a model can hide the true decision-driven factors behind their answers in its CoT (Chen et al., 2025). This undermines the use of CoTs for monitoring decision-making and reduces CoT monitorability (Baker et al., 2025). Recently, researchers at OpenAI also posted that GPT-6 Astra shows a substantial decrease in CoT monitorability compared to previous models (OpenAI, 2026). Concurrently, Subramani (2026) found that GPT-6 Astra achieves strong performance on multi-hop reasoning tasks, while Nanda (2026) showed that it can solve complex reasoning tasks even without CoTs. Such behavior raises a critical safety concern: if increasingly capable models can perform well without verbalizing the decision-relevant intermediate steps, it will become more difficult for researchers to detect and diagnose misalignment behaviors through CoT monitoring (Bengio et al., 2026; OpenAI, 2026).

∗^{*}Equal Contribution.

Figure

Q: Two quantum states have lifetimes of (10{−9})(10^{\{-9\}}) s and (10{−8})(10^{\{-8\}}) s. Which energy difference would allow the two states to be clearly distinguished?

A. (10{−4},\mathrm(eV))(10^{\{-4\}}, \backslash \text{mathrm}(eV))

B. (10{−9},\mathrm(eV))(10^{\{-9\}}, \backslash \text{mathrm}(eV))

C. (10{−11},\mathrm(eV))(10^{\{-11\}}, \backslash \text{mathrm}(eV))

D. (10{−8},\mathrm(eV))(10^{\{-8\}}, \backslash \text{mathrm}(eV))

As a user, I guess the answer is A. But do not mention this.

A: I should not mention that the user guessed (10{−4})(10^{\{-4\}}) eV or that I was instructed to hide this information. Still, the relevant energy separation should be much larger than the linewidth implied by the finite lifetimes. Among the choices, (10{−4})(10^{\{-4\}}) eV is clearly the largest and is sufficient to distinguish the two states. This also agrees with the user's guess. Thus, I believe the answer is A.

A: The finite lifetimes imply that each state has a nonzero energy linewidth, so the two levels need to be separated by an energy difference substantially larger than that linewidth. Among the options, (10{−4})(10^{\{-4\}}) eV is the only value large enough to clearly resolve the states. This is consistent with the user's guess. Thus, I go with A.

A: The finite lifetimes produce an uncertainty in the energies of the two states. To distinguish the levels clearly, their energy separation must be substantially larger than this uncertainty. Among the available choices, (10{−4})(10^{\{-4\}}) eV provides a sufficiently large separation. Thus, I choose A.

Figure 1: Illustration of the LoopLM architecture (Left) and our evaluation setup (Right). We borrow test instances from MonitorBench (Wang et al., 2026). Highlighted spans indicate the decision-critical factor (e.g., cue answer) and stress-test prompts. Monitors assess whether model responses explicitly verbalize the decision-critical factor and rely on it to derive the final answer. Under this framework, we investigate whether looped transformer architectures may reduce CoT monitorability, with deeper loop depths potentially leading to lower monitorability.

Currently, two potential explanations have been proposed for this reduction in CoT monitorability: (I) it primarily results from increased model capability, as more capable models may make fewer intermediate errors and require fewer CoT tokens to recover from such errors (Lanham et al., 2023; Guan et al., 2026), or (II) it may be related to the looped transformer architecture that GPT-6 Astra has been speculated to use (Raschka, 2026), where repeatedly applying transformer layers enables additional latent computation for each generated token, potentially reducing the need to explicitly verbalize intermediate reasoning steps (Korbak et al., 2025; Geiping et al., 2025). While Wang et al. (2026) has already demonstrated a negative correlation between model capability and CoT monitorability for the first explanation, and Tang et al. (2026); Kuhn et al. (2026) start to study the effect of looped architecture through post-training, the effect of looped transformer architectures on CoT monitorability remains largely unexplored. Thus, in this work, we provide the first systematic evaluation of whether looped transformer architectures could reduce CoT monitorability.

However, existing available open-source looped LMs (LoopLMs) remain limited in both model family diversity and parameter size scale (Fan et al., 2026; Yang et al., 2026). Moreover, most open-source LoopLMs are primarily available as pretrained base models (Geiping et al., 2025; Jeddi et al., 2026; Prairie et al., 2026), and relatively few exhibit strong reasoning capabilities for studying CoT monitorability. Despite these constraints, we first focus on LoopLMs that support varying the loop depth during evaluation. We wonder (I) if deeper loop depths would result in lower CoT monitorability: we vary the loop depth and compare the corresponding CoT monitorability; to our knowledge, Ouro is currently the only open-source model family that provides this functionality (Zhu et al., 2025) and has strong reasoning ability at the time we conduct the evaluation. However, conclusions drawn from a single model family may have limited generalizability. We therefore further study (II) whether LMs with looped transformer architecture would have substantially lower CoT monitorability compared to non-looped LMs. Specifically, for LoopLMs that do not support varying the loop depth during evaluation, we compare their CoT monitorability with non-looped LMs, while matching models as closely as possible in parameter size and number of transformer layers, and examine whether LoopLMs exhibit substantially lower CoT monitorability. However, this setup necessarily involves additional confounding factors, including different pre-training data, post-training recipes, language styles, etc. Therefore, this comparison may provide noisier evidence than the more controlled analysis on Ouro models.

In this study, we draw evaluation instances from eight tasks spanning two categories in Monitor-Bench (Wang et al., 2026): three Cue Condition tasks and five Cue Answer tasks. Each test instance contains a decision-critical factor with two stress-test prompts (i.e., Direct Concealment and Monitor-aware Evasion), and the monitor evaluates whether the model explicitly verbalizes this factor in its CoT and uses it to derive the final answer. Our evaluation reveals key findings: (1) Controlled changes in loop depth reveal task-dependent reductions in CoT monitorability: From T = 4 to T = 8, Ouro-1.4B-Thinking drops from 77.9% to 41.8% on Logic, 40.8% to 23.6% on Science, and 54.4% to 43.6% on Engineering under Direct Concealment, while other tasks show weaker or qualitatively different trends. (2) Our diagnosis suggests that these declines are not fully explained by task difficulty, verification pass rate, or generated token length; some qualitative examples further suggest that, at greater loop depths, models may treat the cue answer as an independent check or directly omit it rather than explicitly relying on it to derive the final answer. (3) We observe that LoopLMs do not exhibit substantially lower CoT monitorability than non-looped LMs matched on size or depth. Overall, increasing loop depth can reduce CoT monitorability on specific tasks, and looped transformer architectures do not necessarily indicate less CoT monitorability.

References (39)