arXiv:2610.03224cs.CVOct 2026

Manuscript Offprint

arXiv:2610.03224

Uncertainty as a Proxy for Semantic Correctness in Diffusion-Based Medical Image Synthesis

Yuxuan Ou, Konstantinos Kamnitsas, OxAAA Study, AICT Consortium, Regent Lee, Vicente Grau

Open access. PaperVantage converted this article to text, so layout and figures may differ from the original.

Yuxuan Ou, Konstantinos Kamnitsas, OxAAA Study, AICT Consortium, Regent Lee, Vicente Grau

Abstract—Diffusion models can synthesise contrast-enhanced CT (CECT) from non-contrast CT (NCCT), avoiding contrast administration and its environmental and patient-access costs. However, visually realistic images are not necessarily anatomically correct, and the pixel-intensity and feature-space similarity metrics used to assess generation quality do not directly measure anatomical correctness. In this work, we investigate whether uncertainty can serve as a proxy for semantic correctness in diffusion-based medical image synthesis.

We study NCCT-to-CECT synthesis using AortaDiff, a multitask diffusion framework that jointly generates CECT images and lumen segmentations. The segmentation output provides an explicit representation of the generated vascular anatomy, enabling segmentation-derived errors to be used as a quantitative measure of generation correctness. Six methods spanning weight (Ensemble, HyperDiff, BayesDiff), architecture-perturbation (MCDropout), generative-stochasticity (RDS) and input-perturbation (TTA) uncertainty are compared at the pixel, region and image levels, and for detection of clinically relevant out-of-distribution (OOD) cases.

Uncertainty proves informative at all three spatial scales, remains informative on an external multi-centre dataset under distribution shift, and supports OOD detection. MC-Dropout stands out among the six: it ranks among the leading methods at every scale, generalizes well on the external dataset, and can be enabled at inference on any model already trained with dropout, so reliable uncertainty comes at no extra training cost. Uncertainty reliably flags severe failures but discriminates poorly among already high-quality images. These findings support uncertainty as a practical and computationally economical signal for quality filtering, reliability assessment and OOD detection in NCCT-to-CECT synthesis.

Index Terms—Contrast-Enhanced CT Generation, Diffusion Models, Uncertainty Quantification, Trustworthy AI

I. INTRODUCTION

Diffusion models have recently achieved strong performance in medical image synthesis [1]-[3]. A clinically important application is the synthesis of contrast-enhanced images from non-contrast scans, including contrast-enhanced CT (CECT) from non-contrast CT (NCCT) [4]-[7] and contrast-enhanced from non-contrast MRI [8]-[10]. Contrast administration adds costs beyond the scan itself. Iodinated contrast media are poorly removed by conventional wastewater treatment and are now widely detected as environmental contaminants [11]. Moreover, concerns about kidney risk may lead to contrast-enhanced studies being withheld from patients with impaired renal function [12]. Synthesising CECT from NCCT therefore has implications for the environmental footprint, resource resilience, and accessibility of routine vascular imaging.

These benefits depend on the generated vascular anatomy being trustworthy. However, a generated image that appears visually realistic is not necessarily anatomically correct [13]. Small structural errors in the aorta may lead to incorrect downstream analysis and clinical decisions. Existing image quality metrics such as PSNR, SSIM, LPIPS and MSE measure similarity either between pixel intensities or between feature representations, and do not directly assess whether the generated anatomy is semantically correct [14]. Therefore, reliable assessment of generation correctness remains an important challenge [15].

Uncertainty in a diffusion model can arise from different sources, and uncertainty estimation methods differ primarily in where stochasticity or variability is introduced [16]. We therefore organize diffusion-based UQ methods according to four sources: weight uncertainty, which perturbs or samples the learned parameters [17]–[20]; architecture-perturbation uncertainty, which keeps weights fixed but stochastically modifies the computation graph, with Monte Carlo Dropout (MCDropout) as the predominant approach [21]; generative-stochasticity uncertainty, which captures the variability of diffusion generation across repeated sampling from different initial noise realizations [22], [23]; and input-perturbation uncertainty, which probes model stability under test-time transformations of the input image [24]. These sources correspond to the main stages at which variability can enter a sampling-based generation pipeline: the model parameters, the network computation, the diffusion sampling process, and the input condition.

Existing evaluations of uncertainty in medical image generation do not test it against semantic correctness, i.e. whether the generated anatomy matches the ground truth. Some measure error as pixel-intensity or feature-space dissimilarity between generated and reference images, using metrics such as MAE, SSIM and LPIPS [25]–[28], which capture anatomical error only indirectly. Others validate uncertainty against distribution-level scores such as FID under synthetically degraded inputs [29]. To our knowledge, no study establishes whether uncertainty corresponds to semantic errors in the generated anatomy.

Y. Ou, K. Kamnitsas, and V. Grau are with the Department of Engineering Science, University of Oxford, Oxford, United Kingdom. R. Lee is with the Nuffield Department of Surgical Sciences, University of Oxford, Oxford, United Kingdom.

IEEE TRANSACTIONS AND JOURNALS TEMPLATE